Preload substantially influences the intervertebral disc stiffness in loading-unloading cycles of compression.

Abstract:

:Disc hydration is controlled by fluid imbibition and exudation and hence by applied load magnitude and history, internal osmotic pressure and disc conditions. It affects both the internal load distribution and external load-bearing of a disc while variations therein give rise to the disc time-dependent characteristics. This study aimed to evaluate the effect of changes in compression preload magnitude on the disc axial cyclic compression stiffness under physiological loading. After 20h of free hydration, effects of various preload magnitudes (no preload, 0.06 and 0.28MPa, applied for eight hours) and disc-bone preparation conditions on disc height and axial stiffness were investigated using 36 disc-bone and 24 isolated disc (without bony endplates) bovine specimens. After preloading, specimens were subjected to ten loading/unloading cycles each of 7.5min compression at 0.5MPa followed by 7.5min at 0.06MPa. Under 0.06MPa preload, the specimen height losses during high loading periods of cyclic loading were greater than corresponding height recoveries during low loading phases. This resulted in a progressive reduction in the specimen height and increase in its stiffness. Differences between disc height losses in high cyclic loads and between stiffness in both load increase and release phases were significant for 0 and 0.06MPa vs. 0.28MPa preload. Results highlight the significant role of disc preload magnitude/history and hence disc height and hydration on disc stiffness in loading/unloading and disc height loss in loading periods. Proper preconditioning and hence hydration level should be achieved if recovery in height loss similar to in vivo conditions is expected.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Schmidt H,Shirazi-Adl A,Schilling C,Dreischarf M

doi

10.1016/j.jbiomech.2016.05.006

subject

Has Abstract

pub_date

2016-06-14 00:00:00

pages

1926-1932

issue

9

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(16)30565-6

journal_volume

49

pub_type

杂志文章
  • Simulating contact using the elastic foundation algorithm in OpenSim.

    abstract::Modeling joint contact in OpenSim is not well understood. This study systematically investigated the variables associated with the elastic foundation contact model within OpenSim by performing a series of controlled benchtop experiment and concomitant simulations. Four metal-on-plastic interactions were modeled, inclu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.11.025

    authors: Hast MW,Hanson BG,Baxter JR

    更新日期:2019-01-03 00:00:00

  • Microcrack growth parameters for compact bone deduced from stiffness variations.

    abstract::This paper shows how information on the fatigue behaviour of microcracks can be obtained by the analysis of stiffness changes measured during cyclic loading. Relationships between crack length, growth rate and cyclic stress intensity were deduced, and compared with previous empirical equations. Results show that the c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00050-5

    authors: Taylor D

    更新日期:1998-07-01 00:00:00

  • The consequences of dehydration-hydration on bone anisotropy and implications on the sublamellar organization of mineralized collagen fibrils.

    abstract::In this study, the effect of dehydration-hydration based sublamellar dimensional change on bone anisotropy was used as a tool to understand sublamellar organization of mineralized collagen fibrils. Bone consists of hydroxyapatite, Type I Collagen, mucopolysaccharides and bone fluid, which associates with bone constitu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109737

    authors: Utku FS

    更新日期:2020-05-07 00:00:00

  • Greater toe grip and gentler heel strike are the strategies to adapt to slippery surface.

    abstract::This study investigated the plantar pressure distribution during gait on wooden surface with different slipperiness in the presence of contaminants. Fifteen Chinese males performed 10 walking trials on a 5-m wooden walkway wearing cloth shoe in four contaminated conditions (dry, sand, water, oil). A pressure insole sy...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.11.001

    authors: Fong DT,Mao DW,Li JX,Hong Y

    更新日期:2008-01-01 00:00:00

  • On the permanent hip-stabilizing effect of atmospheric pressure.

    abstract::Hip joint dislocations related to total hip arthroplasty (THA) are a common complication especially in the early postoperative course. The surgical approach, the alignment of the prosthetic components, the range of motion and the muscle tone are known factors influencing the risk of dislocation. A further factor that ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.05.013

    authors: Prietzel T,Hammer N,Schleifenbaum S,Kaßebaum E,Farag M,von Salis-Soglio G

    更新日期:2014-08-22 00:00:00

  • Body weight support impacts lateral stability during treadmill walking.

    abstract::Body weight support (BWS) systems are a common tool used in gait rehabilitation. BWS systems may alter the requirements for an individual to actively stabilize by 1) providing lateral restoring forces that reduce the requirements for the nervous system to actively stabilize and 2) decreasing the stabilizing gravitatio...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.05.026

    authors: Dragunas AC,Gordon KE

    更新日期:2016-09-06 00:00:00

  • The between-day reliability of peroneus longus EMG during walking.

    abstract::The peroneus longus (PL) is a rearfoot evertor, important in frontal plane foot motion. Studying PL function has been limited by previous electromyography (EMG) studies reporting poor between-day reliability. Due to its close proximity to adjacent muscles, EMG measures of PL may be susceptible to crosstalk, thus corre...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.01.037

    authors: Reeves J,Jones R,Liu A,Bent L,Nester C

    更新日期:2019-03-27 00:00:00

  • Higher critical plaque wall stress in patients who died of coronary artery disease compared with those who died of other causes: a 3D FSI study based on ex vivo MRI of coronary plaques.

    abstract::Mechanical forces play an important role in the rupture of vulnerable plaques. This process is often associated with cardiovascular syndromes, such as heart attack and stroke. In this study, magnetic resonance imaging (MRI)-based models were used to investigate the association between plaque wall stress (PWS) and coro...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.11.007

    authors: Huang X,Yang C,Zheng J,Bach R,Muccigrosso D,Woodard PK,Tang D

    更新日期:2014-01-22 00:00:00

  • Turbulence model choice for the calculation of drag forces when using the CFD method.

    abstract::The aim of this work is to specify which model of turbulence is the most adapted in order to predict the drag forces that a swimmer encounters during his movement in the fluid environment. For this, a Computational Fluid Dynamics (CFD) analysis has been undertaken with a commercial CFD code (Fluent). The problem was m...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.010

    authors: Zaïdi H,Fohanno S,Taïar R,Polidori G

    更新日期:2010-02-10 00:00:00

  • Micro-computed tomography assisted distal femur metaphyseal blunt punch compression for determining trabecular bone strength in mice.

    abstract::Shorter generation time and the power of genetic manipulation make mice an ideal model system to study bone biology as well as bone diseases. However their small size presents a challenge to perform strength measurements, particularly of the weight-bearing cancellous bone in the murine long bones. We recently develope...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.02.040

    authors: Sankar U,Pritchard ZJ,Voor MJ

    更新日期:2016-05-03 00:00:00

  • Influence of curvature dynamics on pulsatile coronary artery flow in a realistic bifurcation model.

    abstract::The coronary arteries undergo large dynamic variations during each cardiac cycle due to their position on the beating heart. The local artery curvature varies significantly. In this study the influence of dynamic curvature on coronary artery hemodynamics is analyzed numerically. A realistic model of the bifurcation of...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.01.021

    authors: Prosi M,Perktold K,Ding Z,Friedman MH

    更新日期:2004-11-01 00:00:00

  • Shoe midsole hardness, sex and age effects on lower extremity kinematics during running.

    abstract::Previous studies investigating the effects of shoe midsole hardness on running kinematics have often used male subjects from within a narrow age range. It is unknown whether shoe midsole hardness has the same kinematic effect on male and female runners as well as runners from different age categories. As sex and age h...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.03.027

    authors: Nigg BM,Baltich J,Maurer C,Federolf P

    更新日期:2012-06-01 00:00:00

  • Instantaneous velocity estimation for the four swimming strokes using a 3-axis accelerometer: Validation on paralympic athletes.

    abstract::Inertial measurement unit systems (IMU) are increasingly used in sports. However, no algorithm evaluating the instantaneous swimming velocity has been validated on the four swimming strokes, or on dive start. Our objective is to develop and validate a new method to measure instantaneous swimming velocity on athletes p...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2021.110261

    authors: Clément J,Charbonneau M,Thompson M

    更新日期:2021-01-19 00:00:00

  • Sarcomere dynamics in skeletal muscle myofibrils during isometric contractions.

    abstract::The main goal of this study was to evaluate the dynamics of sarcomeres during isometric activation of skeletal muscle myofibrils. Rabbit psoas myofibrils (n=14) were attached between a pair of cantilevers for force measurements at one side and a rigid glass needle at the other side, and their images were used for meas...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.08.011

    authors: Pavlov I,Novinger R,Rassier DE

    更新日期:2009-12-11 00:00:00

  • Trunk stiffness and dynamics during active extension exertions.

    abstract::Spinal stability is related to the recruitment and control of active muscle stiffness. Stochastic system identification techniques were used to calculate the effective stiffness and dynamics of the trunk during active trunk extension exertions. Twenty-one healthy adult subjects (10 males, 11 females) wore a harness wi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.09.014

    authors: Moorhouse KM,Granata KP

    更新日期:2005-10-01 00:00:00

  • An application of beam theory to determine the stress and deformation of long bones.

    abstract::We present a generalized beam theory in which deformation and load are determined simultaneously, in order to analyze statically indeterminant problems involving long bones. We regard a long bone as a beam curved in three dimensions for which the cross-sectional properties vary continuously along its length. The theor...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90087-0

    authors: Salathe EP Jr,Arangio GA,Salathe EP

    更新日期:1989-01-01 00:00:00

  • Ex-vivo observation of calcification process in chick tibia slice: Augmented calcification along collagen fiber orientation in specimens subjected to static stretch.

    abstract::Bone formation through matrix synthesis and calcification in response to mechanical loading is an essential process of the maturation in immature animals, although how mechanical loading applied to the tissue increases the calcification and improves mechanical properties, and which directions the calcification progres...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.07.024

    authors: Maeda E,Ichikawa K,Murase K,Nagayama K,Matsumoto T

    更新日期:2018-09-10 00:00:00

  • The Cybermouse: a simple method of describing the trajectory of the human mandible in three dimensions.

    abstract::A simple method of recording the three-dimensional movements of the mandible together with up to 10 channels of other physiological data is described. The system is based on a commercially available device, the Cybermouse (IPC, Freemont, CA, U.S.A.), consisting of a lightweight ultrasonic emitter which can be attached...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00012-2

    authors: Prinz JF

    更新日期:1997-06-01 00:00:00

  • In vivo muscular force analysis during the isometric flexion on a monkey's elbow.

    abstract::An experimental method has been developed to analyse muscular forces and torques in vivo during isometric flexion of the elbow in small monkeys (Macaca fascicularis). A mini-transducer was built with a view to measure forces in situ, without cutting tendons. The positions of tendon insertions were measured on anatomic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90220-5

    authors: Landjerit B,Maton B,Peres G

    更新日期:1988-01-01 00:00:00

  • In-vitro results of rapid maxillary expansion on adults compared with finite element simulations.

    abstract::This study was mainly performed to investigate the effects of high maxillary expansion forces on the skull with fresh and thiel-fixed human skulls. The maxillary suture was not weakened except in one experiment. This study compares the strain measured on the zygomatic process of the skull with the results of a finite ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.02.002

    authors: Boryor A,Hohmann A,Wunderlich A,Geiger M,Kilic F,Sander M,Sander C,Böckers T,Günter Sander F

    更新日期:2010-05-07 00:00:00

  • Calf muscle moment, work and efficiency in level walking; role of series elasticity.

    abstract::Moment and work of the human calf muscles in level walking were determined by means of an EMG to force processor, based on a muscle analogue (Hof and Van den Berg (1981) J. Biomechanics, 14, 747-758, 759-770, 771-785, 787-792). Nine subjects (four women, five men) walked on a level treadmill at speeds between 0.5 and ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(83)90067-2

    authors: Hof AL,Geelen BA,Van den Berg J

    更新日期:1983-01-01 00:00:00

  • A finite element musculoskeletal model of the shoulder mechanism.

    abstract::The finite element method described in this study provides an easy method to simulate the kinetics of multibody mechanisms. It is used in order to develop a musculoskeletal model of the shoulder mechanism. Each relevant morphological structure has been represented by an appropriate element. For the shoulder mechanism ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90065-5

    authors: van der Helm FC

    更新日期:1994-05-01 00:00:00

  • Tensile experiments and SEM fractography on bovine subchondral bone.

    abstract::Subchondral bone undecalcified samples, extracted from bovine femoral heads, are subjected to a direct tensile load. The Young's modulus of each sample is determined from repeated tests within the elastic limit. In a last test, the tensile load is increased up to the specimen failure, determining the ultimate tensile ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00074-9

    authors: Braidotti P,Bemporad E,D'Alessio T,Sciuto SA,Stagni L

    更新日期:2000-09-01 00:00:00

  • Wireless GPS-based phase-locked synchronization system for outdoor environment.

    abstract::Synchronization of data coming from different sources is of high importance in biomechanics to ensure reliable analyses. This synchronization can either be performed through hardware to obtain perfect matching of data, or post-processed digitally. Hardware synchronization can be achieved using trigger cables connectin...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.09.014

    authors: Meyer F,Bahr A,Lochmatter T,Borrani F

    更新日期:2012-01-03 00:00:00

  • A new approach for surface fitting method of articular joint surfaces.

    abstract::The application of joint contact mechanics requires a precise configuration of the joint surfaces. B-Spline, and NURBS have been widely used to model joint surfaces, but because these formulations use a structured data set provided by a rectangular net first, then a grid, there is a limit to the accuracy of the models...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.01.009

    authors: Hirokawa S,Ueki T,Ohtsuki A

    更新日期:2004-10-01 00:00:00

  • A survey of micro-finite element analysis for clinical assessment of bone strength: the first decade.

    abstract::Micro-Finite Element (micro-FE) analysis is now widely used in biomedical research as a tool to derive bone mechanical properties as they relate to its microstructure. With the development of in vivo high-resolution peripheral quantitative CT (HR-pQCT) scanners, it can now be applied to analyze bone in-vivo in the per...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.12.024

    authors: van Rietbergen B,Ito K

    更新日期:2015-03-18 00:00:00

  • Sex differences in postures of the upper body during a simulated work task performed above shoulder level.

    abstract::The aim of this study was to evaluate if there are sex differences in postures of upper arm, upper back, head and neck after muscle fatigue induced by a simulated work task, requiring upper arm movements performed above shoulder level. Nineteen females and 18 males were evaluated. Upper arm elevation, upper back, head...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109855

    authors: Cid MM,Côté JN,Zancanaro LL,Oliveira AB

    更新日期:2020-06-23 00:00:00

  • Quantifying the history dependency of muscle recovery from a fatiguing intermittent task.

    abstract::Muscle fatigue and recovery are complex processes influencing muscle force generation capacity. While fatigue reduces this capacity, recovery acts to restore the unfatigued muscle state. Many factors can potentially affect muscle recovery, and among these may be a task dependency of recovery following an exercise. How...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.061

    authors: Rashedi E,Nussbaum MA

    更新日期:2017-01-25 00:00:00

  • Compressive and shear hip joint contact forces are affected by pediatric obesity during walking.

    abstract::Obese children exhibit altered gait mechanics compared to healthy-weight children and have an increased prevalence of hip pain and pathology. This study sought to determine the relationships between body mass and compressive and shear hip joint contact forces during walking. Kinematic and kinetic data were collected d...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.033

    authors: Lerner ZF,Browning RC

    更新日期:2016-06-14 00:00:00

  • Sensitivity of dynamic simulations of gait and dynamometer experiments to hill muscle model parameters of knee flexors and extensors.

    abstract::We assessed and compared sensitivities of dynamic simulations to musculotendon (MT) parameters for gait and dynamometer experiments. Our aim with this comparison was to investigate whether dynamometer experiments could provide information about MT-parameters that are important to reliably study MT-function during gait...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.03.022

    authors: De Groote F,Van Campen A,Jonkers I,De Schutter J