Towards the modelling of ageing and atherosclerosis effects in ApoE(-/-) mice aortic tissue.

Abstract:

:The goal of this work consists in a quantitative analysis and constitutive modelling of ageing processes associated to plaque formation in mice arteries. Reliable information on the characteristic evolution of pressure-stretch curves due to the ageing effects is extracted from previous inflation test experiments. Furthermore, characteristic age-dependent material parameters are identified on the basis of a continuum-mechanics-based parameter optimisation technique. The results indicate that the aorta-stiffness of the healthy control mice remains basically constant irrespective of the diet-time and age. In contrast, significant differences exist within the material response and in consequence within the material parameters between the ApoE(-/-) and the control mice as well as for the different locations over the aorta which is underlined by our experimental observations. With regard to the temporal evolution of the material parameters, we observe that the material parameters for the ApoE(-/-) mice aortas exhibit a saturation-type increase with respect to age.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Waffenschmidt T,Cilla M,Sáez P,Pérez MM,Martínez MA,Menzel A,Peña E

doi

10.1016/j.jbiomech.2016.01.043

subject

Has Abstract

pub_date

2016-08-16 00:00:00

pages

2390-7

issue

12

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(16)30126-9

journal_volume

49

pub_type

杂志文章
  • Comparison of partial least squares regression and principal component regression for pelvic shape prediction.

    abstract::This paper studied two different regression techniques for pelvic shape prediction, i.e., the partial least square regression (PLSR) and the principal component regression (PCR). Three different predictors such as surface landmarks, morphological parameters, or surface models of neighboring structures were used in a c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.11.005

    authors: Schumann S,Nolte LP,Zheng G

    更新日期:2013-01-04 00:00:00

  • Modeling the impact of concomitant aortic stenosis and coarctation of the aorta on left ventricular workload.

    abstract::Coarctation of the aorta (COA) is an obstruction of the aorta and is usually associated with bicuspid and tricuspid aortic valve stenosis (AS). When COA coexists with AS, the left ventricle (LV) is facing a double hemodynamic load: a valvular load plus a vascular load. The objective of this study was to develop a lump...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.08.001

    authors: Keshavarz-Motamed Z,Garcia J,Pibarot P,Larose E,Kadem L

    更新日期:2011-11-10 00:00:00

  • Micro-computed tomography assisted distal femur metaphyseal blunt punch compression for determining trabecular bone strength in mice.

    abstract::Shorter generation time and the power of genetic manipulation make mice an ideal model system to study bone biology as well as bone diseases. However their small size presents a challenge to perform strength measurements, particularly of the weight-bearing cancellous bone in the murine long bones. We recently develope...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.02.040

    authors: Sankar U,Pritchard ZJ,Voor MJ

    更新日期:2016-05-03 00:00:00

  • Automatic selection of a representative trial from multiple measurements using Principle Component Analysis.

    abstract::Experimental data in human movement science commonly consist of repeated measurements under comparable conditions. One can face the question how to identify a single trial, a set of trials, or erroneous trials from the entire data set. This study presents and evaluates a Selection Method for a Representative Trial (SM...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.06.012

    authors: Schweizer K,Cattin PC,Brunner R,Müller B,Huber C,Romkes J

    更新日期:2012-08-31 00:00:00

  • 'Equivalent geometry' of the knee and the prediction of tensions along the cruciates: an experimental study.

    abstract::In this paper we introduce the concept of the functional (or equivalent) geometry of the knee, which is an attempt to reduce the natural knee with its complex geometry, frictional resistance and deformable cartilage into a two-dimensional joint comprising rigid femur and tibia in frictionless contact. An apparatus and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00141-9

    authors: Chan SC,Seedhom BB

    更新日期:1999-01-01 00:00:00

  • Load transfer across the pelvic bone.

    abstract::Earlier experimental and finite element studies notwithstanding, the load transfer and stress distribution in the pelvic bone and the acetabulum in normal conditions are not well understood. This hampers the development of orthopaedic reconstruction methods. The present study deals with more precise finite element ana...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)00125-n

    authors: Dalstra M,Huiskes R

    更新日期:1995-06-01 00:00:00

  • Transient body sway characteristics during single-leg quiet stance in ballet dancers and young adults.

    abstract::This study explored transient characteristics of body sway during single-leg quiet stance in young ballet dancers (n = 41) and young healthy adults (n = 58). We compared the groups in terms of center of pressure (CoP) parameters (CoP velocity and amplitude, averaged across the duration of the 30-s trial), and the tran...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110195

    authors: Kozinc Ž,Šarabon N

    更新日期:2021-01-22 00:00:00

  • Lubricin deficiency in the murine lumbar intervertebral disc results in elevated torsional apparent modulus.

    abstract::The purpose of this study was to investigate the mechanical consequences of proteoglycan 4 (Prg4) deficiency on intervertebral disc mechanics using a Prg4 knockout mouse model. Prg4, also called lubricin, was first identified as the boundary lubricant in synovial fluid but has subsequently been localized within a numb...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.03.029

    authors: Teeple E,Aslani K,Shalvoy MR,Medrano JE,Zhang L,Machan JT,Fleming BC,Jay GD

    更新日期:2015-07-16 00:00:00

  • Hemiarthroplasty of hip joint: An experimental validation using porcine acetabulum.

    abstract::Biphasic properties of articular cartilage allow it to be an excellent bearing material and have been studied through several simplified experiments as well as finite element modelling. However, three-dimensional biphasic finite element (FE) models of the whole joint are rare. The current study was carried out to expe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.02.140

    authors: Pawaskar SS,Grosland NM,Ingham E,Fisher J,Jin Z

    更新日期:2011-05-17 00:00:00

  • Comparison of blood particle deposition models for non-parallel flow domains.

    abstract::Adhesions of monocytes and platelets to a vascular surface, particularly in regions of flow stagnation, recirculation, and reattachment, are a significant initial event in a broad spectrum of particle-wall interactions that significantly influence the formation of stenotic lesions and mural thrombi. A number of approx...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00434-7

    authors: Worth Longest P,Kleinstreuer C

    更新日期:2003-03-01 00:00:00

  • An ocular biomechanic model for dynamic simulation of different eye movements.

    abstract::Simulating and analysing eye movement is useful for assessing visual system contribution to discomfort with respect to body movements, especially in virtual environments where simulation sickness might occur. It can also be used in the design of eye prosthesis or humanoid robot eye. In this paper, we present two biome...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.02.006

    authors: Iskander J,Hossny M,Nahavandi S,Del Porto L

    更新日期:2018-04-11 00:00:00

  • The vesico-urethral pressuregram analysis of urethral function under stress.

    abstract::About one-third of older multiparous women are prone to stress urinary incontinence (SUI): unwanted urine loss during activities which suddenly raise intra-abdominal pressure. In this paper we describe and test a method for visualizing and analyzing the function of the urinary continence control system (CCS) under str...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)81291-2

    authors: Kim KJ,Ashton-Miller JA,Strohbehn K,DeLancey JO,Schultz AB

    更新日期:1997-01-01 00:00:00

  • Evidence of isometric function of the flexor hallucis longus muscle in normal gait.

    abstract::Studying mechanics of the muscles spanning multiple joints provides insights into intersegmental dynamics and movement coordination. Multiarticular muscles are thought to function at "near-isometric" lengths to transfer mechanical energy between the adjacent body segments. Flexor hallucis longus (FHL) is a multiarticu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.03.040

    authors: Kirane YM,Michelson JD,Sharkey NA

    更新日期:2008-01-01 00:00:00

  • Impact of transversal calf muscle loading on plantarflexion.

    abstract::Muscle compression commonly occurs in daily life (for instance wearing backpacks or compression garments, and during sitting). However, the effects of the compression on contraction dynamics in humans are not well examined. The aim of the study was to quantify the alterations of contraction dynamics and muscle archite...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.01.011

    authors: Stutzig N,Ryan D,Wakeling JM,Siebert T

    更新日期:2019-03-06 00:00:00

  • Jet collisions and vortex reversal in the human left ventricle.

    abstract::Unnatural dynamics of the notorious vortex in the left ventricle is often associated with cardiac disease. Understanding how different cardiac diseases alter the flow physics in the left ventricle may therefore provide a powerful tool for disease detection. In this work, the fluid dynamics in the left ventricle subjec...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.07.023

    authors: Di Labbio G,Kadem L

    更新日期:2018-09-10 00:00:00

  • Large deforming buoyant embolus passing through a stenotic common carotid artery: a computational simulation.

    abstract::Arterial embolism is responsible for the death of lots of people who suffers from heart diseases. The major risk of embolism in upper limbs is that the ruptured particles are brought into the brain, thus stimulating neurological symptoms or causing the stroke. We presented a computational model using fluid-structure i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.01.020

    authors: Vahidi B,Fatouraee N

    更新日期:2012-04-30 00:00:00

  • On the assumption of steadiness of nasal cavity flow.

    abstract::The unsteady flow through a model of the human nasal cavity is analyzed at a Strouhal number of Sr=0.791 for the complete respiration cycle. A comparison of the essential flow structures in the model geometry and a real nasal cavity shows the relevance of the model data. The analysis of the steady and unsteady solutio...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.12.008

    authors: Hörschler I,Schröder W,Meinke M

    更新日期:2010-04-19 00:00:00

  • Virtual traumatology of pregnant women: the PRegnant car Occupant Model for Impact Simulations (PROMIS).

    abstract::This study report documents the development of a finite element (FE) model for analyzing trauma in pregnant women involved in road accidents and help the design of a specific safety device. The model is representative of a 50th percentile pregnant woman at 26 weeks of pregnancy in sitting position. To achieve this, th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.09.013

    authors: Auriault F,Thollon L,Peres J,Delotte J,Kayvantash K,Brunet C,Behr M

    更新日期:2014-01-03 00:00:00

  • A finite viscoelastic-plastic model for describing the uniaxial ratchetting of soft biological tissues.

    abstract::In this paper, a phenomenological constitutive model is constructed to describe the uniaxial ratchetting (i.e., the cyclic accumulation of inelastic deformation) of soft biological tissues in the framework of finite viscoelastic-plasticity. The model is derived from a polyconvex elastic free energy function and addres...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.01.004

    authors: Zhu Y,Kang G,Kan Q,Yu C

    更新日期:2014-03-21 00:00:00

  • A mathematical model to investigate the effects of intravenous fluid administration and fluid loss.

    abstract::The optimal fluid administration protocol for critically ill perioperative patients is hard to estimate due to the lack of tools to directly measure the patient fluid status. This results in the suboptimal clinical outcome of interventions. Previously developed predictive mathematical models focus on describing the fl...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.03.002

    authors: Rosalina TT,Bouwman RA,van Sambeek MRHM,van de Vosse FN,Bovendeerd PHM

    更新日期:2019-05-09 00:00:00

  • Modeling aqueous humor collection from the human eye.

    abstract::Glaucoma is a common cause of blindness. Studies of this disease can involve collection of aqueous humor (AH) fluid from eyes of patients undergoing surgery, which involves aspirating a small fluid volume from the anterior region of the eye through a fine-bore needle. Unfortunately, the composition of the AH is spatia...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.07.025

    authors: Kapnisis K,Doormaal MV,Ross Ethier C

    更新日期:2009-11-13 00:00:00

  • Photogrammetric technique applied to anthropometric study of hands.

    abstract::Being concerned with physical anthropometric dimensions to explore avenues of research on hands and their working strategies, a research study was made to develop a suitable method by using available photogrammetric resources. The paper discusses the optimums of details found by this study, viz., the use of a Wild C-4...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90039-x

    authors: Ghosh SK,Poirier F

    更新日期:1987-01-01 00:00:00

  • The development of an improved physical surrogate model of the human spinal cord--tension and transverse compression.

    abstract::To prevent spinal cord injury, optimize treatments for it, and better understand spinal cord pathologies such as spondylotic myelopathy, the interaction between the spinal column and the spinal cord during injury and pathology must be understood. The spinal cord is a complex and very soft tissue that changes propertie...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.01.036

    authors: Kroeker SG,Morley PL,Jones CF,Bilston LE,Cripton PA

    更新日期:2009-05-11 00:00:00

  • Index-matched measurements of the effect of cartilaginous rings on tracheobronchial flow.

    abstract::We present a comparison of the flow characteristics in an idealized smooth trachea model and a second model which has a roughness simulating cartilaginous rings. We use refractive index-matched particle image velocimetry (PIV) to measure the velocity field in a two-generation model of the trachea and main bronchi. The...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.043

    authors: Bocanegra Evans H,Castillo L

    更新日期:2016-06-14 00:00:00

  • Ambulatory measurement of the knee adduction moment in patients with osteoarthritis of the knee.

    abstract::High knee joint-loading increases the risk and progression of knee osteoarthritis (OA). Mechanical loading on the knee is reflected in the external knee adduction moment (KAdM) that can be measured during gait with laboratory-based measurement systems. However, clinical application of these systems is limited. Ambulat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.09.030

    authors: van den Noort JJ,van der Esch M,Steultjens MP,Dekker J,Schepers MH,Veltink PH,Harlaar J

    更新日期:2013-01-04 00:00:00

  • Elastic area compressibility of the rabbit aorta.

    abstract::In this paper, we apply the micropipette to reduce the surface area of the rabbit aorta, and the relationship between the fractional area change of the aortic surface and the negative pressure in the pipette is studied. The experimental results for seven rabbit thoracic aortas show that the relationship can be express...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)00003-6

    authors: Yu Q,Wang X,Li G

    更新日期:1996-08-01 00:00:00

  • Trunk stiffness and dynamics during active extension exertions.

    abstract::Spinal stability is related to the recruitment and control of active muscle stiffness. Stochastic system identification techniques were used to calculate the effective stiffness and dynamics of the trunk during active trunk extension exertions. Twenty-one healthy adult subjects (10 males, 11 females) wore a harness wi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.09.014

    authors: Moorhouse KM,Granata KP

    更新日期:2005-10-01 00:00:00

  • Modeling the mechanical properties of liver fibrosis in rats.

    abstract::The progression of liver fibrosis changes the biomechanical properties of liver tissue. This study characterized and compared different liver fibrosis stages in rats in terms of viscoelasticity. Three viscoelastic models, the Voigt, Maxwell, and Zener models, were applied to experimental data from rheometer tests and ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.013

    authors: Zhu Y,Chen X,Zhang X,Chen S,Shen Y,Song L

    更新日期:2016-06-14 00:00:00

  • Backside nonconformity and locking restraints affect liner/shell load transfer mechanisms and relative motion in modular acetabular components for total hip replacement.

    abstract::Nonconformity between the polyethylene liner and the metal shell may exist in modular acetabular components by design, due to manufacturing tolerances, or from locking mechanisms that attach the polyethylene liner to the metal shell. Relative motion at the liner/shell interface has been associated with backside wear, ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00030-x

    authors: Kurtz SM,Ochoa JA,White CV,Srivastav S,Cournoyer J

    更新日期:1998-05-01 00:00:00

  • Effects of fixation and preservation on tissue elastic properties measured by quantitative optical coherence elastography (OCE).

    abstract::Fixed and preserved tissues have been massively used in the development of biomedical equipment and instrumentation. Not only the tissue morphology, but also its mechanical properties need to be considered in the fixation and preservation procedures since mechanical properties have significant influence on the design ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.02.013

    authors: Ling Y,Li C,Feng K,Duncan R,Eisma R,Huang Z,Nabi G

    更新日期:2016-05-03 00:00:00