Computational fluid dynamics for the assessment of upper airway response to oral appliance treatment in obstructive sleep apnea.

Abstract:

:Mandibular advancement splints (MAS), which protrude the lower jaw during sleep, are recognized as an effective treatment for obstructive sleep apnea (OSA) through their action of enlarging the airway space and preventing upper airway collapse. However a clinical challenge remains in preselecting patients who will respond to this form of therapy. We aimed to use computational fluid dynamics (CFD) in conjunction with patient upper airway scans to understand the upper airway response to treatment. Seven OSA patients were selected based on their varied treatment response (assessed by the apnea-hypopnoea index (AHI) on overnight polysomnography). Anatomically-accurate upper airway computational models were reconstructed from magnetic resonance images with and without MAS. CFD simulations of airflow were performed at the maximum flow rate during inspiration. A physical airway model of one patient was fabricated and the CFD method was validated against the pressure profile on the physical model. The CFD analysis clearly demonstrated effects of MAS treatment on the patient's UA airflow patterns. The CFD results indicated the lowest pressure often occurs close to the soft palate and the base of the tongue. Percentage change in the square root of airway pressure gradient with MAS (Δsqrt(ΔP(Max))%) was found to have the strongest relationship with treatment response (ΔAHI%) in correlation analysis (r=0.976, p=0.000167). Changes in upper airway geometry alone did not significantly correlate with treatment response. We provide further support of CFD as a potential tool for prediction of treatment outcome with MAS in OSA patients without requiring patient specific flow rates.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Zhao M,Barber T,Cistulli P,Sutherland K,Rosengarten G

doi

10.1016/j.jbiomech.2012.10.033

subject

Has Abstract

pub_date

2013-01-04 00:00:00

pages

142-50

issue

1

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(12)00640-9

journal_volume

46

pub_type

临床试验,杂志文章
  • Tensile stress-strain characteristics of the human meniscal material.

    abstract::The nonlinear stress-strain characteristics of the human menisci were determined by uniaxial elongation tests performed on circumferential and radial specimens prepared from different regions, layers, and locations. The properties of the collagen fibers and the matrix were calculated using the test results along with ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)00081-e

    authors: Tissakht M,Ahmed AM

    更新日期:1995-04-01 00:00:00

  • Proximal femur elastic behaviour is the same in impact and constant displacement rate fall simulation.

    abstract::Understanding proximal femur fracture may yield new targets for fracture prevention screening and treatment. The goal of this study was to characterize force-displacement and failure behaviours in the proximal femur between displacement control and impact loading fall simulations. Twenty-one human proximal femurs were...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.06.040

    authors: Gilchrist S,Nishiyama KK,de Bakker P,Guy P,Boyd SK,Oxland T,Cripton PA

    更新日期:2014-11-28 00:00:00

  • Mechanical recovery of dentin following remineralization in vitro--an indentation study.

    abstract::This study sought to gain insights into the steps leading to remineralization and mechanical recovery of hydrated dentin. Mechanical recovery in water was hypothesized to result from effective mineral matrix binding and to occur from the innermost regions outwards due to an increase in the number of nucleation sites. ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.09.005

    authors: Bertassoni LE,Habelitz S,Marshall SJ,Marshall GW

    更新日期:2011-01-04 00:00:00

  • On the fibre composite material models of disc annulus--comparison of predicted stresses.

    abstract::An axisymmetric finite element model of a body-disc-body unit has been developed and used to study the relative effects of two distinct direction-dependent material representations of the disc annulus on the predicted state of stresses in the disc. The annulus fibrosus is modelled either as nonhomogeneous fibre reinfo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90050-x

    authors: Shirazi-Adl A

    更新日期:1989-01-01 00:00:00

  • The sensitivity of cartilage contact pressures in the knee joint to the size and shape of an anatomically shaped meniscal implant.

    abstract::Since meniscal geometry affects the cartilage contact pressures, it is essential to carefully define the geometry of the synthetic meniscal implant that we developed. Recently, six independent modes of size- and shape-related geometry variation were identified through 3D statistical shape modeling (SSM) of the medial ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.034

    authors: Khoshgoftar M,Vrancken AC,van Tienen TG,Buma P,Janssen D,Verdonschot N

    更新日期:2015-06-01 00:00:00

  • In-vivo analysis of sliding distance and cross-shear in Bi-cruciate retaining total knee arthroplasty.

    abstract::Polyethylene remains the most popular bearing material for total knee arthroplasty (TKA). Despite its widespread use, wear continue to be one of major factors implicated in revision surgery. Sliding distance, cross-shear, and contact stress are the major factors influencing polyethylene wear. As previous studies have ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.06.009

    authors: Arauz P,Peng Y,An S,Kwon YM

    更新日期:2018-08-22 00:00:00

  • Novel compact device for clinically measuring extraocular muscle (EOM) tension.

    abstract::Accurate knowledge of extraocular muscle (EOM) tension is important for the diagnosis of and surgical planning for strabismus, such as choosing which eye to operate or determining the amount of muscle displacement. Previous evaluations of passive EOM tension have relied extensively on the experience and skill of ophth...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109955

    authors: Shin HJ,Lee SJ,Oh CS,Kang H

    更新日期:2020-08-26 00:00:00

  • Elbow and wrist joint contact forces during occupational pick and place activities.

    abstract::A three-dimensional, mathematical model of the elbow and wrist joints, including 15 muscle units, 3 ligaments and 4 joint forces, has been developed. A new strain gauge transducer has been developed to measure functional grip forces. The device measures radial forces divided into six components and forces of up to 250...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00184-0

    authors: Chadwick EK,Nicol AC

    更新日期:2000-05-01 00:00:00

  • Passive stress-strain relation for the right ventricle in diastole.

    abstract::Wall thickness and medial line radii of an in vitro canine heart are measured. These data are assumed to be characteristic of the in vivo ventricles subject to zero pressure, and in the absence of filling. The myocardium is taken to be homogeneous, isotropic, non-linearly elastic, and incompressible. The right ventric...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(82)90171-3

    authors: Moskowitz SE

    更新日期:1982-01-01 00:00:00

  • Simple method for measuring center of mass work during field running.

    abstract::The purpose of this study was to propose and validate a new simple method for calculation of center of mass work during field running, in order to avoid the use of costly and inconvenient measurement devices. This method relies on spring-mass model and measurements of average horizontal velocity, and contact and fligh...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109369

    authors: Devise M,Rossi J,Théveniau N,Belli A

    更新日期:2019-12-03 00:00:00

  • Functional imaging using computational fluid dynamics to predict treatment success of mandibular advancement devices in sleep-disordered breathing.

    abstract::Mandibular advancement devices (MADs) have emerged as a popular alternative for the treatment of sleep-disordered breathing. These devices bring the mandibula forward in order to increase upper airway (UA) volume and prevent total UA collapse during sleep. However, the precise mechanism of action appears to be quite c...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2007.06.022

    authors: De Backer JW,Vanderveken OM,Vos WG,Devolder A,Verhulst SL,Verbraecken JA,Parizel PM,Braem MJ,Van de Heyning PH,De Backer WA

    更新日期:2007-01-01 00:00:00

  • Comparison of blood particle deposition models for non-parallel flow domains.

    abstract::Adhesions of monocytes and platelets to a vascular surface, particularly in regions of flow stagnation, recirculation, and reattachment, are a significant initial event in a broad spectrum of particle-wall interactions that significantly influence the formation of stenotic lesions and mural thrombi. A number of approx...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00434-7

    authors: Worth Longest P,Kleinstreuer C

    更新日期:2003-03-01 00:00:00

  • A fiber-reinforced composite model of the viscoelastic behavior of the brainstem in shear.

    abstract::Brainstem trauma occurs frequently in severe head injury, often resulting in fatal lesions due to importance of brainstem in crucial neural functions. Structurally, the brainstem is composed of bundles of axonal fibers distinctly oriented in a longitudinal direction surrounded by an extracellular matrix. We hypothesiz...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00042-1

    authors: Arbogast KB,Margulies SS

    更新日期:1999-08-01 00:00:00

  • Fabric and elastic principal directions of cancellous bone are closely related.

    abstract::Cancellous bone architecture and mechanics are intimately related. The trabecular architecture of cancellous bone is considered determined by its mechanical environment (Wolff's law), and the mechanical properties of cancellous bone are inversely determined by the trabecular architecture and material properties. Much ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(96)00177-7

    authors: Odgaard A,Kabel J,van Rietbergen B,Dalstra M,Huiskes R

    更新日期:1997-05-01 00:00:00

  • Finding and defining the ideal patellar resection plane in total knee arthroplasty.

    abstract::Asymmetric resection of the patella during total knee arthroplasty (TKA) correlates with anterior knee pain, bony impingement and patellar maltracking. Despite this, there is no consensus regarding the desired landmarks; the cut is often done freehand; and there has been no quantitative comparison of proposed resectio...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2009.06.021

    authors: Anglin C,Fu C,Hodgson AJ,Helmy N,Greidanus NV,Masri BA

    更新日期:2009-10-16 00:00:00

  • Simulation of mechanical behavior of temperature-responsive braided stents made of shape memory polyurethanes.

    abstract::Polymeric stents can be considered as an alternative to metallic stents thanks to their lessened incidence of restenosis and controlled deployment. The purpose of this study was to investigate the feasibility of developing a temperature-responsive braided stent using shape memory polyurethane (SMPU) through finite ele...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.032

    authors: Kim JH,Kang TJ,Yu WR

    更新日期:2010-03-03 00:00:00

  • Regional dependency of the vascular smooth muscle cell contribution to the mechanical properties of the pig ascending aortic tissue.

    abstract:BACKGROUND:Dilation and dissection of aneurysmal ascending aortic tissues occur preferentially at the outer curvature of the vessel. In this study we hypothesize that the density and contractile properties of the vascular smooth muscle cells (VSMCs) of the pig ascending aorta (AA) are heterogeneous and could explain th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.04.018

    authors: Tremblay D,Cartier R,Mongrain R,Leask RL

    更新日期:2010-08-26 00:00:00

  • Trunk stiffness and dynamics during active extension exertions.

    abstract::Spinal stability is related to the recruitment and control of active muscle stiffness. Stochastic system identification techniques were used to calculate the effective stiffness and dynamics of the trunk during active trunk extension exertions. Twenty-one healthy adult subjects (10 males, 11 females) wore a harness wi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.09.014

    authors: Moorhouse KM,Granata KP

    更新日期:2005-10-01 00:00:00

  • Spatial phenotyping of the endocardial endothelium as a function of intracardiac hemodynamic shear stress.

    abstract::Despite substantial evidence for the central role of hemodynamic shear stress in the functional integrity of vascular endothelial cells, hemodynamic and molecular regulation of the endocardial endothelium lining the heart chambers remains understudied. We propose that regional differences in intracardiac hemodynamics ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.018

    authors: McCormick ME,Manduchi E,Witschey WRT,Gorman RC,Gorman JH 3rd,Jiang YZ,Stoeckert CJ Jr,Barker AJ,Yoon S,Markl M,Davies PF

    更新日期:2017-01-04 00:00:00

  • Expedited patient-specific assessment of contact stress exposure in the ankle joint following definitive articular fracture reduction.

    abstract::Acute injury severity, altered joint kinematics, and joint incongruity are three important mechanical factors linked to post-traumatic osteoarthritis (PTOA). Finite element analysis (FEA) was previously used to assess the influence of increased contact stress due to joint incongruity on PTOA development. While promisi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.05.030

    authors: Kern AM,Anderson DD

    更新日期:2015-09-18 00:00:00

  • Precision measurements of the RSA method using a phantom model of hip prosthesis.

    abstract::Radiostereometric analysis (RSA) has become one of the recommended techniques for pre-market evaluation of new joint implant designs. In this study we evaluated the effect of repositioning of X-ray tubes and phantom model on the precision of the RSA method. In precision measurements, we utilized mean error of rigid bo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.09.004

    authors: Mäkinen TJ,Koort JK,Mattila KT,Aro HT

    更新日期:2004-04-01 00:00:00

  • Matrix mechanical properties of transversalis fascia in inguinal herniation as a model for tissue expansion.

    abstract::Inguinal herniation represents a common condition requiring surgical intervention. Despite being regarded as a connective tissue disorder of uncertain cause, research has focused predominantly on biochemical changes in the key tissue layer, the transversalis fascia (TF) with little direct analysis of functional tissue...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.08.018

    authors: Kureshi A,Vaiude P,Nazhat SN,Petrie A,Brown RA

    更新日期:2008-12-05 00:00:00

  • Geometrical resolution limits and detection mechanisms in the oral cavity.

    abstract::The objective of this work is to gain more insight into the processes of oral perception of food texture. Particularly, the limits for detectable thickness differences of objects, which are evaluated in the human mouth, are investigated. In a sensory study small, flexible circular disks (diameter in mm range) of varyi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.04.012

    authors: Strassburg J,Burbidge A,Delgado A,Hartmann C

    更新日期:2007-01-01 00:00:00

  • Material characterization of the brainstem from oscillatory shear tests.

    abstract::Traumatic damage to the brainstem occurs frequently when the brain skull complex experiences injurious loading especially during those traumatic situations that produce diffuse axonal injury (DAI). DAI has been shown to be dependent on load direction and correlated with regional tissue deformation in response to rotat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00068-2

    authors: Arbogast KB,Margulies SS

    更新日期:1998-09-01 00:00:00

  • Mitogen-activated protein kinase signaling in bovine articular chondrocytes in response to fluid flow does not require calcium mobilization.

    abstract::In the present study, the role of mitogen-activated protein kinases (MAPKs) in chondrocyte mechanotransduction was investigated. We hypothesized that MAPKs participate in fluid flow-induced chondrocyte mechanotransduction. To test our hypothesis, we studied cultured chondrocytes subjected to a well-defined mechanical ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00176-1

    authors: Hung CT,Henshaw DR,Wang CC,Mauck RL,Raia F,Palmer G,Chao PH,Mow VC,Ratcliffe A,Valhmu WB

    更新日期:2000-01-01 00:00:00

  • Effect of attachment types and number of implants supporting mandibular overdentures on stress distribution: a computed tomography-based 3D finite element analysis.

    abstract::The objective of this study was to calculate stresses in bone tissue surrounding uncoupled and splinted implants that are induced by a bite force applied to the mandible and to determine whether the number of mandibular overdenture supporting implants in mandibular bone influence the stress distribution. A human adult...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.10.022

    authors: Arat Bilhan S,Baykasoglu C,Bilhan H,Kutay O,Mugan A

    更新日期:2015-01-02 00:00:00

  • Comparison of biomechanical failure criteria for abdominal aortic aneurysm.

    abstract::Medical doctors consider a surgery option for the expanding abdominal aortic aneurysm (AAA) when its maximum diameter reaches 5.5cm. This simple geometrical criterion may possibly underestimate the risks of rupture of small aneurysms as well as overestimate the risks of rupture of large aneurysms. Biomechanical criter...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.03.024

    authors: Volokh KY

    更新日期:2010-07-20 00:00:00

  • Cellular force signal integration through vector logic gates.

    abstract::The multi-signal mechanical environment mammalian cells experience is often unaccounted for in current mechanical stimulation studies. To address this we developed a novel technique to induce dual integrated force inputs, uniaxial stretch and fluid shear stress and present here for the first time a vector logic-gate f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.12.047

    authors: Steward RL Jr,Tan C,Cheng CM,LeDuc PR

    更新日期:2015-02-26 00:00:00

  • A mechanical apparatus with microprocessor controlled stress profile for cyclic compression of cultured articular cartilage explants.

    abstract::An apparatus was designed for mechanical compression of cultured articular cartilage explants with acylindrical plain-ended loading head (diameter 2-5 mm) driven by a stepping motor. A load cell under the culture dish was applied for feedback regulation utilizing a microprocessor-based control unit. The operating prog...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90232-7

    authors: Parkkinen JJ,Lammi MJ,Karjalainen S,Laakkonen J,Hyvärinen E,Tiihonen A,Helminen HJ,Tammi M

    更新日期:1989-01-01 00:00:00

  • Experimentally verified mathematical approach for the prediction of force developed by motor units at variable frequency stimulation patterns.

    abstract::During normal daily activity, muscle motor units (MUs) develop unfused tetanic contractions evoked by trains of motoneuronal firings at variable interpulse intervals (IPIs). The mechanical responses of a MU to successive impulses are not identical. The aim of this study was to develop a mathematical approach for the p...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.01.034

    authors: Raikova R,Rusev R,Drzymała-Celichowska H,Krutki P,Aladjov H,Celichowski J

    更新日期:2010-05-28 00:00:00