Model of muscle-tendon interaction during frog semitendinosis fixed-end contractions.

Abstract:

:A structural model was developed to explain sarcomere shortening at the expense of tendon lengthening in the frog semitendinosis (ST) muscle-tendon system. The model was based on the data of Lieber et al. [Am. J. Physiol. 261, C86-C92 (1991)], who determined the relationship between the sarcomere length, tendon load (as a fraction of maximum isometric tension) and tendon, bone-tendon junction (BTJ), and aponeurosis strain. The model was generated assuming a finite time-course of cross-bridge attachment [Huxley, Prog. Biophys. 7,255-318 (1957)], an ideal sarcomere length-tension relationship [Gordon et al., J. Physiol. 184, 170-192 (1966)] and an ideal force-velocity relationship [Katz, J. Physiol. 96, 45-64 (1939); Edman, J. Physiol. 291, 143-159 (1979)]. Functionally, sarcomeres operated on three distinct regions of the length-tension curve: (1) regions where the muscle force decreased as sarcomeres shortened (the shallow and steep ascending limbs); (2) regions where the muscle force increased as sarcomeres shortened and there was little passive tension (descending limb, where sarcomere length greater than or equal to 3.0 microns); and (3) regions where the muscle force increased as sarcomeres shortened and there was a significant passive tension (descending limb where sarcomere length greater than 3.0 microns). Using such a physiological model, it was found that the effect of tendon compliance was to 'skew' the sarcomere length-tension curve to the right and to increase the operating range of the muscle-tendon unit.(ABSTRACT TRUNCATED AT 250 WORDS)

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Lieber RL,Brown CG,Trestik CL

doi

10.1016/0021-9290(92)90261-x

keywords:

subject

Has Abstract

pub_date

1992-04-01 00:00:00

pages

421-8

issue

4

eissn

0021-9290

issn

1873-2380

pii

0021-9290(92)90261-X

journal_volume

25

pub_type

杂志文章
  • Computer simulation of blood flow in the human arm.

    abstract::This paper considers a finite element method to characterize blood flow in the human arm arteries. A set of different pressure waveforms, which represent normal and diseased heart pulses, is used for the proximal boundary conditions, and a modified Windkessel model is used for the distal arterial boundary conditions. ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90019-5

    authors: Balar SD,Rogge TR,Young DF

    更新日期:1989-01-01 00:00:00

  • Hemodynamic insight into overlapping bare-metal stents strategy in the treatment of aortic aneurysm.

    abstract::Clinical trials have shown overlapping bare-metal stents provoke effective thrombus clot within the aneurysm sac and shrinkage of the aneurysm by directly regulating the hemodynamics. To gain insight into the hemodynamic mechanism of the technique, three cases of simplified thoracic aortic aneurysm models (with no ste...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.03.028

    authors: Zhang P,Liu X,Sun A,Fan Y,Deng X

    更新日期:2015-07-16 00:00:00

  • Failure of mineralized collagen fibrils: modeling the role of collagen cross-linking.

    abstract::Experimental evidence demonstrates that collagen cross-linking in bone tissue significantly influences its deformation and failure behavior yet difficulties exist in determining the independent biomechanical effects of collagen cross-linking using in vitro and in vivo experiments. The aim of this study is to use a nan...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.02.017

    authors: Siegmund T,Allen MR,Burr DB

    更新日期:2008-01-01 00:00:00

  • Maximum isometric arm forces in the horizontal plane.

    abstract::In this paper, we measured the maximum isometric force at the hand in eight directions in the horizontal plane and at five positions in the workplace. These endpoint forces were the result of shoulder horizontal adduction/abduction and elbow flexion/extension torques. We found that the normalized maximum forces of all...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2005.01.004

    authors: Jan Nijhof E,Gabriel DA

    更新日期:2006-01-01 00:00:00

  • Tensile stress-strain characteristics of the human meniscal material.

    abstract::The nonlinear stress-strain characteristics of the human menisci were determined by uniaxial elongation tests performed on circumferential and radial specimens prepared from different regions, layers, and locations. The properties of the collagen fibers and the matrix were calculated using the test results along with ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)00081-e

    authors: Tissakht M,Ahmed AM

    更新日期:1995-04-01 00:00:00

  • Physical properties of resistance vessel wall in peripheral blood flow regulation--I. Mathematical model.

    abstract::A mathematical model is introduced to investigate the influence of the physical properties of the resistance vessel wall on the metabolic and myogenic mechanisms. The resistance vessel wall is assumed to have an elastic property and the elastic modulus to be a function of pressure (myogenic) and flow (metabolic). Bloo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90033-x

    authors: Iida N

    更新日期:1989-01-01 00:00:00

  • Factors influencing performance in the Hecht vault and implications for modelling.

    abstract::This paper investigated the factors that influence Hecht vault performance and assessed the level of model complexity required to give an adequate representation of vaulting. A five-segment planar simulation model with a visco-elastic shoulder joint and a torque generator at the shoulder joint was used to simulate the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.02.039

    authors: King MA,Yeadon MR

    更新日期:2005-01-01 00:00:00

  • Finite element modeling reveals complex strain mechanics in the aponeuroses of contracting skeletal muscle.

    abstract::A finite element model was used to investigate the counter-intuitive experimental observation that some regions of the aponeuroses of a loaded and contracting muscle may shorten rather than undergo an expected lengthening. The model confirms the experimental findings and suggests that pennation angle plays a significa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.01.005

    authors: Chi SW,Hodgson J,Chen JS,Reggie Edgerton V,Shin DD,Roiz RA,Sinha S

    更新日期:2010-05-07 00:00:00

  • Hip extension, knee flexion paradox: a new mechanism for non-contact ACL injury.

    abstract::Considering that an athlete performs at-risk sports activities countless times throughout the course of his or her career prior to the instance of anterior cruciate ligament (ACL) injury, one may conclude that non-contact ACL injury is a rare event. Nevertheless, the overall number of non-contact ACL injuries, both in...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.11.013

    authors: Hashemi J,Breighner R,Chandrashekar N,Hardy DM,Chaudhari AM,Shultz SJ,Slauterbeck JR,Beynnon BD

    更新日期:2011-02-24 00:00:00

  • Non-invasive prediction of skin flap shrinkage: a new concept based on animal experimental evidence.

    abstract::A non-invasive, in vivo method has been developed to predict the skin flap shrinkage (retraction) following a harvest. It involves the use of a novel custom-designed extensometer to measure the force-displacement behaviour of skin and subsequent data analysis to estimate the shrinkage. In validation experiments perfor...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.03.012

    authors: Lim KH,Jeyapalina S,Ho HN,Chew CM,Chen PC,Teo CL,Lim BH

    更新日期:2008-01-01 00:00:00

  • Effects of short-term recovery periods on fluid-induced signaling in osteoblastic cells.

    abstract::It is well known that cyclic mechanical loading can produce an anabolic response in bone. In vivo studies have shown that the insertion of short-term recovery periods (10-15 s) into mechanical loading profiles led to an increased osteogenic response compared to continuous cyclic loading of bone. Although this is sugge...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.08.009

    authors: Batra NN,Li YJ,Yellowley CE,You L,Malone AM,Kim CH,Jacobs CR

    更新日期:2005-09-01 00:00:00

  • Evaluation of brain-skull interface modelling approaches on the prediction of acute subdural hematoma in the elderly.

    abstract::Acute subdural hematoma (ASDH) in the elderly is currently a matter of concern due to the growing number of the aging population and their higher incident rate compared to the younger adults. Computational head models that can replicate this age-related injury pattern are valuable tools to help addressing this concern...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109787

    authors: Zhou Z,Li X,Kleiven S

    更新日期:2020-05-22 00:00:00

  • Contribution of the skin, rectus abdominis and their sheaths to the structural response of the abdominal wall ex vivo.

    abstract::A better understanding of the abdominal wall biomechanics could help designing new treatments for incisional hernia. In the current study, an experimental protocol was developed to evaluate the contributions of the abdominal wall components to the structural response of the anterior part of the abdominal wall. The spe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.06.031

    authors: Tran D,Mitton D,Voirin D,Turquier F,Beillas P

    更新日期:2014-09-22 00:00:00

  • Mechanical adaptions of collective cells nearby free tissue boundaries.

    abstract::Mechanical adaptions of cells, including stiffness variation, cytoskeleton remodeling, motion coordination, and shape changing, are essential for tissue morphogenesis, wound healing, and malignant progression. In this paper, we take confluent monolayers of Madin-Darby canine kidney (MDCK) and mouse myoblast (C2C12) ce...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109763

    authors: Lv JQ,Chen PC,Góźdź WT,Li B

    更新日期:2020-05-07 00:00:00

  • Investigation of the kinetics of anaerobic metabolism by analysis of the performance of elite sprinters.

    abstract::The principal motivation for the present work was the study of the kinetics of anaerobic metabolism. A new mathematical model of the bioenergetics of sprinting, incorporating a three-equation representation of anaerobic metabolism, is developed. Results computed using the model are compared with measured data from the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00035-x

    authors: Ward-Smith AJ,Radford PF

    更新日期:2000-08-01 00:00:00

  • Comparison of micro-level and continuum-level voxel models of the proximal femur.

    abstract::Continuum-level finite element (FE) models became standard computational tools for the evaluation of bone mechanical behavior from in vivo computed tomography scans. Such scans do not account for the anisotropy of the bone. Instead, local mechanical properties in the continuum-level FE models are assumed isotropic and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.10.027

    authors: Verhulp E,van Rietbergen B,Huiskes R

    更新日期:2006-01-01 00:00:00

  • The influence of ligament modelling strategies on the predictive capability of finite element models of the human knee joint.

    abstract::In finite element (FE) models knee ligaments can represented either by a group of one-dimensional springs, or by three-dimensional continuum elements based on segmentations. Continuum models closer approximate the anatomy, and facilitate ligament wrapping, while spring models are computationally less expensive. The me...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.08.030

    authors: Naghibi Beidokhti H,Janssen D,van de Groes S,Hazrati J,Van den Boogaard T,Verdonschot N

    更新日期:2017-12-08 00:00:00

  • A mathematical high bar-human body model for analysing and interpreting mechanical-energetic processes on the high bar.

    abstract::The aims of this study were: 1. To study the transfer of energy between the high bar and the gymnast. 2. To develop criteria from the utilisation of high bar elasticity and the utilisation of muscle capacity to assess the effectiveness of a movement solution. 3. To study the influence of varying segment movement upon ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00134-1

    authors: Arampatzis A,Brüggemann GP

    更新日期:1998-12-01 00:00:00

  • Determination of biomechanical characteristics of restrictive adhesions and of functional impairment after flexor tendon surgery: a methodological study of rabbits.

    abstract::Formation of restrictive adhesions is one of the main obstacles in rehabilitation following hand surgery. Most experimental work, however, involves only a macroscopic and/or histologic evaluation of the amount of adhesions, and their functional characteristics are poorly described. The aim of this study was to develop...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90171-i

    authors: Hagberg L,Wik O,Gerdin B

    更新日期:1991-01-01 00:00:00

  • Modeling movement disorders--CRPS-related dystonia explained by abnormal proprioceptive reflexes.

    abstract::Humans control their movements using adaptive proprioceptive feedback from muscle afferents. The interaction between proprioceptive reflexes and biomechanical properties of the limb is essential in understanding the etiology of movement disorders. A non-linear neuromuscular model of the wrist incorporating muscle dyna...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.09.024

    authors: Mugge W,Munts AG,Schouten AC,van der Helm FC

    更新日期:2012-01-03 00:00:00

  • Reliability of medial-longitudinal-arch measures for skin-markers based kinematic analysis.

    abstract::The medial-longitudinal arch (MLA) is perhaps the most important feature characterizing foot morphology. While current skin-markers based models of the MLA angle used in stereophotogrammetry allow to estimate foot arch shape and deformation, these do not always appear consistent with foot anatomy and with standard cli...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.03.017

    authors: Caravaggi P,Matias AB,Taddei UT,Ortolani M,Leardini A,Sacco ICN

    更新日期:2019-05-09 00:00:00

  • Instantaneous velocity estimation for the four swimming strokes using a 3-axis accelerometer: Validation on paralympic athletes.

    abstract::Inertial measurement unit systems (IMU) are increasingly used in sports. However, no algorithm evaluating the instantaneous swimming velocity has been validated on the four swimming strokes, or on dive start. Our objective is to develop and validate a new method to measure instantaneous swimming velocity on athletes p...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2021.110261

    authors: Clément J,Charbonneau M,Thompson M

    更新日期:2021-01-19 00:00:00

  • Simulation of mechanical behavior of temperature-responsive braided stents made of shape memory polyurethanes.

    abstract::Polymeric stents can be considered as an alternative to metallic stents thanks to their lessened incidence of restenosis and controlled deployment. The purpose of this study was to investigate the feasibility of developing a temperature-responsive braided stent using shape memory polyurethane (SMPU) through finite ele...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.032

    authors: Kim JH,Kang TJ,Yu WR

    更新日期:2010-03-03 00:00:00

  • Modeling of hemodynamics arising from malaria infection.

    abstract::We propose a numerical model of hemodynamics arising from malaria infection. This model is based on a particle method, where all the components of blood are represented by the finite number of particles. A two-dimensional spring network of membrane particles is employed for expressing the deformation of malaria infect...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.01.011

    authors: Imai Y,Kondo H,Ishikawa T,Teck Lim C,Yamaguchi T

    更新日期:2010-05-07 00:00:00

  • A wax barrier to simulate bone resorption for pre-clinical laboratory models of cemented total hip replacements.

    abstract::Pre-clinical tests are often performed to screen new implant designs, surgical techniques, and cement formulations. In this work, we developed a technique to simulate the cement-bone morphology found with postmortem retrieved cemented hip replacements. With this technique, a soy wax barrier is created along the endost...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.06.029

    authors: Cherukuri AR,Miller MA,Race A,Izant TH,Mann KA

    更新日期:2010-10-19 00:00:00

  • Biomechanical response to mediolateral foot-placement perturbations during walking.

    abstract::Dynamic balance in the frontal plane requires active control, which is accomplished largely through control of mediolateral foot placement. Individuals without mobility impairments have the ability to compensate for variability in foot-placement to maintain their balance; however, it is unknown how individuals respond...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110213

    authors: Brough LG,Klute GK,Neptune RR

    更新日期:2020-12-28 00:00:00

  • Effect of cracks on the local deformations of articular cartilage.

    abstract::Despite significant evidence regarding the increased risk of cartilage degeneration due to traumatic injuries to joints, there is still a lack of understanding of the mechanisms underlying osteoarthritis development following a joint injury. Injuries in knee cartilage are often characterized by lesions or tears. In ad...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109970

    authors: Komeili A,Luqman S,Federico S,Herzog W

    更新日期:2020-09-18 00:00:00

  • An expression relating breaking stress and density of trabecular bone.

    abstract::Bone mineral density (BMD) is the principal diagnostic tool used in clinical settings to diagnose and monitor osteoporosis. Experimental studies on ex vivo bone samples from multiple skeletal locations have been used to propose that their breaking stress bears a power-law relationship to volumetric BMD, with a locatio...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.12.001

    authors: Rajapakse CS,Thomsen JS,Espinoza Ortiz JS,Wimalawansa SJ,Ebbesen EN,Mosekilde L,Gunaratne GH

    更新日期:2004-08-01 00:00:00

  • Accuracy of a video strain measurement system.

    abstract::The purpose of this study was to determine the accuracy of a video system which our laboratory has been using to measure soft tissue strain. Both static and dynamic error analyses were performed to assess the accuracy of our video system. Static error was defined as the amount of movement reported by the video system ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00131-x

    authors: Smutz WP,Drexler M,Berglund LJ,Growney E,An KN

    更新日期:1996-06-01 00:00:00

  • Preload substantially influences the intervertebral disc stiffness in loading-unloading cycles of compression.

    abstract::Disc hydration is controlled by fluid imbibition and exudation and hence by applied load magnitude and history, internal osmotic pressure and disc conditions. It affects both the internal load distribution and external load-bearing of a disc while variations therein give rise to the disc time-dependent characteristics...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.05.006

    authors: Schmidt H,Shirazi-Adl A,Schilling C,Dreischarf M

    更新日期:2016-06-14 00:00:00