Using regression models to determine the poroelastic properties of cartilage.

Abstract:

:The feasibility of determining biphasic material properties using regression models was investigated. A transversely isotropic poroelastic finite element model of stress relaxation was developed and validated against known results. This model was then used to simulate load intensity for a wide range of material properties. Linear regression equations for load intensity as a function of the five independent material properties were then developed for nine time points (131, 205, 304, 390, 500, 619, 700, 800, and 1000s) during relaxation. These equations illustrate the effect of individual material property on the stress in the time history. The equations at the first four time points, as well as one at a later time (five equations) could be solved for the five unknown material properties given computed values of the load intensity. Results showed that four of the five material properties could be estimated from the regression equations to within 9% of the values used in simulation if time points up to 1000s are included in the set of equations. However, reasonable estimates of the out of plane Poisson's ratio could not be found. Although all regression equations depended on permeability, suggesting that true equilibrium was not realized at 1000s of simulation, it was possible to estimate material properties to within 10% of the expected values using equations that included data up to 800s. This suggests that credible estimates of most material properties can be obtained from tests that are not run to equilibrium, which is typically several thousand seconds.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Chung CY,Mansour JM

doi

10.1016/j.jbiomech.2013.05.028

subject

Has Abstract

pub_date

2013-07-26 00:00:00

pages

1921-7

issue

11

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(13)00261-3

journal_volume

46

pub_type

杂志文章
  • A volumetric model for growth of arterial walls with arbitrary geometry and loads.

    abstract::Stress and deformation in arterial wall tissue are factors which may influence significantly its response and evolution. In this work we develop models based on nonlinear elasticity and finite element numerical solutions for the mechanical behaviour and the remodelling of the soft tissue of arteries, including anisotr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.05.002

    authors: Rodríguez J,Goicolea JM,Gabaldón F

    更新日期:2007-01-01 00:00:00

  • Comparison of muscle forces and joint load from an optimization and EMG assisted lumbar spine model: towards development of a hybrid approach.

    abstract::The purpose of this study was to determine whether the same estimates of individual muscle and L4/L5 lumbar joint compressive forces result from an optimization (OPT) compared to an electromyography (EMG) assisted approach for solving the inderminate moment equilibrium equations in the same anatomical model. Four male...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)00065-c

    authors: Cholewicki J,McGill SM,Norman RW

    更新日期:1995-03-01 00:00:00

  • Sensitivity of a Hill-based muscle model to perturbations in model parameters.

    abstract::Musculoskeletal simulations of human movement commonly use Hill muscle models to predict muscle forces, but their sensitivity to model parameter values is not well understood. The purpose of this study was to evaluate muscle model sensitivity to perturbations in 14 Hill muscle model parameters in forward dynamic simul...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.06.005

    authors: Scovil CY,Ronsky JL

    更新日期:2006-01-01 00:00:00

  • Estimating severity of sideways fall using a generic multi linear regression model based on kinematic input variables.

    abstract::Many research groups have studied fall impact mechanics to understand how fall severity can be reduced to prevent hip fractures. Yet, direct impact force measurements with force plates are restricted to a very limited repertoire of experimental falls. The purpose of this study was to develop a generic model for estima...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.01.033

    authors: van der Zijden AM,Groen BE,Tanck E,Nienhuis B,Verdonschot N,Weerdesteyn V

    更新日期:2017-03-21 00:00:00

  • Effect of cracks on the local deformations of articular cartilage.

    abstract::Despite significant evidence regarding the increased risk of cartilage degeneration due to traumatic injuries to joints, there is still a lack of understanding of the mechanisms underlying osteoarthritis development following a joint injury. Injuries in knee cartilage are often characterized by lesions or tears. In ad...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109970

    authors: Komeili A,Luqman S,Federico S,Herzog W

    更新日期:2020-09-18 00:00:00

  • Development of biomechanical response corridors of the thorax to blunt ballistic impacts.

    abstract::Human responses are critical to understanding injury biomechanics in blunt ballistic impacts, which are defined as 20-200 g projectiles impacting at 20-250 m/s. 13 human cadavers were exposed to three distinct ballistic impacts of the chest to determine force-time, deflection-time and force-deflection responses. Compa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00238-0

    authors: Bir C,Viano D,King A

    更新日期:2004-01-01 00:00:00

  • Dynamic tensile properties of bovine periodontal ligament: A nonlinear viscoelastic model.

    abstract::As a support to the tooth, the mechanical response of the periodontal ligament (PDL) is complex. Like other connective tissues, the PDL exhibits non-linear and time-dependent behavior. The viscoelasticity of the PDL plays a significant role in low and high loading rates. Little information, however, is available on th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.02.020

    authors: Oskui IZ,Hashemi A

    更新日期:2016-03-21 00:00:00

  • What is the role of the convective current density in the real-time calcium response of cultured bone cells to fluid flow?

    abstract::Cultured cells subjected to fluid flow are exposed to mechanical forces and electrokinetic forces. The convective current establishes an electrokinetic force created by the flow-dependent transport of mobile ions in the media over the charged cell surfaces. This current can be expressed as a current density, the curre...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)84535-0

    authors: Hung CT,Allen FD,Pollack SR,Brighton CT

    更新日期:1996-11-01 00:00:00

  • Sagittal plane rotation center of lower lumbar spine during a dynamic weight-lifting activity.

    abstract::This study investigated the center of rotation (COR) of the intervertebral segments of the lower lumbar spine (L4-L5 and L5-S1 segments) in sagittal plane during a weight-lifting (3.6 kg in each hand) extension activity performed with the pelvis constrained. Seven healthy subjects were studied using a dual fluoroscopi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.12.029

    authors: Liu Z,Tsai TY,Wang S,Wu M,Zhong W,Li JS,Cha T,Wood K,Li G

    更新日期:2016-02-08 00:00:00

  • Squeeze-film lubrication of the human ankle joint with synovial fluid filtrated by articular cartilage with the superficial zone worn out.

    abstract::A squeeze-film lubrication model of the human ankle joint in standing that takes into account the fluid transport across the articular surface is presented. Articular cartilage is a biphasic mixture of the ideal interstitial fluid and an elastic permeable isotropic homogeneous intrinsically incompressible matrix. The ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00109-3

    authors: Hlavácek M

    更新日期:2000-11-01 00:00:00

  • NLT and extrapolated DLT:3-D cinematography alternatives for enlarging the volume of calibration.

    abstract::This study investigated the accuracy of the direct linear transformation (DLT) and non-linear transformation (NLT) methods of 3-D cinematography/videography. A comparison of standard DLT, extrapolated DLT, and NLT calibrations showed the standard (non-extrapolated) DLT to be the most accurate, especially when a large ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00034-f

    authors: Hinrichs RN,McLean SP

    更新日期:1995-10-01 00:00:00

  • Morphologic adaptation of arterial endothelial cells to longitudinal stretch in organ culture.

    abstract::Arteries in vivo are subjected to large longitudinal stretch, which changes significantly due to vascular disease and surgery. However, little is known about the effect of longitudinal stretch on arterial endothelium. The aim of this study was to determine the morphologic adaptation of arterial endothelial cells (ECs)...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.08.016

    authors: Lee YU,Drury-Stewart D,Vito RP,Han HC

    更新日期:2008-11-14 00:00:00

  • A method for automated control of belt velocity changes with an instrumented treadmill.

    abstract::Increased practice difficulty during asymmetrical split-belt treadmill rehabilitation has been shown to improve gait outcomes during retention and transfer tests. However, research in this area has been limited by manual treadmill operation. In the case of variable practice, which requires stride-by-stride changes to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.11.017

    authors: Hinkel-Lipsker JW,Hahn ME

    更新日期:2016-01-04 00:00:00

  • Reliability of medial-longitudinal-arch measures for skin-markers based kinematic analysis.

    abstract::The medial-longitudinal arch (MLA) is perhaps the most important feature characterizing foot morphology. While current skin-markers based models of the MLA angle used in stereophotogrammetry allow to estimate foot arch shape and deformation, these do not always appear consistent with foot anatomy and with standard cli...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.03.017

    authors: Caravaggi P,Matias AB,Taddei UT,Ortolani M,Leardini A,Sacco ICN

    更新日期:2019-05-09 00:00:00

  • A linearized formulation of triphasic mixture theory for articular cartilage, and its application to indentation analysis.

    abstract::The negative charges on proteoglycans significantly affect the mechanical behaviors of articular cartilage. Mixture theories, such as the triphasic theory, can describe quantitatively how this charged nature contributes to the mechano-electrochemical behaviors of such tissue. However, the mathematical complexity of th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.026

    authors: Lu XL,Wan LQ,Guo XE,Mow VC

    更新日期:2010-03-03 00:00:00

  • Does screw-bone interface modelling matter in finite element analyses?

    abstract::The effect of screw-bone interface modelling strategies was evaluated in the setting of a tibial mid-shaft fracture stabilised using locking plates. Three interface models were examined: fully bonded interface; screw with sliding contact with bone; and screw with sliding contact with bone in an undersized pilot hole. ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.04.008

    authors: MacLeod AR,Pankaj P,Simpson AH

    更新日期:2012-06-01 00:00:00

  • Theoretical effects of fully ductile versus fully brittle behaviors of bone tissue on the strength of the human proximal femur and vertebral body.

    abstract::The influence of the ductility of bone tissue on whole-bone strength represents a fundamental issue of multi-scale biomechanics. To gain insight, we performed a computational study of 16 human proximal femurs and 12 T9 vertebral bodies, comparing the whole-bone strength for the two hypothetical bounding cases of fully...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.066

    authors: Nawathe S,Yang H,Fields AJ,Bouxsein ML,Keaveny TM

    更新日期:2015-05-01 00:00:00

  • Experimental validation of a time-domain-based wave propagation model of blood flow in viscoelastic vessels.

    abstract::Time-domain-based one-dimensional wave propagation models of the arterial system are preferable over one-dimensional wave propagation models in the frequency domain since the latter neglect the non-linear convection forces present in the physiological situation, especially when the vessel is tapered. Moreover, one-dim...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.09.014

    authors: Bessems D,Giannopapa CG,Rutten MC,van de Vosse FN

    更新日期:2008-01-01 00:00:00

  • Effect of boundary conditions, impact loading and hydraulic stiffening on femoral fracture strength.

    abstract::Patient specific quantitative CT (QCT) imaging data together with the finite element (FE) method may provide an accurate prediction of a patient's femoral strength and fracture risk. Although numerous FE models investigating femoral fracture strength have been published, there is little consent on the effect of bounda...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.07.004

    authors: Haider IT,Speirs AD,Frei H

    更新日期:2013-09-03 00:00:00

  • Age-related distensibility and histology of the ascending aorta in elderly patients with acute aortic dissection.

    abstract::Degradation and fragmentation of elastic fibers in the media dilate the aortic wall excessively in patients with acute Stanford type A aortic dissection (AD). Such dilatation occurs not via aortic stiffening, which is diagnosed using imaging under physiological loading, but due to the abovementioned intrinsic changes ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.06.025

    authors: Yamada H,Sakata N,Wada H,Tashiro T,Tayama E

    更新日期:2015-09-18 00:00:00

  • Dynamic mechanical response of bovine gray matter and white matter brain tissues under compression.

    abstract::Dynamic responses of brain tissues are needed for predicting traumatic brain injury (TBI). We modified a dynamic experimental technique for characterizing high strain-rate mechanical behavior of brain tissues. Using the setup, the gray and white matters from bovine brains were characterized under compression to large ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.01.023

    authors: Pervin F,Chen WW

    更新日期:2009-04-16 00:00:00

  • Compression-induced damage and internal tissue strains are related.

    abstract::Prolonged mechanical loading of soft tissues adjacent to bony prominences can lead to degeneration of muscle tissue, resulting in a condition termed pressure-related deep tissue injury. This type of deep pressure ulcers can develop into a severe wound, associated with problematic healing and a variable prognosis. Limi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.09.016

    authors: Ceelen KK,Stekelenburg A,Loerakker S,Strijkers GJ,Bader DL,Nicolay K,Baaijens FP,Oomens CW

    更新日期:2008-12-05 00:00:00

  • Mechanical properties of human atherosclerotic intima tissue.

    abstract::Progression and rupture of atherosclerotic plaques in coronary and carotid arteries are the key processes underlying myocardial infarctions and strokes. Biomechanical stress analyses to compute mechanical stresses in a plaque can potentially be used to assess plaque vulnerability. The stress analyses strongly rely on ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2014.01.019

    authors: Akyildiz AC,Speelman L,Gijsen FJ

    更新日期:2014-03-03 00:00:00

  • Regional dependency of the vascular smooth muscle cell contribution to the mechanical properties of the pig ascending aortic tissue.

    abstract:BACKGROUND:Dilation and dissection of aneurysmal ascending aortic tissues occur preferentially at the outer curvature of the vessel. In this study we hypothesize that the density and contractile properties of the vascular smooth muscle cells (VSMCs) of the pig ascending aorta (AA) are heterogeneous and could explain th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.04.018

    authors: Tremblay D,Cartier R,Mongrain R,Leask RL

    更新日期:2010-08-26 00:00:00

  • Gait in rheumatoid arthritis: an electrogoniometric investigation.

    abstract::For the purpose of detecting early aberrations of gait in rheumatoid arthritis 17 women suffering from that disease were examined. They were all under 50 years of age and had an essentially normal range of motility in the hips, knees and ankles. Eleven healthy women walking at voluntary speed and 6 healthy women walki...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90237-0

    authors: Isacson J,Broström LA

    更新日期:1988-01-01 00:00:00

  • Automatic selection of a representative trial from multiple measurements using Principle Component Analysis.

    abstract::Experimental data in human movement science commonly consist of repeated measurements under comparable conditions. One can face the question how to identify a single trial, a set of trials, or erroneous trials from the entire data set. This study presents and evaluates a Selection Method for a Representative Trial (SM...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.06.012

    authors: Schweizer K,Cattin PC,Brunner R,Müller B,Huber C,Romkes J

    更新日期:2012-08-31 00:00:00

  • Biomedical microfluidic devices by using low-cost fabrication techniques: A review.

    abstract::One of the most popular methods to fabricate biomedical microfluidic devices is by using a soft-lithography technique. However, the fabrication of the moulds to produce microfluidic devices, such as SU-8 moulds, usually requires a cleanroom environment that can be quite costly. Therefore, many efforts have been made t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2015.11.031

    authors: Faustino V,Catarino SO,Lima R,Minas G

    更新日期:2016-07-26 00:00:00

  • An effortless procedure to align the local frame of an inertial measurement unit to the local frame of another motion capture system.

    abstract::Inertial measurement units (IMUs) offer great opportunities to analyze segmental and joints kinematics. When combined with another motion capture system (MCS), for example, to validate new IMU-based applications or to develop mixed systems, it is necessary to align the local frame of the IMU sensors to the local frame...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.06.009

    authors: Chardonnens J,Favre J,Aminian K

    更新日期:2012-08-31 00:00:00

  • Upper limb joint kinetics during manual wheelchair propulsion in patients with different levels of spinal cord injury.

    abstract::The purpose of this study was to compare the forces and moments of the whole upper limb, analyzing forces and moments at the shoulder, elbow and wrist joints simultaneously during manual wheelchair propulsion of persons with different levels of spinal cord injury (SCI) on a treadmill. Fifty-one people participated in ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.05.021

    authors: Gil-Agudo A,Del Ama-Espinosa A,Pérez-Rizo E,Pérez-Nombela S,Pablo Rodríguez-Rodríguez L

    更新日期:2010-09-17 00:00:00

  • Bone strain sensation via transmembrane potential changes in surface osteoblasts: loading rate and microstructural implications.

    abstract::A model is developed in which osteoblasts can sense the strains applied to a small region of bone through electrical coupling between adjacent cells. The stress-generated potentials within bone are assumed to occur through streaming potentials, and the coupled network of osteocytes is assumed to act in a manner simila...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90048-j

    authors: Harrigan TP,Hamilton JJ

    更新日期:1993-02-01 00:00:00