Factors in the propagation of aortic dissections in canine thoracic aortas.

Abstract:

:Factors were examined which altered the propagation of aortic dissections in canine aortas. Thoracic aortas were removed from sacrificed dogs from the distal end of the arch to the diaphragm. An intimal tear was created at the proximal end of the aorta. The dissection was propagated using a pulsatile pressure system with no flow. The aorta was perfused with a dilute black paint solution, which allowed both video monitoring of the extension of the dissection and measurement of the dissection rate. The dependence of the dissection rate on the variables peak pressure, (dP/dt)max and intimal tear depth was examined. The dissection rate was found to be dependent on (dP/dt)max (p less than 0.005) and the intimal tear depth, expressed as a percentage of wall thickness (p less than 0.01), but not on the peak pressure or intimal tear length. The equation relating the significant variables was log (dissection rate) = (-0.034) X % tear depth +(1.89 +/- 0.56) X (dP/dt)max -(4.3 +/- 1.8); r = 78. Thus a higher (dP/dt)max was associated with a more rapid dissection rate and a deeper intimal tear was associated with a slower dissection rate.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

van Baardwijk C,Roach MR

doi

10.1016/0021-9290(87)90268-5

subject

Has Abstract

pub_date

1987-01-01 00:00:00

pages

67-73

issue

1

eissn

0021-9290

issn

1873-2380

pii

0021-9290(87)90268-5

journal_volume

20

pub_type

杂志文章
  • An ultrasound based non-invasive method for the measurement of intrinsic foot kinematics during gait.

    abstract::Soft tissue artefact (STA) and marker placement variability are sources of error when measuring the intrinsic kinematics of the foot. This study aims to demonstrate a non-invasive, combined ultrasound and motion capture (US/MC) technique to directly measure foot skeletal motion. The novel approach is compared to a sta...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.12.014

    authors: Telfer S,Woodburn J,Turner DE

    更新日期:2014-03-21 00:00:00

  • The role of the lamellar interface during torsional yielding of human cortical bone.

    abstract::Fragility fractures are a result of alterations in bone quantity, tissue properties, applied loads, or a combination of these factors. The current study addresses the contribution of cortical bone tissue properties to skeletal fragility by characterizing the shear damage accumulation processes which occur during torsi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00179-1

    authors: Jepsen KJ,Davy DT,Krzypow DJ

    更新日期:1999-03-01 00:00:00

  • Modela-r as a Froude and Strouhal dimensionless numbers combination for dynamic similarity in running.

    abstract::The aim of this study was to test the hypothesis that running at fixed fractions of Froude (Nfr) and Strouhal (Str) dimensionless numbers combinations induce dynamic similarity between humans of different sizes. Nineteen subjects ran in three experimental conditions, (i) constant speed, (ii) similar speed (Nfr) and (i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.10.012

    authors: Villeger D,Costes A,Watier B,Moretto P

    更新日期:2014-12-18 00:00:00

  • The measurement of body segment inertial parameters using dual energy X-ray absorptiometry.

    abstract::Accurate body segment parameter (BSP) information is required for dynamic analyses of motion and the current methods available for obtaining these BSPs have been criticized. The purpose of this study was to determine whether dual energy X-ray absorptiometry (DXA) could accurately measure the BSPs of scanned objects an...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00227-0

    authors: Durkin JL,Dowling JJ,Andrews DM

    更新日期:2002-12-01 00:00:00

  • Effects of broad frequency vibration on cultured osteoblasts.

    abstract::Bone is subjected in vivo to both high amplitude, low frequency strain, incurred by locomotion, and to low amplitude, broad frequency strain. The biological effects of low amplitude, broad frequency strain are poorly understood. To evaluate the effects of low amplitude strains ranging in frequency from 0 to 50 Hz on o...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00245-2

    authors: Tanaka SM,Li J,Duncan RL,Yokota H,Burr DB,Turner CH

    更新日期:2003-01-01 00:00:00

  • Identification of intrinsic and reflexive contributions to low-back stiffness: medium-term reliability and construct validity.

    abstract::This study aimed at testing the reliability and construct validity of a trunk perturbation protocol (TPP) that estimates the intrinsic and reflexive contributions to low-back stiffness. The TPP consists of a series of pseudorandom position-controlled trunk perturbations in an apparatus measuring forces and displacemen...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.11.036

    authors: Larivière C,Ludvig D,Kearney R,Mecheri H,Caron JM,Preuss R

    更新日期:2015-01-21 00:00:00

  • On the fibre composite material models of disc annulus--comparison of predicted stresses.

    abstract::An axisymmetric finite element model of a body-disc-body unit has been developed and used to study the relative effects of two distinct direction-dependent material representations of the disc annulus on the predicted state of stresses in the disc. The annulus fibrosus is modelled either as nonhomogeneous fibre reinfo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90050-x

    authors: Shirazi-Adl A

    更新日期:1989-01-01 00:00:00

  • Residual force enhancement during submaximal and maximal effort contractions of the plantar flexors across knee angle.

    abstract::Following active muscle lengthening, steady-state isometric force is elevated compared with an isometric contraction without prior lengthening for the same muscle length and activation level. This property of muscle contraction is known as residual force enhancement (RFE). Here, we aimed to determine whether neural fa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.07.019

    authors: Dalton BH,Contento VS,Power GA

    更新日期:2018-09-10 00:00:00

  • Functional imaging using computational fluid dynamics to predict treatment success of mandibular advancement devices in sleep-disordered breathing.

    abstract::Mandibular advancement devices (MADs) have emerged as a popular alternative for the treatment of sleep-disordered breathing. These devices bring the mandibula forward in order to increase upper airway (UA) volume and prevent total UA collapse during sleep. However, the precise mechanism of action appears to be quite c...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2007.06.022

    authors: De Backer JW,Vanderveken OM,Vos WG,Devolder A,Verhulst SL,Verbraecken JA,Parizel PM,Braem MJ,Van de Heyning PH,De Backer WA

    更新日期:2007-01-01 00:00:00

  • Collagen fibril diameters increase and fibril densities decrease in skin subjected to repetitive compressive and shear stresses.

    abstract::Understanding microstructural changes that occur in skin subjected to repetitive mechanical stress is crucial towards the development of therapies to enhance skin adaptation and load tolerance in patients at risk of skin breakdown (e.g. prosthesis users, wheelchair users). To determine if collagen fibril diameter, col...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00145-2

    authors: Sanders JE,Goldstein BS

    更新日期:2001-12-01 00:00:00

  • Estimation of gait kinematics and kinetics from inertial sensor data using optimal control of musculoskeletal models.

    abstract::Inertial sensing enables field studies of human movement and ambulant assessment of patients. However, the challenge is to obtain a comprehensive analysis from low-quality data and sparse measurements. In this paper, we present a method to estimate gait kinematics and kinetics directly from raw inertial sensor data pe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.07.022

    authors: Dorschky E,Nitschke M,Seifer AK,van den Bogert AJ,Eskofier BM

    更新日期:2019-10-11 00:00:00

  • Quantitative detection of cartilage surfaces and ligament geometry of the wrist using an imaging cryomicrotome system.

    abstract::Biomechanical models may aid in improving diagnosis and treatment of wrist joint disorders. As input, geometrical information is required for model development. Previous studies acquired some elements of the average wrist joint geometry. However, there is a close geometric functional match between articulating surface...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.11.003

    authors: Dvinskikh NA,Blankevoort L,Foumani M,Spaan JA,Streekstra GJ

    更新日期:2010-03-22 00:00:00

  • Comparative left-right mechanical testing of cancellous bone from normal femoral heads.

    abstract::In order to assess the potential influence of various physical or chemical treatments on bone grafts, and in particular, on femoral heads to be used as bone grafts, the mechanical symmetry of the femoral head was investigated. Pairs of proximal human femora were harvested and transversally sliced using a coordinate sy...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)00061-9

    authors: Banse X,Delloye C,Cornu O,Bourgois R

    更新日期:1996-10-01 00:00:00

  • Microcracking damage and the fracture process in relation to strain rate in human cortical bone tensile failure.

    abstract::It is difficult to define the 'physiological' mechanical properties of bone. Traumatic failures in-vivo are more likely to be orders of magnitude faster than the quasistatic tests usually employed in-vitro. We have reported recently [Hansen, U., Zioupos, P., Simpson, R., Currey, J.D., Hynd, D., 2008. The effect of str...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.07.025

    authors: Zioupos P,Hansen U,Currey JD

    更新日期:2008-10-20 00:00:00

  • The ground reaction force thresholds for detecting postural stability in participants with and without flat foot.

    abstract::Foot mobility commonly contributes to injury via altered motion of the lower extremities. However, there is a lack of understanding of sensitive kinetic changes with flat foot. The purpose of this study was to investigate the threshold that best distinguishes between participants with and without flat foot. The kineti...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.11.004

    authors: Sung PS

    更新日期:2016-01-04 00:00:00

  • Towards the modelling of ageing and atherosclerosis effects in ApoE(-/-) mice aortic tissue.

    abstract::The goal of this work consists in a quantitative analysis and constitutive modelling of ageing processes associated to plaque formation in mice arteries. Reliable information on the characteristic evolution of pressure-stretch curves due to the ageing effects is extracted from previous inflation test experiments. Furt...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.01.043

    authors: Waffenschmidt T,Cilla M,Sáez P,Pérez MM,Martínez MA,Menzel A,Peña E

    更新日期:2016-08-16 00:00:00

  • The consequences of dehydration-hydration on bone anisotropy and implications on the sublamellar organization of mineralized collagen fibrils.

    abstract::In this study, the effect of dehydration-hydration based sublamellar dimensional change on bone anisotropy was used as a tool to understand sublamellar organization of mineralized collagen fibrils. Bone consists of hydroxyapatite, Type I Collagen, mucopolysaccharides and bone fluid, which associates with bone constitu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109737

    authors: Utku FS

    更新日期:2020-05-07 00:00:00

  • A new technique to study the mechanical properties of collagen lattices.

    abstract::A new technique to study the mechanical properties of collagen lattices or dermal equivalents is described. With the help of the load-extension curve obtained with a uniaxial traction apparatus, a stiffness modulus varying from 0.06 to 1 MPa is calculated from the studied parameters (duration of culture, collagen and ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90250-5

    authors: Chapuis JF,Agache P

    更新日期:1992-01-01 00:00:00

  • Model-based inverse estimation for active contraction stresses of tongue muscles using 3D surface shape in speech production.

    abstract::This paper presents a novel inverse estimation approach for the active contraction stresses of tongue muscles during speech. The proposed method is based on variational data assimilation using a mechanical tongue model and 3D tongue surface shapes for speech production. The mechanical tongue model considers nonlinear ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.09.008

    authors: Koike N,Ii S,Yoshinaga T,Nozaki K,Wada S

    更新日期:2017-11-07 00:00:00

  • Large deforming buoyant embolus passing through a stenotic common carotid artery: a computational simulation.

    abstract::Arterial embolism is responsible for the death of lots of people who suffers from heart diseases. The major risk of embolism in upper limbs is that the ruptured particles are brought into the brain, thus stimulating neurological symptoms or causing the stroke. We presented a computational model using fluid-structure i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.01.020

    authors: Vahidi B,Fatouraee N

    更新日期:2012-04-30 00:00:00

  • Effects of sagittal postural adjustments on seat reaction load.

    abstract::Wheelchair-dependent subjects often adopt a passive sitting posture and suffer from sitting acquired pressure ulcers (PU) that mainly occur when high buttock pressures sustain for a longer period of time. Body posture directly influences seating load and proper postural change is therefore essential. Many subjects can...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.04.012

    authors: van Geffen P,Reenalda J,Veltink PH,Koopman BF

    更新日期:2008-07-19 00:00:00

  • Viscoelastic properties of passive skeletal muscle in compression: stress-relaxation behaviour and constitutive modelling.

    abstract::The compressive properties of skeletal muscle are important in impact biomechanics, rehabilitation engineering and surgical simulation. However, the mechanical behaviour of muscle tissue in compression remains poorly characterised. In this paper, the time-dependent properties of passive skeletal muscle were investigat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.02.007

    authors: Van Loocke M,Lyons CG,Simms CK

    更新日期:2008-01-01 00:00:00

  • Modeling the impact of concomitant aortic stenosis and coarctation of the aorta on left ventricular workload.

    abstract::Coarctation of the aorta (COA) is an obstruction of the aorta and is usually associated with bicuspid and tricuspid aortic valve stenosis (AS). When COA coexists with AS, the left ventricle (LV) is facing a double hemodynamic load: a valvular load plus a vascular load. The objective of this study was to develop a lump...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.08.001

    authors: Keshavarz-Motamed Z,Garcia J,Pibarot P,Larose E,Kadem L

    更新日期:2011-11-10 00:00:00

  • In vivo muscular force analysis during the isometric flexion on a monkey's elbow.

    abstract::An experimental method has been developed to analyse muscular forces and torques in vivo during isometric flexion of the elbow in small monkeys (Macaca fascicularis). A mini-transducer was built with a view to measure forces in situ, without cutting tendons. The positions of tendon insertions were measured on anatomic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90220-5

    authors: Landjerit B,Maton B,Peres G

    更新日期:1988-01-01 00:00:00

  • Directional dependence of hydroxyapatite-collagen interactions on mechanics of collagen.

    abstract::Bone is a biological nanocomposite composed primarily of collagen and hydroxyapatite. The collagen molecules self-assemble to from a structure known as a fibril that comprises of about 85-95% of the total bone protein. In a fibril, the molecular level interactions at the interface between molecular collagen and hydrox...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.02.027

    authors: Katti DR,Pradhan SM,Katti KS

    更新日期:2010-06-18 00:00:00

  • A rigid body model for the assessment of glenohumeral joint mechanics: Influence of osseous defects on range of motion and dislocation.

    abstract::The purpose of this study was to employ subject-specific computer models to evaluate the interaction of glenohumeral range-of-motion and Hill-Sachs humeral head bone defect size on engagement and shoulder dislocation. We hypothesized that the rate of engagement would increase as defect size increased, and that greater...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.11.001

    authors: Welsh MF,Willing RT,Giles JW,Athwal GS,Johnson JA

    更新日期:2016-02-29 00:00:00

  • Comparing different approaches for determining joint torque parameters from isovelocity dynamometer measurements.

    abstract::Strength, or maximum joint torque, is a fundamental factor governing human movement, and is regularly assessed for clinical and rehabilitative purposes as well as for research into human performance. This study aimed to identify the most appropriate protocol for fitting a maximum voluntary torque function to experimen...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.11.024

    authors: Forrester SE,Yeadon MR,King MA,Pain MT

    更新日期:2011-03-15 00:00:00

  • Glenohumeral joint cartilage contact in the healthy adult during scapular plane elevation depression with external humeral rotation.

    abstract::The shoulder (glenohumeral) joint has the greatest range of motion of all human joints; as a result, it is particularly vulnerable to dislocation and injury. The ability to non-invasively quantify in-vivo articular cartilage contact patterns of joints has been and remains a difficult biomechanics problem. As a result,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.06.034

    authors: Massimini DF,Warner JJ,Li G

    更新日期:2014-09-22 00:00:00

  • Influence of curvature dynamics on pulsatile coronary artery flow in a realistic bifurcation model.

    abstract::The coronary arteries undergo large dynamic variations during each cardiac cycle due to their position on the beating heart. The local artery curvature varies significantly. In this study the influence of dynamic curvature on coronary artery hemodynamics is analyzed numerically. A realistic model of the bifurcation of...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.01.021

    authors: Prosi M,Perktold K,Ding Z,Friedman MH

    更新日期:2004-11-01 00:00:00

  • Specimen dimensions influence the measurement of material properties in tendon fascicles.

    abstract::Stress, strain and modulus are regularly used to characterize material properties of tissue samples. However, when comparing results from different studies it is evident the reported material properties, particularly failure strains, vary hugely. The aim of our study was to characterize how and why specimen length and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.04.040

    authors: Legerlotz K,Riley GP,Screen HR

    更新日期:2010-08-26 00:00:00