Abstract:
:The purpose of this study was to determine the accuracy of a video system which our laboratory has been using to measure soft tissue strain. Both static and dynamic error analyses were performed to assess the accuracy of our video system. Static error was defined as the amount of movement reported by the video system for markers that were stationary. Dynamic error was defined as the difference between the motion of the markers as reported by the video system and their actual motion. Two sets of fluorescent markers were attached to a servo-hydraulic materials test machine. One marker set was attached to the hydraulic actuator (moving markers) and the other set was attached to the base of the machine (stationary markers). Five different marker sizes, five camera distances, and seven different loading rates were studied. Results indicated that the static error was independent of marker size, and that the dynamic error was independent of the loading rate and marker size for loading rates of 50% of the camera field of view (CFV) per second or slower. For loading rates greater than 50 percent of CFV per second, the marker size did have an affect on the dynamic error. The mean static error was found to be 0.026 percent of CFV and the mean dynamic error was found to be 0.062 percent of CFV.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Smutz WP,Drexler M,Berglund LJ,Growney E,An KNdoi
10.1016/0021-9290(95)00131-xsubject
Has Abstractpub_date
1996-06-01 00:00:00pages
813-7issue
6eissn
0021-9290issn
1873-2380pii
0021-9290(95)00131-Xjournal_volume
29pub_type
杂志文章abstract::Insects have evolved mechanical form and function over millions of years. Ants, in particular, can lift and carry heavy loads relative to their body mass. Loads are lifted with the mouthparts, transferred through the neck joint to the thorax, and distributed over six legs and tarsi (feet) that anchor to the supporting...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.10.053
更新日期:2014-01-22 00:00:00
abstract::The feasibility of determining biphasic material properties using regression models was investigated. A transversely isotropic poroelastic finite element model of stress relaxation was developed and validated against known results. This model was then used to simulate load intensity for a wide range of material proper...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.05.028
更新日期:2013-07-26 00:00:00
abstract::A three-dimensional finite element model of the human head is presented. The model has been validated against two sets of experimental results. To assess injury likelihood of the head subjected to impact loading, the structural intensity (SI) methodology is introduced in accordance with the prevailing practice in expe...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.11.015
更新日期:2006-01-01 00:00:00
abstract::A three-dimensional model of the lower limb containing 47 muscles was developed to study the differences between a two- and three-dimensional approach for determining internal loads, the role of the dynamic joint representation, and the behavior of different load-bearing criteria in walking and running. The problem of...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(97)00089-4
更新日期:1997-11-01 00:00:00
abstract::Traumatic damage to the brainstem occurs frequently when the brain skull complex experiences injurious loading especially during those traumatic situations that produce diffuse axonal injury (DAI). DAI has been shown to be dependent on load direction and correlated with regional tissue deformation in response to rotat...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(98)00068-2
更新日期:1998-09-01 00:00:00
abstract::There are many diseases which cause detrimental changes in the trabecular structure of cancellous bone, leading to mechanical failure of the tissue. One approach to understanding the mechanisms of these diseases is to create idealized models that recreate the morphology of the tissue. This paper presents a partial dev...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(93)90057-l
更新日期:1993-08-01 00:00:00
abstract::Several motion capture methods exist for predicting hip joint centers (HJC). These methods include regression models, functional joints, and projections from greater trochanters. While regression and functional methods have been compared to imaging techniques, the TROCH method has not been previously validated. The pu...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.06.013
更新日期:2016-09-06 00:00:00
abstract::Previous studies of compensatory stepping, in response to postural perturbation, have focussed on forward or backward stepping; however, the ability to step in other directions is of equal functional importance, since the perturbations encountered in daily life may often include a lateral component. The primary object...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(95)00053-4
更新日期:1996-03-01 00:00:00
abstract::The spring-loaded inverted pendulum (SLIP) model is a well established model for describing bouncy gaits like human running. The notion of spring-like leg behavior has led many researchers to compute the corresponding parameters, predominantly stiffness, in various experimental setups and in various ways. However, dif...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2012.06.030
更新日期:2012-09-21 00:00:00
abstract::Nanoindentation has been widely used as a means to measure the micro-mechanical properties of bone and to predict the macroscopic properties. The role of indent depth and indenter tip geometry in measuring the hierarchical properties of bone tissue was explored experimentally using a range of spherical indenter tips o...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.10.008
更新日期:2011-01-11 00:00:00
abstract::Walking appears to be passively unstable in the lateral direction, requiring active feedback control for stability. The central nervous system may control stability by adjusting medio-lateral foot placement, but potentially with a metabolic cost. This cost increases with narrow steps and may affect the preferred step ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2003.06.002
更新日期:2004-06-01 00:00:00
abstract:OBJECTIVES:To assess the ability of a biomechanical impact model to predict the likelihood of distal radius fracture in children using data gathered for a previous epidemiological case-control study of falls from playground equipment. METHODOLOGY:Factor of Risk (FR) values were generated for each of selected subjects ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.11.028
更新日期:2006-01-01 00:00:00
abstract::Exergames provide a challenging opportunity for home-based training and evaluation of postural control in the elderly population, but affordable sensor technology and algorithms for assessment of whole body movement patterns in the home environment are yet to be developed. The aim of the present study was to evaluate ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.07.017
更新日期:2014-09-22 00:00:00
abstract::The mechanism of vertebral wedge fractures remains unclear and may relate to typical variations in the mechanical behavior of the intervertebral disc. To gain insight, we tested 16 individual whole discs (between levels T8 and L5) from nine cadavers (mean±SD: 66±16 years), loaded in compression at different rates (0.0...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.02.045
更新日期:2016-05-03 00:00:00
abstract::Adhesions of monocytes and platelets to a vascular surface, particularly in regions of flow stagnation, recirculation, and reattachment, are a significant initial event in a broad spectrum of particle-wall interactions that significantly influence the formation of stenotic lesions and mural thrombi. A number of approx...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(02)00434-7
更新日期:2003-03-01 00:00:00
abstract::Knowledge about in vivo spinal loads is required for the identification of risk factors for low back pain and for realistic preclinical testing of spinal implants. Therefore, the aim of the present study was to measure the in vivo forces on a vertebral body replacement (VBR) during trunk flexion and to analyze in deta...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.01.007
更新日期:2015-02-26 00:00:00
abstract:OBJECTIVE:To test the force plate as a gait analysis system for broilers and to determine how the ground reaction force (GRF) patterns change in these birds with growth and administration of analgesia. MATERIALS AND METHODS:Thirty-three male Ross 308 chicks were raised on either an ad libitum or restricted-feeding reg...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2006.09.014
更新日期:2007-01-01 00:00:00
abstract::Bone represents a porous tissue containing a fluid phase, a solid matrix, and cells. Movement of the fluid phase within the pores or spaces of the solid matrix translates endogenous and exogenous mechanobiological, biochemical and electromechanical signals from the system that is exposed to the dynamic external enviro...
journal_title:Journal of biomechanics
pub_type: 杂志文章,评审
doi:10.1016/s0021-9290(03)00123-4
更新日期:2003-10-01 00:00:00
abstract::Postural impairment due to neuro-degenerative disorders such as Parkinson's Disease (PD) leads to restricted gait patterns, fall-related injuries, decreased mobility, and loss of functional independence. Though several clinical and posturographic studies have attempted to reveal the complex pathophysiology involved in...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109791
更新日期:2020-05-22 00:00:00
abstract::Distal biceps tendon ruptures have been reported to be associated with narrowing of the proximal radioulnar space. There have been no studies that three-dimensionally measured the distance between the bicipital tuberosity and the proximal ulna during active motion. The purpose of this study was to three-dimensionally ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.110120
更新日期:2020-12-02 00:00:00
abstract::The in situ longitudinal strain of canine and porcine aortas was investigated. Marks of black water-resistant ink were placed on the aortas and the axial lengths between the marks were measured in situ and in vitro. When the aortas were cut, the retraction was measured and described by the stretch ratio, which is defi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(94)00091-h
更新日期:1995-05-01 00:00:00
abstract::Locations, magnitudes, and directions of pelvic muscle and acetabular contact forces are important to model the effects of abnormal conditions (e.g., deformity, surgery) of the hip accurately. Such data have not been reported previously. We computed the three-dimensional locations of all pelvic muscle and acetabular c...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(97)00041-9
更新日期:1997-09-01 00:00:00
abstract::One of the main determinants of perfusion distribution within an organ is the structure of its vascular network. Past studies were based on angiography or corrosion casting and lacked quantitative three dimensional, 3D, representation. Based on branching rules and other properties derived from such imaging, 3D vascula...
journal_title:Journal of biomechanics
pub_type: 杂志文章,评审
doi:10.1016/j.jbiomech.2012.11.027
更新日期:2013-01-18 00:00:00
abstract::The purpose of this work was to establish a controlled and reversible muscle weakness model for studying the effects of weakness on joint degeneration leading to osteoarthritis (OA). The knee extensor muscles of rabbits were injected with single or repeat doses of Botulinum type-A toxin (BTX-A) to partially inhibit ac...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.03.001
更新日期:2007-01-01 00:00:00
abstract::Many soft biological tissues possess a considerable surface stress, which plays a significant role in their biophysical functions, but most previous methods for characterizing their mechanical properties have neglected the effects of surface stress. In this work, we investigate the micropipette aspiration method to me...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.08.020
更新日期:2018-10-26 00:00:00
abstract::Left ventricular (LV) chamber flow is undoubtedly influenced by the time-dependent regional motion of the LV wall. In an attempt to obtain diagnostic parameters based on LV chamber flow, we computed the LV chamber, two-dimensional systolic velocity and pressure distribution for two right anterior oblique (RAO) ventric...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(94)90201-1
更新日期:1994-02-01 00:00:00
abstract::Bone is subjected in vivo to both high amplitude, low frequency strain, incurred by locomotion, and to low amplitude, broad frequency strain. The biological effects of low amplitude, broad frequency strain are poorly understood. To evaluate the effects of low amplitude strains ranging in frequency from 0 to 50 Hz on o...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(02)00245-2
更新日期:2003-01-01 00:00:00
abstract::Skeletal muscle is a very dynamic tissue, thus accurate quantification of skeletal muscle stiffness throughout its functional range is crucial to improve the physical functioning and independence following pathology. Shear wave elastography (SWE) is an ultrasound-based technique that characterizes tissue mechanical pr...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.07.033
更新日期:2013-09-27 00:00:00
abstract:INTRODUCTION:The postnatal heart grows mostly in response to increased hemodynamic load. However, the specific biomechanical stimuli that stimulate cardiac growth as a reaction to increased hemodynamic load are still poorly understood. It has been shown that isolated neonatal rat cardiac myocytes normalize resting sarc...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.11.028
更新日期:2012-03-15 00:00:00
abstract::Fibroblasts in intact tendons align with stretching direction, but they tend to orient randomly in healing tendons. Therefore, a question arises: Do fibroblast responses to mechanical stretching depend on their orientation? To address this question, human patellar tendon fibroblasts were grown in custom-made silicone ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2003.09.011
更新日期:2004-04-01 00:00:00