A fiber-reinforced composite model of the viscoelastic behavior of the brainstem in shear.

Abstract:

:Brainstem trauma occurs frequently in severe head injury, often resulting in fatal lesions due to importance of brainstem in crucial neural functions. Structurally, the brainstem is composed of bundles of axonal fibers distinctly oriented in a longitudinal direction surrounded by an extracellular matrix. We hypothesize that the oriented structure and architecture of the brainstem dictates this mechanical response and results in its selective vulnerability in rotational loading. In order to understand the relationship between the biologic architecture and the mechanical response and provide further insight into the high vulnerability of this region, a structural and mathematical model was created. A fiber-reinforced composite model composed of viscoelastic fibers surrounded by a viscoelastic matrix was used to relate the biological architecture of the brainstem to its anisotropic mechanical response. Relevant model parameters measured include the brainstem's composite complex moduli and relative fraction of matrix and fiber. The model predicted that the fiber component is three times stiffer and more viscous than the matrix. The fiber modulus predictions were compared with experimental tissue measurements. The optic nerve, a bundle of tightly packed longitudinally arranged myelinated fibers with little matrix, served as a surrogate for the brainstem fiber component. Model predictions agreed with experimental measures, offering a validation of the model. This approach provided an understanding of the relationship between the specific biologic architecture of the brainstem and the anisotropic mechanical response and allowed insight into reasons for the selective vulnerability of this region in rotational head injury.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Arbogast KB,Margulies SS

doi

10.1016/s0021-9290(99)00042-1

keywords:

subject

Has Abstract

pub_date

1999-08-01 00:00:00

pages

865-70

issue

8

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(99)00042-1

journal_volume

32

pub_type

杂志文章
  • The potential influence of the heel counter on internal stress during static standing: a combined finite element and positional MRI investigation.

    abstract::Confinement of the heel due to the counter of the shoe is believed to influence heel pad biomechanics. Using a two-dimensional finite element model of the heel pad and shoe during a simulation of static standing, the aim of this study was to quantify the potential effect of confinement on internal heel pad stress. Non...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.01.004

    authors: Spears IR,Miller-Young JE,Sharma J,Ker RF,Smith FW

    更新日期:2007-01-01 00:00:00

  • Optimization of intravascular shear stress assessment in vivo.

    abstract::The advent of microelectromechanical systems (MEMS) sensors has enabled real-time wall shear stress (WSS) measurements with high spatial and temporal resolution in a 3-D bifurcation model. To optimize intravascular shear stress assessment, we evaluated the feasibility of catheter/coaxial wire-based MEMS sensors in the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.04.021

    authors: Ai L,Yu H,Takabe W,Paraboschi A,Yu F,Kim ES,Li R,Hsiai TK

    更新日期:2009-07-22 00:00:00

  • Pressure distribution over the palm region during forward falls on the outstretched hands.

    abstract::Falls on the outstretched hands are the cause of over 90% of wrist fractures, yet little is known about bone loading during this event. We tested how the magnitude and distribution of pressure over the palm region during a forward fall is affected by foam padding (simulating a glove) and arm configuration, and by the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.09.011

    authors: Choi WJ,Robinovitch SN

    更新日期:2011-02-03 00:00:00

  • The influence of ligament modelling strategies on the predictive capability of finite element models of the human knee joint.

    abstract::In finite element (FE) models knee ligaments can represented either by a group of one-dimensional springs, or by three-dimensional continuum elements based on segmentations. Continuum models closer approximate the anatomy, and facilitate ligament wrapping, while spring models are computationally less expensive. The me...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.08.030

    authors: Naghibi Beidokhti H,Janssen D,van de Groes S,Hazrati J,Van den Boogaard T,Verdonschot N

    更新日期:2017-12-08 00:00:00

  • Mechanical adaptions of collective cells nearby free tissue boundaries.

    abstract::Mechanical adaptions of cells, including stiffness variation, cytoskeleton remodeling, motion coordination, and shape changing, are essential for tissue morphogenesis, wound healing, and malignant progression. In this paper, we take confluent monolayers of Madin-Darby canine kidney (MDCK) and mouse myoblast (C2C12) ce...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109763

    authors: Lv JQ,Chen PC,Góźdź WT,Li B

    更新日期:2020-05-07 00:00:00

  • Cross-sectional structural parameters from densitometry.

    abstract::Bone densitometry has previously been used to obtain cross-sectional properties of bone from a single X-ray projection across the bone width. Using three unique projections, we have extended the method to obtain the principal area moments of inertia and orientations of the principal axes at each scan cross-section alo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00220-2

    authors: Cleek TM,Whalen RT

    更新日期:2002-04-01 00:00:00

  • In vivo porcine left atrial wall stress: Computational model.

    abstract::Most computational models of the heart have so far concentrated on the study of the left ventricle, mainly using simplified geometries. The same approach cannot be adopted to model the left atrium, whose irregular shape does not allow morphological simplifications. In addition, the deformation of the left atrium durin...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.08.023

    authors: Di Martino ES,Bellini C,Schwartzman DS

    更新日期:2011-10-13 00:00:00

  • A method for automated control of belt velocity changes with an instrumented treadmill.

    abstract::Increased practice difficulty during asymmetrical split-belt treadmill rehabilitation has been shown to improve gait outcomes during retention and transfer tests. However, research in this area has been limited by manual treadmill operation. In the case of variable practice, which requires stride-by-stride changes to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.11.017

    authors: Hinkel-Lipsker JW,Hahn ME

    更新日期:2016-01-04 00:00:00

  • Friction-induced whirl vibration: root cause of squeaking in total hip arthroplasty.

    abstract::Squeaking is reported for ceramic-on-ceramic hip arthroplasty, and risk factors leading to this phenomenon have been investigated empirically in the past, this way giving hints to when this phenomenon occurs. The aim of this study is to present an experimentally validated explanation for the dynamical mechanism underl...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.10.025

    authors: Weiss C,Hothan A,Huber G,Morlock MM,Hoffmann NP

    更新日期:2012-01-10 00:00:00

  • Toward quantification of athetotic movements by frequency spectrum analysis.

    abstract::The frequency spectrum of the elbow movements of one normal subject and six handicapped subjects were obtained in order to investigate the possibility of using this technique in quantifying athetosis. The frequency spectrum technique appears to be useful but data from more subjects must be obtained and specific detail...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(85)90046-6

    authors: Niku S,Henderson JM

    更新日期:1985-01-01 00:00:00

  • A constitutive model for vascular tissue that integrates fibril, fiber and continuum levels with application to the isotropic and passive properties of the infrarenal aorta.

    abstract::A fundamental understanding of the mechanical properties of the extracellular matrix (ECM) is critically important to quantify the amount of macroscopic stress and/or strain transmitted to the cellular level of vascular tissue. Structural constitutive models integrate histological and mechanical information, and hence...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.07.015

    authors: Martufi G,Gasser TC

    更新日期:2011-09-23 00:00:00

  • Passive muscle mechanical properties of the medial gastrocnemius in young adults with spastic cerebral palsy.

    abstract::Individuals with spastic cerebral palsy (SCP) exhibit restricted joint range of motion and increased joint stiffness due to structural alterations of their muscles. Little is known about which muscle-tendon structures are responsible for these alterations. The aim of this study was to compare the passive mechanics of ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.06.008

    authors: Barber L,Barrett R,Lichtwark G

    更新日期:2011-09-02 00:00:00

  • Incorporation of vasculature in a head injury model lowers local mechanical strains in dynamic impact.

    abstract::Cerebral vasculature is several orders of magnitude stiffer than the brain tissue. However, only a handful of studies have investigated its potential stiffening effect on dynamic brain strains; yet, they report contradictory findings. Here, we reanalyze the cerebrovascular stiffening effect by incorporating vasculatur...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109732

    authors: Zhao W,Ji S

    更新日期:2020-05-07 00:00:00

  • The role of elastin and collagen in the softening behavior of the human thoracic aortic media.

    abstract::In a previous study we were able to accurately fit experimental data on arterial tissues at supra-physiological loads using a material model that accounts for softening/damage only in the portion of the model associated with the collagen fibers (Weisbecker et al., 2012). Naturally, this result leads to the hypothesis ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.04.025

    authors: Weisbecker H,Viertler C,Pierce DM,Holzapfel GA

    更新日期:2013-07-26 00:00:00

  • Measurement of local diffusion and composition in degraded articular cartilage reveals the unique role of surface structure in controlling macromolecular transport.

    abstract::Developing effective therapeutics for osteoarthritis (OA) necessitates that such molecules can reach and target chondrocytes within articular cartilage. However, predicting how well very large therapeutic molecules diffuse through cartilage is often difficult, and the relationship between local transport mechanics for...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.10.019

    authors: DiDomenico CD,Kaghazchi A,Bonassar LJ

    更新日期:2019-01-03 00:00:00

  • Quantifying thumb opposition kinematics using dynamic computed tomography.

    abstract::Current motion capture techniques all have shortcomings when applied to the 3D quantitative evaluation of thumb base motion. Dynamic CT might overcome these shortcomings but, so far, robustness of this technique in more than one specimen has not yet been demonstrated. The aim of the current study is to further evaluat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.05.008

    authors: Kerkhof FD,Brugman E,D'Agostino P,Dourthe B,van Lenthe GH,Stockmans F,Jonkers I,Vereecke EE

    更新日期:2016-06-14 00:00:00

  • Translational constraint influences dynamic spinal canal occlusion of the thoracic spine: an in vitro experimental study.

    abstract::Mechanical constraints to spine motion can arise in a variety of real-world situations such as when shoulder belts prevent anterior translation of the thorax during automotive collisions. The effect of such constraint on spinal column-spinal cord interaction during injury remains unknown. The purpose of the present st...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.06.030

    authors: Zhu Q,Lane C,Ching RP,Gordon JD,Fisher CG,Dvorak MF,Cripton PA,Oxland TR

    更新日期:2008-01-01 00:00:00

  • The knee joint center of rotation is predominantly on the lateral side during normal walking.

    abstract::The purpose of this study was to test the hypothesis of whether the center of rotation (COR) in the transverse plane of the knee is in the medial side during normal walking in a manner similar to that previously described during non-ambulatory activities. The kinematics for normal knees was obtained from 46 knees duri...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.01.013

    authors: Koo S,Andriacchi TP

    更新日期:2008-01-01 00:00:00

  • Peristaltic transport of blood: Casson model--II.

    abstract::The problem of peristaltic transport of blood in a uniform and non-uniform tube has been investigated, under zero Reynolds number and long wavelength approximation. Blood is represented by a two-layered fluid model consisting of a central layer of suspension of all erythrocytes, etc., assumed to be a Casson fluid, and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(84)90140-4

    authors: Srivastava LM,Srivastava VP

    更新日期:1984-01-01 00:00:00

  • The transmission of translational seat vibration to the head--II. Horizontal seat vibration.

    abstract::The second part of this study of the six axes of head motion caused by translational seat vibration is concerned with the effect of fore-and-aft (x-axis) and lateral (y-axis) seat vibration. Seat-to-head transmissibilities have been determined at frequencies up to 16 Hz for each of the three translational and three ro...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90170-4

    authors: Paddan GS,Griffin MJ

    更新日期:1988-01-01 00:00:00

  • Sensitivity of flow patterns in aneurysms on the anterior communicating artery to anatomic variations of the cerebral arterial network.

    abstract::Recent studies raised increasing concern about the reliability of computer models in reproducing in vivo hemodynamics in cerebral aneurysms. Boundary condition problem is among the most frequently addressed issues since three-dimensional (3-D) modeling is usually restricted to local arterial segments. The present stud...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.09.031

    authors: Liang F,Liu X,Yamaguchi R,Liu H

    更新日期:2016-11-07 00:00:00

  • Serial manipulator functional calibration for in vitro biomechanical testing.

    abstract::Serial manipulators are often used in biomechanical testing of human joints because they are precise, repeatable instruments that can create interesting loading scenarios. Unfortunately, commercial serial manipulators often do not have acceptable global positional accuracy due to manufacturing tolerances, assembly err...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.10.017

    authors: Hill I,Banks S

    更新日期:2014-01-03 00:00:00

  • Compact bone: numerical simulation of mechanical characteristics.

    abstract::One of the main difficulties encountered in the numerical simulation of the anisotropic elastic characteristics of compact bone is to account for the Haversian microstructure when determining the overall macroscopic behavior. Engineering analyses of such problems are usually based on 'homogenized approximations'. Comp...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90031-9

    authors: Crolet JM,Aoubiza B,Meunier A

    更新日期:1993-06-01 00:00:00

  • A reduction of the saddle vertical force triggers the sit-stand transition in cycling.

    abstract::The purpose of the study was to establish the link between the saddle vertical force and its determinants in order to establish the strategies that could trigger the sit-stand transition. We hypothesized that the minimum saddle vertical force would be a critical parameter influencing the sit-stand transition during cy...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.07.035

    authors: Costes A,Turpin NA,Villeger D,Moretto P,Watier B

    更新日期:2015-09-18 00:00:00

  • Coping with perturbations to a layout somersault in tumbling.

    abstract::Tumbling is a dynamic movement requiring control of the linear and angular momenta generated during the approach and takeoff phases. Both of these phases are subject to some variability even when the gymnast is trying to perform a given movement repeatedly. This paper used a simulation model of tumbling takeoff to est...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00077-0

    authors: King MA,Yeadon MR

    更新日期:2003-07-01 00:00:00

  • A three-dimensional human head finite element model and power flow in a human head subject to impact loading.

    abstract::A three-dimensional finite element model of the human head is presented. The model has been validated against two sets of experimental results. To assess injury likelihood of the head subjected to impact loading, the structural intensity (SI) methodology is introduced in accordance with the prevailing practice in expe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.11.015

    authors: Zong Z,Lee HP,Lu C

    更新日期:2006-01-01 00:00:00

  • Changes in the mechanical properties of the trunk in low back pain may be associated with recurrence.

    abstract::Exercise is one of the few effective treatments for LBP. Although exercise is often based on the premise of reduced spinal stiffness, trunk muscle adaptation may increase stiffness. This study developed and validated a method to assess trunk stiffness and damping, and tested these parameters in 14 people with recurrin...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.10.001

    authors: Hodges P,van den Hoorn W,Dawson A,Cholewicki J

    更新日期:2009-01-05 00:00:00

  • Functional imaging using computational fluid dynamics to predict treatment success of mandibular advancement devices in sleep-disordered breathing.

    abstract::Mandibular advancement devices (MADs) have emerged as a popular alternative for the treatment of sleep-disordered breathing. These devices bring the mandibula forward in order to increase upper airway (UA) volume and prevent total UA collapse during sleep. However, the precise mechanism of action appears to be quite c...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2007.06.022

    authors: De Backer JW,Vanderveken OM,Vos WG,Devolder A,Verhulst SL,Verbraecken JA,Parizel PM,Braem MJ,Van de Heyning PH,De Backer WA

    更新日期:2007-01-01 00:00:00

  • Comparison of three local frame definitions for the kinematic analysis of the fingers and the wrist.

    abstract::Because the hand is a complex poly-articular limb, numerous methods have been proposed to investigate its kinematics therefore complicating the comparison between studies and the methodological choices. With the objective of overcoming such issues, the present study compared the effect of three local frame definitions...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.05.025

    authors: Goislard de Monsabert B,Visser JM,Vigouroux L,Van der Helm FC,Veeger HE

    更新日期:2014-08-22 00:00:00

  • The effect on patellofemoral joint stability of selective cutting of lateral retinacular and capsular structures.

    abstract::Patient selection for lateral retinacular release (LRR) and its efficacy are controversial. Iatrogenic medial subluxation can occur with inappropriate LRR. The aim of this study was to determine the reduction in patellofemoral stability with progressively more extensive LRR. The force required to displace the patella ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.11.003

    authors: Merican AM,Kondo E,Amis AA

    更新日期:2009-02-09 00:00:00