Concurrent validity and reliability of a mobile tracking technology to measure angular and linear movements of the neck.

Abstract:

:The neck can be moved in six degrees of freedom. Current 3D-optoelectronic motion-capture systems capable of measuring these movements are inappropriate for use in clinical practice because they are stationary, expensive and time-consuming. We therefore developed a less complex 3D-tracking technology based on Steam®VR to measure six degrees of freedom in a clinical setting. The aim of this study was to assess the validity and reliability of this system. The developed prototype consists of two infrared-emitting lighthouses and sensors, mounted on the participant's helmet and trunk belt, to detect the orientation of the head and trunk. The system was evaluated by means of an infrared light-reflecting marker tracking system. Twenty healthy participants, equipped with these sensors and markers, performed thirteen neck movement tasks. Linear and angular movements were measured. These tasks were repeated after six to eight days to assess test-retest reliability. Concurrent validity was assessed by the root mean square error, and reliability with generalizability theory. With an average root mean square error between 1.2 and 2.0° in angular and 0.4-0.5 cm in linear movements, the prototype was shown to precisely track these movements. Reliability of the prototype and the reference system was comparable for all tasks. A high contribution of participant's variability to the observed variance was generally detected, with the exception of joint repositioning error and upper cervical flexion. The reliability was task-specific and did not differ between the systems. The prototype system was shown to be valid, although the reliability of the repositioning and upper cervical flexion tests needs to be reconsidered.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Sommer BB,Weisenhorn M,Ernst MJ,Meichtry A,Rast FM,Kleger D,Schmid P,Lünenburger L,Bauer CM

doi

10.1016/j.jbiomech.2019.109340

subject

Has Abstract

pub_date

2019-11-11 00:00:00

pages

109340

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(19)30562-7

journal_volume

96

pub_type

杂志文章
  • Biomechanical response to mediolateral foot-placement perturbations during walking.

    abstract::Dynamic balance in the frontal plane requires active control, which is accomplished largely through control of mediolateral foot placement. Individuals without mobility impairments have the ability to compensate for variability in foot-placement to maintain their balance; however, it is unknown how individuals respond...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110213

    authors: Brough LG,Klute GK,Neptune RR

    更新日期:2020-12-28 00:00:00

  • Suitability of Kinect for measuring whole body movement patterns during exergaming.

    abstract::Exergames provide a challenging opportunity for home-based training and evaluation of postural control in the elderly population, but affordable sensor technology and algorithms for assessment of whole body movement patterns in the home environment are yet to be developed. The aim of the present study was to evaluate ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.07.017

    authors: van Diest M,Stegenga J,Wörtche HJ,Postema K,Verkerke GJ,Lamoth CJ

    更新日期:2014-09-22 00:00:00

  • Circumferentially flexible vascular grafts.

    abstract::An arterial graft with a corrugated cylindrical cross-section has been proposed as a partial solution to the problem of elastic stiffness mismatch between conventional grafts and arterial tissue (Trescony et al., 1994, US Patent 5,282, 847 (granted February 1 1994)). A two-dimensional ring theory model and a finite el...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00084-0

    authors: Stump DM,Hart VG,Tuttle SL

    更新日期:1998-08-01 00:00:00

  • A probabilistic orthopaedic population model to predict fatigue-related subacromial geometric variability.

    abstract::Fatigue-related glenohumeral and scapulothoracic kinematic relationships, in addition to morphological characteristics of the scapula and humerus, affect the dimensions of the subacromial space. Each exhibits considerable interpersonal variability, which if only considering the mean, can lead to misleading population ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.12.049

    authors: Chopp-Hurley JN,Langenderfer JE,Dickerson CR

    更新日期:2016-02-29 00:00:00

  • Changes of opening angle in hypertensive and hypotensive arteries in 3-day organ culture.

    abstract::To study the effect of pressure changes on the opening angle of arteries in organ culture, tubular segments of porcine common carotid arteries were cultured with pulsatile flow perfusion under hypertensive (150+/-20 mmHg), normotensive (100+/-20 mmHg), or hypotensive (30+/-10 mmHg) pressure while maintaining the arter...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.08.003

    authors: Han HC,Marita S,Ku DN

    更新日期:2006-01-01 00:00:00

  • Simulation of mechanical behavior of temperature-responsive braided stents made of shape memory polyurethanes.

    abstract::Polymeric stents can be considered as an alternative to metallic stents thanks to their lessened incidence of restenosis and controlled deployment. The purpose of this study was to investigate the feasibility of developing a temperature-responsive braided stent using shape memory polyurethane (SMPU) through finite ele...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.032

    authors: Kim JH,Kang TJ,Yu WR

    更新日期:2010-03-03 00:00:00

  • Gait variability and symmetry remain consistent during high-intensity 10,000 m treadmill running.

    abstract::The aim of this study was to analyze changes in gait variability and symmetry in distance runners. Fourteen competitive athletes ran on an instrumented treadmill for 10,000 m at speeds equivalent to 103% of their season's best time. Spatiotemporal and ground reaction force data were recorded at 1500, 3000, 5000, 7500 ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.08.008

    authors: Hanley B,Tucker CB

    更新日期:2018-10-05 00:00:00

  • Jet collisions and vortex reversal in the human left ventricle.

    abstract::Unnatural dynamics of the notorious vortex in the left ventricle is often associated with cardiac disease. Understanding how different cardiac diseases alter the flow physics in the left ventricle may therefore provide a powerful tool for disease detection. In this work, the fluid dynamics in the left ventricle subjec...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.07.023

    authors: Di Labbio G,Kadem L

    更新日期:2018-09-10 00:00:00

  • Stance and swing phase detection during level and slope walking in the cat: effects of slope, injury, subject and kinematic detection method.

    abstract::In quadrupeds, there have been limited comparisons of gait timing events detection (e.g., paw contact, PC and paw-off, PO) determined from kinematics and forceplates. The goal of this study was to investigate the effect of different slopes (0, -27, +27°), recovery times after ankle extensor nerve injury and repair (2,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.03.013

    authors: Pantall A,Gregor RJ,Prilutsky BI

    更新日期:2012-05-11 00:00:00

  • Stepping over an obstacle increases the motions and moments of the joints of the trailing limb in young adults.

    abstract::Tripping over obstacles is the most frequently mentioned causes of falls. Thus, this study was performed to test the hypotheses that when crossing obstacles, toe-obstacle clearance and the three-dimensional motions and moments at the hip, knee, and ankle of the trailing limb (limb crossing the obstacle last) increase ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(96)00161-3

    authors: Chou LS,Draganich LF

    更新日期:1997-04-01 00:00:00

  • Transient body sway characteristics during single-leg quiet stance in ballet dancers and young adults.

    abstract::This study explored transient characteristics of body sway during single-leg quiet stance in young ballet dancers (n = 41) and young healthy adults (n = 58). We compared the groups in terms of center of pressure (CoP) parameters (CoP velocity and amplitude, averaged across the duration of the 30-s trial), and the tran...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110195

    authors: Kozinc Ž,Šarabon N

    更新日期:2021-01-22 00:00:00

  • Cervical spine morphology and ligament property variations: A finite element study of their influence on sagittal bending characteristics.

    abstract::Cervical spine finite element models reported in biomechanical literature usually represent a static morphology. Not considering morphology as a model parameter limits the predictive capabilities for applications in personalized medicine, a growing trend in modern clinical practice. The objective of the study was to i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.12.044

    authors: John JD,Saravana Kumar G,Yoganandan N

    更新日期:2019-03-06 00:00:00

  • Fatigue creep damage at the cement-bone interface: an experimental and a micro-mechanical finite element study.

    abstract::The goal of this study was to quantify the micromechanics of the cement-bone interface under tensile fatigue loading using finite element analysis (FEA) and to understand the underlying mechanisms that play a role in the fatigue behavior of this interface. Laboratory cement-bone specimens were subjected to a tensile f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.07.014

    authors: Waanders D,Janssen D,Miller MA,Mann KA,Verdonschot N

    更新日期:2009-11-13 00:00:00

  • Superficial aponeurosis of human gastrocnemius is elongated during contraction: implications for modeling muscle-tendon unit.

    abstract::Two questions were addressed in this study: (1) how much strain of the superficial aponeurosis of the human medial gastrocnemius muscle (MG) was obtained during voluntary isometric contractions in vivo, (2) whether there existed inhomogeneity of the strain along the superficial aponeurosis. Seven male subjects, whose ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00196-8

    authors: Muramatsu T,Muraoka T,Kawakami Y,Fukunaga T

    更新日期:2002-02-01 00:00:00

  • Hospital bed height influences biomechanics during bed egress: A comparative controlled study of patients with Parkinson disease.

    abstract::Although a significant proportion of patient falls occur during egress from the hospital bed, the biomechanical adaptations during egress from different bed heights are still largely unknown. The purpose of this study was to evaluate the effect of hospital bed height on natural transition during egress in patients wit...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110116

    authors: Xu H,Li X,Shi Y,An L,Taylor D,Christman M,Morse J,Merryweather A

    更新日期:2021-01-22 00:00:00

  • A novel approach to estimate trabecular bone anisotropy using a database approach.

    abstract::Continuum finite element (FE) models of bones have become a standard pre-clinical tool to estimate bone strength. These models are usually based on clinical CT scans and material properties assigned are chosen as isotropic based only on the density distribution. It has been shown, however, that trabecular bone elastic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.07.042

    authors: Hazrati Marangalou J,Ito K,Cataldi M,Taddei F,van Rietbergen B

    更新日期:2013-09-27 00:00:00

  • The influence of mechanical vibration on local and central balance control.

    abstract::Fall prevention has an indispensable role in enhancing life expectancy and quality of life among older adults. The first step to prevent falls is to devise reliable methods to identify individuals at high fall risk. The purpose of the current study was to assess alterations in local postural muscle and central sensory...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2018.01.027

    authors: Ehsani H,Mohler J,Marlinski V,Rashedi E,Toosizadeh N

    更新日期:2018-04-11 00:00:00

  • Strain shielding in proximal tibia of stemmed knee prosthesis: experimental study.

    abstract::Theoretical concerns about the use of cemented or press-fit stems in revision total knee arthroplasty (TKA) include stress shielding with adverse effects on prosthesis fixation. Revision TKA components are commonly stemmed to protect the limited autogenous bone stock remaining. Revision procedures with the use of stem...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.10.006

    authors: Completo A,Fonseca F,Simões JA

    更新日期:2008-01-01 00:00:00

  • Pulsatile flow of non-Newtonian fluids through arterial stenoses.

    abstract::The problem of blood flow through stenoses is solved using the incompressible generalized Newtonian model. The Herschel-Bulkley, Bingham and power-law fluids are incorporated. The geometry corresponds to a rigid circular tube with a partial occlusion. Calculations are performed by a Galerkin finite-element method. For...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00151-4

    authors: Tu C,Deville M

    更新日期:1996-07-01 00:00:00

  • Deficiency of macrophage migration inhibitory factor gene delays healing of the medial collateral ligament: a biomechanical and biological study.

    abstract::The role played by macrophage migration inhibitory factor (MIF) in the process of wound healing is controversial. Besides, there have been no reports that investigated the expression or the role of MIF in the repair process after ligament injury. In this study, we hypothesized that the deficiency in MIF gene might del...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.09.018

    authors: Kitayama S,Onodera S,Kondo E,Kobayashi T,Miyatake S,Kitamura N,Tohyama H,Yasuda K

    更新日期:2011-02-03 00:00:00

  • Robotic simulation of identical athletic-task kinematics on cadaveric limbs exhibits a lack of differences in knee mechanics between contralateral pairs.

    abstract::Limb asymmetry is a known factor for increased ACL injury risk. These asymmetries are normally observed during in vivo testing. Prior studies have developed in vitro testing methodologies driven by in vivo kinematics to investigate knee mechanics relative to ACL injury. The objective of this study was to determine if ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.12.019

    authors: Bates NA,McPherson AL,Nesbitt RJ,Shearn JT,Myer GD,Hewett TE

    更新日期:2017-02-28 00:00:00

  • Walking speed differentially alters spinal loads in persons with traumatic lower limb amputation.

    abstract::Persons with lower limb amputation (LLA) perceive altered motions of the trunk/pelvis during activities of daily living as contributing factors for low back pain. When walking (at a singular speed), larger trunk motions among persons with vs. without LLA are associated with larger spinal loads; however, modulating wal...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.11.026

    authors: Hendershot BD,Shojaei I,Acasio JC,Dearth CL,Bazrgari B

    更新日期:2018-03-21 00:00:00

  • The flexural rigidity of the aortic valve leaflet in the commissural region.

    abstract::Flexure is a major deformation mode of the aortic valve (AV) leaflet, particularly in the commissural region where the upper portion of the leaflet joins the aortic root. However, there are no existing data known on the mechanical properties of leaflet in the commissural region. To address this issue, we quantified th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.10.026

    authors: Mirnajafi A,Raymer JM,McClure LR,Sacks MS

    更新日期:2006-01-01 00:00:00

  • The mechanical effects of different levels of cement penetration at the cement-bone interface.

    abstract::The mechanical effects of varying the depth of cement penetration in the cement-bone interface were investigated using finite element analysis (FEA) and validated using companion experimental data. Two FEA models of the cement-bone interface were created from micro-computed tomography data and the penetration of cemen...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.11.033

    authors: Waanders D,Janssen D,Mann KA,Verdonschot N

    更新日期:2010-04-19 00:00:00

  • A constitutive model for vascular tissue that integrates fibril, fiber and continuum levels with application to the isotropic and passive properties of the infrarenal aorta.

    abstract::A fundamental understanding of the mechanical properties of the extracellular matrix (ECM) is critically important to quantify the amount of macroscopic stress and/or strain transmitted to the cellular level of vascular tissue. Structural constitutive models integrate histological and mechanical information, and hence...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.07.015

    authors: Martufi G,Gasser TC

    更新日期:2011-09-23 00:00:00

  • Predicting timing of foot strike during running, independent of striking technique, using principal component analysis of joint angles.

    abstract::As 3-dimensional (3D) motion-capture for clinical gait analysis continues to evolve, new methods must be developed to improve the detection of gait cycle events based on kinematic data. Recently, the application of principal component analysis (PCA) to gait data has shown promise in detecting important biomechanical f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.06.009

    authors: Osis ST,Hettinga BA,Leitch J,Ferber R

    更新日期:2014-08-22 00:00:00

  • Human pendulum approach to simulate and quantify locomotor impact loading.

    abstract::The understanding of impact mechanics during locomotion is important for research within the fields of injury prevention and footwear design. Instrumented missiles offer a worthy solution to the lack of control inherent in in vivo activities and to the isolated nature of tissue studies. However, missiles cannot mimic ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00002-y

    authors: Lafortune MA,Lake MJ

    更新日期:1995-09-01 00:00:00

  • Coping with perturbations to a layout somersault in tumbling.

    abstract::Tumbling is a dynamic movement requiring control of the linear and angular momenta generated during the approach and takeoff phases. Both of these phases are subject to some variability even when the gymnast is trying to perform a given movement repeatedly. This paper used a simulation model of tumbling takeoff to est...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00077-0

    authors: King MA,Yeadon MR

    更新日期:2003-07-01 00:00:00

  • Characterization of polyvinyl alcohol hydrogels as tissue-engineered cartilage scaffolds using a coupled finite element-optimization algorithm.

    abstract::Mechanical strength along with high biocompatibility and water absorbing are among main characteristics of a desirable scaffold for cartilage tissue engineering. Having these properties, polyvinyl alcohol (PVA) can be a good option for constructing cartilage tissue engineering scaffolds. In this study, PVA hydrogel wa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109525

    authors: Nazouri M,Seifzadeh A,Masaeli E

    更新日期:2020-01-23 00:00:00

  • Alteration Young's moduli by protein 4.1 phosphorylation play a potential role in the deformability development of vertebrate erythrocytes.

    abstract::The mechanical properties of vertebrate erythrocytes depend on their cytoskeletal protein networks. Membrane skeleton proteins spectrin and protein 4.1 (4.1R) cross-link with actin to maintain membrane stability under mechanical stress. Phosphorylation of 4.1R alters the affinity of 4.1R for spectrin-actin binding and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.07.022

    authors: Tang F,Lei X,Xiong Y,Wang R,Mao J,Wang X

    更新日期:2014-10-17 00:00:00