Suitability of Kinect for measuring whole body movement patterns during exergaming.

Abstract:

:Exergames provide a challenging opportunity for home-based training and evaluation of postural control in the elderly population, but affordable sensor technology and algorithms for assessment of whole body movement patterns in the home environment are yet to be developed. The aim of the present study was to evaluate the use of Kinect, a commonly available video game sensor, for capturing and analyzing whole body movement patterns. Healthy adults (n=20) played a weight shifting exergame under five different conditions with varying amplitudes and speed of sway movement, while 3D positions of ten body segments were recorded in the frontal plane using Kinect and a Vicon 3D camera system. Principal Component Analysis (PCA) was used to extract and compare movement patterns and the variance in individual body segment positions explained by these patterns. Using the identified patterns, balance outcome measures based on spatiotemporal sway characteristics were computed. The results showed that both Vicon and Kinect capture >90% variance of all body segment movements within three PCs. Kinect-derived movement patterns were found to explain variance in trunk movements accurately, yet explained variance in hand and foot segments was underestimated and overestimated respectively by as much as 30%. Differences between both systems with respect to balance outcome measures range 0.3-64.3%. The results imply that Kinect provides the unique possibility of quantifying balance ability while performing complex tasks in an exergame environment.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

van Diest M,Stegenga J,Wörtche HJ,Postema K,Verkerke GJ,Lamoth CJ

doi

10.1016/j.jbiomech.2014.07.017

subject

Has Abstract

pub_date

2014-09-22 00:00:00

pages

2925-32

issue

12

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(14)00398-4

journal_volume

47

pub_type

杂志文章
  • Coping with perturbations to a layout somersault in tumbling.

    abstract::Tumbling is a dynamic movement requiring control of the linear and angular momenta generated during the approach and takeoff phases. Both of these phases are subject to some variability even when the gymnast is trying to perform a given movement repeatedly. This paper used a simulation model of tumbling takeoff to est...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00077-0

    authors: King MA,Yeadon MR

    更新日期:2003-07-01 00:00:00

  • A potential role of smooth muscle tone in early hypertension: a theoretical study.

    abstract::A conspicuous long-term consequence of hypertension is a thickening of the arterial wall, which many suggest returns the circumferential wall stress toward its normal value. This thickening results from an increase in smooth muscle and extracellular matrix, with the associated growth and remodeling processes depending...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00178-7

    authors: Humphrey JD,Wilson E

    更新日期:2003-11-01 00:00:00

  • Shear strength and toughness of trabecular bone are more sensitive to density than damage.

    abstract::Microdamage occurs in trabecular bone under normal loading, which impairs the mechanical properties. Architectural degradation associated with osteoporosis increases damage susceptibility, resulting in a cumulative negative effect on the mechanical properties. Treatments for osteoporosis could be targeted toward incre...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.09.002

    authors: Garrison JG,Gargac JA,Niebur GL

    更新日期:2011-11-10 00:00:00

  • The role of muscles in joint degeneration and osteoarthritis.

    abstract::The purpose of this work was to establish a controlled and reversible muscle weakness model for studying the effects of weakness on joint degeneration leading to osteoarthritis (OA). The knee extensor muscles of rabbits were injected with single or repeat doses of Botulinum type-A toxin (BTX-A) to partially inhibit ac...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.03.001

    authors: Herzog W,Longino D

    更新日期:2007-01-01 00:00:00

  • Towards a viscoelastic model for the unfused midpalatal suture: development and validation using the midsagittal suture in New Zealand white rabbits.

    abstract::Maxillary expansion treatment is a commonly used procedure by orthodontists to widen a patient's upper jaw. As this is typically performed in adolescent patients, the midpalatal suture, connective tissue adjoining the two maxilla halves, remains unfused. Studies that have investigated patient response to expansion tre...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.04.011

    authors: Romanyk DL,Liu SS,Lipsett MG,Toogood RW,Lagravère MO,Major PW,Carey JP

    更新日期:2013-06-21 00:00:00

  • Do quadrupeds require a change in trunk posture to walk backward?

    abstract::Previous studies on cats walking backward have indicated that they adopt a presumably adaptive posture characterized by extreme dorsiflexion of the lumbar spine. Because humans do not show any marked postural changes during backward walking, we questioned whether the posture exhibited by cats during backward walking w...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00071-3

    authors: Vilensky JA,Cook JA

    更新日期:2000-08-01 00:00:00

  • Using force sensing insoles to predict kinetic knee symmetry during a stop jump.

    abstract::Knee kinetic asymmetries are present during jump-landings in athletes returning to sport following anterior cruciate ligament (ACL) reconstruction, and are associated with an increased risk for sustaining a second ACL injury. The loadsol® is a wireless load sensing insole that can be used in non-laboratory settings. T...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.07.037

    authors: Peebles AT,Ford KR,Taylor JB,Hart JM,Sands LP,Queen RM

    更新日期:2019-10-11 00:00:00

  • Versatile and inexpensive Hall-Effect force sensor for mechanical characterization of soft biological materials.

    abstract::Mismatch of hierarchical structure and mechanical properties between tissue-engineered implants and native tissue may result in signal cues that negatively impact repair and remodeling. With bottom-up tissue engineering approaches, designing tissue components with proper microscale mechanical properties is crucial to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.065

    authors: Backman DE,LeSavage BL,Wong JY

    更新日期:2017-01-25 00:00:00

  • Non-Newtonian blood flow in human right coronary arteries: steady state simulations.

    abstract::This study looks at blood flow through four different right coronary arteries, which have been reconstructed from bi-plane angiograms. Five non-Newtonian blood models, as well as the usual Newtonian model of blood viscosity, are used to study the wall shear stress in each of these arteries at a particular point in the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.09.016

    authors: Johnston BM,Johnston PR,Corney S,Kilpatrick D

    更新日期:2004-05-01 00:00:00

  • An instrumental approach for monitoring physical exercises in a visual markerless scenario: A proof of concept.

    abstract::This work proposes a real-time monitoring tool aimed to support clinicians for remote assessing exercise performances during home-based rehabilitation. The study relies on clinician indications to define kinematic features, that describe five motor tasks (i.e., the lateral tilt of the trunk, lifting of the arms, trunk...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.01.008

    authors: Capecci M,Ceravolo MG,Ferracuti F,Grugnetti M,Iarlori S,Longhi S,Romeo L,Verdini F

    更新日期:2018-03-01 00:00:00

  • Measurements of active myocardial tension under a wide range of physiological loading conditions.

    abstract::Active tension developed while cardiac muscle shortens has been studied extensively under afterloaded isotonic or isovelocity conditions. However, these are not true in vivo loading conditions. To obtain more physiological loading, we controlled sarcomere length to follow the time courses that we observed previously i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(96)00122-4

    authors: Guccione JM,Le Prell GS,de Tombe PP,Hunter WC

    更新日期:1997-02-01 00:00:00

  • In vivo kinematics and articular surface congruency of total ankle arthroplasty during gait.

    abstract::Relatively high rates of loosening and implant failure have been reported after total ankle arthroplasty. Abnormal kinematics and incongruency of the articular surface may cause increased contact pressure and rotational torque applied to the implant, leading to loosening and implant failure. We measured in vivo kinema...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.05.043

    authors: Yamaguchi S,Tanaka Y,Banks S,Kosugi S,Sasho T,Takahashi K,Takakura Y

    更新日期:2012-08-09 00:00:00

  • The transmission of translational seat vibration to the head--II. Horizontal seat vibration.

    abstract::The second part of this study of the six axes of head motion caused by translational seat vibration is concerned with the effect of fore-and-aft (x-axis) and lateral (y-axis) seat vibration. Seat-to-head transmissibilities have been determined at frequencies up to 16 Hz for each of the three translational and three ro...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90170-4

    authors: Paddan GS,Griffin MJ

    更新日期:1988-01-01 00:00:00

  • Assessment of wavelet analysis of gait in children with typical development and cerebral palsy.

    abstract::The objective of this study was to examine the use of the continuous wavelet transform (CWT) on surface electromyographic (sEMG) signals acquired from the lower extremity muscles during gait in children with typical development (TD) and cerebral palsy (CP). This was done to explore the possibility of developing a quan...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2004.07.002

    authors: Lauer RT,Stackhouse C,Shewokis PA,Smith BT,Orlin M,McCarthy JJ

    更新日期:2005-06-01 00:00:00

  • Tensile stress-strain characteristics of the human meniscal material.

    abstract::The nonlinear stress-strain characteristics of the human menisci were determined by uniaxial elongation tests performed on circumferential and radial specimens prepared from different regions, layers, and locations. The properties of the collagen fibers and the matrix were calculated using the test results along with ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)00081-e

    authors: Tissakht M,Ahmed AM

    更新日期:1995-04-01 00:00:00

  • Location of minimum foot clearance on the shoe and with respect to the obstacle changes with locomotor task.

    abstract::Minimum foot clearance (MFC) as it relates to trips and falls has been extensively studied across many locomotor tasks, but examination of this body of research yields several studies with conflicting results and a wide range of MFCs within tasks. While there are several factors that may affect the MFC variability acr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.05.002

    authors: Loverro KL,Mueske NM,Hamel KA

    更新日期:2013-07-26 00:00:00

  • Computational assessment of the effects of the catheter type on particle-hemodynamics during liver radioembolization.

    abstract::Radioembolization, which consist of the implantation of radioactive microspheres via intra-arterially placed microcatheter, is a safe and effective treatment for liver cancer. Nevertheless, radioembolization-related complications and side effects may arise, which are an active area of ongoing research. The catheter de...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.09.035

    authors: Aramburu J,Antón R,Rivas A,Ramos JC,Sangro B,Bilbao JI

    更新日期:2016-11-07 00:00:00

  • Measurement of in vivo anterior cruciate ligament strain during dynamic jump landing.

    abstract::Despite recent attention in the literature, anterior cruciate ligament (ACL) injury mechanisms are controversial and incidence rates remain high. One explanation is limited data on in vivo ACL strain during high-risk, dynamic movements. The objective of this study was to quantify ACL strain during jump landing. Marker...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.10.028

    authors: Taylor KA,Terry ME,Utturkar GM,Spritzer CE,Queen RM,Irribarra LA,Garrett WE,DeFrate LE

    更新日期:2011-02-03 00:00:00

  • Effects of mechanical loading patterns, bone graft, and proximity to periosteum on bone defect healing.

    abstract::The goal of this study is to elucidate whether mechanobiological factors, including mechanical loading patterns, presence of bone graft, and proximity to the periosteum, correlate to de novo tissue generation and healing in critical sized long bone defects, which are enveloped by periosteum in situ and are bridged at ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.06.026

    authors: Knothe UR,Dolejs S,Matthew Miller R,Knothe Tate ML

    更新日期:2010-10-19 00:00:00

  • The poro-elastic behaviour of the intervertebral disc: A new perspective on diurnal fluid flow.

    abstract::Diurnal disc height changes, due to fluid in- and outflow, are in equilibrium while daytime spinal loading is twice as long as night time rest. A direction-dependent permeability of the endplates, favouring inflow over outflow, reportedly explains this; however, fluid flow through the annulus fibrosus should be consid...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.11.041

    authors: Vergroesen PA,van der Veen AJ,Emanuel KS,van Dieën JH,Smit TH

    更新日期:2016-04-11 00:00:00

  • PDGF-BB, IGF-I and mechanical load stimulate DNA synthesis in avian tendon fibroblasts in vitro.

    abstract::Resident cells in the surface epitenon and internal compartment of flexor tendons are subjected to cyclic mechanical load as muscle contracts to move limbs or digits. Tendons are largely tensile load bearing tissues and are highly matrix intensive with nondividing cells providing maintenance functions. However, when a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00098-4

    authors: Banes AJ,Tsuzaki M,Hu P,Brigman B,Brown T,Almekinders L,Lawrence WT,Fischer T

    更新日期:1995-12-01 00:00:00

  • Quantifying thumb opposition kinematics using dynamic computed tomography.

    abstract::Current motion capture techniques all have shortcomings when applied to the 3D quantitative evaluation of thumb base motion. Dynamic CT might overcome these shortcomings but, so far, robustness of this technique in more than one specimen has not yet been demonstrated. The aim of the current study is to further evaluat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.05.008

    authors: Kerkhof FD,Brugman E,D'Agostino P,Dourthe B,van Lenthe GH,Stockmans F,Jonkers I,Vereecke EE

    更新日期:2016-06-14 00:00:00

  • Validation of a novel method for quantifying and comparing regional ACL elongations during uniaxial tensile loading.

    abstract::Given the complex three-dimensional (3D) knee joint loading associated with anterior cruciate ligament (ACL) injuries, accurate site- and bundle-specific strain measurements are critical. The purpose of this study was to quantify tensile load-induced migrations of radio-opaque markers injected directly into the ACL, a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.08.016

    authors: Beaulieu ML,Haladik JA,Bey MJ,McLean SG

    更新日期:2012-10-11 00:00:00

  • A kinematic algorithm to identify gait events during running at different speeds and with different footstrike types.

    abstract::Although a number of algorithms exist for estimating ground contact events (GCEs) from kinematic data during running, they are typically only applicable to heelstrike running, or have only been evaluated at a single running speed. The purpose of this study was to investigate the accuracy of four kinematics-based algor...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.10.013

    authors: Handsaker JC,Forrester SE,Folland JP,Black MI,Allen SJ

    更新日期:2016-12-08 00:00:00

  • Preliminary investigation of teaching older adults the tuck-and-roll strategy: Can older adults learn to fall with reduced impact severity.

    abstract::Falls are common and potentially disastrous for older adults. A novel approach that could augment current fall prevention procedures is to teach older adults movement strategies to reduce the risk of injury. The purpose of the study was to determine whether older adults can learn a movement strategy ("tuck-and-roll") ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.12.002

    authors: Moon Y,Bishnoi A,Sun R,Shin JC,Sosnoff JJ

    更新日期:2019-01-23 00:00:00

  • Principles of measurement of vertebral rotation from frontal projections of the pedicles.

    abstract::Measurement of vertebral rotation from frontal X-ray projections of the pedicles was introduced by Nash and Moe. By the introduction of a vertebral model, their method and different modifications can be described and characterized easily. A geometrical analysis shows, that two parameters are sufficient for this model....

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(84)90005-8

    authors: Drerup B

    更新日期:1984-01-01 00:00:00

  • Differences in 3D vs. 2D analysis in lumbar spinal fusion simulations.

    abstract::Lumbar interbody fusion is currently the gold standard in treating patients with disc degeneration or segmental instability. Despite it having been used for several decades, the non-union rate remains high. A failed fusion is frequently attributed to an inadequate mechanical environment after instrumentation. Finite e...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.03.009

    authors: Hsu HW,Bashkuev M,Pumberger M,Schmidt H

    更新日期:2018-04-27 00:00:00

  • Microcrack growth parameters for compact bone deduced from stiffness variations.

    abstract::This paper shows how information on the fatigue behaviour of microcracks can be obtained by the analysis of stiffness changes measured during cyclic loading. Relationships between crack length, growth rate and cyclic stress intensity were deduced, and compared with previous empirical equations. Results show that the c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00050-5

    authors: Taylor D

    更新日期:1998-07-01 00:00:00

  • Maximum isometric arm forces in the horizontal plane.

    abstract::In this paper, we measured the maximum isometric force at the hand in eight directions in the horizontal plane and at five positions in the workplace. These endpoint forces were the result of shoulder horizontal adduction/abduction and elbow flexion/extension torques. We found that the normalized maximum forces of all...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2005.01.004

    authors: Jan Nijhof E,Gabriel DA

    更新日期:2006-01-01 00:00:00

  • Flow behaviour in an asymmetric compliant experimental model for abdominal aortic aneurysm.

    abstract::An experimental study was carried out on asymmetrical abdominal aortic aneurysm (AAA) to analyse the physiological flows involved. Velocity measurements were performed using particle image velocimetry. Resting and exercise flow rates were investigated in models with rigid and compliant walls to assess the parameters a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.11.017

    authors: Deplano V,Knapp Y,Bertrand E,Gaillard E

    更新日期:2007-01-01 00:00:00