Extracellular NO signalling from a mechanically stimulated osteocyte.

Abstract:

:Bone remodelling is a dynamic process that requires the coordinated interaction of osteocytes, osteoblasts, and osteoclasts, collaborating in basic multicellular units (BMUs). Communication between these cells can be by extracellular soluble molecules as well as directly propagating intercellular signalling molecules. Key to the understanding of bone remodelling is osteocyte mechanosensing and chemical signalling to the surrounding cells, since osteocytes are believed to be the mechanosensors of bone, responding to mechanical stresses. Nitric oxide (NO) is an important parameter to study osteocyte activation following mechanical loading. It is a small short-lived molecule, which makes its real-time, quantitative monitoring difficult. However, recently we demonstrated that DAR-4M AM chromophore can be used for real-time quantitative monitoring of intracellular NO production in individual cells following mechanical loading. Here we studied if a single mechanically stimulated osteocyte communicates with, and thus activates its surrounding cells via extracellular soluble factors. We monitored quantitatively intracellular NO production in the stimulated osteocyte and in its surrounding osteocytes, which were not interconnected. Mechanical stimulation by microneedle of a single-MLO-Y4 osteocyte-like cell upregulated the average intracellular NO production by 94% in the stimulated cell, and by 31-150% in the surrounding osteocytes. In conclusion, a single osteocyte can disseminate a mechanical stimulus to its surrounding osteocytes via extracellular soluble signalling factors. This reinforces the putative mechanosensory role of osteocytes, and demonstrates a possible mechanism by which a single mechanically stimulated osteocyte can communicate with other cells in a BMU, which might help to better understand the intricacies of intercellular interactions in BMUs and thus bone remodelling.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Vatsa A,Smit TH,Klein-Nulend J

doi

10.1016/j.jbiomech.2007.02.015

subject

Has Abstract

pub_date

2007-01-01 00:00:00

pages

S89-95

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(07)00082-6

journal_volume

40 Suppl 1

pub_type

杂志文章
  • A piecewise mass-spring-damper model of the human breast.

    abstract::Previous models to predict breast movement whilst performing physical activities have, erroneously, assumed uniform elasticity within the breast. Consequently, the predicted displacements have not yet been satisfactorily validated. In this study, real time motion capture of the natural vibrations of a breast that foll...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.11.027

    authors: Cai Y,Chen L,Yu W,Zhou J,Wan F,Suh M,Chow DH

    更新日期:2018-01-23 00:00:00

  • The effect of isolated valgus moments on ACL strain during single-leg landing: a simulation study.

    abstract::Valgus moments on the knee joint during single-leg landing have been suggested as a risk factor for anterior cruciate ligament (ACL) injury. The purpose of this study was to test the influence of isolated valgus moment on ACL strain during single-leg landing. Physiologic levels of valgus moments from an in vivo study ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.10.031

    authors: Shin CS,Chaudhari AM,Andriacchi TP

    更新日期:2009-02-09 00:00:00

  • A novel validation and calibration method for motion capture systems based on micro-triangulation.

    abstract::Motion capture systems are widely used to measure human kinematics. Nevertheless, users must consider system errors when evaluating their results. Most validation techniques for these systems are based on relative distance and displacement measurements. In contrast, our study aimed to analyse the absolute volume accur...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.04.009

    authors: Nagymáté G,Tuchband T,Kiss RM

    更新日期:2018-06-06 00:00:00

  • Virtually optimized insoles for offloading the diabetic foot: A randomized crossover study.

    abstract::Integration of objective biomechanical measures of foot function into the design process for insoles has been shown to provide enhanced plantar tissue protection for individuals at-risk of plantar ulceration. The use of virtual simulations utilizing numerical modeling techniques offers a potential approach to further ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.jbiomech.2017.06.028

    authors: Telfer S,Woodburn J,Collier A,Cavanagh PR

    更新日期:2017-07-26 00:00:00

  • A novel approach to estimate trabecular bone anisotropy using a database approach.

    abstract::Continuum finite element (FE) models of bones have become a standard pre-clinical tool to estimate bone strength. These models are usually based on clinical CT scans and material properties assigned are chosen as isotropic based only on the density distribution. It has been shown, however, that trabecular bone elastic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.07.042

    authors: Hazrati Marangalou J,Ito K,Cataldi M,Taddei F,van Rietbergen B

    更新日期:2013-09-27 00:00:00

  • Reprogramming cardiomyocyte mechanosensing by crosstalk between integrins and hyaluronic acid receptors.

    abstract::The elastic modulus of bioengineered materials has a strong influence on the phenotype of many cells including cardiomyocytes. On polyacrylamide (PAA) gels that are laminated with ligands for integrins, cardiac myocytes develop well organized sarcomeres only when cultured on substrates with elastic moduli in the range...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.11.023

    authors: Chopra A,Lin V,McCollough A,Atzet S,Prestwich GD,Wechsler AS,Murray ME,Oake SA,Kresh JY,Janmey PA

    更新日期:2012-03-15 00:00:00

  • Modeling movement disorders--CRPS-related dystonia explained by abnormal proprioceptive reflexes.

    abstract::Humans control their movements using adaptive proprioceptive feedback from muscle afferents. The interaction between proprioceptive reflexes and biomechanical properties of the limb is essential in understanding the etiology of movement disorders. A non-linear neuromuscular model of the wrist incorporating muscle dyna...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.09.024

    authors: Mugge W,Munts AG,Schouten AC,van der Helm FC

    更新日期:2012-01-03 00:00:00

  • Effect of variable periodontal ligament thickness and its non-linear material properties on the location of a tooth's centre of resistance.

    abstract::In orthodontics, the 3D translational and rotational movement of a tooth is determined by the force-moment system applied and the location of the tooth's centre of resistance (CR). Because of the practical constraints of in-vivo experiments, the finite element (FE) method is commonly used to determine the CR. The obje...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.07.043

    authors: Schmidt F,Lapatki BG

    更新日期:2019-09-20 00:00:00

  • A mechanistic model for internal bone remodeling exhibits different dynamic responses in disuse and overload.

    abstract::Bone is a dynamic tissue which, through the process of bone remodeling in the mature skeleton, renews itself during normal function and adapts to mechanical loads. It is, therefore, important to understand the effect of remodeling on the mechanical function of bone, as well as the effect of the inherent time lag in th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00221-9

    authors: Hazelwood SJ,Bruce Martin R,Rashid MM,Rodrigo JJ

    更新日期:2001-03-01 00:00:00

  • Novel isodamping dynamometer accurately measures plantar flexor function.

    abstract::Isokinetic dynamometers are the gold standard tools used to assess in vivo joint and muscle function in human subjects, however, the large size and high cost of these devices prevents their widespread use outside of traditonal biomechanics labs. In this study, we developed a mobile dynamometer to allow for field measu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110015

    authors: Drazan JF,Hullfish TJ,Baxter JR

    更新日期:2020-10-09 00:00:00

  • Mechanical adaptions of collective cells nearby free tissue boundaries.

    abstract::Mechanical adaptions of cells, including stiffness variation, cytoskeleton remodeling, motion coordination, and shape changing, are essential for tissue morphogenesis, wound healing, and malignant progression. In this paper, we take confluent monolayers of Madin-Darby canine kidney (MDCK) and mouse myoblast (C2C12) ce...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109763

    authors: Lv JQ,Chen PC,Góźdź WT,Li B

    更新日期:2020-05-07 00:00:00

  • The association between negative muscle work and pedaling rate.

    abstract::The objective of this research was to use a pedal force decomposition approach to quantify the amount of negative muscular crank torque generated by a group of competitive cyclists across a range of pedaling rates. We hypothesized that negative muscular crank torque increases at high pedaling rates as a result of the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00100-1

    authors: Neptune RR,Herzog W

    更新日期:1999-10-01 00:00:00

  • Insertion of microneedles into skin: measurement and prediction of insertion force and needle fracture force.

    abstract::As a hybrid between a hypodermic needle and transdermal patch, we have used microfabrication technology to make arrays of micron-scale needles that transport drugs and other compounds across the skin without causing pain. However, not all microneedle geometries are able to insert into skin at reasonable forces and wit...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.12.010

    authors: Davis SP,Landis BJ,Adams ZH,Allen MG,Prausnitz MR

    更新日期:2004-08-01 00:00:00

  • Multichannel strain gauge telemetry for orthopaedic implants.

    abstract::In vivo measurements of the loads and deformations occurring in orthopaedic implants will allow future improvements to be made. This paper describes an extremely small telemetry for long term measurements with three strain gauges and methods for an absolutely safe implant design. Developed for measuring the load at hi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90009-7

    authors: Bergmann G,Graichen F,Siraky J,Jendrzynski H,Rohlmann A

    更新日期:1988-01-01 00:00:00

  • Time-frequency changes in electromyographic signals after hamstring lengthening surgery in children with cerebral palsy.

    abstract::Increased knee flexion during stance is a common gait deviation in the child with cerebral palsy (CP), with distal hamstring lengthening surgeries being an accepted course of treatment. Post-operatively, improvements in gait kinematics have been reported, however little change is noted in the patterns of muscle activi...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2007.01.001

    authors: Lauer RT,Smith BT,Shewokis PA,McCarthy JJ,Tucker CA

    更新日期:2007-01-01 00:00:00

  • Statistical osteoporosis models using composite finite elements: a parameter study.

    abstract::Osteoporosis is a widely spread disease with severe consequences for patients and high costs for health care systems. The disease is characterised by a loss of bone mass which induces a loss of mechanical performance and structural integrity. It was found that transverse trabeculae are thinned and perforated while ver...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.06.017

    authors: Wolfram U,Schwen LO,Simon U,Rumpf M,Wilke HJ

    更新日期:2009-09-18 00:00:00

  • Experimental validation of a time-domain-based wave propagation model of blood flow in viscoelastic vessels.

    abstract::Time-domain-based one-dimensional wave propagation models of the arterial system are preferable over one-dimensional wave propagation models in the frequency domain since the latter neglect the non-linear convection forces present in the physiological situation, especially when the vessel is tapered. Moreover, one-dim...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.09.014

    authors: Bessems D,Giannopapa CG,Rutten MC,van de Vosse FN

    更新日期:2008-01-01 00:00:00

  • The effect of simulated marker misplacement on the interpretation of inter-limb differences during a change of direction task.

    abstract::The objective assessment of biomechanical asymmetries during movement tasks is used to monitor rehabilitation following anterior cruciate ligament reconstruction (ACLR). Marker placement is an important source of methodological variability within human motion analysis. It is currently unclear how marker placement erro...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110184

    authors: McFadden C,Daniels K,Strike S

    更新日期:2020-12-24 00:00:00

  • An instrumented tissue tester for measuring soft tissue property under the metatarsal heads in relation to metatarsophalangeal joint angle.

    abstract::Identification of the localized mechanical response of the plantar soft tissue pads underneath the metatarsal heads (i.e., sub-MTH pad) to external loading is key to understand and predict how it functions in a gait cycle. The mechanical response depends on various parameters, such as the external load (direction and ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.03.031

    authors: Chen WM,Phyau-Wui Shim V,Park SB,Lee T

    更新日期:2011-06-03 00:00:00

  • Insufficient accuracy of the ultrasound-based determination of Achilles tendon cross-sectional area.

    abstract::The accurate assessment of the Achilles tendon cross-sectional area (CSA) is a crucial prerequisite to investigate tendon adaptation and to calculate the tendon Young׳s modulus. Besides magnetic resonance imaging (MRI), ultrasonography emerged as an alternative imaging technique. The purpose of the present study was t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.07.002

    authors: Bohm S,Mersmann F,Schroll A,Mäkitalo N,Arampatzis A

    更新日期:2016-09-06 00:00:00

  • Numerical analysis of Venous External Scaffolding Technology for Saphenous Vein Grafts.

    abstract::This paper presents a method for analyzing and comparing numerically Saphenous Vein Grafts (SVGs) following Coronary Artery Bypass Graft surgery (CABG). The method analyses the flow dynamics inside vein grafts with and without supporting using Venous External Scaffolding Technology (VEST). The numerical method uses pa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.03.011

    authors: Meirson T,Orion E,Avrahami I

    更新日期:2015-07-16 00:00:00

  • The effect of step-wise increased stretching on rat calvarial osteoblast collagen production.

    abstract::Mechanical forces regulate the function of bone cells. In this paper, the effects of cyclic stretching on osteoblasts derived from rat calvaria were studied at a magnitude occurring in physiological loaded bone tissue. A four-point bending apparatus was used to apply cyclic stretching on osteoblasts. Stretching at 500...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00237-9

    authors: Tang LL,Wang YL,Pan J,Cai SX

    更新日期:2004-01-01 00:00:00

  • A novel dual fluoroscopic imaging method for determination of THA kinematics: in-vitro and in-vivo study.

    abstract::Accurate measurement of six-degrees-of-freedom in-vivo kinematics of the total hip arthroplasty (THA) is essential in gaining insights into in-vivo THA performance. The objective of this study was to validate a novel dual fluoroscopy imaging system (DFIS) for determination of the THA kinematics using both in-vitro and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.02.010

    authors: Tsai TY,Li JS,Wang S,Lin H,Malchau H,Li G,Rubash H,Kwon YM

    更新日期:2013-04-26 00:00:00

  • Trunk control during gait: Walking with wide and narrow step widths present distinct challenges.

    abstract::The active control of the trunk plays an important role in frontal plane gait stability. We characterized trunk control in response to different step widths using a novel feedback system and examined the different effects of wide and narrow step widths as they each present unique task demands. Twenty healthy young adu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110135

    authors: Shih HS,Gordon J,Kulig K

    更新日期:2021-01-04 00:00:00

  • Effect of geometrical imperfections in confined compression tests on parameter evaluation of hydrated soft tissues.

    abstract::Experimental tests, such as the confined and unconfined compression and the indentation tests, are traditionally used to determine the poroelastic properties of hydrated soft tissues (HSTs). The purpose of this study was to quantitatively evaluate the reliability of H(A) and K values as identified from experimental co...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.02.020

    authors: Gervaso F,Pennati G,Boschetti F

    更新日期:2007-01-01 00:00:00

  • Three-dimensional intervertebral kinematics in the healthy young adult cervical spine during dynamic functional loading.

    abstract::The objective of this study was to determine the intervertebral kinematics of the young, healthy cervical spine during dynamic, three-dimensional, functional loading. Intervertebral motion was characterized by the range of motion (ROM) and the helical axis of motion (HAM). Biplane radiographs of the cervical spine wer...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.049

    authors: Anderst WJ,Donaldson WF 3rd,Lee JY,Kang JD

    更新日期:2015-05-01 00:00:00

  • Application and validation of the lattice Boltzmann method for modelling flow-related clotting.

    abstract::The purpose of this paper is to present a simple clotting model, based on residence time and shear stress distribution, that can simulate the deposition over time of enzyme-activated milk in an in vitro system. Results for the model are compared with experiments exhibiting clot deposition in the region of a sharp-edge...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.01.026

    authors: Harrison SE,Smith SM,Bernsdorf J,Hose DR,Lawford PV

    更新日期:2007-01-01 00:00:00

  • The role of synovial fluid filtration by cartilage in lubrication of synovial joints--II. Squeeze-film lubrication: homogeneous filtration.

    abstract::A mathematical model of synovial film filtration and synovial gel formation at normal approach of cartilage surfaces in the human hip joint is presented. The biphasic mixture model presented in Part I of this paper [Hlavácek, J. Biomechanics 26, (1993)] for synovial fluid and that of Mow and his collaborators [J. Biom...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90063-k

    authors: Hlavácek M

    更新日期:1993-10-01 00:00:00

  • Control of cellular adhesion and myofibroblastic character with sub-micrometer magnetoelastic vibrations.

    abstract::The effect of sub-cellular mechanical loads on the behavior of fibroblasts was investigated using magnetoelastic (ME) materials, a type of material that produces mechanical vibrations when exposed to an external magnetic AC field. The integration of this functionality into implant surfaces could mitigate excessive fib...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.02.007

    authors: Holmes HR,Vlaisavljevich E,Tan EL,Snyder KL,Ong KG,Rajachar RM

    更新日期:2018-04-11 00:00:00

  • Low-back loading in lifting two loads beside the body compared to lifting one load in front of the body.

    abstract::Low-back load during manual lifting is considered an important risk factor for the occurrence of low-back pain. Splitting a load, so it can be lifted beside the body (one load in each hand), instead of in front of the body, can be expected to reduce low-back load. Twelve healthy young men lifted 10 and 20-kg wide and ...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2008.10.013

    authors: Faber GS,Kingma I,Bakker AJ,van Dieën JH

    更新日期:2009-01-05 00:00:00