Analysis of the musculoskeletal loading of the thumb during pipetting--a pilot study.

Abstract:

:Previous epidemiological studies indicate that the use of thumb-push mechanical pipettes is associated with musculoskeletal disorders (MSDs) in the hand. The goal of the current study was to analyze the loading in the muscle-tendon units in the thumb during pipetting. The hand is modeled as a multi-body linkage system and includes four fingers (index, long, ring, and little finger), a thumb, and a palm segment. Since the current study is focused on the thumb, the model includes only nine muscles attached to the thumb via tendons. The time-histories of joint angles and push force at the pipette plunger during pipetting were determined experimentally and used as model input; whereas forces in the muscle-tendon units in the thumb were calculated via an inverse dynamic approach combined with an optimization procedure. Results indicate that all nine muscles have force outputs during pipetting, and the maximal force was in the abductor pollicis brevis (APB). The ratio of the mean peak muscle force to the mean peak push force during the dispensing cycle was approximately 2.3, which is comparable to values observed in grasping tasks in the literature. The analysis method and results in the current study provide a mechanistic understanding of MSD risk factors associated with pipetting, and may be useful in guiding ergonomic designs for manual pipettes.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Wu JZ,Sinsel EW,Shroyer JF,Warren CM,Welcome DE,Zhao KD,An KN,Buczek FL

doi

10.1016/j.jbiomech.2013.11.015

subject

Has Abstract

pub_date

2014-01-22 00:00:00

pages

392-9

issue

2

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(13)00567-8

journal_volume

47

pub_type

杂志文章
  • Computational fluid dynamics for the assessment of upper airway response to oral appliance treatment in obstructive sleep apnea.

    abstract::Mandibular advancement splints (MAS), which protrude the lower jaw during sleep, are recognized as an effective treatment for obstructive sleep apnea (OSA) through their action of enlarging the airway space and preventing upper airway collapse. However a clinical challenge remains in preselecting patients who will res...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.10.033

    authors: Zhao M,Barber T,Cistulli P,Sutherland K,Rosengarten G

    更新日期:2013-01-04 00:00:00

  • Hamstring muscle-tendon unit lengthening and activation in instep and cut-off kicking.

    abstract::Hamstring muscle strain injury is one of the most common injuries in sports involving sprinting and kicking. Studies examining hamstring kinematics and activations are rich for sprinting but lacking for kicking. The purpose of this study was to examine kinematics and activations of hamstring muscles in instep and cut-...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109482

    authors: Zhang L,Li H,Garrett WE,Liu H,Yu B

    更新日期:2020-01-23 00:00:00

  • Tensile damage and its effects on cortical bone.

    abstract::Plexiform bovine bone samples are repeatedly loaded in tension along their longitudinal axis. In order to induce damage in the bone tissue, bone samples are loaded past their yield point. Half of the bone samples from the damaged group were stored in saline to allow for viscoelastic recovery while the others were deca...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00169-6

    authors: Kotha SP,Guzelsu N

    更新日期:2003-11-01 00:00:00

  • Multichannel strain gauge telemetry for orthopaedic implants.

    abstract::In vivo measurements of the loads and deformations occurring in orthopaedic implants will allow future improvements to be made. This paper describes an extremely small telemetry for long term measurements with three strain gauges and methods for an absolutely safe implant design. Developed for measuring the load at hi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90009-7

    authors: Bergmann G,Graichen F,Siraky J,Jendrzynski H,Rohlmann A

    更新日期:1988-01-01 00:00:00

  • Evaluation of residual stresses due to bone callus growth: a computational study.

    abstract::Mechanical environment in callus is determinant for the evolution of bone healing. However, recent mechanobiological computational works have underestimated the effect that growth exerts on the mechanical environment of callus. In the present work, we computationally evaluate the significance of growth-induced stresse...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.04.021

    authors: González-Torres LA,Gómez-Benito MJ,García-Aznar JM

    更新日期:2011-06-03 00:00:00

  • Effects of follower load and rib cage on intervertebral disc pressure and sagittal plane curvature in static tests of cadaveric thoracic spines.

    abstract::The clinical relevance of mechanical testing studies of cadaveric human thoracic spines could be enhanced by using follower preload techniques, by including the intact rib cage, and by measuring thoracic intervertebral disc pressures, but studies to date have not incorporated all of these components simultaneously. Th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.02.038

    authors: Anderson DE,Mannen EM,Sis HL,Wong BM,Cadel ES,Friis EA,Bouxsein ML

    更新日期:2016-05-03 00:00:00

  • Body weight support impacts lateral stability during treadmill walking.

    abstract::Body weight support (BWS) systems are a common tool used in gait rehabilitation. BWS systems may alter the requirements for an individual to actively stabilize by 1) providing lateral restoring forces that reduce the requirements for the nervous system to actively stabilize and 2) decreasing the stabilizing gravitatio...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.05.026

    authors: Dragunas AC,Gordon KE

    更新日期:2016-09-06 00:00:00

  • A kinematic and strain gauge study of the reciprocal apparatus in the equine hind limb.

    abstract::Hind limb kinematics were recorded in five horses at walk and trot using an opto-electronic CODA-3 system. Simultaneously, in vivo strain in the completely tendinous peroneus tertius muscle was registered by implanted mercury-in-silastic strain gauges. The origin-insertion length patterns of the peroneus tertius were ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90284-8

    authors: van Weeren PR,Jansen MO,van den Bogert AJ,Barneveld A

    更新日期:1992-11-01 00:00:00

  • Quantitative analysis of brain microstructure following mild blunt and blast trauma.

    abstract::We induced mild blunt and blast injuries in rats using a custom-built device and utilized in-house diffusion tensor imaging (DTI) software to reconstruct 3-D fiber tracts in brains before and after injury (1, 4, and 7 days). DTI measures such as fiber count, fiber length, and fractional anisotropy (FA) were selected t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.09.026

    authors: Begonia MT,Prabhu R,Liao J,Whittington WR,Claude A,Willeford B,Wardlaw J,Wu R,Zhang S,Williams LN

    更新日期:2014-11-28 00:00:00

  • Impact differences in ground reaction force and center of mass between the first and second landing phases of a drop vertical jump and their implications for injury risk assessment.

    abstract::The drop vertical jump (DVJ) task is commonly used to assess biomechanical performance measures that are associated with ACL injury risk in athletes. Previous investigations have solely assessed the first landing phase. We examined the first and second landings of a DVJ for differences in the magnitude of vertical gro...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2013.02.024

    authors: Bates NA,Ford KR,Myer GD,Hewett TE

    更新日期:2013-04-26 00:00:00

  • Twenty-fold difference in hemodynamic wall shear stress between murine and human aortas.

    abstract::Endothelial cells regulate vascular tone and mural remodelling in a shear-dependent manner that is commonly assumed to keep wall shear stress constant across arteries and species. Allometric arguments show that aortic flow velocity is constant across species, a deduction that is consistent with much experimental data,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.07.020

    authors: Weinberg PD,Ross Ethier C

    更新日期:2007-01-01 00:00:00

  • Stiffness versus prestress relationship at subcellular length scale.

    abstract::Local intracellular variations of cell mechanical properties, which are essential for vital cellular functions, have not been well characterized and are poorly understood. Here, we used results from our previous biomechanical imaging study to obtain relationships between intracellular shear modulus and prestress. We f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.08.004

    authors: Canović EP,Seidl DT,Barbone PE,Smith ML,Stamenović D

    更新日期:2014-09-22 00:00:00

  • Micromechanics modeling of Haversian cortical bone properties.

    abstract::A finite-element micromechanics model for Haversian cortical bone tissue has been developed and studied. The model is an extension of two-dimensional micromechanics techniques for fiber-reinforced composite materials. Haversian systems, or secondary osteons, are considered to be the fiber component, and interstitial l...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90095-i

    authors: Hogan HA

    更新日期:1992-05-01 00:00:00

  • Comparison of different state space definitions for local dynamic stability analyses.

    abstract::Measures of local dynamic stability, such as the local divergence exponent (lambda*(s)) quantify how quickly small perturbations deviate from an attractor that defines the motion. When the governing equations of motion are unknown, an attractor can be reconstructed by defining an appropriate state space. However, stat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.015

    authors: Gates DH,Dingwell JB

    更新日期:2009-06-19 00:00:00

  • A method for defining carpometacarpal joint kinematics from three-dimensional rotations of the metacarpal bones captured in vivo using computed tomography.

    abstract::The carpometacarpal (CMC) joints of the hand facilitate motion of the metacarpals and are critical for functional tasks, especially tasks involving precision grasping. Despite their importance, only limited data describing metacarpal kinematics exist. In this short communication, we quantified in vivo metacarpal kinem...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.05.019

    authors: Buffi JH,Crisco JJ,Murray WM

    更新日期:2013-08-09 00:00:00

  • The Cybermouse: a simple method of describing the trajectory of the human mandible in three dimensions.

    abstract::A simple method of recording the three-dimensional movements of the mandible together with up to 10 channels of other physiological data is described. The system is based on a commercially available device, the Cybermouse (IPC, Freemont, CA, U.S.A.), consisting of a lightweight ultrasonic emitter which can be attached...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00012-2

    authors: Prinz JF

    更新日期:1997-06-01 00:00:00

  • Sagittal range of motion of the thoracic spine using inertial tracking device and effect of measurement errors on model predictions.

    abstract::Range of motion (ROM) of the thoracic spine has implications in patient discrimination for diagnostic purposes and in biomechanical models for predictions of spinal loads. Few previous studies have reported quite different thoracic ROMs. Total (T1-T12), lower (T5-T12) and upper (T1-T5) thoracic, lumbar (T12-S1), pelvi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.09.003

    authors: Hajibozorgi M,Arjmand N

    更新日期:2016-04-11 00:00:00

  • Pure moment testing for spinal biomechanics applications: Fixed versus sliding ring cable-driven test designs.

    abstract::In vitro multi-axial bending testing using pure moment loading conditions has become the standard in evaluating the effects of different types of surgical intervention on spinal kinematics. Simple, cable-driven experimental set-ups have been widely adopted because they require little infrastructure. Traditionally, "fi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.02.004

    authors: Eguizabal J,Tufaga M,Scheer JK,Ames C,Lotz JC,Buckley JM

    更新日期:2010-05-07 00:00:00

  • Effect of simulated joint instability and bracing on ankle and subtalar joint flexibility.

    abstract::It is clinically challenging to distinguish between ankle and subtalar joints instability in vivo. Understanding the changes in load-displacement at the ankle and subtalar joints after ligament injuries may detect specific changes in joint characteristics that cannot be detected by investigating changes in range of mo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.10.033

    authors: Choisne J,McNally A,Hoch MC,Ringleb SI

    更新日期:2019-01-03 00:00:00

  • Modeling the mechanical properties of liver fibrosis in rats.

    abstract::The progression of liver fibrosis changes the biomechanical properties of liver tissue. This study characterized and compared different liver fibrosis stages in rats in terms of viscoelasticity. Three viscoelastic models, the Voigt, Maxwell, and Zener models, were applied to experimental data from rheometer tests and ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.013

    authors: Zhu Y,Chen X,Zhang X,Chen S,Shen Y,Song L

    更新日期:2016-06-14 00:00:00

  • Surface roughness parameters as predictors of anchorage strength in bone: a critical analysis.

    abstract::The surface roughness of a bone implant was defined parametrically. The values of the parameters defining the surface were varied. Some traditionally used surface roughness parameters were calculated. By means of a theoretical model the bone-implant interfacial shear strength was estimated. No simple correlation betwe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00045-2

    authors: Hansson S

    更新日期:2000-10-01 00:00:00

  • Alternative measures of toe trajectory more accurately predict the probability of tripping than minimum toe clearance.

    abstract::Tripping is responsible for a large percentage of falls. Minimum toe clearance (MTC) during the swing phase of gait is commonly used to infer the probability of tripping (POT). However, there is limited empirical evidence to support the relationship between these two variables, and other measures of toe trajectory may...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.10.045

    authors: Byju AG,Nussbaum MA,Madigan ML

    更新日期:2016-12-08 00:00:00

  • Patient-specific bone modelling and remodelling simulation of hypoparathyroidism based on human iliac crest biopsies.

    abstract::We previously developed a load-adaptive bone modelling and remodelling simulation model that can predict changes in the bone micro-architecture as a result of changes in mechanical loading or cell activity. In combination with a novel algorithm to estimate loading conditions, this offers the possibility for patient-sp...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.06.031

    authors: Christen P,Ito K,Müller R,Rubin MR,Dempster DW,Bilezikian JP,van Rietbergen B

    更新日期:2012-09-21 00:00:00

  • Expedited patient-specific assessment of contact stress exposure in the ankle joint following definitive articular fracture reduction.

    abstract::Acute injury severity, altered joint kinematics, and joint incongruity are three important mechanical factors linked to post-traumatic osteoarthritis (PTOA). Finite element analysis (FEA) was previously used to assess the influence of increased contact stress due to joint incongruity on PTOA development. While promisi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.05.030

    authors: Kern AM,Anderson DD

    更新日期:2015-09-18 00:00:00

  • The influences of foot placement on lumbopelvic rhythm during trunk flexion motion.

    abstract::Different standing postures could potentially influence trunk biomechanics during task performance. The current study investigated how foot placement, especially stance width and foot angle influenced lumbopelvic rhythm during sagittal trunk flexion motion. Ten participants performed pace controlled sagittally symmetr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.048

    authors: Zhou J,Ning X,Hu B,Dai B

    更新日期:2016-06-14 00:00:00

  • The potential influence of the heel counter on internal stress during static standing: a combined finite element and positional MRI investigation.

    abstract::Confinement of the heel due to the counter of the shoe is believed to influence heel pad biomechanics. Using a two-dimensional finite element model of the heel pad and shoe during a simulation of static standing, the aim of this study was to quantify the potential effect of confinement on internal heel pad stress. Non...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.01.004

    authors: Spears IR,Miller-Young JE,Sharma J,Ker RF,Smith FW

    更新日期:2007-01-01 00:00:00

  • Physical properties of resistance vessel wall in peripheral blood flow regulation--I. Mathematical model.

    abstract::A mathematical model is introduced to investigate the influence of the physical properties of the resistance vessel wall on the metabolic and myogenic mechanisms. The resistance vessel wall is assumed to have an elastic property and the elastic modulus to be a function of pressure (myogenic) and flow (metabolic). Bloo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90033-x

    authors: Iida N

    更新日期:1989-01-01 00:00:00

  • Sex differences in active tibialis anterior stiffness evaluated using supersonic shear imaging.

    abstract::This study aimed to evaluate the sex difference in active muscle stiffness of the tibialis anterior muscle (TA) through shear modulus measurements performed using supersonic shear imaging (SSI) technique. Twenty-five women and twenty-one men participated in this study. Joint torque, electromyographic (EMG) activity an...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.08.008

    authors: Souron R,Bordat F,Farabet A,Belli A,Feasson L,Nordez A,Lapole T

    更新日期:2016-10-03 00:00:00

  • Squeeze-film lubrication of the human ankle joint with synovial fluid filtrated by articular cartilage with the superficial zone worn out.

    abstract::A squeeze-film lubrication model of the human ankle joint in standing that takes into account the fluid transport across the articular surface is presented. Articular cartilage is a biphasic mixture of the ideal interstitial fluid and an elastic permeable isotropic homogeneous intrinsically incompressible matrix. The ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00109-3

    authors: Hlavácek M

    更新日期:2000-11-01 00:00:00

  • Quantitative associations between osteocyte density and biomechanics, microcrack and microstructure in OVX rats vertebral trabeculae.

    abstract::Osteocytes actively regulate bone modeling and remodeling, direct skeletal mineralization, and regulate calcium/phosphate homeostasis and extracellular matrix metabolism; yet the specific role of osteocytes in maintaining bone structural integrity and strength is unknown. Studies have shown that the density of osteocy...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.01.017

    authors: Ma YL,Dai RC,Sheng ZF,Jin Y,Zhang YH,Fang LN,Fan HJ,Liao EY

    更新日期:2008-01-01 00:00:00