The measurement of body segment inertial parameters using dual energy X-ray absorptiometry.

Abstract:

:Accurate body segment parameter (BSP) information is required for dynamic analyses of motion and the current methods available for obtaining these BSPs have been criticized. The purpose of this study was to determine whether dual energy X-ray absorptiometry (DXA) could accurately measure the BSPs of scanned objects and thus be used as a tool for measuring the BSPs of human subjects. Whole body mass (WBM) of 11 males was measured from a DXA scan and the values were compared to criterion scale-measured values by calculating the mean percent error. Two objects (plastic cylinder, human cadaver leg) were also scanned and DXA measurements of mass, length, centre of mass location (CM) and moment of inertia about the centre of mass (I(CM)) were made using custom software. Criterion BSP measurements were then made and compared to DXA BSP values by calculating the percent error. Criterion I(CM) measurements of the two objects were made using a pendulum technique and a second criterion I(CM) calculation was made for the cylinder using a geometric formula. A mean percent error of -1.05% +/-1.32% was found for WBM measurements of the human subjects. Errors for the cylinder and cadaver leg were under 3.2% for all BSPs except for I(CM) when DXA was compared to the pendulum method (14.3% and 8.2% for cylinder and leg, respectively). The errors between DXA and the pendulum method were attributed to uncertainty in the pendulum technique (J. Biomech. 2002, in Review). I(CM) error of the cylinder when DXA was compared to the geometric calculation was 2.63%. This error, combined with the low errors for all other BSPs, indicated that DXA can be used as a simple and accurate means of obtaining direct BSP information on living humans.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Durkin JL,Dowling JJ,Andrews DM

doi

10.1016/s0021-9290(02)00227-0

keywords:

subject

Has Abstract

pub_date

2002-12-01 00:00:00

pages

1575-80

issue

12

eissn

0021-9290

issn

1873-2380

pii

S0021929002002270

journal_volume

35

pub_type

杂志文章
  • Apparent mass of the standing human body when using a whole-body vibration training machine: Effect of knee angle and input frequency.

    abstract::Several studies have investigated the transmission of vibration from the vibrating plate of a whole-body vibration training machine (WBVTM) to different locations on the human body. No known work has investigated the interface force between the vibrating plate of the machine and the human body. This paper investigates...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.11.003

    authors: Nawayseh N,Hamdan S

    更新日期:2019-01-03 00:00:00

  • The fixion proximal femur nailing system: biomechanical properties of the nail and a cadaveric study.

    abstract::The treatment of choice for early mobilization of hip fracture is surgery, which traditionally employs side plates and screws or intramedullary nails. We examined the biomechanical properties of a new proximal femoral nail system. The new expandable Fixion proximal femur nailing (PFN) system, made of stainless-steel a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.03.014

    authors: Steinberg EL,Blumberg N,Dekel S

    更新日期:2005-01-01 00:00:00

  • Bone strain sensation via transmembrane potential changes in surface osteoblasts: loading rate and microstructural implications.

    abstract::A model is developed in which osteoblasts can sense the strains applied to a small region of bone through electrical coupling between adjacent cells. The stress-generated potentials within bone are assumed to occur through streaming potentials, and the coupled network of osteocytes is assumed to act in a manner simila...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90048-j

    authors: Harrigan TP,Hamilton JJ

    更新日期:1993-02-01 00:00:00

  • Quality of intertrochanteric cancellous bone as predictor of femoral stem RSA migration in cementless total hip arthroplasty.

    abstract::In cementless total hip arthroplasty, osteoporosis may jeopardize the achievement of immediate stability and lead to migration of anatomically shaped femoral stems. Poor quality of proximal cancellous bone per se may also affect the rate of osseointegration. In a selected group of female total hip arthroplasty patient...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.10.012

    authors: Moritz N,Alm JJ,Lankinen P,Mäkinen TJ,Mattila K,Aro HT

    更新日期:2011-01-11 00:00:00

  • Investigation of the kinetics of anaerobic metabolism by analysis of the performance of elite sprinters.

    abstract::The principal motivation for the present work was the study of the kinetics of anaerobic metabolism. A new mathematical model of the bioenergetics of sprinting, incorporating a three-equation representation of anaerobic metabolism, is developed. Results computed using the model are compared with measured data from the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00035-x

    authors: Ward-Smith AJ,Radford PF

    更新日期:2000-08-01 00:00:00

  • A wax barrier to simulate bone resorption for pre-clinical laboratory models of cemented total hip replacements.

    abstract::Pre-clinical tests are often performed to screen new implant designs, surgical techniques, and cement formulations. In this work, we developed a technique to simulate the cement-bone morphology found with postmortem retrieved cemented hip replacements. With this technique, a soy wax barrier is created along the endost...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.06.029

    authors: Cherukuri AR,Miller MA,Race A,Izant TH,Mann KA

    更新日期:2010-10-19 00:00:00

  • Nonuniform swelling-induced residual strains in articular cartilage.

    abstract::Swelling effects in cartilage originate from an interstitial osmotic pressure generated by the presence of negatively charged proteoglycans in the tissue. This swelling pressure gives rise to a non-zero residual strain in the cartilage solid matrix in the absence of externally applied loads. Previous studies have quan...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00184-5

    authors: Narmoneva DA,Wang JY,Setton LA

    更新日期:1999-04-01 00:00:00

  • The effect of swimming activity on bone architecture in growing rats.

    abstract::The effect of non-habitual physical activity on bone architecture in the rat humeral shaft was examined. Two groups of rats were trained to swim for 1 h a day, for 20 weeks, at two training levels. The control group consisted of sedentary rats. Parameters of cross-sectional bone morphology (cross-section areas, princi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90068-7

    authors: Simkin A,Leichter I,Swissa A,Samueloff S

    更新日期:1989-01-01 00:00:00

  • Humans control stride-to-stride stepping movements differently for walking and running, independent of speed.

    abstract::As humans walk or run, external (environmental) and internal (physiological) disturbances induce variability. How humans regulate this variability from stride-to-stride can be critical to maintaining balance. One cannot infer what is "controlled" based on analyses of variability alone. Assessing control requires quant...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.05.034

    authors: Dingwell JB,Bohnsack-McLagan NK,Cusumano JP

    更新日期:2018-07-25 00:00:00

  • Experimental measurement and quantification of frictional contact between biological surfaces experiencing large deformation and slip.

    abstract::Interactions between contacting biological surfaces may play significant roles in physiological and pathological processes. Theoretical models have described some special cases of contact, using one or more simplifying assumptions. Experimental quantification of contact could help to validate theoretical analyses. The...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.01.006

    authors: Gratz KR,Sah RL

    更新日期:2008-01-01 00:00:00

  • A mechanical approach to the longitudinal dispersion of gas flowing in human airways.

    abstract::The aim of this work is to contribute to elucidating the mechanism underlying gas mixing in the human pulmonary airways. For this purpose, a particular attempt is made to analyse the fluid mechanical aspects of gaseous dispersion using bolus response methods. The experiments were performed on five normal subjects by i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(85)90295-7

    authors: Ben Jebria A

    更新日期:1985-01-01 00:00:00

  • Hip extension, knee flexion paradox: a new mechanism for non-contact ACL injury.

    abstract::Considering that an athlete performs at-risk sports activities countless times throughout the course of his or her career prior to the instance of anterior cruciate ligament (ACL) injury, one may conclude that non-contact ACL injury is a rare event. Nevertheless, the overall number of non-contact ACL injuries, both in...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.11.013

    authors: Hashemi J,Breighner R,Chandrashekar N,Hardy DM,Chaudhari AM,Shultz SJ,Slauterbeck JR,Beynnon BD

    更新日期:2011-02-24 00:00:00

  • The utility of an empirically derived co-activation ratio for muscle force prediction through optimization.

    abstract::Biomechanical optimization models that apply efficiency-based objective functions often underestimate or negate antagonist co-activation. Co-activation assists movement control, joint stabilization and limb stiffness and should be carefully incorporated into models. The purposes of this study were to mathematically de...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.02.077

    authors: Brookham RL,Middlebrook EE,Grewal TJ,Dickerson CR

    更新日期:2011-05-17 00:00:00

  • Blood flow patterns and pressure loss in the ascending aorta: A comparative study on physiological and aneurysmal conditions.

    abstract::An aortic aneurysm is defined as a balloon-shaped bulging of all three histologic components of the aortic vessel walls (intima, media and adventitia). This dilation results from vessel weakening owing to remodeling, i.e. due to cystic degeneration of the Tunica media (Marfan), progression of atherosclerosis or presen...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.05.033

    authors: Gülan U,Calen C,Duru F,Holzner M

    更新日期:2018-07-25 00:00:00

  • Assessment of mechanical properties of articular cartilage with quantitative three-dimensional ultrashort echo time (UTE) cones magnetic resonance imaging.

    abstract::Conventional magnetic resonance imaging (MRI) is not capable of detecting signal from the deep cartilage due to its short transverse relaxation time (T2). Moreover, several quantitative MRI techniques are significantly influenced by the magic angle effect. The combinations of ultrashort echo time (UTE) MRI with magnet...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110085

    authors: Namiranian B,Jerban S,Ma Y,Dorthe EW,Masoud-Afsahi A,Wong J,Wei Z,Chen Y,D'Lima D,Chang EY,Du J

    更新日期:2020-12-02 00:00:00

  • Opto-mechanical characterization of sclera by polarization sensitive optical coherence tomography.

    abstract::Polarization sensitive optical coherence tomography (PSOCT) is an interferometric technique sensitive to birefringence. Since mechanical loading alters the orientation of birefringent collagen fibrils, we asked if PSOCT can be used to measure local mechanical properties of sclera. Infrared (1300 nm) PSOCT was performe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.03.017

    authors: Shin A,Park J,Demer JL

    更新日期:2018-04-27 00:00:00

  • Comparison of partial least squares regression and principal component regression for pelvic shape prediction.

    abstract::This paper studied two different regression techniques for pelvic shape prediction, i.e., the partial least square regression (PLSR) and the principal component regression (PCR). Three different predictors such as surface landmarks, morphological parameters, or surface models of neighboring structures were used in a c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.11.005

    authors: Schumann S,Nolte LP,Zheng G

    更新日期:2013-01-04 00:00:00

  • Specimen dimensions influence the measurement of material properties in tendon fascicles.

    abstract::Stress, strain and modulus are regularly used to characterize material properties of tissue samples. However, when comparing results from different studies it is evident the reported material properties, particularly failure strains, vary hugely. The aim of our study was to characterize how and why specimen length and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.04.040

    authors: Legerlotz K,Riley GP,Screen HR

    更新日期:2010-08-26 00:00:00

  • Endothelial actin and cell stiffness is modulated by substrate stiffness in 2D and 3D.

    abstract::There is a growing appreciation of the profound effects that passive mechanical properties, especially the stiffness of the local environment, can have on cellular functions. Many experiments are conducted in a 2D geometry (i.e., cells grown on top of substrates of varying stiffness), which is a simplification of the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.02.012

    authors: Byfield FJ,Reen RK,Shentu TP,Levitan I,Gooch KJ

    更新日期:2009-05-29 00:00:00

  • Some mechanical properties of goose femoral cortical bone.

    abstract::The ultimate compressive strength and modulus of elasticity of femoral cortical bone from adult geese (Anser anser), were determined by sex and by quadrant by compressing small right circular cylinders which were 2.4 mm in height and 0.8 mm in diameter. The average ultimate compressive strength was 183 +/- 29 MPa. The...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(83)90108-2

    authors: McAlister GB,Moyle DD

    更新日期:1983-01-01 00:00:00

  • Compensation for inertial and gravity effects in a moving force platform.

    abstract::Force plates for human movement analysis provide accurate measurements when mounted rigidly on an inertial reference frame. Large measurement errors occur, however, when the force plate is accelerated, or tilted relative to gravity. This prohibits the use of force plates in human perturbation studies with controlled s...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.05.009

    authors: Hnat SK,van Basten BJH,van den Bogert AJ

    更新日期:2018-06-25 00:00:00

  • Biomechanists can revolutionize the STEM pipeline by engaging youth athletes in sports-science based STEM outreach.

    abstract::Increasing diversity in the STEM (Science, Technology, Engineering, and Math) fields has become imperative to ensure equitable access to economic opportunity and to provide the technologically adept workforce of the future. The present STEM pipeline preferentially engages youth who are, not only aware of and intereste...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109511

    authors: Drazan JF

    更新日期:2020-01-23 00:00:00

  • Effect of high altitude exposure on the hemodynamics of the bidirectional Glenn physiology: modeling incremented pulmonary vascular resistance and heart rate.

    abstract::The considerable blood mixing in the bidirectional Glenn (BDG) physiology further limits the capacity of the single working ventricle to pump enough oxygenated blood to the circulatory system. This condition is exacerbated under severe conditions such as physical activity or high altitude. In this study, the effect of...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.03.021

    authors: Vallecilla C,Khiabani RH,Sandoval N,Fogel M,Briceño JC,Yoganathan AP

    更新日期:2014-06-03 00:00:00

  • "Whither flows the fluid in bone?" An osteocyte's perspective.

    abstract::Bone represents a porous tissue containing a fluid phase, a solid matrix, and cells. Movement of the fluid phase within the pores or spaces of the solid matrix translates endogenous and exogenous mechanobiological, biochemical and electromechanical signals from the system that is exposed to the dynamic external enviro...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/s0021-9290(03)00123-4

    authors: Knothe Tate ML

    更新日期:2003-10-01 00:00:00

  • Using smart garments to differentiate among normal and simulated abnormal gaits.

    abstract::Detecting and assessing an individual's gait can be important for medical diagnostic purposes and for developing and guiding follow-on rehabilitation protocols. Thus, an accurate, objective gait classification system has the potential to facilitate earlier diagnosis and improved clinical decision-making. Systems using...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2019.06.009

    authors: Mokhlespour Esfahani MI,Nussbaum MA

    更新日期:2019-08-27 00:00:00

  • In vivo porcine left atrial wall stress: Effect of ventricular tachypacing on spatial and temporal stress distribution.

    abstract::Animal models of ventricular tachypacing (VTP) have been successfully used to reproduce the relevant features observed in patients with atrial fibrillation, such as increased atrial pressure and volume, ion-channel alterations and fibrosis. After performing VTP on a healthy Yorkshire pig, we measured an increase in vo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.09.003

    authors: Di Martino ES,Bellini C,Schwartzman DS

    更新日期:2011-11-10 00:00:00

  • Flat medial-lateral conformity in total knee replacements does not minimize contact stresses.

    abstract::The potential for wear in UHMWPE components for total knee replacements can be reduced by decreasing the stresses and strains arising from tibial-femoral contact. The conformity of the articular surfaces has a large effect on the resultant stresses, and components that achieve flat medial-lateral contact have been ass...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00172-5

    authors: Rawlinson JJ,Bartel DL

    更新日期:2002-01-01 00:00:00

  • Bivariate optimization of pedalling rate and crank arm length in cycling.

    abstract::The contribution of this paper is a bivariate optimization of cycling performance. Relying on a biomechanical model of the lower limb, a cost function derived from the joint moments developed during cycling is computed. At constant average power, both pedalling rate (i.e. rpm) and crank arm length are systematically v...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90016-4

    authors: Hull ML,Gonzalez H

    更新日期:1988-01-01 00:00:00

  • The consistency of maximum running speed measurements in humans using a feedback-controlled treadmill, and a comparison with maximum attainable speed during overground locomotion.

    abstract::Consistent measurement of maximum running speed overground is problematic due to the difficulty in precise, continual measurement of speed, and the substantial workload in accelerating the body promoting the onset of fatigue. Treadmills remove the requirement for acceleration which enables more repeats. They also allo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.07.024

    authors: Bowtell MV,Tan H,Wilson AM

    更新日期:2009-11-13 00:00:00

  • Mechanisms relating force and high-frequency stiffness in skeletal muscle.

    abstract::Muscle stiffness increases faster than muscle force during the rising phase of a tetanic contraction, and decreases more slowly during the falling phase. Different models of the stiffness arising from series, parallels, and crossbridge elasticity were compared to determine whether they could account quantitatively for...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/0021-9290(90)90037-4

    authors: Bobet J,Stein RB,Oğuztöreli MN