Morphologic adaptation of arterial endothelial cells to longitudinal stretch in organ culture.

Abstract:

:Arteries in vivo are subjected to large longitudinal stretch, which changes significantly due to vascular disease and surgery. However, little is known about the effect of longitudinal stretch on arterial endothelium. The aim of this study was to determine the morphologic adaptation of arterial endothelial cells (ECs) to elevated axial stretch. Porcine carotid arteries were stretched 20% more than their in vivo length while being maintained at physiological pressure and flow rate in an organ culture system. The ECs were elongated with the application of the axial stretch (aspect ratio 2.81+/-0.25 versus 3.65+/-0.38, n=8, p<0.001). The elongation was slightly decreased after three days and the ECs recovered their normal shape after seven days, as measured by the shape index and aspect ratio (0.55+/-0.03 versus 0.56+/-0.04, and 2.93+/-0.28 versus 2.88+/-0.20, respectively, n=5). Cell proliferation was increased in the intima of stretched arteries in three days as compared to control arteries but showed no difference after seven days in organ culture. These results demonstrate that the ECs adapt to axial stretch and maintain their normal shape.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Lee YU,Drury-Stewart D,Vito RP,Han HC

doi

10.1016/j.jbiomech.2008.08.016

subject

Has Abstract

pub_date

2008-11-14 00:00:00

pages

3274-7

issue

15

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(08)00438-7

journal_volume

41

pub_type

杂志文章
  • Formation and travel of vortices in model ventricles: application to the design of skeletal muscle ventricles.

    abstract::Vortex-ring production was studied in axisymmetric elastomeric ventricles designed to stimulate flow in a cardiovascular assist device. A flow visualization technique was used to investigate the effects of reducing the inlet diameter and predilating the ventricle on vortex travel in two ventricles of different shape a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00065-8

    authors: Shortland AP,Black RA,Jarvis JC,Henry FS,Iudicello F,Collins MW,Salmons S

    更新日期:1996-04-01 00:00:00

  • A dynamic model of the forearm including fatigue.

    abstract::A biomechanical model of the forearm, consisting of 61 muscle-tendon systems or tendons and 8 sections, is presented. The model can be used to calculate the muscle forces when resultant of the external forces and the motion is known. Calculations are based on constraints of muscle forces, joint forces, contact forces,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00009-4

    authors: Freund J,Takala EP

    更新日期:2001-05-01 00:00:00

  • An equation to calculate individual muscle contributions to joint stability.

    abstract::The purpose of the current paper was to use the energy approach to develop a simplified equation for quantifying individual muscle contributions to mechanical stability about all three axes of a particular joint. Specific examples are provided for muscles acting about the lumbar spine's L4/L5 joint. The stability equa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.06.004

    authors: Potvin JR,Brown SH

    更新日期:2005-05-01 00:00:00

  • 3D kinematic and dynamic analysis of the front crawl tumble turn in elite male swimmers.

    abstract::The aim of this study was to identify kinematic and dynamic variables related to the best tumble turn times (3mRTT, the turn time from 3-m in to 3-m out, independent variable) in ten elite male swimmers using a three-dimensional (3D) underwater analysis protocol and the Lasso (least absolute shrinkage and selection op...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.11.043

    authors: Puel F,Morlier J,Avalos M,Mesnard M,Cid M,Hellard P

    更新日期:2012-02-02 00:00:00

  • Hydro-resistive measurement of dynamic lifting strength.

    abstract::A device is described for measuring strength and power outputs of dynamic vertical lifts between heights of 0.4 and 2.2 m. The device is safe, robust, and easily transportable. It consists of a water-filled tube 2 m high and 200 mm internal diameter. The subject pulls vertically on a handle which is connected with fle...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(96)00155-8

    authors: Pinder AD,Grieve DW

    更新日期:1997-04-01 00:00:00

  • A mechanical apparatus with microprocessor controlled stress profile for cyclic compression of cultured articular cartilage explants.

    abstract::An apparatus was designed for mechanical compression of cultured articular cartilage explants with acylindrical plain-ended loading head (diameter 2-5 mm) driven by a stepping motor. A load cell under the culture dish was applied for feedback regulation utilizing a microprocessor-based control unit. The operating prog...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90232-7

    authors: Parkkinen JJ,Lammi MJ,Karjalainen S,Laakkonen J,Hyvärinen E,Tiihonen A,Helminen HJ,Tammi M

    更新日期:1989-01-01 00:00:00

  • Analysis of the musculoskeletal loading of the thumb during pipetting--a pilot study.

    abstract::Previous epidemiological studies indicate that the use of thumb-push mechanical pipettes is associated with musculoskeletal disorders (MSDs) in the hand. The goal of the current study was to analyze the loading in the muscle-tendon units in the thumb during pipetting. The hand is modeled as a multi-body linkage system...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.11.015

    authors: Wu JZ,Sinsel EW,Shroyer JF,Warren CM,Welcome DE,Zhao KD,An KN,Buczek FL

    更新日期:2014-01-22 00:00:00

  • Assessment of compressive modulus, hydraulic permeability and matrix content of trypsin-treated nucleus pulposus using quantitative MRI.

    abstract::A clinical strength MRI and intact bovine caudal intervertebral discs were used to test the hypotheses that (1) mechanical loading and trypsin treatment induce changes in NMR parameters, mechanical properties and biochemical contents; and (2) mechanical properties are quantitatively related to NMR parameters. MRI acqu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.04.015

    authors: Périé D,Iatridis JC,Demers CN,Goswami T,Beaudoin G,Mwale F,Antoniou J

    更新日期:2006-01-01 00:00:00

  • Phalanx force magnitude and trajectory deviation increased during power grip with an increased coefficient of friction at the hand-object interface.

    abstract::This study examined the effect of friction between the hand and grip surface on a person's grip strategy and force generation capacity. Twelve young healthy adults performed power grip exertions on an instrumented vertical cylinder with the maximum and 50% of maximum efforts (far above the grip force required to hold ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.03.020

    authors: Enders LR,Seo NJ

    更新日期:2011-05-17 00:00:00

  • Cellular mechanobiology of the intervertebral disc: new directions and approaches.

    abstract::The more we learn about the intervertebral disc (IVD), the more we come to appreciate the intricacies involved in transmission of forces through the ECM to the cell, and in the biological determinants of its response to mechanical stress. This review highlights recent developments in our knowledge of IVD physiology an...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2009.09.019

    authors: Hsieh AH,Twomey JD

    更新日期:2010-01-05 00:00:00

  • A mechanical approach to the longitudinal dispersion of gas flowing in human airways.

    abstract::The aim of this work is to contribute to elucidating the mechanism underlying gas mixing in the human pulmonary airways. For this purpose, a particular attempt is made to analyse the fluid mechanical aspects of gaseous dispersion using bolus response methods. The experiments were performed on five normal subjects by i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(85)90295-7

    authors: Ben Jebria A

    更新日期:1985-01-01 00:00:00

  • In vivo human knee joint dynamic properties as functions of muscle contraction and joint position.

    abstract::Information on the dynamic properties (joint stiffness, viscosity and limb inertia) of the human knee joint is scarce in the literature, especially for actively contracting knee musculature. A joint driving device was developed to apply small-amplitude random perturbations to the human knee at several flexion angles w...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00106-1

    authors: Zhang LQ,Nuber G,Butler J,Bowen M,Rymer WZ

    更新日期:1998-01-01 00:00:00

  • Knee joint biomechanics of patients with unilateral total knee arthroplasty during stationary cycling.

    abstract::Stationary cycling is typically recommended following total knee arthroplasty (TKA) operations. However, knee joint biomechanics during cycling remains mostly unknown for TKA patients. Biomechanical differences between the replaced and non-replaced limb may inform applications of cycling in TKA rehabilitation. The pur...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110111

    authors: Hummer E,Thorsen T,Weinhandl JT,Cates H,Zhang S

    更新日期:2021-01-22 00:00:00

  • Biomechanical comparison of the human cadaveric pelvis with a fourth generation composite model.

    abstract::The use of cadavers for orthopaedic biomechanics research is well established, but presents difficulties to researchers in terms of cost, biosafety, availability, and ease of use. High fidelity composite models of human bone have been developed for use in biomechanical studies. While several studies have utilized comp...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.12.050

    authors: Girardi BL,Attia T,Backstein D,Safir O,Willett TL,Kuzyk PR

    更新日期:2016-02-29 00:00:00

  • Compliance calibration for fracture testing of equine cortical bone.

    abstract::An experimental compliance calibration method for measuring crack length in fracture toughness tests of cortical bone was developed. Calibration tests were conducted on twenty compact type fracture specimens machined from the mid-diaphysis of five pairs of equine third metacarpal bones. Specimens were oriented for cra...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00009-x

    authors: Malik CL,Gibeling JC,Martin RB,Stover SM

    更新日期:2002-05-01 00:00:00

  • Altered frontal and transverse plane tibiofemoral kinematics and patellofemoral malalignments during downhill gait in patients with mixed knee osteoarthritis.

    abstract::Patients with knee osteoarthritis often present with signs of mixed tibiofemoral and patellofemoral joint disease. It has been suggested that altered frontal and transverse plane knee joint mechanics play a key role in compartment-specific patterns of knee osteoarthritis, but in-vivo evidence in support of this premis...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.05.015

    authors: Farrokhi S,Meholic B,Chuang WN,Gustafson JA,Fitzgerald GK,Tashman S

    更新日期:2015-07-16 00:00:00

  • In situ AFM-based nanoscale rheology reveals regional non-uniformity in viscoporoelastic mechanical behavior of the murine periodontal ligament.

    abstract::The periodontal ligament (PDL) is a critical player in the maintenance of tooth health, acting as the primary stabilizer of tooth position. Recent studies have identified two unique regions within the PDL, the 'dense collar' region and the 'furcation' region, which exhibit distinct structural and compositional differe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109996

    authors: Connizzo BK,Naveh GRS

    更新日期:2020-10-09 00:00:00

  • Patterns in the knee flexion-extension moment profile during stair ascent and descent in patients with total knee arthroplasty.

    abstract::The aim of this study was to investigate the prevalence of abnormal knee biomechanical patterns in 40 patients with a modern TKA prosthesis, compared to 40 matched control participants when ascending and descending stairs. Fewer patients were able to ascend (65%) or descend stairs (53%) unassisted than controls (83%)....

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.03.026

    authors: McClelland JA,Feller JA,Menz HB,Webster KE

    更新日期:2014-06-03 00:00:00

  • Micropipette aspiration method for characterizing biological materials with surface energy.

    abstract::Many soft biological tissues possess a considerable surface stress, which plays a significant role in their biophysical functions, but most previous methods for characterizing their mechanical properties have neglected the effects of surface stress. In this work, we investigate the micropipette aspiration method to me...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.08.020

    authors: Ding Y,Wang GF,Feng XQ,Yu SW

    更新日期:2018-10-26 00:00:00

  • Finite element investigation of the loading rate effect on the spinal load-sharing changes under impact conditions.

    abstract::Sudden deceleration and frontal/rear impact configurations involve rapid movements that can cause spinal injuries. This study aimed to investigate the rotation rate effect on the L2-L3 motion segment load-sharing and to identify which spinal structure is at risk of failure and at what rotation velocity the failure may...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.036

    authors: El-Rich M,Arnoux PJ,Wagnac E,Brunet C,Aubin CE

    更新日期:2009-06-19 00:00:00

  • Compression data on bovine bone confirms that a "stressed volume" principle explains the variability of fatigue strength results.

    abstract::The literature contains many measurements of the fatigue properties of compact bone, but these experimental results have been difficult to interpret and use due to a large amount of apparent scatter: variation in the number of cycles to failure for a given cyclic stress or strain range. Recently Taylor (1998a, Journal...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00112-8

    authors: Taylor D,O'Brien F,Prina-Mello A,Ryan C,O'Reilly P,Lee TC

    更新日期:1999-11-01 00:00:00

  • Motion of the residual femur within the socket during gait is associated with patient-reported problems in transfemoral amputees.

    abstract::The purpose of this study was to provide a quantitative description of residual femur motion within the socket during gait and to explore the relationship between residual femur motion and patient-reported comfort and function. It was hypothesized that increased residual bone movement would correlate to worse patient-...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110050

    authors: Gale T,Yang S,McGough R,Fiedler G,Anderst W

    更新日期:2020-11-09 00:00:00

  • Deficiency of macrophage migration inhibitory factor gene delays healing of the medial collateral ligament: a biomechanical and biological study.

    abstract::The role played by macrophage migration inhibitory factor (MIF) in the process of wound healing is controversial. Besides, there have been no reports that investigated the expression or the role of MIF in the repair process after ligament injury. In this study, we hypothesized that the deficiency in MIF gene might del...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.09.018

    authors: Kitayama S,Onodera S,Kondo E,Kobayashi T,Miyatake S,Kitamura N,Tohyama H,Yasuda K

    更新日期:2011-02-03 00:00:00

  • Blood flow patterns and pressure loss in the ascending aorta: A comparative study on physiological and aneurysmal conditions.

    abstract::An aortic aneurysm is defined as a balloon-shaped bulging of all three histologic components of the aortic vessel walls (intima, media and adventitia). This dilation results from vessel weakening owing to remodeling, i.e. due to cystic degeneration of the Tunica media (Marfan), progression of atherosclerosis or presen...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.05.033

    authors: Gülan U,Calen C,Duru F,Holzner M

    更新日期:2018-07-25 00:00:00

  • Blood flow patterns in an anatomically realistic coronary vessel: influence of three different reconstruction methods.

    abstract::Many clinical studies suggest that local blood flow patterns are involved in the location and development of atherosclerosis. In coronary diseases, this assumption should be corroborated by quantitative information on local hemodynamic parameters such as pressure, velocity or wall shear stress. Nowadays, computational...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00179-3

    authors: Berthier B,Bouzerar R,Legallais C

    更新日期:2002-10-01 00:00:00

  • Non-linear viscoelastic models predict fingertip pulp force-displacement characteristics during voluntary tapping.

    abstract::We evaluated whether lumped-parameter non-linear viscoelastic models of human fingertip tissue can describe fingertip force-displacement characteristics during a range of rapid, dynamic tapping tasks. Eight human subjects tapped with their index finger on the surface of a rigid load cell while an optical system tracke...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/s0021-9290(02)00438-4

    authors: Jindrich DL,Zhou Y,Becker T,Dennerlein JT

    更新日期:2003-04-01 00:00:00

  • Explaining Parkinsonian postural sway variabilities using intermittent control theory.

    abstract::Postural impairment due to neuro-degenerative disorders such as Parkinson's Disease (PD) leads to restricted gait patterns, fall-related injuries, decreased mobility, and loss of functional independence. Though several clinical and posturographic studies have attempted to reveal the complex pathophysiology involved in...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109791

    authors: Dash R,Shah VV,Palanthandalam-Madapusi HJ

    更新日期:2020-05-22 00:00:00

  • Passive muscle mechanical properties of the medial gastrocnemius in young adults with spastic cerebral palsy.

    abstract::Individuals with spastic cerebral palsy (SCP) exhibit restricted joint range of motion and increased joint stiffness due to structural alterations of their muscles. Little is known about which muscle-tendon structures are responsible for these alterations. The aim of this study was to compare the passive mechanics of ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.06.008

    authors: Barber L,Barrett R,Lichtwark G

    更新日期:2011-09-02 00:00:00

  • Characterization of three dimensional volumetric strain distribution during passive tension of the human tibialis anterior using Cine Phase Contrast MRI.

    abstract::Intramuscular pressure correlates strongly with muscle tension and is a promising tool for quantifying individual muscle force. However, clinical application is impeded by measurement variability that is not fully understood. Previous studies point to regional differences in IMP, specifically increasing pressure with ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.09.002

    authors: Jensen ER,Morrow DA,Felmlee JP,Murthy NS,Kaufman KR

    更新日期:2016-10-03 00:00:00

  • Numerical simulation of steady flow fields in a model of abdominal aorta with its peripheral branches.

    abstract::In the present study, a numerical calculation procedure based on a finite volume method was developed to simulate steady flow fields in a model of abdominal aorta with its peripheral branches. The study focused on the steady baseline flow fields and the wall shear stress (WSS) distribution as well as the localization ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00044-1

    authors: Lee D,Chen JY

    更新日期:2002-08-01 00:00:00