In vivo porcine left atrial wall stress: Computational model.

Abstract:

:Most computational models of the heart have so far concentrated on the study of the left ventricle, mainly using simplified geometries. The same approach cannot be adopted to model the left atrium, whose irregular shape does not allow morphological simplifications. In addition, the deformation of the left atrium during the cardiac cycle strongly depends on the interaction with its surrounding structures. We present a procedure to generate a comprehensive computational model of the left atrium, including physiological loads (blood pressure), boundary conditions (pericardium, pulmonary veins and mitral valve annulus movement) and mechanical properties based on planar biaxial experiments. The model was able to accurately reproduce the in vivo dynamics of the left atrium during the passive portion of the cardiac cycle. A shift in time between the peak pressure and the maximum displacement of the mitral valve annulus allows the appendage to inflate and bend towards the ventricle before the pulling effect associated with the ventricle contraction takes place. The ventricular systole creates room for further expansion of the appendage, which gets in close contact with the pericardium. The temporal evolution of the volume in the atrial cavity as predicted by the finite element simulation matches the volume changes obtained from CT scans. The stress field computed at each time point shows remarkable spatial heterogeneity. In particular, high stress concentration occurs along the appendage rim and in the region surrounding the pulmonary veins.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Di Martino ES,Bellini C,Schwartzman DS

doi

10.1016/j.jbiomech.2011.08.023

subject

Has Abstract

pub_date

2011-10-13 00:00:00

pages

2589-94

issue

15

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(11)00583-5

journal_volume

44

pub_type

杂志文章
  • Collagen fibril D-period may change as a function of strain and location in ligament.

    abstract::The purpose of this study was to determine if the characteristic banding pattern (D-period) of collagen fibrils from rabbit medial collateral ligaments changes as a function of gross ligament strain and, if so, whether the changes are location dependent (insertion versus midsubstance). Femur-medial collateral ligament...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00150-0

    authors: Kukreti U,Belkoff SM

    更新日期:2000-12-01 00:00:00

  • Non-Newtonian blood flow in human right coronary arteries: transient simulations.

    abstract::This study looks at pulsatile blood flow through four different right coronary arteries, which have been reconstructed from biplane angiograms. A non-Newtonian blood model (the Generalised Power Law), as well as the usual Newtonian model of blood viscosity, is used to study the wall shear stress in each of these arter...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.01.034

    authors: Johnston BM,Johnston PR,Corney S,Kilpatrick D

    更新日期:2006-01-01 00:00:00

  • Multichannel strain gauge telemetry for orthopaedic implants.

    abstract::In vivo measurements of the loads and deformations occurring in orthopaedic implants will allow future improvements to be made. This paper describes an extremely small telemetry for long term measurements with three strain gauges and methods for an absolutely safe implant design. Developed for measuring the load at hi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90009-7

    authors: Bergmann G,Graichen F,Siraky J,Jendrzynski H,Rohlmann A

    更新日期:1988-01-01 00:00:00

  • Right ventricle in hypoplastic left heart syndrome exhibits altered hemodynamics in the human fetus.

    abstract::Hypoplastic left heart syndrome (HLHS) represents approximately 9% of all congenital heart defects and is one of the most complex, with the left side of the heart being generally underdeveloped. Numerous studies demonstrate that intracardiac fluid flow patterns in the embryonic and fetal circulation can impact cardiac...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110035

    authors: Zebhi B,Wiputra H,Howley L,Cuneo B,Park D,Hoffman H,Gilbert L,Yap CH,Bark D Jr

    更新日期:2020-11-09 00:00:00

  • Direct perfusion measurements of cancellous bone anisotropic permeability.

    abstract::More extensive characterization of trabecular connectivity and intertrabecular space will be instrumental in understanding disease states and designing engineered bone. This project presents an experimental protocol to define the directional dependence of transport properties as measured from healthy cancellous bone w...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00082-3

    authors: Kohles SS,Roberts JB,Upton ML,Wilson CG,Bonassar LJ,Schlichting AL

    更新日期:2001-09-01 00:00:00

  • Steady flow in a model of the human carotid bifurcation. Part I--flow visualization.

    abstract::The geometry of a typical adult human carotid bifurcation, complete with the sinus, was established from a study of a large number of angiograms. A rigid model was constructed from glass and investigations were performed under steady flow conditions using flow visualization techniques over a range of upstream Reynolds...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(82)90057-4

    authors: Bharadvaj BK,Mabon RF,Giddens DP

    更新日期:1982-01-01 00:00:00

  • Pure moment testing for spinal biomechanics applications: Fixed versus sliding ring cable-driven test designs.

    abstract::In vitro multi-axial bending testing using pure moment loading conditions has become the standard in evaluating the effects of different types of surgical intervention on spinal kinematics. Simple, cable-driven experimental set-ups have been widely adopted because they require little infrastructure. Traditionally, "fi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.02.004

    authors: Eguizabal J,Tufaga M,Scheer JK,Ames C,Lotz JC,Buckley JM

    更新日期:2010-05-07 00:00:00

  • Muscle activity patterns altered during pedaling at different body orientations.

    abstract::Gravity is a contributing force that is believed to influence strongly the control of limb movements since it affects sensory input and also contributes to task mechanics. By altering the relative contribution of gravitational force to the overall forces used to control pedaling at different body orientations, we test...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)00038-3

    authors: Brown DA,Kautz SA,Dairaghi CA

    更新日期:1996-10-01 00:00:00

  • Improvement of upper extremity kinematics estimation using a subject-specific forearm model implemented in a kinematic chain.

    abstract::Human movement reconstruction is still difficult due to noise generated by the use of skin markers. The a priori definition of a kinematic chain associated with a global optimisation method allows reducing these deleterious effects. When dealing with the forearm, this approach can be improved by personalising the two ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.01.029

    authors: Fohanno V,Lacouture P,Colloud F

    更新日期:2013-04-05 00:00:00

  • Biomechanical comparison of the human cadaveric pelvis with a fourth generation composite model.

    abstract::The use of cadavers for orthopaedic biomechanics research is well established, but presents difficulties to researchers in terms of cost, biosafety, availability, and ease of use. High fidelity composite models of human bone have been developed for use in biomechanical studies. While several studies have utilized comp...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.12.050

    authors: Girardi BL,Attia T,Backstein D,Safir O,Willett TL,Kuzyk PR

    更新日期:2016-02-29 00:00:00

  • A rigid body model for the assessment of glenohumeral joint mechanics: Influence of osseous defects on range of motion and dislocation.

    abstract::The purpose of this study was to employ subject-specific computer models to evaluate the interaction of glenohumeral range-of-motion and Hill-Sachs humeral head bone defect size on engagement and shoulder dislocation. We hypothesized that the rate of engagement would increase as defect size increased, and that greater...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.11.001

    authors: Welsh MF,Willing RT,Giles JW,Athwal GS,Johnson JA

    更新日期:2016-02-29 00:00:00

  • Effect of scaffold material, construct length and mechanical stimulation on the in vitro stiffness of the engineered tendon construct.

    abstract::Introducing mesenchymal stem cell (MSC)-seeded collagen constructs into load-protected wound sites in the rabbit patellar and Achilles tendons significantly improves their repair outcome compared to natural healing of the unfilled defect. However, these constructs would not be acceptable alternatives for repairing com...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.11.009

    authors: Nirmalanandhan VS,Rao M,Shearn JT,Juncosa-Melvin N,Gooch C,Butler DL

    更新日期:2008-01-01 00:00:00

  • Functional strain in bone tissue as an objective, and controlling stimulus for adaptive bone remodelling.

    abstract::The skeleton consists of a series of elements with a variety of functions. In locations where shape or protection are of prime importance the bone's architecture is achieved during growth under direct genetic control. In locations where resistance to repetitive loading is important only the general form of the bone wi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/0021-9290(87)90026-1

    authors: Lanyon LE

    更新日期:1987-01-01 00:00:00

  • Gait dynamics on an inclined walkway.

    abstract:OBJECTIVE:This paper documents research that quantifies and describes the biomechanics of normal gait on inclined surfaces. DESIGN:Experimental, investigative. BACKGROUND:It is necessary to walk on inclined surfaces to negotiate the natural and built environments. Little research has been conducted on the biomechanic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.07.025

    authors: McIntosh AS,Beatty KT,Dwan LN,Vickers DR

    更新日期:2006-01-01 00:00:00

  • Understanding stress concentration about a nutrient foramen.

    abstract::We investigated the microstructural basis of a reduced stress concentration around the primary nutrient foramen of the equine third metacarpus. We quantified the spatial variations of compositional parameters (mineral content, volume fraction, histological architecture, and osteonal trajectories) from microradiographs...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00130-1

    authors: Götzen N,Cross AR,Ifju PG,Rapoff AJ

    更新日期:2003-10-01 00:00:00

  • Representative 3D shape of the distal femur, modes of variation and relationship with abnormality of the trochlear region.

    abstract::The anatomy of the distal femur has a predominant influence on the mechanics of both patello- and tibio-femoral joints. Especially, the morphological degeneration of the trochlear region dramatically affects the overall knee biomechanics and, from a clinical point of view, the staging of such a degeneration is fundame...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.07.008

    authors: Cerveri P,Belfatto A,Manzotti A

    更新日期:2019-09-20 00:00:00

  • Non-invasive determination of cartilage thickness throughout joint surfaces using magnetic resonance imaging.

    abstract::Data on articular cartilage thickness in the living are important for the design for computer models, aimed at preoperatively assessing the effect of surgical procedures on joint contact and load transmission, and for the calculation of cartilage material properties from its deformational behavior as determined during...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)81146-3

    authors: Eckstein F,Adam C,Sittek H,Becker C,Milz S,Schulte E,Reiser M,Putz R

    更新日期:1997-03-01 00:00:00

  • Frequency content of normal and diabetic plantar pressure profiles: implications for the selection of transducer sizes.

    abstract::How small do pressure transducers need to be in order to faithfully measure the plantar pressure profiles (PPPs) under normal and diabetic feet? In this study, pressures were collected from five diabetic and six non-diabetic subjects using a commercial measurement system with 25 mm2 transducers. Discrete Fourier Trans...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00116-6

    authors: Davis BL,Cothren RM,Quesada P,Hanson SB,Perry JE

    更新日期:1996-07-01 00:00:00

  • The knee joint center of rotation is predominantly on the lateral side during normal walking.

    abstract::The purpose of this study was to test the hypothesis of whether the center of rotation (COR) in the transverse plane of the knee is in the medial side during normal walking in a manner similar to that previously described during non-ambulatory activities. The kinematics for normal knees was obtained from 46 knees duri...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.01.013

    authors: Koo S,Andriacchi TP

    更新日期:2008-01-01 00:00:00

  • Compensation for inertial and gravity effects in a moving force platform.

    abstract::Force plates for human movement analysis provide accurate measurements when mounted rigidly on an inertial reference frame. Large measurement errors occur, however, when the force plate is accelerated, or tilted relative to gravity. This prohibits the use of force plates in human perturbation studies with controlled s...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.05.009

    authors: Hnat SK,van Basten BJH,van den Bogert AJ

    更新日期:2018-06-25 00:00:00

  • An inverse finite-element model of heel-pad indentation.

    abstract::A numerical-experimental approach has been developed to characterize heel-pad deformation at the material level. Left and right heels of 20 diabetic subjects and 20 nondiabetic subjects matched for age, gender and body mass index were indented using force-controlled ultrasound. Initial tissue thickness and deformation...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.03.007

    authors: Erdemir A,Viveiros ML,Ulbrecht JS,Cavanagh PR

    更新日期:2006-01-01 00:00:00

  • A unified multiscale mechanical model for soft collagenous tissues with regular fiber arrangement.

    abstract::In this paper the mechanical response of soft collagenous tissues with regular fiber arrangement (RSCTs) is described by means of a nanoscale model and a two-step micro-macro homogenization technique. The non-linear collagen constitutive behavior is modeled at the nanoscale by a novel approach accounting for entropic ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.07.040

    authors: Maceri F,Marino M,Vairo G

    更新日期:2010-01-19 00:00:00

  • An instrumented tissue tester for measuring soft tissue property under the metatarsal heads in relation to metatarsophalangeal joint angle.

    abstract::Identification of the localized mechanical response of the plantar soft tissue pads underneath the metatarsal heads (i.e., sub-MTH pad) to external loading is key to understand and predict how it functions in a gait cycle. The mechanical response depends on various parameters, such as the external load (direction and ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.03.031

    authors: Chen WM,Phyau-Wui Shim V,Park SB,Lee T

    更新日期:2011-06-03 00:00:00

  • Cross-sectional structural parameters from densitometry.

    abstract::Bone densitometry has previously been used to obtain cross-sectional properties of bone from a single X-ray projection across the bone width. Using three unique projections, we have extended the method to obtain the principal area moments of inertia and orientations of the principal axes at each scan cross-section alo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00220-2

    authors: Cleek TM,Whalen RT

    更新日期:2002-04-01 00:00:00

  • Comparison of mechanical energy expenditure of joint moments and muscle forces during human locomotion.

    abstract::The mechanical energy expenditures (MEEs) of two human lower extremity models with different sources of mechanical energy - (1) muscles and (2) joint moments - were compared theoretically. Sources of mechanical energy producing movement of Model 1 were eight muscle, three of which were two-joint muscles. Sources of me...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00083-6

    authors: Prilutsky BI,Petrova LN,Raitsin LM

    更新日期:1996-04-01 00:00:00

  • Microdamage evaluation in human trabecular bone based on nonlinear ultrasound vibro-modulation (NUVM).

    abstract::The primary aim of this work is to investigate the potential of nonlinear ultrasound for microdamage detection in human bone. Microdamage evaluation in human bone is of great importance, because it is considered a significant parameter for characterizing fracture risk. Experiments employing nonlinear acoustic vibro-mo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.12.018

    authors: Zacharias K,Balabanidou E,Hatzokos I,Rekanos IT,Trochidis A

    更新日期:2009-03-26 00:00:00

  • Walking speed and spatiotemporal step mean measures are reliable during feedback-controlled treadmill walking; however, spatiotemporal step variability is not reliable.

    abstract::The purpose of the study was to compare the effects of a feedback-controlled treadmill (FeedbackTM) to a traditional fixed-speed treadmill (FixedTM) on spatiotemporal gait means, variability, and dynamics. The study also examined inter-session reliability when using the FeedbackTM. Ten young adults walked on the Feedb...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.11.051

    authors: Wiens C,Denton W,Schieber MN,Hartley R,Marmelat V,Myers SA,Yentes JM

    更新日期:2019-01-23 00:00:00

  • Stepping over an obstacle increases the motions and moments of the joints of the trailing limb in young adults.

    abstract::Tripping over obstacles is the most frequently mentioned causes of falls. Thus, this study was performed to test the hypotheses that when crossing obstacles, toe-obstacle clearance and the three-dimensional motions and moments at the hip, knee, and ankle of the trailing limb (limb crossing the obstacle last) increase ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(96)00161-3

    authors: Chou LS,Draganich LF

    更新日期:1997-04-01 00:00:00

  • The range of axial rotation of the glenohumeral joint.

    abstract::There is a paucity of data in the literature on the restraining effects of the glenohumeral (GH) ligaments; cadaveric testing is one of the best methods for determining the function of these types of tissues. The aim of this work was to commission a custom-made six degrees of freedom (dof) joint loading apparatus and ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.007

    authors: Southgate DF,Hill AM,Alexander S,Wallace AL,Hansen UN,Bull AM

    更新日期:2009-06-19 00:00:00

  • Factors in the propagation of aortic dissections in canine thoracic aortas.

    abstract::Factors were examined which altered the propagation of aortic dissections in canine aortas. Thoracic aortas were removed from sacrificed dogs from the distal end of the arch to the diaphragm. An intimal tear was created at the proximal end of the aorta. The dissection was propagated using a pulsatile pressure system w...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90268-5

    authors: van Baardwijk C,Roach MR

    更新日期:1987-01-01 00:00:00