Dynamic tensile properties of bovine periodontal ligament: A nonlinear viscoelastic model.

Abstract:

:As a support to the tooth, the mechanical response of the periodontal ligament (PDL) is complex. Like other connective tissues, the PDL exhibits non-linear and time-dependent behavior. The viscoelasticity of the PDL plays a significant role in low and high loading rates. Little information, however, is available on the short-term viscoelastic behavior of the PDL. Also, due to the highly non-linear stress-strain response, it was hypothesized that the dynamic viscoelastic properties of the PDL would be greatly dependent on the preload. Therefore, the present study was designed to explore the dynamic tensile properties of the bovine PDL as a function of loading frequency and preload. The in vitro dynamic tensile tests were performed over a wide range of frequencies (0.01-100Hz) with dynamic force amplitude of 1N and different preloads of 3, 5 and 10N. The generalized Maxwell model was utilized to describe the non-linear viscoelastic behavior of the PDL. The low loss factor of the bovine PDL, measured between 0.04 and 0.08, indicates low energy dissipation due to the high content of collagen fibers. Moreover, the influence of viscous components in the linear region of the stress-strain curve (10N preload) was lower than those of the toe region (3N preload). The data reported in this study could be used in developing accurate computational models of the PDL.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Oskui IZ,Hashemi A

doi

10.1016/j.jbiomech.2016.02.020

subject

Has Abstract

pub_date

2016-03-21 00:00:00

pages

756-764

issue

5

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(16)30163-4

journal_volume

49

pub_type

杂志文章
  • Validation of an ambient system for the measurement of gait parameters.

    abstract::Fall risk in elderly people is usually assessed using clinical tests. These tests consist in a subjective evaluation of gait performed by healthcare professionals, most of the time shortly after the first fall occurrence. We propose to complement this one-time, subjective evaluation, by a more quantitative analysis of...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.01.024

    authors: Dubois A,Bresciani JP

    更新日期:2018-03-01 00:00:00

  • Loading and deformation of the cat posterior knee joint capsule in axial and extension rotations.

    abstract::Deformation and loading of the knee posterior joint capsule were studied in the cat, in extension rotations and in axial external (ER) and internal (IR) rotations at full extension. Loads were measured in the ligament along the upper edge of the capsule, using mechanically sensitive neurons that were calibrated as loa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90352-f

    authors: Grigg P,Hoffman AH

    更新日期:1993-11-01 00:00:00

  • In vitro electro-mechanical characterization of human knee articular cartilage of different degeneration levels: a comparison with ICRS and Mankin scores.

    abstract::In the present study, the electro-mechanical properties of human knee articular cartilage were measured in vitro. An arthroscopic measurement tool was used to measure streaming potential integral (SPI), after which creep indentation tests were performed. Additionally, degradation level of the tissue was determined in ...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2013.02.004

    authors: Abedian R,Willbold E,Becher C,Hurschler C

    更新日期:2013-04-26 00:00:00

  • Evaluation of an aortic valve prosthesis: Fluid-structure interaction or structural simulation?

    abstract::Bio-inspired polymeric heart valves (PHVs) are excellent candidates to mimic the structural and the fluid dynamic features of the native valve. PHVs can be implanted as prosthetic alternative to currently clinically used mechanical and biological valves or as potential candidate for a minimally invasive treatment, lik...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.04.004

    authors: Luraghi G,Wu W,De Gaetano F,Rodriguez Matas JF,Moggridge GD,Serrani M,Stasiak J,Costantino ML,Migliavacca F

    更新日期:2017-06-14 00:00:00

  • Similarity in the fatigue behavior of trabecular bone across site and species.

    abstract::Within the context of improving knowledge of the structure-function relations for trabecular bone for cyclic loading, we hypothesized that the S-N curve for cyclic compressive loading of trabecular bone, after accounting for differences in monotonic strength behavior, does not depend on either site or species. Thirty-...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00245-8

    authors: Haddock SM,Yeh OC,Mummaneni PV,Rosenberg WS,Keaveny TM

    更新日期:2004-02-01 00:00:00

  • The effects of exterior boundary conditions on a internally heated tumor tissue with a thermoporoelastic model.

    abstract::Modeling flow field in tumor regions interstitial space is of primary importance, because of the importance of advection in macromolecule drug delivery. Its deformation has also to be taken into account because of the forces caused by the fluid; if the tumor region is not isothermal, this deformation can be also stron...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110122

    authors: Andreozzi A,Iasiello M,Netti PA

    更新日期:2020-12-02 00:00:00

  • Hip extension, knee flexion paradox: a new mechanism for non-contact ACL injury.

    abstract::Considering that an athlete performs at-risk sports activities countless times throughout the course of his or her career prior to the instance of anterior cruciate ligament (ACL) injury, one may conclude that non-contact ACL injury is a rare event. Nevertheless, the overall number of non-contact ACL injuries, both in...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.11.013

    authors: Hashemi J,Breighner R,Chandrashekar N,Hardy DM,Chaudhari AM,Shultz SJ,Slauterbeck JR,Beynnon BD

    更新日期:2011-02-24 00:00:00

  • The poro-elastic behaviour of the intervertebral disc: A new perspective on diurnal fluid flow.

    abstract::Diurnal disc height changes, due to fluid in- and outflow, are in equilibrium while daytime spinal loading is twice as long as night time rest. A direction-dependent permeability of the endplates, favouring inflow over outflow, reportedly explains this; however, fluid flow through the annulus fibrosus should be consid...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.11.041

    authors: Vergroesen PA,van der Veen AJ,Emanuel KS,van Dieën JH,Smit TH

    更新日期:2016-04-11 00:00:00

  • The role of synovial fluid filtration by cartilage in lubrication of synovial joints--II. Squeeze-film lubrication: homogeneous filtration.

    abstract::A mathematical model of synovial film filtration and synovial gel formation at normal approach of cartilage surfaces in the human hip joint is presented. The biphasic mixture model presented in Part I of this paper [Hlavácek, J. Biomechanics 26, (1993)] for synovial fluid and that of Mow and his collaborators [J. Biom...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90063-k

    authors: Hlavácek M

    更新日期:1993-10-01 00:00:00

  • Effects of broad frequency vibration on cultured osteoblasts.

    abstract::Bone is subjected in vivo to both high amplitude, low frequency strain, incurred by locomotion, and to low amplitude, broad frequency strain. The biological effects of low amplitude, broad frequency strain are poorly understood. To evaluate the effects of low amplitude strains ranging in frequency from 0 to 50 Hz on o...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00245-2

    authors: Tanaka SM,Li J,Duncan RL,Yokota H,Burr DB,Turner CH

    更新日期:2003-01-01 00:00:00

  • Reprogramming cardiomyocyte mechanosensing by crosstalk between integrins and hyaluronic acid receptors.

    abstract::The elastic modulus of bioengineered materials has a strong influence on the phenotype of many cells including cardiomyocytes. On polyacrylamide (PAA) gels that are laminated with ligands for integrins, cardiac myocytes develop well organized sarcomeres only when cultured on substrates with elastic moduli in the range...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.11.023

    authors: Chopra A,Lin V,McCollough A,Atzet S,Prestwich GD,Wechsler AS,Murray ME,Oake SA,Kresh JY,Janmey PA

    更新日期:2012-03-15 00:00:00

  • The effect of step-wise increased stretching on rat calvarial osteoblast collagen production.

    abstract::Mechanical forces regulate the function of bone cells. In this paper, the effects of cyclic stretching on osteoblasts derived from rat calvaria were studied at a magnitude occurring in physiological loaded bone tissue. A four-point bending apparatus was used to apply cyclic stretching on osteoblasts. Stretching at 500...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00237-9

    authors: Tang LL,Wang YL,Pan J,Cai SX

    更新日期:2004-01-01 00:00:00

  • Artery buckling analysis using a four-fiber wall model.

    abstract::Artery bent buckling has been suggested as a possible mechanism that leads to artery tortuosity, which is associated with aging, hypertension, atherosclerosis, and other pathological conditions. It is necessary to understand the relationship between microscopic wall structural changes and macroscopic artery buckling b...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.06.005

    authors: Liu Q,Wen Q,Mottahedi M,Han HC

    更新日期:2014-08-22 00:00:00

  • A technique for the tensile testing of demineralised bone.

    abstract::The purpose of this study was to devise a method for the tensile testing of the organic component of demineralised bone. It was hoped that the method could be applied to determine whether an observed reduction in the strength of bone in copper-deficient rats could be attributed to a reduction in the cross-linking of c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90365-l

    authors: Jonas J,Burns J,Abel EW,Cresswell MJ,Strain JJ,Paterson CR

    更新日期:1993-03-01 00:00:00

  • Accuracy of a video strain measurement system.

    abstract::The purpose of this study was to determine the accuracy of a video system which our laboratory has been using to measure soft tissue strain. Both static and dynamic error analyses were performed to assess the accuracy of our video system. Static error was defined as the amount of movement reported by the video system ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00131-x

    authors: Smutz WP,Drexler M,Berglund LJ,Growney E,An KN

    更新日期:1996-06-01 00:00:00

  • Micromechanical modeling of elastic properties of cortical bone accounting for anisotropy of dense tissue.

    abstract::The paper analyzes the connection between microstructure of the osteonal cortical bone and its overall elastic properties. The existing models either neglect anisotropy of the dense tissue or simplify cortical bone microstructure (accounting for Haversian canals only). These simplifications (related mostly to insuffic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.08.019

    authors: Salguero L,Saadat F,Sevostianov I

    更新日期:2014-10-17 00:00:00

  • Hamstring muscle-tendon unit lengthening and activation in instep and cut-off kicking.

    abstract::Hamstring muscle strain injury is one of the most common injuries in sports involving sprinting and kicking. Studies examining hamstring kinematics and activations are rich for sprinting but lacking for kicking. The purpose of this study was to examine kinematics and activations of hamstring muscles in instep and cut-...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109482

    authors: Zhang L,Li H,Garrett WE,Liu H,Yu B

    更新日期:2020-01-23 00:00:00

  • Photogrammetric technique applied to anthropometric study of hands.

    abstract::Being concerned with physical anthropometric dimensions to explore avenues of research on hands and their working strategies, a research study was made to develop a suitable method by using available photogrammetric resources. The paper discusses the optimums of details found by this study, viz., the use of a Wild C-4...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90039-x

    authors: Ghosh SK,Poirier F

    更新日期:1987-01-01 00:00:00

  • Prediction of distal radius fracture in children, using a biomechanical impact model and case-control data on playground free falls.

    abstract:OBJECTIVES:To assess the ability of a biomechanical impact model to predict the likelihood of distal radius fracture in children using data gathered for a previous epidemiological case-control study of falls from playground equipment. METHODOLOGY:Factor of Risk (FR) values were generated for each of selected subjects ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.11.028

    authors: Davidson PL,Chalmers DJ,Stephenson SC

    更新日期:2006-01-01 00:00:00

  • Volume effects on fatigue life of equine cortical bone.

    abstract::Materials, including bone, often fail due to loading in the presence of critical flaws. The relative amount, location, and interaction of these flaws within a stressed volume of material play a role in determining the failure properties of the structure. As materials are generally imperfect, larger volumes of material...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.05.025

    authors: Bigley RF,Gibeling JC,Stover SM,Hazelwood SJ,Fyhrie DP,Martin RB

    更新日期:2007-01-01 00:00:00

  • Measurements of the three-dimensional shape of the rib cage.

    abstract::A stereoradiographic method was developed to measure the three-dimensional shape of the rib cage in vivo in order to provide descriptive data and to study symmetry in the normal population. The method is also intended for use in description of rib asymmetry in scoliosis. Rib midlines were reconstructed from digitized ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90127-3

    authors: Dansereau J,Stokes IA

    更新日期:1988-01-01 00:00:00

  • Towards the modelling of ageing and atherosclerosis effects in ApoE(-/-) mice aortic tissue.

    abstract::The goal of this work consists in a quantitative analysis and constitutive modelling of ageing processes associated to plaque formation in mice arteries. Reliable information on the characteristic evolution of pressure-stretch curves due to the ageing effects is extracted from previous inflation test experiments. Furt...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.01.043

    authors: Waffenschmidt T,Cilla M,Sáez P,Pérez MM,Martínez MA,Menzel A,Peña E

    更新日期:2016-08-16 00:00:00

  • Upper limb joint kinetics during manual wheelchair propulsion in patients with different levels of spinal cord injury.

    abstract::The purpose of this study was to compare the forces and moments of the whole upper limb, analyzing forces and moments at the shoulder, elbow and wrist joints simultaneously during manual wheelchair propulsion of persons with different levels of spinal cord injury (SCI) on a treadmill. Fifty-one people participated in ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.05.021

    authors: Gil-Agudo A,Del Ama-Espinosa A,Pérez-Rizo E,Pérez-Nombela S,Pablo Rodríguez-Rodríguez L

    更新日期:2010-09-17 00:00:00

  • Pure moment testing for spinal biomechanics applications: Fixed versus sliding ring cable-driven test designs.

    abstract::In vitro multi-axial bending testing using pure moment loading conditions has become the standard in evaluating the effects of different types of surgical intervention on spinal kinematics. Simple, cable-driven experimental set-ups have been widely adopted because they require little infrastructure. Traditionally, "fi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.02.004

    authors: Eguizabal J,Tufaga M,Scheer JK,Ames C,Lotz JC,Buckley JM

    更新日期:2010-05-07 00:00:00

  • The influence of center-of-mass movements on the variation in the structure of human postural sway.

    abstract::The present article investigates the influence of center-of-mass movements on the variation of the structure in human postural sway. Twelve healthy younger persons performed 60s quiet standing, 60s relaxed standing, and 10 min relaxed standing on two force plates. Center-of-pressure (CoP) and gravitational line (GL) p...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.10.016

    authors: Ihlen EA,Skjæret N,Vereijken B

    更新日期:2013-02-01 00:00:00

  • Longitudinal strain of canine and porcine aortas.

    abstract::The in situ longitudinal strain of canine and porcine aortas was investigated. Marks of black water-resistant ink were placed on the aortas and the axial lengths between the marks were measured in situ and in vitro. When the aortas were cut, the retraction was measured and described by the stretch ratio, which is defi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)00091-h

    authors: Han HC,Fung YC

    更新日期:1995-05-01 00:00:00

  • The between-day reliability of peroneus longus EMG during walking.

    abstract::The peroneus longus (PL) is a rearfoot evertor, important in frontal plane foot motion. Studying PL function has been limited by previous electromyography (EMG) studies reporting poor between-day reliability. Due to its close proximity to adjacent muscles, EMG measures of PL may be susceptible to crosstalk, thus corre...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.01.037

    authors: Reeves J,Jones R,Liu A,Bent L,Nester C

    更新日期:2019-03-27 00:00:00

  • Evaluation of human nasal cartilage nonlinear and rate dependent mechanical properties.

    abstract::Nasal reconstruction frequently requires donor cartilage and tissue, and ideally, donor tissue will closely emulate native nasal cartilage mechanics. Tissue engineering scaffolds, especially 3D printed scaffolds, have been proposed for nasal reconstruction, and the success of these constructs may depend on how well sc...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109549

    authors: Chang B,Reighard C,Flanagan C,Hollister S,Zopf D

    更新日期:2020-02-13 00:00:00

  • Plantar pressures in identical and non-identical twins.

    abstract::Identifying environmental risk factors for musculoskeletal disorders is challenging due to the number of potential confounders. Twins are of particular interest for researchers interested in studying these types of problems due to their inherent control for the influence of genetic factors. In twin studies, this popul...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.01.059

    authors: Telfer S,Bigham JJ,Sudduth ASM

    更新日期:2019-03-27 00:00:00

  • Variables during swing associated with decreased impact peak and loading rate in running.

    abstract::When the foot impacts the ground in running, large forces and loading rates can arise that may contribute to the development of overuse injuries. Investigating which biomechanical factors contribute to these impact loads and loading rates in running could assist clinicians in developing strategies to reduce these load...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.10.026

    authors: Schmitz A,Pohl MB,Woods K,Noehren B

    更新日期:2014-01-03 00:00:00