Flat medial-lateral conformity in total knee replacements does not minimize contact stresses.

Abstract:

:The potential for wear in UHMWPE components for total knee replacements can be reduced by decreasing the stresses and strains arising from tibial-femoral contact. The conformity of the articular surfaces has a large effect on the resultant stresses, and components that achieve flat medial-lateral contact have been assumed to produce the lowest stresses due to their perfect conformity. We computed the stresses arising from curved and flat contact on a half-space using two-dimensional, plane strain elasticity solutions and finite element analyses to compare the performance of curved and flat indenters. These indenters were represented by a polynomial so the profiles could be continuously varied from curved to flat. Curved contact resulted in maximum stresses at the center of contact, while flat contact produced maximum stresses at the edge of contact. In addition, three contemporary tibial configurations (flat-on-flat, curved-on-flat, and curved-on-curved geometries) were analyzed using the finite element method with nonlinear material properties. The maximum contact stress, von Mises stress, and von Mises strain were lowest for the curved-on-curved model. The other configurations resulted in higher contact stresses, von Mises stresses, and von Mises strains. The perfect conformity arising from flat contact did not reduce the contact stresses in the UHMWPE component. The tensile stresses, however, were lowest for the flat-on-flat geometry compared with the other two configurations. Relating these distinct differences could prove useful in interpretation of data from simulator and retrieval studies.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Rawlinson JJ,Bartel DL

doi

10.1016/s0021-9290(01)00172-5

keywords:

subject

Has Abstract

pub_date

2002-01-01 00:00:00

pages

27-34

issue

1

eissn

0021-9290

issn

1873-2380

pii

S0021929001001725

journal_volume

35

pub_type

杂志文章
  • Comparison of partial least squares regression and principal component regression for pelvic shape prediction.

    abstract::This paper studied two different regression techniques for pelvic shape prediction, i.e., the partial least square regression (PLSR) and the principal component regression (PCR). Three different predictors such as surface landmarks, morphological parameters, or surface models of neighboring structures were used in a c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.11.005

    authors: Schumann S,Nolte LP,Zheng G

    更新日期:2013-01-04 00:00:00

  • Biomechanical analyses of stair-climbing while dual-tasking.

    abstract::Stair-climbing while doing a concurrent task like talking or holding an object is a common activity of daily living which poses high risk for falls. While biomechanical analyses of overground walking during dual-tasking have been studied extensively, little is known on the biomechanics of stair-climbing while dual-tas...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.024

    authors: Vallabhajosula S,Tan CW,Mukherjee M,Davidson AJ,Stergiou N

    更新日期:2015-04-13 00:00:00

  • Estimation of gait kinematics and kinetics from inertial sensor data using optimal control of musculoskeletal models.

    abstract::Inertial sensing enables field studies of human movement and ambulant assessment of patients. However, the challenge is to obtain a comprehensive analysis from low-quality data and sparse measurements. In this paper, we present a method to estimate gait kinematics and kinetics directly from raw inertial sensor data pe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.07.022

    authors: Dorschky E,Nitschke M,Seifer AK,van den Bogert AJ,Eskofier BM

    更新日期:2019-10-11 00:00:00

  • In vitro analysis of a model of intracardiac jet: analysis of the central core of axisymmetric jets.

    abstract::In order to provide physical information supporting the clinical use of flow mapping, an in vitro model was designed to measure the velocity fields in a pulsatile hydraulic turbulent jet. We used a peak velocity ranging from 2.5 to 5.5 m.s-1, an orifice diameter ranging from 5.8 to 11.3 mm and confined the jet in a re...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90367-c

    authors: Diebold B,Delouche A,Dumée P,Guglielmi JP,Delouche P,Péronneau P

    更新日期:1990-01-01 00:00:00

  • Low-back loading in lifting two loads beside the body compared to lifting one load in front of the body.

    abstract::Low-back load during manual lifting is considered an important risk factor for the occurrence of low-back pain. Splitting a load, so it can be lifted beside the body (one load in each hand), instead of in front of the body, can be expected to reduce low-back load. Twelve healthy young men lifted 10 and 20-kg wide and ...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2008.10.013

    authors: Faber GS,Kingma I,Bakker AJ,van Dieën JH

    更新日期:2009-01-05 00:00:00

  • Suitability of Kinect for measuring whole body movement patterns during exergaming.

    abstract::Exergames provide a challenging opportunity for home-based training and evaluation of postural control in the elderly population, but affordable sensor technology and algorithms for assessment of whole body movement patterns in the home environment are yet to be developed. The aim of the present study was to evaluate ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.07.017

    authors: van Diest M,Stegenga J,Wörtche HJ,Postema K,Verkerke GJ,Lamoth CJ

    更新日期:2014-09-22 00:00:00

  • Fibroblast responses to cyclic mechanical stretching depend on cell orientation to the stretching direction.

    abstract::Fibroblasts in intact tendons align with stretching direction, but they tend to orient randomly in healing tendons. Therefore, a question arises: Do fibroblast responses to mechanical stretching depend on their orientation? To address this question, human patellar tendon fibroblasts were grown in custom-made silicone ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.09.011

    authors: Wang JH,Yang G,Li Z,Shen W

    更新日期:2004-04-01 00:00:00

  • Uncertainty quantification of wall shear stress in intracranial aneurysms using a data-driven statistical model of systemic blood flow variability.

    abstract::Adverse wall shear stress (WSS) patterns are known to play a key role in the localisation, formation, and progression of intracranial aneurysms (IAs). Complex region-specific and time-varying aneurysmal WSS patterns depend both on vascular morphology as well as on variable systemic flow conditions. Computational fluid...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.10.005

    authors: Sarrami-Foroushani A,Lassila T,Gooya A,Geers AJ,Frangi AF

    更新日期:2016-12-08 00:00:00

  • Altered osteogenic commitment of human mesenchymal stem cells by ERM protein-dependent modulation of cellular biomechanics.

    abstract::Cellular mechanics is known to play an important role in many cellular functions including adhesion, migration, proliferation, and differentiation. Human mesenchymal stem cells (hMSCs) demonstrate unique mechanical properties distinct from fully differentiated cells. This observation suggests that the stem cell mechan...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.07.024

    authors: Titushkin I,Cho M

    更新日期:2011-10-13 00:00:00

  • A wax barrier to simulate bone resorption for pre-clinical laboratory models of cemented total hip replacements.

    abstract::Pre-clinical tests are often performed to screen new implant designs, surgical techniques, and cement formulations. In this work, we developed a technique to simulate the cement-bone morphology found with postmortem retrieved cemented hip replacements. With this technique, a soy wax barrier is created along the endost...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.06.029

    authors: Cherukuri AR,Miller MA,Race A,Izant TH,Mann KA

    更新日期:2010-10-19 00:00:00

  • The role of muscles in joint degeneration and osteoarthritis.

    abstract::The purpose of this work was to establish a controlled and reversible muscle weakness model for studying the effects of weakness on joint degeneration leading to osteoarthritis (OA). The knee extensor muscles of rabbits were injected with single or repeat doses of Botulinum type-A toxin (BTX-A) to partially inhibit ac...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.03.001

    authors: Herzog W,Longino D

    更新日期:2007-01-01 00:00:00

  • Does the activity of ankle plantar flexors differ between limbs while healthy, young subjects stand at ease?

    abstract::Inferences on the active contribution of plantar flexors to the stabilisation of human standing posture have been drawn from surface electromyograms (EMGs). Surface EMGs were however often detected unilaterally, presuming the myoelectric activity from muscles in a single leg reflects the pattern of muscle activation i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.09.018

    authors: Dos Anjos FV,Gazzoni M,Vieira TM

    更新日期:2018-11-16 00:00:00

  • The effect of surface area digitizations on the prediction of spherical anatomical geometries for computer-assisted applications.

    abstract::Intraoperative digitization of osseous structures is an integral component of computer-assisted orthopaedic surgery. This study determined the repeatability and accuracy of predicting known radii and center locations of spherical objects for different proportions of digitized surface areas and various sphere sizes. Al...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.01.018

    authors: Whitney KD,Ferreira LM,King GJ,Johnson JA

    更新日期:2009-05-29 00:00:00

  • Volume effects on fatigue life of equine cortical bone.

    abstract::Materials, including bone, often fail due to loading in the presence of critical flaws. The relative amount, location, and interaction of these flaws within a stressed volume of material play a role in determining the failure properties of the structure. As materials are generally imperfect, larger volumes of material...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.05.025

    authors: Bigley RF,Gibeling JC,Stover SM,Hazelwood SJ,Fyhrie DP,Martin RB

    更新日期:2007-01-01 00:00:00

  • Quantification of red blood cell deformation at high-hematocrit blood flow in microvessels.

    abstract::The deformation of red blood cells in microvessels was investigated numerically for various vessel diameters, hematocrits, and shear rates. We simulated blood flow in circular channels with diameters ranging from 9 to 50 μm, hematocrits from 20% to 45%, and shear rates from 20 to 150 s(-1) using a particle-based model...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.08.026

    authors: Alizadehrad D,Imai Y,Nakaaki K,Ishikawa T,Yamaguchi T

    更新日期:2012-10-11 00:00:00

  • Sticky chain model for shear response of red blood cells.

    abstract::A sticky chain model has been proposed to describe the unfolding of spectrin network under applied mechanical loads. With the model, the response of a red blood cell (RBC) under static and cyclic shear loading has been predicted, which agrees qualitatively with relevant experimental results. ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.05.028

    authors: Huang GY,Mai YW

    更新日期:2008-08-07 00:00:00

  • Application of a mechanobiological simulation technique to stents used clinically.

    abstract::Many cardiovascular diseases are characterised by the restriction of blood flow through arteries. Stents can be expanded within arteries to remove such restrictions; however, tissue in-growth into the stent can lead to restenosis. In order to predict the long-term efficacy of stenting, a mechanobiological model of the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.12.014

    authors: Boyle CJ,Lennon AB,Prendergast PJ

    更新日期:2013-03-15 00:00:00

  • Non-interacting modes for stress, strain and energy in anisotropic hard tissue.

    abstract::The six non-interacting modes for stress, strain and energy in an orthotropic elastic model of human femoral cortical bone tissue are discussed and illustrated. The stress and strain modes are illustrated using the representation of the stress and strain fields around a circular hole in a flat plate of cortical bone s...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90311-a

    authors: Cowin SC,Sadegh AM

    更新日期:1991-01-01 00:00:00

  • In vivo kinematics and articular surface congruency of total ankle arthroplasty during gait.

    abstract::Relatively high rates of loosening and implant failure have been reported after total ankle arthroplasty. Abnormal kinematics and incongruency of the articular surface may cause increased contact pressure and rotational torque applied to the implant, leading to loosening and implant failure. We measured in vivo kinema...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.05.043

    authors: Yamaguchi S,Tanaka Y,Banks S,Kosugi S,Sasho T,Takahashi K,Takakura Y

    更新日期:2012-08-09 00:00:00

  • Non-linear viscoelastic models predict fingertip pulp force-displacement characteristics during voluntary tapping.

    abstract::We evaluated whether lumped-parameter non-linear viscoelastic models of human fingertip tissue can describe fingertip force-displacement characteristics during a range of rapid, dynamic tapping tasks. Eight human subjects tapped with their index finger on the surface of a rigid load cell while an optical system tracke...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/s0021-9290(02)00438-4

    authors: Jindrich DL,Zhou Y,Becker T,Dennerlein JT

    更新日期:2003-04-01 00:00:00

  • Model of muscle-tendon interaction during frog semitendinosis fixed-end contractions.

    abstract::A structural model was developed to explain sarcomere shortening at the expense of tendon lengthening in the frog semitendinosis (ST) muscle-tendon system. The model was based on the data of Lieber et al. [Am. J. Physiol. 261, C86-C92 (1991)], who determined the relationship between the sarcomere length, tendon load (...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90261-x

    authors: Lieber RL,Brown CG,Trestik CL

    更新日期:1992-04-01 00:00:00

  • Toward quantification of athetotic movements by frequency spectrum analysis.

    abstract::The frequency spectrum of the elbow movements of one normal subject and six handicapped subjects were obtained in order to investigate the possibility of using this technique in quantifying athetosis. The frequency spectrum technique appears to be useful but data from more subjects must be obtained and specific detail...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(85)90046-6

    authors: Niku S,Henderson JM

    更新日期:1985-01-01 00:00:00

  • The fixion proximal femur nailing system: biomechanical properties of the nail and a cadaveric study.

    abstract::The treatment of choice for early mobilization of hip fracture is surgery, which traditionally employs side plates and screws or intramedullary nails. We examined the biomechanical properties of a new proximal femoral nail system. The new expandable Fixion proximal femur nailing (PFN) system, made of stainless-steel a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.03.014

    authors: Steinberg EL,Blumberg N,Dekel S

    更新日期:2005-01-01 00:00:00

  • The active and passive ciliary motion in the embryo node: a computational fluid dynamics model.

    abstract::The breaking of left-right symmetry in the mammalian embryo is believed to occur in a transient embryonic structure, the node, when cilia create a leftward flow of liquid. The two-cilia hypothesis proposes that the node contains two kinds of primary cilia: motile cilia that rotate autonomously to generate the leftward...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.10.040

    authors: Chen D,Norris D,Ventikos Y

    更新日期:2009-02-09 00:00:00

  • Morphologic adaptation of arterial endothelial cells to longitudinal stretch in organ culture.

    abstract::Arteries in vivo are subjected to large longitudinal stretch, which changes significantly due to vascular disease and surgery. However, little is known about the effect of longitudinal stretch on arterial endothelium. The aim of this study was to determine the morphologic adaptation of arterial endothelial cells (ECs)...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.08.016

    authors: Lee YU,Drury-Stewart D,Vito RP,Han HC

    更新日期:2008-11-14 00:00:00

  • Comparison of acoustic characteristics predicted by Biot's theory and the modified Biot-Attenborough model in cancellous bone.

    abstract::Biot's theory and the modified Biot-Attenborough (MBA) model are applied to predict the dependences of acoustic characteristics on frequency and on porosity in cancellous bone. The phase velocities and the attenuation coefficients predicted by both theories are compared with the experimental data of bovine cancellous ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.12.004

    authors: Lee KI,Yoon SW

    更新日期:2006-01-01 00:00:00

  • Relationship between streaming potential and compressive stress in bovine intervertebral tissue.

    abstract::The intervertebral disc is formed by the nucleus pulposus (NP) and annulus fibrosus (AF), and intervertebral tissue contains a large amount of negatively charged proteoglycan. When this tissue becomes deformed, a streaming potential is induced by liquid flow with positive ions. The anisotropic property of the AF tissu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.06.018

    authors: Fujisaki K,Tadano S,Asano N

    更新日期:2011-09-02 00:00:00

  • Development of an RSA calibration system with improved accuracy and precision.

    abstract::In this study, a new radiostereometric analysis (RSA) calibration cage was developed with the aim of improving the accuracy and precision of RSA. This development consisted of three steps: a numerical simulation technique was first used to design the new cage; a synthetic imaging method was then implemented to predict...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.11.012

    authors: Cai R,Yuan X,Rorabeck C,Bourne RB,Holdsworth DW

    更新日期:2008-01-01 00:00:00

  • Mechanical heterogeneities in the subendothelial matrix develop with age and decrease with exercise.

    abstract::Arterial stiffening occurs with age and is associated with lack of exercise. Notably both age and lack of exercise are major cardiovascular risk factors. While it is well established that bulk arterial stiffness increases with age, more recent data suggest that the intima, the innermost arterial layer, also stiffens d...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.016

    authors: Kohn JC,Chen A,Cheng S,Kowal DR,King MR,Reinhart-King CA

    更新日期:2016-06-14 00:00:00

  • Mechanical behavior of coronary stents investigated through the finite element method.

    abstract::Intravascular stents are small tube-like structures expanded into stenotic arteries to restore blood flow perfusion to the downstream tissues. The stent is mounted on a balloon catheter and delivered to the site of blockage. When the balloon is inflated, the stent expands and is pressed against the inner wall of the c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00033-7

    authors: Migliavacca F,Petrini L,Colombo M,Auricchio F,Pietrabissa R