The association between negative muscle work and pedaling rate.

Abstract:

:The objective of this research was to use a pedal force decomposition approach to quantify the amount of negative muscular crank torque generated by a group of competitive cyclists across a range of pedaling rates. We hypothesized that negative muscular crank torque increases at high pedaling rates as a result of the activation dynamics associated with muscle force development and the need for movement control, and that there is a correlation between negative muscular crank torque and pedaling rate. To test this hypothesis, data were collected during 60, 75, 90, 105 and 120 revolutions per minute (rpm) pedaling at a power output of 260 W. The statistical analysis supported our hypothesis. A significant pedaling rate effect was detected in the average negative muscular crank torque with all pedaling rates significantly different from each other (p < 0.05). There was no negative muscular crank torque generated at 60 rpm and negligible amounts at 75 and 90 rpm. But substantial negative muscular crank torque was generated at the two highest pedaling rates (105 and 120 rpm) that increased with increasing pedaling rates. This result suggested that there is a correlation between negative muscle work and the pedaling rates preferred by cyclists (near 90 rpm), and that the cyclists' ability to effectively accelerate the crank with the working muscles diminishes at high pedaling rates.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Neptune RR,Herzog W

doi

10.1016/s0021-9290(99)00100-1

keywords:

subject

Has Abstract

pub_date

1999-10-01 00:00:00

pages

1021-6

issue

10

eissn

0021-9290

issn

1873-2380

pii

S0021929099001001

journal_volume

32

pub_type

杂志文章
  • Simulation of mechanical behavior of temperature-responsive braided stents made of shape memory polyurethanes.

    abstract::Polymeric stents can be considered as an alternative to metallic stents thanks to their lessened incidence of restenosis and controlled deployment. The purpose of this study was to investigate the feasibility of developing a temperature-responsive braided stent using shape memory polyurethane (SMPU) through finite ele...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.032

    authors: Kim JH,Kang TJ,Yu WR

    更新日期:2010-03-03 00:00:00

  • Multiple-step model-experiment matching allows precise definition of dynamical leg parameters in human running.

    abstract::The spring-loaded inverted pendulum (SLIP) model is a well established model for describing bouncy gaits like human running. The notion of spring-like leg behavior has led many researchers to compute the corresponding parameters, predominantly stiffness, in various experimental setups and in various ways. However, dif...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.06.030

    authors: Ludwig C,Grimmer S,Seyfarth A,Maus HM

    更新日期:2012-09-21 00:00:00

  • Endothelial actin and cell stiffness is modulated by substrate stiffness in 2D and 3D.

    abstract::There is a growing appreciation of the profound effects that passive mechanical properties, especially the stiffness of the local environment, can have on cellular functions. Many experiments are conducted in a 2D geometry (i.e., cells grown on top of substrates of varying stiffness), which is a simplification of the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.02.012

    authors: Byfield FJ,Reen RK,Shentu TP,Levitan I,Gooch KJ

    更新日期:2009-05-29 00:00:00

  • Mechanical properties of double-stranded DNA biolayers immobilized on microcantilever under axial compression.

    abstract::In label-free biodetections based on microcantilever technology, double-stranded DNA (dsDNA) structures form through the linkage between probe single-stranded DNA (ssDNA) molecules immobilized on solid substrates and target ssDNA molecules in solutions. Mechanical/electrical properties of these biolayers are important...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.050

    authors: Zhang NH,Chen JZ

    更新日期:2009-07-22 00:00:00

  • Parametric and subject-specific finite element modelling of the lower cervical spine. Influence of geometrical parameters on the motion patterns.

    abstract::Morphometrical and postural features of the cervical spine are supposed to significantly influence its biomechanical behaviour. However, the effects of these geometrical parameters are quite difficult to evaluate. An original numerical method is proposed in order to automatically generate parametric and subject-specif...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.04.007

    authors: Laville A,Laporte S,Skalli W

    更新日期:2009-07-22 00:00:00

  • Specimen dimensions influence the measurement of material properties in tendon fascicles.

    abstract::Stress, strain and modulus are regularly used to characterize material properties of tissue samples. However, when comparing results from different studies it is evident the reported material properties, particularly failure strains, vary hugely. The aim of our study was to characterize how and why specimen length and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.04.040

    authors: Legerlotz K,Riley GP,Screen HR

    更新日期:2010-08-26 00:00:00

  • Dynamic interactions between lumbar intervertebral motion segments during forward bending and return.

    abstract::Continuous dynamic multi-segmental studies of lumbar motion have added depth to our understanding of the biomechanics of back pain, but few have attempted to continuously measure the proportions of motion accepted by individual levels. This study attempted to compare the motion contributions of adjacent lumbar levels ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109603

    authors: Breen A,Breen A

    更新日期:2020-03-26 00:00:00

  • Comparison of micro-level and continuum-level voxel models of the proximal femur.

    abstract::Continuum-level finite element (FE) models became standard computational tools for the evaluation of bone mechanical behavior from in vivo computed tomography scans. Such scans do not account for the anisotropy of the bone. Instead, local mechanical properties in the continuum-level FE models are assumed isotropic and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.10.027

    authors: Verhulp E,van Rietbergen B,Huiskes R

    更新日期:2006-01-01 00:00:00

  • An ocular biomechanic model for dynamic simulation of different eye movements.

    abstract::Simulating and analysing eye movement is useful for assessing visual system contribution to discomfort with respect to body movements, especially in virtual environments where simulation sickness might occur. It can also be used in the design of eye prosthesis or humanoid robot eye. In this paper, we present two biome...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.02.006

    authors: Iskander J,Hossny M,Nahavandi S,Del Porto L

    更新日期:2018-04-11 00:00:00

  • Fluid-structure interaction simulation of artificial textile reinforced aortic heart valve: Validation with an in-vitro test.

    abstract::Prosthetic heart valves deployed in the left heart (aortic and mitral) are subjected to harsh hemodynamical conditions. Most of the tissue engineered heart valves have been developed for the low pressure pulmonary position because of the difficulties in fabricating a mechanically strong valve, able to withstand the sy...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.07.018

    authors: Sodhani D,Reese S,Aksenov A,Soğanci S,Jockenhövel S,Mela P,Stapleton SE

    更新日期:2018-09-10 00:00:00

  • Large scale simulation of red blood cell aggregation in shear flows.

    abstract::Aggregation of highly deformable red blood cells (RBCs) significantly affects the blood flow in the human circulatory system. To investigate the effect of deformation and aggregation of RBCs in blood flow, a mathematical model has been established by coupling the interaction between the fluid and the deformable solids...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.05.010

    authors: Xu D,Kaliviotis E,Munjiza A,Avital E,Ji C,Williams J

    更新日期:2013-07-26 00:00:00

  • Effect of scaffold material, construct length and mechanical stimulation on the in vitro stiffness of the engineered tendon construct.

    abstract::Introducing mesenchymal stem cell (MSC)-seeded collagen constructs into load-protected wound sites in the rabbit patellar and Achilles tendons significantly improves their repair outcome compared to natural healing of the unfilled defect. However, these constructs would not be acceptable alternatives for repairing com...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.11.009

    authors: Nirmalanandhan VS,Rao M,Shearn JT,Juncosa-Melvin N,Gooch C,Butler DL

    更新日期:2008-01-01 00:00:00

  • Falls resulting from a laboratory-induced slip occur at a higher rate among individuals who are obese.

    abstract::Falls due to slipping are a serious concern, with slipping estimated to cause 40-50% of all fall-related injuries. Epidemiological data indicates that older and obese adults experience more falls than young, non-obese individuals. An increasingly heavier and older U.S. population and workforce may be exacerbating the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.01.018

    authors: Allin LJ,Wu X,Nussbaum MA,Madigan ML

    更新日期:2016-03-21 00:00:00

  • Failure of mineralized collagen fibrils: modeling the role of collagen cross-linking.

    abstract::Experimental evidence demonstrates that collagen cross-linking in bone tissue significantly influences its deformation and failure behavior yet difficulties exist in determining the independent biomechanical effects of collagen cross-linking using in vitro and in vivo experiments. The aim of this study is to use a nan...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.02.017

    authors: Siegmund T,Allen MR,Burr DB

    更新日期:2008-01-01 00:00:00

  • In-vivo 6 degrees-of-freedom kinematics of metal-on-polyethylene total hip arthroplasty during gait.

    abstract::Knowledge of accurate in-vivo 6 degree-of-freedom (6-DOF) kinematics of total hip arthroplasty (THA) during daily activities is critical for improvement of longevity of the components. Previous studies assessed in-vivo THA kinematics using skin marker-based motion analysis. However, skin markers are prone to move with...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.03.012

    authors: Tsai TY,Li JS,Wang S,Scarborough D,Kwon YM

    更新日期:2014-05-07 00:00:00

  • Hip endoprosthesis for in vivo measurement of joint force and temperature.

    abstract::Friction between the prosthetic head and acetabular cup increases the temperature in hip implants during activities like walking. A hip endoprosthesis was instrumented with sensors to measure the joint contact forces and the temperature distribution along the entire length of the titanium implant. Sensors and two indu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00110-4

    authors: Graichen F,Bergmann G,Rohlmann A

    更新日期:1999-10-01 00:00:00

  • Does screw-bone interface modelling matter in finite element analyses?

    abstract::The effect of screw-bone interface modelling strategies was evaluated in the setting of a tibial mid-shaft fracture stabilised using locking plates. Three interface models were examined: fully bonded interface; screw with sliding contact with bone; and screw with sliding contact with bone in an undersized pilot hole. ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.04.008

    authors: MacLeod AR,Pankaj P,Simpson AH

    更新日期:2012-06-01 00:00:00

  • Tissue viscoelasticity is related to tissue composition but may not fully predict the apparent-level viscoelasticity in human trabecular bone - An experimental and finite element study.

    abstract::Trabecular bone is viscoelastic under dynamic loading. However, it is unclear how tissue viscoelasticity controls viscoelasticity at the apparent-level. In this study, viscoelasticity of cylindrical human trabecular bone samples (n=11, male, age 18-78 years) from 11 proximal femurs were characterized using dynamic and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.10.002

    authors: Ojanen X,Tanska P,Malo MKH,Isaksson H,Väänänen SP,Koistinen AP,Grassi L,Magnusson SP,Ribel-Madsen SM,Korhonen RK,Jurvelin JS,Töyräs J

    更新日期:2017-12-08 00:00:00

  • Biomechanical evaluation of walking and cycling in children.

    abstract::Physical activity in children is important as it leads to healthy growth due to physiological benefits. However, a physiological benefit can be partially negated by excessive or unphysiological loads within the joints. To gain an initial understanding into this, the present study sought to compare joint loading betwee...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.01.051

    authors: Greca JPA,Ryan J,Baltzopoulos V,Korff T

    更新日期:2019-04-18 00:00:00

  • Bivariate optimization of pedalling rate and crank arm length in cycling.

    abstract::The contribution of this paper is a bivariate optimization of cycling performance. Relying on a biomechanical model of the lower limb, a cost function derived from the joint moments developed during cycling is computed. At constant average power, both pedalling rate (i.e. rpm) and crank arm length are systematically v...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90016-4

    authors: Hull ML,Gonzalez H

    更新日期:1988-01-01 00:00:00

  • A 3D skeletal muscle model coupled with active contraction of muscle fibres and hyperelastic behaviour.

    abstract::This paper presents a three-dimensional finite element model of skeletal muscle which was developed to simulate active and passive non-linear mechanical behaviours of the muscle during lengthening or shortening under either quasi-static or dynamic condition. Constitutive relation of the muscle was determined by using ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.01.021

    authors: Tang CY,Zhang G,Tsui CP

    更新日期:2009-05-11 00:00:00

  • Strain shielding in distal femur after patellofemoral arthroplasty under different activity conditions.

    abstract::Strain shielding, a mechanical effect occurring in structures combining stiff with more flexible materials, is considered to lead to a reduction of density in bone surrounding the implant. This effect can be related to the weakness of the implant fixation, which can promote implant loosening. Several studies describe ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.09.048

    authors: Meireles S,Completo A,António Simões J,Flores P

    更新日期:2010-02-10 00:00:00

  • Canine intersegmental hip joint forces and moments before and after cemented total hip replacement.

    abstract::Intersegmental forces and moments (i.e. resultant free body forces and moments computed at the joint centers) were studied in canine hindlimbs before and after cemented total hip replacement (THR). Five large, adult, mixed-breed dogs were selected. Their gait was recorded (while leash-walked) before surgery using high...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90028-l

    authors: Dogan S,Manley PA,Vanderby R Jr,Kohles SS,Hartman LM,McBeath AA

    更新日期:1991-01-01 00:00:00

  • Using force sensing insoles to predict kinetic knee symmetry during a stop jump.

    abstract::Knee kinetic asymmetries are present during jump-landings in athletes returning to sport following anterior cruciate ligament (ACL) reconstruction, and are associated with an increased risk for sustaining a second ACL injury. The loadsol® is a wireless load sensing insole that can be used in non-laboratory settings. T...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.07.037

    authors: Peebles AT,Ford KR,Taylor JB,Hart JM,Sands LP,Queen RM

    更新日期:2019-10-11 00:00:00

  • The influence of center-of-mass movements on the variation in the structure of human postural sway.

    abstract::The present article investigates the influence of center-of-mass movements on the variation of the structure in human postural sway. Twelve healthy younger persons performed 60s quiet standing, 60s relaxed standing, and 10 min relaxed standing on two force plates. Center-of-pressure (CoP) and gravitational line (GL) p...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.10.016

    authors: Ihlen EA,Skjæret N,Vereijken B

    更新日期:2013-02-01 00:00:00

  • Mechanical and metabolic requirements for active lateral stabilization in human walking.

    abstract::Walking appears to be passively unstable in the lateral direction, requiring active feedback control for stability. The central nervous system may control stability by adjusting medio-lateral foot placement, but potentially with a metabolic cost. This cost increases with narrow steps and may affect the preferred step ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.06.002

    authors: Donelan JM,Shipman DW,Kram R,Kuo AD

    更新日期:2004-06-01 00:00:00

  • Use of a statistical model of the whole femur in a large scale, multi-model study of femoral neck fracture risk.

    abstract::Interpatient variability is often overlooked in orthopaedic computational studies due to the substantial challenges involved in sourcing and generating large numbers of bone models. A statistical model of the whole femur incorporating both geometric and material property variation was developed as a potential solution...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.05.038

    authors: Bryan R,Nair PB,Taylor M

    更新日期:2009-09-18 00:00:00

  • Modifying hernia mesh design to improve device mechanical performance and promote tension-free repair.

    abstract:PURPOSE:Approximately 348,000 ventral hernia repairs are performed annually in the United States and the incisional hernia recurrence rate is approximately 20% as a result of suture and mesh device failure. Device failure is related to changes at the suture/tissue interface that leads to acute or chronic suture pull-th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.01.022

    authors: Ibrahim MM,Poveromo LP,Glisson RR,Cornejo A,Farjat AE,Gall K,Levinson H

    更新日期:2018-04-11 00:00:00

  • Improved walking function in laboratory does not guarantee increased community walking in stroke survivors: Potential role of gait biomechanics.

    abstract::Reduced daily stepping in stroke survivors may contribute to decreased functional capacity and increased mortality. We investigated the relationships between clinical and biomechanical walking measures that may contribute to changes in daily stepping activity following physical interventions provided to participants w...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.05.011

    authors: Ardestani MM,Henderson CE,Hornby TG

    更新日期:2019-06-25 00:00:00

  • Mechanical recovery of dentin following remineralization in vitro--an indentation study.

    abstract::This study sought to gain insights into the steps leading to remineralization and mechanical recovery of hydrated dentin. Mechanical recovery in water was hypothesized to result from effective mineral matrix binding and to occur from the innermost regions outwards due to an increase in the number of nucleation sites. ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.09.005

    authors: Bertassoni LE,Habelitz S,Marshall SJ,Marshall GW

    更新日期:2011-01-04 00:00:00