Walking at the preferred stride frequency maximizes local dynamic stability of knee motion.

Abstract:

:Healthy humans display a preference for walking at a stride frequency dependent on the inertial properties of their legs. Walking at preferred stride frequency (PSF) is predicted to maximize local dynamic stability, whereby sensitivity to intrinsic perturbations arising from natural variability inherent in biological motion is minimized. Previous studies testing this prediction have employed different variability measures, but none have directly quantified local dynamic stability by computing maximum finite-time Lyapunov exponent (λ(Max)), which quantifies the rate of divergence of nearby trajectories in state space. Here, ten healthy adults walked 45 m overground while sagittal motion of both knees was recorded via electrogoniometers. An auditory metronome prescribed 7 different frequencies relative to each individual's PSF (PSF; ±5, ±10, ±15 strides/min). Stride frequencies were performed under both freely adopted speed (FS) and controlled speed (CS: set at the speed of PSF trials) conditions. Local dynamic stability was maximal (λ(Max) was minimal) at the PSF, becoming less stable for higher and lower stride frequencies. This occurred under both FS and CS conditions, although controlling speed further reduced local dynamic stability at non-preferred stride frequencies. In contrast, measures of variability revealed effects of stride frequency and speed conditions that were distinct from λ(Max). In particular, movement regularity computed by approximate entropy (ApEn) increased for slower walking speeds, appearing to depend on speed rather than stride frequency. The cadence freely adopted by humans has the benefit of maximizing local dynamic stability, which can be interpreted as humans tuning to their resonant frequency of walking.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Russell DM,Haworth JL

doi

10.1016/j.jbiomech.2013.10.012

subject

Has Abstract

pub_date

2014-01-03 00:00:00

pages

102-8

issue

1

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(13)00466-1

journal_volume

47

pub_type

杂志文章
  • Marker-less versus marker-based driven musculoskeletal models of the spine during static load-handling activities.

    abstract::Evaluation of workers' body posture in workstations is a prerequisite to estimate spinal loads and assess risk of injury for the subsequent design of preventive interventions. The Microsoft Kinect™ sensor is, in this regard, advantageous over the traditional skin-marker-based optical motion capture systems for being m...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110043

    authors: Asadi F,Arjmand N

    更新日期:2020-11-09 00:00:00

  • Analytical modeling of the instantaneous maximal transvalvular pressure gradient in aortic stenosis.

    abstract::In presence of aortic stenosis, a jet is produced downstream of the aortic valve annulus during systole. The vena contracta corresponds to the location where the cross-sectional area of the flow jet is minimal. The maximal transvalvular pressure gradient (TPG(max)) is the difference between the static pressure in the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.10.013

    authors: Garcia D,Kadem L,Savéry D,Pibarot P,Durand LG

    更新日期:2006-01-01 00:00:00

  • Comparison of blood particle deposition models for non-parallel flow domains.

    abstract::Adhesions of monocytes and platelets to a vascular surface, particularly in regions of flow stagnation, recirculation, and reattachment, are a significant initial event in a broad spectrum of particle-wall interactions that significantly influence the formation of stenotic lesions and mural thrombi. A number of approx...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00434-7

    authors: Worth Longest P,Kleinstreuer C

    更新日期:2003-03-01 00:00:00

  • Compression-induced damage and internal tissue strains are related.

    abstract::Prolonged mechanical loading of soft tissues adjacent to bony prominences can lead to degeneration of muscle tissue, resulting in a condition termed pressure-related deep tissue injury. This type of deep pressure ulcers can develop into a severe wound, associated with problematic healing and a variable prognosis. Limi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.09.016

    authors: Ceelen KK,Stekelenburg A,Loerakker S,Strijkers GJ,Bader DL,Nicolay K,Baaijens FP,Oomens CW

    更新日期:2008-12-05 00:00:00

  • Muscle fascicle and series elastic element length changes along the length of the human gastrocnemius during walking and running.

    abstract::Ultrasound imaging has recently been used to distinguish the length changes of muscle fascicles from those of the whole muscle tendon complex during real life movements. The complicated three-dimensional architecture of pennate muscles can however cause heterogeneity in the length changes along the length of a muscle....

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.10.035

    authors: Lichtwark GA,Bougoulias K,Wilson AM

    更新日期:2007-01-01 00:00:00

  • Quantitative assessment of trunk deformation during running.

    abstract::The trunk has a multi-segmental structure and is composed of the cervical, thoracic, and lumber spines and surrounding soft tissue elements; this allows flexible deformation during dynamic movements. The purpose of this study was to quantitatively assess trunk deformation during dynamic movement. Ten male subjects per...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.04.019

    authors: Kudo S,Fujimoto M,Isaka T,Nagano A

    更新日期:2017-07-05 00:00:00

  • Computational musculoskeletal modeling of compensatory movements in the upper limb.

    abstract::It is well documented that most upper limb amputees utilize compensatory movement strategies to accomplish everyday tasks when using a prosthetic device and that musculoskeletal complaints (MSCs) are more common in this population. However, little information is available on how the loss of distal degrees of freedom (...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109843

    authors: Reilly M,Kontson K

    更新日期:2020-07-17 00:00:00

  • Composition of the cement line and its possible mechanical role as a local interface in human compact bone.

    abstract::Human compact bone may be viewed as a fiber reinforced composite material in which the secondary osteons act as the fiber reinforcements. The cement line, which is the interface between the 'fibers' (osteons) and extraosteonal bone matrix, may impart important mechanical properties to compact bone. The nature of these...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90132-7

    authors: Burr DB,Schaffler MB,Frederickson RG

    更新日期:1988-01-01 00:00:00

  • A mechanistic damage model for ligaments.

    abstract:PURPOSE:The accuracy of biomechanical models is predicated on the realism by which they represent their biomechanical tissues. Unfortunately, most models use phenomenological ligament models that neglect the behaviour in the failure region. Therefore, the purpose of this investigation was to test whether a mechanistic ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.06.039

    authors: Barrett JM,Callaghan JP

    更新日期:2017-08-16 00:00:00

  • The use of a single sacral marker method to approximate the centre of mass trajectory during treadmill running.

    abstract::The three-dimensional trajectory of the body's centre of mass (COM) is useful to determine a number of biomechanical outcomes in running research. Previous studies have used the COM to calculate measures such as overstriding, vertical stiffness, and vertical oscillation. The COM is traditionally computed using the seg...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109886

    authors: Napier C,Jiang X,MacLean CL,Menon C,Hunt MA

    更新日期:2020-07-17 00:00:00

  • Understanding stress concentration about a nutrient foramen.

    abstract::We investigated the microstructural basis of a reduced stress concentration around the primary nutrient foramen of the equine third metacarpus. We quantified the spatial variations of compositional parameters (mineral content, volume fraction, histological architecture, and osteonal trajectories) from microradiographs...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00130-1

    authors: Götzen N,Cross AR,Ifju PG,Rapoff AJ

    更新日期:2003-10-01 00:00:00

  • Alteration of blood hemorheologic properties during cerebral ischemia and reperfusion in rats.

    abstract::The cerebral ischemia and reperfusion rat model was employed in this experiment to study the rheological properties (i.e. viscosity, hematocrit, red blood cell deformability and thixotropic properties) of whole blood. The results of this study show that a significant relation exists between the duration of cerebral is...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00180-9

    authors: Kuke D,Donghua L,Xiaoyan S,Yanjun Z

    更新日期:2001-02-01 00:00:00

  • Tissue and cellular morphological changes in growth plate explants under compression.

    abstract::The mechanisms by which mechanical loading may alter bone development within growth plates are still poorly understood. However, several growth plate cell or tissue morphological parameters are associated with both normal and mechanically modulated bone growth rates. The aim of this study was to quantify in situ the t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.05.010

    authors: Amini S,Veilleux D,Villemure I

    更新日期:2010-09-17 00:00:00

  • Three-dimensional finite element analysis of glass-ceramic dental crowns.

    abstract::Because of the improved esthetic potential of glass-ceramic crowns as dental restorations, they are sometimes preferred over metal-ceramic crowns for restoration of anterior teeth. Because of their relatively high strength, these ceramic crowns are also frequently used for restoration of posterior teeth. However, due ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90008-q

    authors: Hojjatie B,Anusavice KJ

    更新日期:1990-01-01 00:00:00

  • Hamstring muscle-tendon unit lengthening and activation in instep and cut-off kicking.

    abstract::Hamstring muscle strain injury is one of the most common injuries in sports involving sprinting and kicking. Studies examining hamstring kinematics and activations are rich for sprinting but lacking for kicking. The purpose of this study was to examine kinematics and activations of hamstring muscles in instep and cut-...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109482

    authors: Zhang L,Li H,Garrett WE,Liu H,Yu B

    更新日期:2020-01-23 00:00:00

  • Tribology studies of the natural knee using an animal model in a new whole joint natural knee simulator.

    abstract::The successful development of early-stage cartilage and meniscus repair interventions in the knee requires biomechanical and biotribological understanding of the design of the therapeutic interventions and their tribological function in the natural joint. The aim of this study was to develop and validate a porcine kne...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.07.043

    authors: Liu A,Jennings LM,Ingham E,Fisher J

    更新日期:2015-09-18 00:00:00

  • Reducing upper airway collapse at lower continuous positive airway titration pressure.

    abstract::During respiration, upper airway (UA) collapse occurs when the forces generated from the negative UA pressures exceed the forces produced by the UA muscles; which leads to loose soft tissue at the back of the mouth. At predetermined titration pressure, the Continuous Positive Airway Pressure (CPAP) normally provides a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.005

    authors: Ashaat S,Al-Jumaily AM

    更新日期:2016-12-08 00:00:00

  • Suitability of Kinect for measuring whole body movement patterns during exergaming.

    abstract::Exergames provide a challenging opportunity for home-based training and evaluation of postural control in the elderly population, but affordable sensor technology and algorithms for assessment of whole body movement patterns in the home environment are yet to be developed. The aim of the present study was to evaluate ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.07.017

    authors: van Diest M,Stegenga J,Wörtche HJ,Postema K,Verkerke GJ,Lamoth CJ

    更新日期:2014-09-22 00:00:00

  • Two mathematical models explain the variation in cystometrograms of obstructed urinary bladders.

    abstract::Overdistension of the urinary bladder, secondary to outlet obstruction, causes cellular changes in the bladder wall, including hypertrophy of the smooth muscle cells, which increase bladder mass. To investigate the effects of increased mass on the cystometrogram (CMG), we have developed two mathematical models. In the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:

    authors: Damaser MS,Lehman SL

    更新日期:1996-12-01 00:00:00

  • Gait in rheumatoid arthritis: an electrogoniometric investigation.

    abstract::For the purpose of detecting early aberrations of gait in rheumatoid arthritis 17 women suffering from that disease were examined. They were all under 50 years of age and had an essentially normal range of motility in the hips, knees and ankles. Eleven healthy women walking at voluntary speed and 6 healthy women walki...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90237-0

    authors: Isacson J,Broström LA

    更新日期:1988-01-01 00:00:00

  • A theoretical and non-destructive experimental approach for direct inclusion of measured collagen orientation and recruitment into mechanical models of the artery wall.

    abstract::Gradual collagen recruitment has been hypothesized as the underlying mechanism for the mechanical stiffening with increasing stress in arteries. In this work, we investigated this hypothesis in eight rabbit carotid arteries by directly measuring the distribution of collagen recruitment stretch under increasing circumf...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.11.016

    authors: Hill MR,Duan X,Gibson GA,Watkins S,Robertson AM

    更新日期:2012-03-15 00:00:00

  • Leaflet stress and strain distributions following incomplete transcatheter aortic valve expansion.

    abstract::Transcatheter aortic valve replacement (TAVR) is an established treatment alternative to surgical valve replacement in high-risk patients with severe symptomatic aortic stenosis. The current guidelines for TAVR are to upsize transcatheter aortic valve (TAV) relative to the native annulus to secure the device and minim...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.08.012

    authors: Abbasi M,Azadani AN

    更新日期:2015-10-15 00:00:00

  • Identification of key events in baseball hitting using inertial measurement units.

    abstract::Quantification of baseball hitting mechanics under game conditions help players to become successful batters and prevent injuries. Inertial measurement units (IMUs) can measure motion without any spatial restriction and are thus becoming a popular tool to investigate sports biomechanics. Biomechanical analysis of hitt...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.02.001

    authors: Punchihewa NG,Yamako G,Fukao Y,Chosa E

    更新日期:2019-04-18 00:00:00

  • A kinematic and strain gauge study of the reciprocal apparatus in the equine hind limb.

    abstract::Hind limb kinematics were recorded in five horses at walk and trot using an opto-electronic CODA-3 system. Simultaneously, in vivo strain in the completely tendinous peroneus tertius muscle was registered by implanted mercury-in-silastic strain gauges. The origin-insertion length patterns of the peroneus tertius were ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90284-8

    authors: van Weeren PR,Jansen MO,van den Bogert AJ,Barneveld A

    更新日期:1992-11-01 00:00:00

  • Torsional stiffness and strength of the proximal tibia are better predicted by finite element models than DXA or QCT.

    abstract::Individuals with spinal cord injury experience a rapid loss of bone mineral below the neurological lesion. The clinical consequence of this bone loss is a high rate of fracture around regions of the knee. The ability to predict the mechanical competence of bones at this location may serve as an important clinical tool...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.04.016

    authors: Edwards WB,Schnitzer TJ,Troy KL

    更新日期:2013-06-21 00:00:00

  • A dynamic model of the forearm including fatigue.

    abstract::A biomechanical model of the forearm, consisting of 61 muscle-tendon systems or tendons and 8 sections, is presented. The model can be used to calculate the muscle forces when resultant of the external forces and the motion is known. Calculations are based on constraints of muscle forces, joint forces, contact forces,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00009-4

    authors: Freund J,Takala EP

    更新日期:2001-05-01 00:00:00

  • Proximal femur elastic behaviour is the same in impact and constant displacement rate fall simulation.

    abstract::Understanding proximal femur fracture may yield new targets for fracture prevention screening and treatment. The goal of this study was to characterize force-displacement and failure behaviours in the proximal femur between displacement control and impact loading fall simulations. Twenty-one human proximal femurs were...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.06.040

    authors: Gilchrist S,Nishiyama KK,de Bakker P,Guy P,Boyd SK,Oxland T,Cripton PA

    更新日期:2014-11-28 00:00:00

  • A Hill type model of rat medial gastrocnemius muscle that accounts for shortening history effects.

    abstract::The aim of the present study was to develop a Hill type muscle model that accounts for the effects of shortening history. For this purpose, a function was derived that relates force depression to starting length, shortening amplitude and contraction velocity. History parameters were determined from short-range isokine...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00048-7

    authors: Meijer K,Grootenboer HJ,Koopman HF,van der Linden BJ,Huijing PA

    更新日期:1998-06-01 00:00:00

  • Humans control stride-to-stride stepping movements differently for walking and running, independent of speed.

    abstract::As humans walk or run, external (environmental) and internal (physiological) disturbances induce variability. How humans regulate this variability from stride-to-stride can be critical to maintaining balance. One cannot infer what is "controlled" based on analyses of variability alone. Assessing control requires quant...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.05.034

    authors: Dingwell JB,Bohnsack-McLagan NK,Cusumano JP

    更新日期:2018-07-25 00:00:00

  • Constrained least-squares optimization for robust estimation of center of rotation.

    abstract::This paper presents a new direct method for estimating the average center of rotation (CoR). An existing least-squares (LS) solution has been shown by previous works to have reduced accuracy for data with small range of motion (RoM). Alternative methods proposed to improve the CoR estimation use iterative algorithms. ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.05.010

    authors: Chang LY,Pollard NS

    更新日期:2007-01-01 00:00:00