A novel approach to estimate trabecular bone anisotropy using a database approach.

Abstract:

:Continuum finite element (FE) models of bones have become a standard pre-clinical tool to estimate bone strength. These models are usually based on clinical CT scans and material properties assigned are chosen as isotropic based only on the density distribution. It has been shown, however, that trabecular bone elastic behavior is best described as orthotropic. Unfortunately, the use of orthotropic models in FE analysis derived from CT scans is hampered by the fact that the measurement of a trabecular orientation (fabric) is not possible from clinical CT images due to the low resolution of such images. In this study, we explore the concept of using a database (DB) of high-resolution bone models to derive the fabric information that is missing in clinical images. The goal of this study was to investigate if models with fabric derived from a relatively small database can already produce more accurate results than isotropic models. A DB of 33 human proximal femurs was generated from micro-CT scans with a nominal isotropic resolution of 82 µm. Continuum FE models were generated from the images using a pre-defined mesh template in combination with an iso-anatomic mesh morphing tool. Each element within the mesh template is at a specific anatomical location. For each element within the cancellous bone, a spherical region around the element centroid with a radius of 2mm was defined. Bone volume fraction and the mean-intercept-length fabric tensor were analyzed for that region. Ten femurs were used as test cases. For each test femur, four different models were generated: (1) an orthotropic model based on micro-CT fabric measurements (gold standard), (2) an orthotropic model based on the fabric derived from the best-matched database model, (3) an isotropic-I model in which the fabric tensor was set to the identity tensor, and (4) a second isotropic-II model with its total bone stiffness fitted to the gold standard. An elastic-plastic damage model was used to simulate failure and post failure behavior during a fall to the side. The results show that all models produce a similar stress distribution. However, compared to the gold standard, both isotropic-I and II models underestimated the stress/damage distributions significantly. We found no significant difference between DB-derived and gold standard models. Compared to the gold standard, the isotropic-I models further underestimated whole bone stiffness by 26.3% and ultimate load by 14.5%, while these differences for the DB-derived orthotropic models were only 4.9% and 3.1% respectively. The results indicate that the concept of using a DB to estimate patient-specific anisotropic material properties can considerably improve the results. We expect that this approach can lead to more accurate results in particular for cases where bone anisotropy plays an important role, such as in osteoporotic patients and around implants.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Hazrati Marangalou J,Ito K,Cataldi M,Taddei F,van Rietbergen B

doi

10.1016/j.jbiomech.2013.07.042

subject

Has Abstract

pub_date

2013-09-27 00:00:00

pages

2356-62

issue

14

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(13)00375-8

journal_volume

46

pub_type

杂志文章
  • A mechanical apparatus with microprocessor controlled stress profile for cyclic compression of cultured articular cartilage explants.

    abstract::An apparatus was designed for mechanical compression of cultured articular cartilage explants with acylindrical plain-ended loading head (diameter 2-5 mm) driven by a stepping motor. A load cell under the culture dish was applied for feedback regulation utilizing a microprocessor-based control unit. The operating prog...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90232-7

    authors: Parkkinen JJ,Lammi MJ,Karjalainen S,Laakkonen J,Hyvärinen E,Tiihonen A,Helminen HJ,Tammi M

    更新日期:1989-01-01 00:00:00

  • Different methods to estimate total power and its components during lifting.

    abstract::A more fundamental understanding about the act of manual lifting can be provided by the assessment of the total production of power and the power generated in joints. The present study is concerned with the validity of the estimations of these parameters. Four subjects lifted an 18.8 kg load while they were filmed and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90045-3

    authors: de Looze MP,Bussmann JB,Kingma I,Toussaint HM

    更新日期:1992-09-01 00:00:00

  • Dynamic shear behavior of mandibular condylar cartilage is dependent on testing direction.

    abstract::Little information is available on the direction-dependency of shear behavior in mandibular condylar cartilage. Therefore, we tested the hypothesis that such a dependency of the dynamic shear properties is present in mandibular condylar cartilage. From each of 17 condyles, two cartilage-bone plugs were dissected and t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.12.012

    authors: Tanaka E,Iwabuchi Y,Rego EB,Koolstra JH,Yamano E,Hasegawa T,Kawazoe A,Kawai N,Tanne K

    更新日期:2008-01-01 00:00:00

  • Identification of key events in baseball hitting using inertial measurement units.

    abstract::Quantification of baseball hitting mechanics under game conditions help players to become successful batters and prevent injuries. Inertial measurement units (IMUs) can measure motion without any spatial restriction and are thus becoming a popular tool to investigate sports biomechanics. Biomechanical analysis of hitt...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.02.001

    authors: Punchihewa NG,Yamako G,Fukao Y,Chosa E

    更新日期:2019-04-18 00:00:00

  • Experimental evaluation of local wave speed in the presence of reflected waves.

    abstract::Wave speed (also called pulse wave velocity) is the speed by which disturbance travels along the medium and it depends on the mechanical and geometrical properties of the vessel and on the density of the blood. Wave speed is a parameter of clinical relevance because it is an indicator of arterial stiffness and cardiov...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.10.007

    authors: Borlotti A,Li Y,Parker KH,Khir AW

    更新日期:2014-01-03 00:00:00

  • Thickness, cross-sectional area, and stiffness of intrinsic foot muscles affect performance in single-leg stance balance tests in healthy sedentary young females.

    abstract::The purpose of this study was to investigate the effect of thickness, cross-sectional area and stiffness of intrinsic foot muscles on performance in single-leg stance balance tasks in healthy sedentary young females. This study included a total of 40 healthy sedentary young females between the ages of 19 and 35 years....

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109530

    authors: Taş S,Ünlüer NÖ,Çetin A

    更新日期:2020-01-23 00:00:00

  • Turbulence model choice for the calculation of drag forces when using the CFD method.

    abstract::The aim of this work is to specify which model of turbulence is the most adapted in order to predict the drag forces that a swimmer encounters during his movement in the fluid environment. For this, a Computational Fluid Dynamics (CFD) analysis has been undertaken with a commercial CFD code (Fluent). The problem was m...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.010

    authors: Zaïdi H,Fohanno S,Taïar R,Polidori G

    更新日期:2010-02-10 00:00:00

  • Walking speed and spatiotemporal step mean measures are reliable during feedback-controlled treadmill walking; however, spatiotemporal step variability is not reliable.

    abstract::The purpose of the study was to compare the effects of a feedback-controlled treadmill (FeedbackTM) to a traditional fixed-speed treadmill (FixedTM) on spatiotemporal gait means, variability, and dynamics. The study also examined inter-session reliability when using the FeedbackTM. Ten young adults walked on the Feedb...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.11.051

    authors: Wiens C,Denton W,Schieber MN,Hartley R,Marmelat V,Myers SA,Yentes JM

    更新日期:2019-01-23 00:00:00

  • Alternative measures of toe trajectory more accurately predict the probability of tripping than minimum toe clearance.

    abstract::Tripping is responsible for a large percentage of falls. Minimum toe clearance (MTC) during the swing phase of gait is commonly used to infer the probability of tripping (POT). However, there is limited empirical evidence to support the relationship between these two variables, and other measures of toe trajectory may...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.10.045

    authors: Byju AG,Nussbaum MA,Madigan ML

    更新日期:2016-12-08 00:00:00

  • Virtual traumatology of pregnant women: the PRegnant car Occupant Model for Impact Simulations (PROMIS).

    abstract::This study report documents the development of a finite element (FE) model for analyzing trauma in pregnant women involved in road accidents and help the design of a specific safety device. The model is representative of a 50th percentile pregnant woman at 26 weeks of pregnancy in sitting position. To achieve this, th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.09.013

    authors: Auriault F,Thollon L,Peres J,Delotte J,Kayvantash K,Brunet C,Behr M

    更新日期:2014-01-03 00:00:00

  • Cellular force signal integration through vector logic gates.

    abstract::The multi-signal mechanical environment mammalian cells experience is often unaccounted for in current mechanical stimulation studies. To address this we developed a novel technique to induce dual integrated force inputs, uniaxial stretch and fluid shear stress and present here for the first time a vector logic-gate f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.12.047

    authors: Steward RL Jr,Tan C,Cheng CM,LeDuc PR

    更新日期:2015-02-26 00:00:00

  • Geometrical resolution limits and detection mechanisms in the oral cavity.

    abstract::The objective of this work is to gain more insight into the processes of oral perception of food texture. Particularly, the limits for detectable thickness differences of objects, which are evaluated in the human mouth, are investigated. In a sensory study small, flexible circular disks (diameter in mm range) of varyi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.04.012

    authors: Strassburg J,Burbidge A,Delgado A,Hartmann C

    更新日期:2007-01-01 00:00:00

  • Shoe midsole hardness, sex and age effects on lower extremity kinematics during running.

    abstract::Previous studies investigating the effects of shoe midsole hardness on running kinematics have often used male subjects from within a narrow age range. It is unknown whether shoe midsole hardness has the same kinematic effect on male and female runners as well as runners from different age categories. As sex and age h...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.03.027

    authors: Nigg BM,Baltich J,Maurer C,Federolf P

    更新日期:2012-06-01 00:00:00

  • Crack growth resistance in cortical bone: concept of microcrack toughening.

    abstract::The role of microcracking in cortical bone as a toughening mechanism has been investigated in conjunction with the variation in fracture toughness with crack length. Fracture toughness tests were conducted on miniaturised compact tension specimens made from human and bovine cortical bone and the resultant microstructu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00029-8

    authors: Vashishth D,Behiri JC,Bonfield W

    更新日期:1997-08-01 00:00:00

  • Walking at the preferred stride frequency maximizes local dynamic stability of knee motion.

    abstract::Healthy humans display a preference for walking at a stride frequency dependent on the inertial properties of their legs. Walking at preferred stride frequency (PSF) is predicted to maximize local dynamic stability, whereby sensitivity to intrinsic perturbations arising from natural variability inherent in biological ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.10.012

    authors: Russell DM,Haworth JL

    更新日期:2014-01-03 00:00:00

  • Torsional stiffness and strength of the proximal tibia are better predicted by finite element models than DXA or QCT.

    abstract::Individuals with spinal cord injury experience a rapid loss of bone mineral below the neurological lesion. The clinical consequence of this bone loss is a high rate of fracture around regions of the knee. The ability to predict the mechanical competence of bones at this location may serve as an important clinical tool...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.04.016

    authors: Edwards WB,Schnitzer TJ,Troy KL

    更新日期:2013-06-21 00:00:00

  • Predicting surface strains at the human distal radius during an in vivo loading task--finite element model validation and application.

    abstract::Bone strains resulting from physical activity are thought to be a primary driver of bone adaptation, but cannot be directly noninvasively measured. Because bone adapts nonuniformly, physical activity may make an important independent structural contribution to bone strength that is independent of bone mass and density...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.04.050

    authors: Bhatia VA,Edwards WB,Troy KL

    更新日期:2014-08-22 00:00:00

  • Hip contact forces and gait patterns from routine activities.

    abstract::In vivo loads acting at the hip joint have so far only been measured in few patients and without detailed documentation of gait data. Such information is required to test and improve wear, strength and fixation stability of hip implants. Measurements of hip contact forces with instrumented implants and synchronous ana...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00040-9

    authors: Bergmann G,Deuretzbacher G,Heller M,Graichen F,Rohlmann A,Strauss J,Duda GN

    更新日期:2001-07-01 00:00:00

  • Towards mechanical characterization of intact endarterectomy samples of carotid arteries during inflation using Echo-CT.

    abstract::In this study, an experimental framework is described that allows pressurization of intact, human atherosclerotic carotid samples (inflation testing), in combination with ultrasound imaging. Eight fresh human carotid endarterectomy samples were successfully pressurized and tested. About 36 2-D (+t) ultrasound datasets...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.01.016

    authors: Boekhoven RW,Rutten MC,van Sambeek MR,van de Vosse FN,Lopata RG

    更新日期:2014-03-03 00:00:00

  • On the permanent hip-stabilizing effect of atmospheric pressure.

    abstract::Hip joint dislocations related to total hip arthroplasty (THA) are a common complication especially in the early postoperative course. The surgical approach, the alignment of the prosthetic components, the range of motion and the muscle tone are known factors influencing the risk of dislocation. A further factor that ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.05.013

    authors: Prietzel T,Hammer N,Schleifenbaum S,Kaßebaum E,Farag M,von Salis-Soglio G

    更新日期:2014-08-22 00:00:00

  • Probabilistic finite element prediction of knee wear simulator mechanics.

    abstract::Computational models have recently been developed to replicate experimental conditions present in the Stanmore knee wear simulator. These finite element (FE) models, which provide a virtual platform to evaluate total knee replacement (TKR) mechanics, were validated through comparisons with experimental data for a spec...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.07.029

    authors: Laz PJ,Pal S,Halloran JP,Petrella AJ,Rullkoetter PJ

    更新日期:2006-01-01 00:00:00

  • Mechanisms relating force and high-frequency stiffness in skeletal muscle.

    abstract::Muscle stiffness increases faster than muscle force during the rising phase of a tetanic contraction, and decreases more slowly during the falling phase. Different models of the stiffness arising from series, parallels, and crossbridge elasticity were compared to determine whether they could account quantitatively for...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/0021-9290(90)90037-4

    authors: Bobet J,Stein RB,Oğuztöreli MN

    更新日期:1990-01-01 00:00:00

  • Using the loading response peak for defining gait cycle timing: A novel solution for the double-belt problem.

    abstract::Split-belt treadmills (SBTM) contain force plates under each belt that measure ground reaction force (GRF). Initial contact (IC) detection for each gait cycle obtained from the GRF is used for calculating temporal gait parameters (e.g., gait variability, step time, stride time). Occasionally, the participant steps wit...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109963

    authors: Ben-Gal O,Benady A,Zadik S,Doniger GM,Schnaider Beeri M,Plotnik M

    更新日期:2020-09-18 00:00:00

  • Reprogramming cardiomyocyte mechanosensing by crosstalk between integrins and hyaluronic acid receptors.

    abstract::The elastic modulus of bioengineered materials has a strong influence on the phenotype of many cells including cardiomyocytes. On polyacrylamide (PAA) gels that are laminated with ligands for integrins, cardiac myocytes develop well organized sarcomeres only when cultured on substrates with elastic moduli in the range...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.11.023

    authors: Chopra A,Lin V,McCollough A,Atzet S,Prestwich GD,Wechsler AS,Murray ME,Oake SA,Kresh JY,Janmey PA

    更新日期:2012-03-15 00:00:00

  • Micromechanical modeling of elastic properties of cortical bone accounting for anisotropy of dense tissue.

    abstract::The paper analyzes the connection between microstructure of the osteonal cortical bone and its overall elastic properties. The existing models either neglect anisotropy of the dense tissue or simplify cortical bone microstructure (accounting for Haversian canals only). These simplifications (related mostly to insuffic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.08.019

    authors: Salguero L,Saadat F,Sevostianov I

    更新日期:2014-10-17 00:00:00

  • Exploring the regional disc bulge response of the cervical porcine intervertebral disc under varying loads and posture.

    abstract::Nerve compression due to intervertebral disc (IVD) bulging is a known mechanism for low back pain and typically occurs in the posterior region of the disc. Most in vitro studies are limited in the ability to quantify the magnitude of bulging on the posterior aspect of the disc due to the boney structures that occlude ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109713

    authors: Fewster KM,Noguchi M,Gooyers CE,Wong A,Callaghan JP

    更新日期:2020-05-07 00:00:00

  • The effect on patellofemoral joint stability of selective cutting of lateral retinacular and capsular structures.

    abstract::Patient selection for lateral retinacular release (LRR) and its efficacy are controversial. Iatrogenic medial subluxation can occur with inappropriate LRR. The aim of this study was to determine the reduction in patellofemoral stability with progressively more extensive LRR. The force required to displace the patella ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.11.003

    authors: Merican AM,Kondo E,Amis AA

    更新日期:2009-02-09 00:00:00

  • Planar biaxial characterization of diseased human coronary and carotid arteries for computational modeling.

    abstract::Computational models have the potential to provide precise estimates of stresses and strains associated with sites of coronary plaque rupture. However, lack of adequate mathematical description of diseased human vessel wall mechanical properties is hindering computational accuracy. The goal of this study is to charact...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.11.019

    authors: Kural MH,Cai M,Tang D,Gwyther T,Zheng J,Billiar KL

    更新日期:2012-03-15 00:00:00

  • Time-frequency changes in electromyographic signals after hamstring lengthening surgery in children with cerebral palsy.

    abstract::Increased knee flexion during stance is a common gait deviation in the child with cerebral palsy (CP), with distal hamstring lengthening surgeries being an accepted course of treatment. Post-operatively, improvements in gait kinematics have been reported, however little change is noted in the patterns of muscle activi...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2007.01.001

    authors: Lauer RT,Smith BT,Shewokis PA,McCarthy JJ,Tucker CA

    更新日期:2007-01-01 00:00:00

  • Theoretical effects of fully ductile versus fully brittle behaviors of bone tissue on the strength of the human proximal femur and vertebral body.

    abstract::The influence of the ductility of bone tissue on whole-bone strength represents a fundamental issue of multi-scale biomechanics. To gain insight, we performed a computational study of 16 human proximal femurs and 12 T9 vertebral bodies, comparing the whole-bone strength for the two hypothetical bounding cases of fully...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.066

    authors: Nawathe S,Yang H,Fields AJ,Bouxsein ML,Keaveny TM

    更新日期:2015-05-01 00:00:00