Computational musculoskeletal modeling of compensatory movements in the upper limb.

Abstract:

:It is well documented that most upper limb amputees utilize compensatory movement strategies to accomplish everyday tasks when using a prosthetic device and that musculoskeletal complaints (MSCs) are more common in this population. However, little information is available on how the loss of distal degrees of freedom (DOFs) in the arm impact muscle force, thereby limiting our understanding of the mechanism by which these MSCs are manifesting. Knowledge of how a loss of DOFs may lead to MSCs can enable clinicians to provide more targeted guidance on how best to restore functional ability while addressing pain, and may serve as a tool for prescriptive decision-making when determining the impact of device selection on long-term clinical needs. 3D motion capture data were collected from 12 right-handed subjects with no upper limb disability using an 8-camera Vicon™ motion analysis system as they performed the targeted Box and Blocks test under normal and braced conditions to simulate a loss of DOFs in the wrist and fingers. Muscle force data were calculated using AnyBody Modeling Software™ for four different muscles: erector spinae, infraspinatus, deltoid, and trapezius. Linear mixed effects models were generated using the peak force data and mean force data for a given muscle fascicle. The fixed effect coefficient and 95% confidence intervals were reported for each muscle fascicle. Overall, a strong effect of condition on muscle force was seen for most muscles in the right side of the body (specifically deltoid and infraspinatus), with greater forces generated during the braced condition.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Reilly M,Kontson K

doi

10.1016/j.jbiomech.2020.109843

subject

Has Abstract

pub_date

2020-07-17 00:00:00

pages

109843

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(20)30266-9

journal_volume

108

pub_type

杂志文章
  • Cellular mechanobiology of the intervertebral disc: new directions and approaches.

    abstract::The more we learn about the intervertebral disc (IVD), the more we come to appreciate the intricacies involved in transmission of forces through the ECM to the cell, and in the biological determinants of its response to mechanical stress. This review highlights recent developments in our knowledge of IVD physiology an...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2009.09.019

    authors: Hsieh AH,Twomey JD

    更新日期:2010-01-05 00:00:00

  • The impact of boundary conditions on surface curvature of polypropylene mesh in response to uniaxial loading.

    abstract::Exposure following pelvic organ prolapse repair has been observationally associated with wrinkling of the implanted mesh. The purpose of this study was to quantify the impact of variable boundary conditions on the out-of-plane deformations of mesh subjected to tensile loading. Using photogrammetry and surface curvatur...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.061

    authors: Barone WR,Amini R,Maiti S,Moalli PA,Abramowitch SD

    更新日期:2015-06-25 00:00:00

  • Structural and mechanical properties of the human Achilles tendon: Sex and strength effects.

    abstract::Tendons are elastic structures that connect muscle to the skeletal system and transmit force relative to the amount of stretch they experience. The mechanical properties of human tendons are difficult to measure non-invasively, so generic values are often assumed in musculoskeletal models to represent all subjects. We...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.06.009

    authors: Morrison SM,Dick TJ,Wakeling JM

    更新日期:2015-09-18 00:00:00

  • Sagittal range of motion of the thoracic spine using inertial tracking device and effect of measurement errors on model predictions.

    abstract::Range of motion (ROM) of the thoracic spine has implications in patient discrimination for diagnostic purposes and in biomechanical models for predictions of spinal loads. Few previous studies have reported quite different thoracic ROMs. Total (T1-T12), lower (T5-T12) and upper (T1-T5) thoracic, lumbar (T12-S1), pelvi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.09.003

    authors: Hajibozorgi M,Arjmand N

    更新日期:2016-04-11 00:00:00

  • Strain imaging of the lateral collateral ligament using high frequency and conventional ultrasound imaging: An ex-vivo comparison.

    abstract::Recent first attempts of in situ ultrasound strain imaging in collateral ligaments encountered a number of challenges and illustrated a clear need for additional studies and more thorough validation of the available strain imaging methods. Therefore, in this study we experimentally validated ultrasound strain measurem...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.03.035

    authors: Gijsbertse K,Sprengers A,Naghibi Beidokhti H,Nillesen M,de Korte C,Verdonschot N

    更新日期:2018-05-17 00:00:00

  • Dynamic tensile properties of bovine periodontal ligament: A nonlinear viscoelastic model.

    abstract::As a support to the tooth, the mechanical response of the periodontal ligament (PDL) is complex. Like other connective tissues, the PDL exhibits non-linear and time-dependent behavior. The viscoelasticity of the PDL plays a significant role in low and high loading rates. Little information, however, is available on th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.02.020

    authors: Oskui IZ,Hashemi A

    更新日期:2016-03-21 00:00:00

  • Morphing methods to parameterize specimen-specific finite element model geometries.

    abstract::Shape plays an important role in determining the biomechanical response of a structure. Specimen-specific finite element (FE) models have been developed to capture the details of the shape of biological structures and predict their biomechanics. Shape, however, can vary considerably across individuals or change due to...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.08.036

    authors: Sigal IA,Yang H,Roberts MD,Downs JC

    更新日期:2010-01-19 00:00:00

  • Novel compact device for clinically measuring extraocular muscle (EOM) tension.

    abstract::Accurate knowledge of extraocular muscle (EOM) tension is important for the diagnosis of and surgical planning for strabismus, such as choosing which eye to operate or determining the amount of muscle displacement. Previous evaluations of passive EOM tension have relied extensively on the experience and skill of ophth...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109955

    authors: Shin HJ,Lee SJ,Oh CS,Kang H

    更新日期:2020-08-26 00:00:00

  • Validation of a calibration technique for 6-DOF instrumented spatial linkages.

    abstract::This paper presents a practical and effective approach to the calibration of instrumented spatial linkages for biomechanical applications. A 6-DOF mechanical linkage with rotational transducers is designed and in-house manufactured for this purpose. In order to assess the validity of the proposed calibration technique...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.06.021

    authors: Gatti G,Danieli G

    更新日期:2007-01-01 00:00:00

  • The relationship between elastic properties and microstructure of bovine cortical bone.

    abstract::The relationship between the structure of bone on the microscopic level and its mechanical properties was investigated by comparing bovine cortical bone of two microstructural types. Measurements of elastic properties were made in three orthogonal directions on specimens of plexiform and Haversian bone, taken from the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(84)90134-9

    authors: Lipson SF,Katz JL

    更新日期:1984-01-01 00:00:00

  • On the assumption of steadiness of nasal cavity flow.

    abstract::The unsteady flow through a model of the human nasal cavity is analyzed at a Strouhal number of Sr=0.791 for the complete respiration cycle. A comparison of the essential flow structures in the model geometry and a real nasal cavity shows the relevance of the model data. The analysis of the steady and unsteady solutio...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.12.008

    authors: Hörschler I,Schröder W,Meinke M

    更新日期:2010-04-19 00:00:00

  • Matrix mechanical properties of transversalis fascia in inguinal herniation as a model for tissue expansion.

    abstract::Inguinal herniation represents a common condition requiring surgical intervention. Despite being regarded as a connective tissue disorder of uncertain cause, research has focused predominantly on biochemical changes in the key tissue layer, the transversalis fascia (TF) with little direct analysis of functional tissue...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.08.018

    authors: Kureshi A,Vaiude P,Nazhat SN,Petrie A,Brown RA

    更新日期:2008-12-05 00:00:00

  • Comparison of acoustic characteristics predicted by Biot's theory and the modified Biot-Attenborough model in cancellous bone.

    abstract::Biot's theory and the modified Biot-Attenborough (MBA) model are applied to predict the dependences of acoustic characteristics on frequency and on porosity in cancellous bone. The phase velocities and the attenuation coefficients predicted by both theories are compared with the experimental data of bovine cancellous ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.12.004

    authors: Lee KI,Yoon SW

    更新日期:2006-01-01 00:00:00

  • A novel dual fluoroscopic imaging method for determination of THA kinematics: in-vitro and in-vivo study.

    abstract::Accurate measurement of six-degrees-of-freedom in-vivo kinematics of the total hip arthroplasty (THA) is essential in gaining insights into in-vivo THA performance. The objective of this study was to validate a novel dual fluoroscopy imaging system (DFIS) for determination of the THA kinematics using both in-vitro and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.02.010

    authors: Tsai TY,Li JS,Wang S,Lin H,Malchau H,Li G,Rubash H,Kwon YM

    更新日期:2013-04-26 00:00:00

  • Stress deprivation simultaneously induces over-expression of interleukin-1beta, tumor necrosis factor-alpha, and transforming growth factor-beta in fibroblasts and mechanical deterioration of the tissue in the patellar tendon.

    abstract::To test the hypothesis that stress deprivation induces over-expression of cytokines in the patellar tendon, 40 rats were divided into the following two groups. In the stress-shielded group, we slackened the patellar tendon in the right knee by drawing the patella toward the tibial tubercle with flexible wires. In the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.05.009

    authors: Uchida H,Tohyama H,Nagashima K,Ohba Y,Matsumoto H,Toyama Y,Yasuda K

    更新日期:2005-04-01 00:00:00

  • An analysis of the squeeze-film lubrication mechanism for articular cartilage.

    abstract::An asymptotic analysis of a lubrication problem is presented for a model of articular cartilage and synovial fluid under the squeeze-film condition. This model is based upon the following constitutive assumptions: (1) articular cartilage is a linear porous-permeable biphasic material filled with a linearly viscous flu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90024-u

    authors: Hou JS,Mow VC,Lai WM,Holmes MH

    更新日期:1992-03-01 00:00:00

  • Proximal femur elastic behaviour is the same in impact and constant displacement rate fall simulation.

    abstract::Understanding proximal femur fracture may yield new targets for fracture prevention screening and treatment. The goal of this study was to characterize force-displacement and failure behaviours in the proximal femur between displacement control and impact loading fall simulations. Twenty-one human proximal femurs were...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.06.040

    authors: Gilchrist S,Nishiyama KK,de Bakker P,Guy P,Boyd SK,Oxland T,Cripton PA

    更新日期:2014-11-28 00:00:00

  • Concurrent validity and reliability of a mobile tracking technology to measure angular and linear movements of the neck.

    abstract::The neck can be moved in six degrees of freedom. Current 3D-optoelectronic motion-capture systems capable of measuring these movements are inappropriate for use in clinical practice because they are stationary, expensive and time-consuming. We therefore developed a less complex 3D-tracking technology based on Steam®VR...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109340

    authors: Sommer BB,Weisenhorn M,Ernst MJ,Meichtry A,Rast FM,Kleger D,Schmid P,Lünenburger L,Bauer CM

    更新日期:2019-11-11 00:00:00

  • 3D kinematic and dynamic analysis of the front crawl tumble turn in elite male swimmers.

    abstract::The aim of this study was to identify kinematic and dynamic variables related to the best tumble turn times (3mRTT, the turn time from 3-m in to 3-m out, independent variable) in ten elite male swimmers using a three-dimensional (3D) underwater analysis protocol and the Lasso (least absolute shrinkage and selection op...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.11.043

    authors: Puel F,Morlier J,Avalos M,Mesnard M,Cid M,Hellard P

    更新日期:2012-02-02 00:00:00

  • Changes in segment mass and mass distribution during pregnancy.

    abstract::The purpose of the study was to evaluate the rates of change in the estimated masses and principal moments of inertia of the body segments during the second and third trimesters of pregnancy. Fifteen subjects, on average 15.1 weeks pregnant, were tested monthly until term. The body was modelled as 16 segments consisti...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00042-9

    authors: Jensen RK,Doucet S,Treitz T

    更新日期:1996-02-01 00:00:00

  • Upper limb joint kinetics during manual wheelchair propulsion in patients with different levels of spinal cord injury.

    abstract::The purpose of this study was to compare the forces and moments of the whole upper limb, analyzing forces and moments at the shoulder, elbow and wrist joints simultaneously during manual wheelchair propulsion of persons with different levels of spinal cord injury (SCI) on a treadmill. Fifty-one people participated in ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.05.021

    authors: Gil-Agudo A,Del Ama-Espinosa A,Pérez-Rizo E,Pérez-Nombela S,Pablo Rodríguez-Rodríguez L

    更新日期:2010-09-17 00:00:00

  • Microdamage accumulation in the cement layer of hip replacements under flexural loading.

    abstract::Mechanical fatigue of bone cement leading to damage accumulation is implicated in the loosening of cemented hip components. Even though cracks have been identified in autopsy-retrieved mantles, damage accumulation by continuous growth and increase in number of microcracks has not yet been demonstrated experimentally. ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00018-4

    authors: McCormack BA,Prendergast PJ

    更新日期:1999-05-01 00:00:00

  • Contribution of the skin, rectus abdominis and their sheaths to the structural response of the abdominal wall ex vivo.

    abstract::A better understanding of the abdominal wall biomechanics could help designing new treatments for incisional hernia. In the current study, an experimental protocol was developed to evaluate the contributions of the abdominal wall components to the structural response of the anterior part of the abdominal wall. The spe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.06.031

    authors: Tran D,Mitton D,Voirin D,Turquier F,Beillas P

    更新日期:2014-09-22 00:00:00

  • Tissue viscoelasticity is related to tissue composition but may not fully predict the apparent-level viscoelasticity in human trabecular bone - An experimental and finite element study.

    abstract::Trabecular bone is viscoelastic under dynamic loading. However, it is unclear how tissue viscoelasticity controls viscoelasticity at the apparent-level. In this study, viscoelasticity of cylindrical human trabecular bone samples (n=11, male, age 18-78 years) from 11 proximal femurs were characterized using dynamic and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.10.002

    authors: Ojanen X,Tanska P,Malo MKH,Isaksson H,Väänänen SP,Koistinen AP,Grassi L,Magnusson SP,Ribel-Madsen SM,Korhonen RK,Jurvelin JS,Töyräs J

    更新日期:2017-12-08 00:00:00

  • Optimal patterns for suturing wounds of complex shapes to foster healing.

    abstract::Stress is one of the many biological factors that plays an important role in wound healing. It is therefore essential to analyze stresses around the wound closure theoretically, especially when no invasive/noninvasive technique to measure stress directly is available. The objective of this paper is to determine the re...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00160-3

    authors: Lott-Crumpler DA,Chaudhry HR

    更新日期:2001-01-01 00:00:00

  • Estimating severity of sideways fall using a generic multi linear regression model based on kinematic input variables.

    abstract::Many research groups have studied fall impact mechanics to understand how fall severity can be reduced to prevent hip fractures. Yet, direct impact force measurements with force plates are restricted to a very limited repertoire of experimental falls. The purpose of this study was to develop a generic model for estima...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.01.033

    authors: van der Zijden AM,Groen BE,Tanck E,Nienhuis B,Verdonschot N,Weerdesteyn V

    更新日期:2017-03-21 00:00:00

  • The effect of sterilization on the dynamic mechanical properties of paired rabbit cortical bone.

    abstract::The optimal sterilization method for load bearing allografts remains a clinical concern. Recently, supercritical carbon dioxide (SCCO2) treatments have been shown to be capable of terminally sterilizing a range of bacteria and viruses, while preserving the static mechanical properties of cortical bone. This study eval...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.04.006

    authors: Russell N,Rives A,Bertollo N,Pelletier MH,Walsh WR

    更新日期:2013-06-21 00:00:00

  • Collagen fibril D-period may change as a function of strain and location in ligament.

    abstract::The purpose of this study was to determine if the characteristic banding pattern (D-period) of collagen fibrils from rabbit medial collateral ligaments changes as a function of gross ligament strain and, if so, whether the changes are location dependent (insertion versus midsubstance). Femur-medial collateral ligament...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00150-0

    authors: Kukreti U,Belkoff SM

    更新日期:2000-12-01 00:00:00

  • A comparison of reflection and transmission ultrasonic techniques for measurement of cancellous bone elasticity.

    abstract::A reflection ultrasonic technique, which offers several advantages over transmission ultrasonic techniques, has been described for elastic property measurement of bone. Ultrasonic velocities from specimens of cancellous bone were compared using a reflection ultrasound technique and the more traditional transmission ul...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90061-2

    authors: Ashman RB,Antich PP,Gonzales J,Anderson JA,Rho JY

    更新日期:1994-09-01 00:00:00

  • Three-dimensional intervertebral kinematics in the healthy young adult cervical spine during dynamic functional loading.

    abstract::The objective of this study was to determine the intervertebral kinematics of the young, healthy cervical spine during dynamic, three-dimensional, functional loading. Intervertebral motion was characterized by the range of motion (ROM) and the helical axis of motion (HAM). Biplane radiographs of the cervical spine wer...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.049

    authors: Anderst WJ,Donaldson WF 3rd,Lee JY,Kang JD

    更新日期:2015-05-01 00:00:00