Abstract:
:Accurate body segment parameter (BSP) information is required for dynamic analyses of motion and the current methods available for obtaining these BSPs have been criticized. The purpose of this study was to determine whether dual energy X-ray absorptiometry (DXA) could accurately measure the BSPs of scanned objects and thus be used as a tool for measuring the BSPs of human subjects. Whole body mass (WBM) of 11 males was measured from a DXA scan and the values were compared to criterion scale-measured values by calculating the mean percent error. Two objects (plastic cylinder, human cadaver leg) were also scanned and DXA measurements of mass, length, centre of mass location (CM) and moment of inertia about the centre of mass (I(CM)) were made using custom software. Criterion BSP measurements were then made and compared to DXA BSP values by calculating the percent error. Criterion I(CM) measurements of the two objects were made using a pendulum technique and a second criterion I(CM) calculation was made for the cylinder using a geometric formula. A mean percent error of -1.05% +/-1.32% was found for WBM measurements of the human subjects. Errors for the cylinder and cadaver leg were under 3.2% for all BSPs except for I(CM) when DXA was compared to the pendulum method (14.3% and 8.2% for cylinder and leg, respectively). The errors between DXA and the pendulum method were attributed to uncertainty in the pendulum technique (J. Biomech. 2002, in Review). I(CM) error of the cylinder when DXA was compared to the geometric calculation was 2.63%. This error, combined with the low errors for all other BSPs, indicated that DXA can be used as a simple and accurate means of obtaining direct BSP information on living humans.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Durkin JL,Dowling JJ,Andrews DMdoi
10.1016/s0021-9290(02)00227-0keywords:
subject
Has Abstractpub_date
2002-12-01 00:00:00pages
1575-80issue
12eissn
0021-9290issn
1873-2380pii
S0021929002002270journal_volume
35pub_type
杂志文章abstract::Several studies have investigated the transmission of vibration from the vibrating plate of a whole-body vibration training machine (WBVTM) to different locations on the human body. No known work has investigated the interface force between the vibrating plate of the machine and the human body. This paper investigates...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.11.003
更新日期:2019-01-03 00:00:00
abstract::The treatment of choice for early mobilization of hip fracture is surgery, which traditionally employs side plates and screws or intramedullary nails. We examined the biomechanical properties of a new proximal femoral nail system. The new expandable Fixion proximal femur nailing (PFN) system, made of stainless-steel a...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.03.014
更新日期:2005-01-01 00:00:00
abstract::A model is developed in which osteoblasts can sense the strains applied to a small region of bone through electrical coupling between adjacent cells. The stress-generated potentials within bone are assumed to occur through streaming potentials, and the coupled network of osteocytes is assumed to act in a manner simila...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(93)90048-j
更新日期:1993-02-01 00:00:00
abstract::In cementless total hip arthroplasty, osteoporosis may jeopardize the achievement of immediate stability and lead to migration of anatomically shaped femoral stems. Poor quality of proximal cancellous bone per se may also affect the rate of osseointegration. In a selected group of female total hip arthroplasty patient...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.10.012
更新日期:2011-01-11 00:00:00
abstract::The principal motivation for the present work was the study of the kinetics of anaerobic metabolism. A new mathematical model of the bioenergetics of sprinting, incorporating a three-equation representation of anaerobic metabolism, is developed. Results computed using the model are compared with measured data from the...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(00)00035-x
更新日期:2000-08-01 00:00:00
abstract::Pre-clinical tests are often performed to screen new implant designs, surgical techniques, and cement formulations. In this work, we developed a technique to simulate the cement-bone morphology found with postmortem retrieved cemented hip replacements. With this technique, a soy wax barrier is created along the endost...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.06.029
更新日期:2010-10-19 00:00:00
abstract::Swelling effects in cartilage originate from an interstitial osmotic pressure generated by the presence of negatively charged proteoglycans in the tissue. This swelling pressure gives rise to a non-zero residual strain in the cartilage solid matrix in the absence of externally applied loads. Previous studies have quan...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(98)00184-5
更新日期:1999-04-01 00:00:00
abstract::The effect of non-habitual physical activity on bone architecture in the rat humeral shaft was examined. Two groups of rats were trained to swim for 1 h a day, for 20 weeks, at two training levels. The control group consisted of sedentary rats. Parameters of cross-sectional bone morphology (cross-section areas, princi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(89)90068-7
更新日期:1989-01-01 00:00:00
abstract::As humans walk or run, external (environmental) and internal (physiological) disturbances induce variability. How humans regulate this variability from stride-to-stride can be critical to maintaining balance. One cannot infer what is "controlled" based on analyses of variability alone. Assessing control requires quant...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.05.034
更新日期:2018-07-25 00:00:00
abstract::Interactions between contacting biological surfaces may play significant roles in physiological and pathological processes. Theoretical models have described some special cases of contact, using one or more simplifying assumptions. Experimental quantification of contact could help to validate theoretical analyses. The...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.01.006
更新日期:2008-01-01 00:00:00
abstract::The aim of this work is to contribute to elucidating the mechanism underlying gas mixing in the human pulmonary airways. For this purpose, a particular attempt is made to analyse the fluid mechanical aspects of gaseous dispersion using bolus response methods. The experiments were performed on five normal subjects by i...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(85)90295-7
更新日期:1985-01-01 00:00:00
abstract::Considering that an athlete performs at-risk sports activities countless times throughout the course of his or her career prior to the instance of anterior cruciate ligament (ACL) injury, one may conclude that non-contact ACL injury is a rare event. Nevertheless, the overall number of non-contact ACL injuries, both in...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.11.013
更新日期:2011-02-24 00:00:00
abstract::Biomechanical optimization models that apply efficiency-based objective functions often underestimate or negate antagonist co-activation. Co-activation assists movement control, joint stabilization and limb stiffness and should be carefully incorporated into models. The purposes of this study were to mathematically de...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.02.077
更新日期:2011-05-17 00:00:00
abstract::An aortic aneurysm is defined as a balloon-shaped bulging of all three histologic components of the aortic vessel walls (intima, media and adventitia). This dilation results from vessel weakening owing to remodeling, i.e. due to cystic degeneration of the Tunica media (Marfan), progression of atherosclerosis or presen...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.05.033
更新日期:2018-07-25 00:00:00
abstract::Conventional magnetic resonance imaging (MRI) is not capable of detecting signal from the deep cartilage due to its short transverse relaxation time (T2). Moreover, several quantitative MRI techniques are significantly influenced by the magic angle effect. The combinations of ultrashort echo time (UTE) MRI with magnet...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.110085
更新日期:2020-12-02 00:00:00
abstract::Polarization sensitive optical coherence tomography (PSOCT) is an interferometric technique sensitive to birefringence. Since mechanical loading alters the orientation of birefringent collagen fibrils, we asked if PSOCT can be used to measure local mechanical properties of sclera. Infrared (1300 nm) PSOCT was performe...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.03.017
更新日期:2018-04-27 00:00:00
abstract::This paper studied two different regression techniques for pelvic shape prediction, i.e., the partial least square regression (PLSR) and the principal component regression (PCR). Three different predictors such as surface landmarks, morphological parameters, or surface models of neighboring structures were used in a c...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2012.11.005
更新日期:2013-01-04 00:00:00
abstract::Stress, strain and modulus are regularly used to characterize material properties of tissue samples. However, when comparing results from different studies it is evident the reported material properties, particularly failure strains, vary hugely. The aim of our study was to characterize how and why specimen length and...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.04.040
更新日期:2010-08-26 00:00:00
abstract::There is a growing appreciation of the profound effects that passive mechanical properties, especially the stiffness of the local environment, can have on cellular functions. Many experiments are conducted in a 2D geometry (i.e., cells grown on top of substrates of varying stiffness), which is a simplification of the ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.02.012
更新日期:2009-05-29 00:00:00
abstract::The ultimate compressive strength and modulus of elasticity of femoral cortical bone from adult geese (Anser anser), were determined by sex and by quadrant by compressing small right circular cylinders which were 2.4 mm in height and 0.8 mm in diameter. The average ultimate compressive strength was 183 +/- 29 MPa. The...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(83)90108-2
更新日期:1983-01-01 00:00:00
abstract::Force plates for human movement analysis provide accurate measurements when mounted rigidly on an inertial reference frame. Large measurement errors occur, however, when the force plate is accelerated, or tilted relative to gravity. This prohibits the use of force plates in human perturbation studies with controlled s...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.05.009
更新日期:2018-06-25 00:00:00
abstract::Increasing diversity in the STEM (Science, Technology, Engineering, and Math) fields has become imperative to ensure equitable access to economic opportunity and to provide the technologically adept workforce of the future. The present STEM pipeline preferentially engages youth who are, not only aware of and intereste...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.109511
更新日期:2020-01-23 00:00:00
abstract::The considerable blood mixing in the bidirectional Glenn (BDG) physiology further limits the capacity of the single working ventricle to pump enough oxygenated blood to the circulatory system. This condition is exacerbated under severe conditions such as physical activity or high altitude. In this study, the effect of...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.03.021
更新日期:2014-06-03 00:00:00
abstract::Bone represents a porous tissue containing a fluid phase, a solid matrix, and cells. Movement of the fluid phase within the pores or spaces of the solid matrix translates endogenous and exogenous mechanobiological, biochemical and electromechanical signals from the system that is exposed to the dynamic external enviro...
journal_title:Journal of biomechanics
pub_type: 杂志文章,评审
doi:10.1016/s0021-9290(03)00123-4
更新日期:2003-10-01 00:00:00
abstract::Detecting and assessing an individual's gait can be important for medical diagnostic purposes and for developing and guiding follow-on rehabilitation protocols. Thus, an accurate, objective gait classification system has the potential to facilitate earlier diagnosis and improved clinical decision-making. Systems using...
journal_title:Journal of biomechanics
pub_type: 临床试验,杂志文章
doi:10.1016/j.jbiomech.2019.06.009
更新日期:2019-08-27 00:00:00
abstract::Animal models of ventricular tachypacing (VTP) have been successfully used to reproduce the relevant features observed in patients with atrial fibrillation, such as increased atrial pressure and volume, ion-channel alterations and fibrosis. After performing VTP on a healthy Yorkshire pig, we measured an increase in vo...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.09.003
更新日期:2011-11-10 00:00:00
abstract::The potential for wear in UHMWPE components for total knee replacements can be reduced by decreasing the stresses and strains arising from tibial-femoral contact. The conformity of the articular surfaces has a large effect on the resultant stresses, and components that achieve flat medial-lateral contact have been ass...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(01)00172-5
更新日期:2002-01-01 00:00:00
abstract::The contribution of this paper is a bivariate optimization of cycling performance. Relying on a biomechanical model of the lower limb, a cost function derived from the joint moments developed during cycling is computed. At constant average power, both pedalling rate (i.e. rpm) and crank arm length are systematically v...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(88)90016-4
更新日期:1988-01-01 00:00:00
abstract::Consistent measurement of maximum running speed overground is problematic due to the difficulty in precise, continual measurement of speed, and the substantial workload in accelerating the body promoting the onset of fatigue. Treadmills remove the requirement for acceleration which enables more repeats. They also allo...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.07.024
更新日期:2009-11-13 00:00:00
abstract::Muscle stiffness increases faster than muscle force during the rising phase of a tetanic contraction, and decreases more slowly during the falling phase. Different models of the stiffness arising from series, parallels, and crossbridge elasticity were compared to determine whether they could account quantitatively for...
journal_title:Journal of biomechanics
pub_type: 杂志文章,评审
doi:10.1016/0021-9290(90)90037-4
更新日期:1990-01-01 00:00:00