In vivo porcine left atrial wall stress: Effect of ventricular tachypacing on spatial and temporal stress distribution.

Abstract:

:Animal models of ventricular tachypacing (VTP) have been successfully used to reproduce the relevant features observed in patients with atrial fibrillation, such as increased atrial pressure and volume, ion-channel alterations and fibrosis. After performing VTP on a healthy Yorkshire pig, we measured an increase in volume of 60%, a two-fold rise in pressure, and a complex pattern of local mechanical, histological and biochemical changes, including a generalized stiffening of the wall. A protocol recently developed was employed to generate computational models of the porcine left atrium mechanics in healthy conditions and after VTP. Comparison of the stress distribution in the healthy vs. VTP case provided a map of how pressure overload affects and modifies left atrium mechanics. Overall, a positive increase in stress was computed after the VTP treatment. Regions of large increase in the stresses post-VTP were the appendage boundaries, the area around the lower pulmonary vein and the area in the front of the atrium towards the appendage. Due to the elevated stress, the back of the atrium mainly modified its mechanical response, while the appendage remodeled both its shape and its mechanical properties. Large changes in the shape of the mitral valve annulus could be observed as a consequence of the remodeling in the front of the atrium. The relation between local mechanical stress and remodeling that emerges from the results is in agreement with our hypothesis that the structural changes in the atrium are a consequence of a stress-mediated mechanism.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Di Martino ES,Bellini C,Schwartzman DS

doi

10.1016/j.jbiomech.2011.09.003

subject

Has Abstract

pub_date

2011-11-10 00:00:00

pages

2755-60

issue

16

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(11)00590-2

journal_volume

44

pub_type

杂志文章
  • On the effects of different strategies in modelling balloon-expandable stenting by means of finite element method.

    abstract::In recent years, computational structural analyses have emerged as important tools to investigate the mechanical response of stent placement into arterial walls. Although most coronary stents are expanded by inflating a polymeric balloon, realistic computational balloon models have been introduced only recently. In th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.01.027

    authors: Gervaso F,Capelli C,Petrini L,Lattanzio S,Di Virgilio L,Migliavacca F

    更新日期:2008-01-01 00:00:00

  • Lumbar spinal muscle activation synergies predicted by multi-criteria cost function.

    abstract::The hypothesis that control of lumbar spinal muscle synergies is biomechanically optimized was studied by comparing EMG data with an analytical model with a multi-component cost function that could include (1) trunk displacements, (2) intervertebral displacements, (3) intervertebral forces; (4) sum of cubed muscle str...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00034-3

    authors: Stokes IA,Gardner-Morse M

    更新日期:2001-06-01 00:00:00

  • Serial manipulator functional calibration for in vitro biomechanical testing.

    abstract::Serial manipulators are often used in biomechanical testing of human joints because they are precise, repeatable instruments that can create interesting loading scenarios. Unfortunately, commercial serial manipulators often do not have acceptable global positional accuracy due to manufacturing tolerances, assembly err...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.10.017

    authors: Hill I,Banks S

    更新日期:2014-01-03 00:00:00

  • Differences in 3D vs. 2D analysis in lumbar spinal fusion simulations.

    abstract::Lumbar interbody fusion is currently the gold standard in treating patients with disc degeneration or segmental instability. Despite it having been used for several decades, the non-union rate remains high. A failed fusion is frequently attributed to an inadequate mechanical environment after instrumentation. Finite e...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.03.009

    authors: Hsu HW,Bashkuev M,Pumberger M,Schmidt H

    更新日期:2018-04-27 00:00:00

  • A novel approach to estimate trabecular bone anisotropy using a database approach.

    abstract::Continuum finite element (FE) models of bones have become a standard pre-clinical tool to estimate bone strength. These models are usually based on clinical CT scans and material properties assigned are chosen as isotropic based only on the density distribution. It has been shown, however, that trabecular bone elastic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.07.042

    authors: Hazrati Marangalou J,Ito K,Cataldi M,Taddei F,van Rietbergen B

    更新日期:2013-09-27 00:00:00

  • Influence of stent height upon stresses on the cusps of closed bioprosthetic valves.

    abstract::A finite element model of a bioprosthetic heart valve was developed to determine the influence of the stent height on leaflet stresses under various pressure loading conditions after valve closure. A nonlinear solution was used to obtain the stresses in the leaflets for stent heights of 14.6 mm, 19.0 mm and 22.0 mm re...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(86)90199-5

    authors: Hamid MS,Sabbah HN,Stein PD

    更新日期:1986-01-01 00:00:00

  • Inter-segmental coordination: motor pattern in humans stepping over an obstacle with mechanical ankle joint friction.

    abstract::This study examined the influence of a mechanical perturbation of the ankle joint on obstacle avoidance pattern. A decoupled control between the distal joint and the combined (hip-knee) proximal joints was observed according to the task requirement. In this context, a greater mechanical friction at the ankle should be...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2004.07.019

    authors: Gueguen N,Charbonneau M,Robert G,Coyle T,Prince F,Mouchnino L

    更新日期:2005-07-01 00:00:00

  • Resonant frequencies of arms and legs identify different walking patterns.

    abstract::The present study is aimed at investigating changes in the coordination of arm and leg movements in young healthy subjects. It was hypothesized that with changes in walking velocity there is a change in frequency and phase coupling between the arms and the legs. In addition, it was hypothesized that the preferred freq...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00020-8

    authors: Wagenaar RC,van Emmerik RE

    更新日期:2000-07-01 00:00:00

  • Extracellular NO signalling from a mechanically stimulated osteocyte.

    abstract::Bone remodelling is a dynamic process that requires the coordinated interaction of osteocytes, osteoblasts, and osteoclasts, collaborating in basic multicellular units (BMUs). Communication between these cells can be by extracellular soluble molecules as well as directly propagating intercellular signalling molecules....

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.02.015

    authors: Vatsa A,Smit TH,Klein-Nulend J

    更新日期:2007-01-01 00:00:00

  • Two strategies of transferring from sit-to-stand; the activation of monoarticular and biarticular muscles.

    abstract::In this study, two different strategies of rising from a chair were compared, using integrated biomechanical and electromyographic analyses. Nine healthy subjects were instructed to rise using two different strategies: natural sit-to-stand transfer (NSTS) and a sit-to-stand transfer with full flexion of the trunk (FST...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90039-6

    authors: Doorenbosch CA,Harlaar J,Roebroeck ME,Lankhorst GJ

    更新日期:1994-11-01 00:00:00

  • Relations between compressive axial forces in an instrumented massive femoral implant, ground reaction forces, and integrated electromyographs from vastus lateralis during various 'osteogenic' exercises.

    abstract::A subject, who had undergone surgery to replace one hip joint and the proximal half of the femur with an instrumented titanium implant, performed brief exercises whilst simultaneous measurements were made of compressive axial force in the implant using short-range wireless telemetry, ground reactions using a Kistler f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(96)00043-7

    authors: Bassey EJ,Littlewood JJ,Taylor SJ

    更新日期:1997-03-01 00:00:00

  • A mathematical model to investigate the effects of intravenous fluid administration and fluid loss.

    abstract::The optimal fluid administration protocol for critically ill perioperative patients is hard to estimate due to the lack of tools to directly measure the patient fluid status. This results in the suboptimal clinical outcome of interventions. Previously developed predictive mathematical models focus on describing the fl...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.03.002

    authors: Rosalina TT,Bouwman RA,van Sambeek MRHM,van de Vosse FN,Bovendeerd PHM

    更新日期:2019-05-09 00:00:00

  • Canine intersegmental hip joint forces and moments before and after cemented total hip replacement.

    abstract::Intersegmental forces and moments (i.e. resultant free body forces and moments computed at the joint centers) were studied in canine hindlimbs before and after cemented total hip replacement (THR). Five large, adult, mixed-breed dogs were selected. Their gait was recorded (while leash-walked) before surgery using high...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90028-l

    authors: Dogan S,Manley PA,Vanderby R Jr,Kohles SS,Hartman LM,McBeath AA

    更新日期:1991-01-01 00:00:00

  • Non-Newtonian blood flow in human right coronary arteries: steady state simulations.

    abstract::This study looks at blood flow through four different right coronary arteries, which have been reconstructed from bi-plane angiograms. Five non-Newtonian blood models, as well as the usual Newtonian model of blood viscosity, are used to study the wall shear stress in each of these arteries at a particular point in the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.09.016

    authors: Johnston BM,Johnston PR,Corney S,Kilpatrick D

    更新日期:2004-05-01 00:00:00

  • Simulation of mechanical behavior of temperature-responsive braided stents made of shape memory polyurethanes.

    abstract::Polymeric stents can be considered as an alternative to metallic stents thanks to their lessened incidence of restenosis and controlled deployment. The purpose of this study was to investigate the feasibility of developing a temperature-responsive braided stent using shape memory polyurethane (SMPU) through finite ele...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.032

    authors: Kim JH,Kang TJ,Yu WR

    更新日期:2010-03-03 00:00:00

  • An application of beam theory to determine the stress and deformation of long bones.

    abstract::We present a generalized beam theory in which deformation and load are determined simultaneously, in order to analyze statically indeterminant problems involving long bones. We regard a long bone as a beam curved in three dimensions for which the cross-sectional properties vary continuously along its length. The theor...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90087-0

    authors: Salathe EP Jr,Arangio GA,Salathe EP

    更新日期:1989-01-01 00:00:00

  • Experimental validation of a time-domain-based wave propagation model of blood flow in viscoelastic vessels.

    abstract::Time-domain-based one-dimensional wave propagation models of the arterial system are preferable over one-dimensional wave propagation models in the frequency domain since the latter neglect the non-linear convection forces present in the physiological situation, especially when the vessel is tapered. Moreover, one-dim...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.09.014

    authors: Bessems D,Giannopapa CG,Rutten MC,van de Vosse FN

    更新日期:2008-01-01 00:00:00

  • In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics.

    abstract::The objective of the current study was to use fluoroscopy to accurately determine the three-dimensional (3D), in vivo, weight-bearing kinematics of 10 normal and five anterior cruciate ligament deficient (ACLD) knees. Patient-specific bone models were derived from computed tomography (CT) data. 3D computer bone models...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2004.02.042

    authors: Dennis DA,Mahfouz MR,Komistek RD,Hoff W

    更新日期:2005-02-01 00:00:00

  • The measurement of body segment inertial parameters using dual energy X-ray absorptiometry.

    abstract::Accurate body segment parameter (BSP) information is required for dynamic analyses of motion and the current methods available for obtaining these BSPs have been criticized. The purpose of this study was to determine whether dual energy X-ray absorptiometry (DXA) could accurately measure the BSPs of scanned objects an...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00227-0

    authors: Durkin JL,Dowling JJ,Andrews DM

    更新日期:2002-12-01 00:00:00

  • A new in vivo technique for determination of femoro-tibial and femoro-patellar 3D kinematics in total knee arthroplasty.

    abstract::Aim was to develop an in vivo technique which allows determination of femoro-tibial and of femoro-patellar 3D-kinematics in TKA simultaneously. The knees of 20 healthy volunteers and of eight patients with TKA (PCR, rotating platform) were investigated. Kinematics analysis was performed in an open MR-system at differe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.03.020

    authors: von Eisenhart-Rothe R,Vogl T,Englmeier KH,Graichen H

    更新日期:2007-01-01 00:00:00

  • The influence of mechanical vibration on local and central balance control.

    abstract::Fall prevention has an indispensable role in enhancing life expectancy and quality of life among older adults. The first step to prevent falls is to devise reliable methods to identify individuals at high fall risk. The purpose of the current study was to assess alterations in local postural muscle and central sensory...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2018.01.027

    authors: Ehsani H,Mohler J,Marlinski V,Rashedi E,Toosizadeh N

    更新日期:2018-04-11 00:00:00

  • Confocal-based cell-specific finite element modeling extended to study variable cell shapes and intracellular structures: the example of the adipocyte.

    abstract::This communication extends the recently reported cell-specific finite element (FE) method in Slomka and Gefen (2010) in which geometrically realistic FE cell models are created from confocal microscopy scans for large deformation analyses. The cell-specific FE method is extended here in the following aspects: (i) we d...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.09.012

    authors: Or-Tzadikario S,Gefen A

    更新日期:2011-02-03 00:00:00

  • A new testing device for measuring gliding resistance and work of flexion in a digit.

    abstract::In order to move the finger the tendon force must overcome the gliding resistance of the tendon as well as the forces to move the joints, finger inertias, and external load. These sources, combined, make up the work of flexion (WOF) which has been experimentally used to evaluate the finger function. In this study, we ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00300-7

    authors: Zhao C,Amadio PC,Berglund L,Zobitz ME,An KN

    更新日期:2003-02-01 00:00:00

  • A new method for the early diagnosis of brain edema/brain swelling. An experimental study in rabbits.

    abstract::The aim of the present work is to develop a non-destructive, non-invasive technique for the early diagnosis of an oncoming brain edema based on the variation of vibration characteristics of the head system (i.e. eigenfrequency spectrum and modal damping). Besides the theoretical model that supports the basic principle...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.11.001

    authors: Kostopoulos V,Douzinas EE,Kypriades EM,Pappas YZ

    更新日期:2006-01-01 00:00:00

  • Three-dimensional mathematical model analysis of the patellofemoral joint.

    abstract::This paper is concerned with a mathematical model analysis of the patellofemoral joint in the human knee, taking into account the articular surface geometry and mechanical properties of the ligament. It was made by the application of a computer-aided design theory (previously studied) and it was possible to express th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90331-g

    authors: Hirokawa S

    更新日期:1991-01-01 00:00:00

  • Effect of the "squat protective response" on impact velocity during backward falls.

    abstract::Risk for injury during a fall depends on the position and velocity of the body segments at the moment of impact. One technique for reducing impact velocity is to absorb energy in the lower extremity muscles during descent, as occurs during squatting or sitting. However, the protective value of this response may depend...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2003.12.015

    authors: Robinovitch SN,Brumer R,Maurer J

    更新日期:2004-09-01 00:00:00

  • Measurements of active myocardial tension under a wide range of physiological loading conditions.

    abstract::Active tension developed while cardiac muscle shortens has been studied extensively under afterloaded isotonic or isovelocity conditions. However, these are not true in vivo loading conditions. To obtain more physiological loading, we controlled sarcomere length to follow the time courses that we observed previously i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(96)00122-4

    authors: Guccione JM,Le Prell GS,de Tombe PP,Hunter WC

    更新日期:1997-02-01 00:00:00

  • Comparison between in vivo and theoretical bite performance: using multi-body modelling to predict muscle and bite forces in a reptile skull.

    abstract::In biomechanical investigations, geometrically accurate computer models of anatomical structures can be created readily using computed-tomography scan images. However, representation of soft tissue structures is more challenging, relying on approximations to predict the muscle loading conditions that are essential in ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.05.037

    authors: Curtis N,Jones ME,Lappin AK,O'Higgins P,Evans SE,Fagan MJ

    更新日期:2010-10-19 00:00:00

  • An ultrasound based non-invasive method for the measurement of intrinsic foot kinematics during gait.

    abstract::Soft tissue artefact (STA) and marker placement variability are sources of error when measuring the intrinsic kinematics of the foot. This study aims to demonstrate a non-invasive, combined ultrasound and motion capture (US/MC) technique to directly measure foot skeletal motion. The novel approach is compared to a sta...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.12.014

    authors: Telfer S,Woodburn J,Turner DE

    更新日期:2014-03-21 00:00:00

  • Fluid load support during localized indentation of cartilage with a spherical probe.

    abstract::Interstitial fluid pressurization, a consequence of a biphasic tissue structure, is essential to the load bearing and lubrication properties of articular cartilage. Focal tissue degradation may interfere with this protective mechanism, eventually leading to gross degeneration and osteoarthritis. Our long-term goal is ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.12.019

    authors: Bonnevie ED,Baro VJ,Wang L,Burris DL

    更新日期:2012-04-05 00:00:00