Wireless GPS-based phase-locked synchronization system for outdoor environment.

Abstract:

:Synchronization of data coming from different sources is of high importance in biomechanics to ensure reliable analyses. This synchronization can either be performed through hardware to obtain perfect matching of data, or post-processed digitally. Hardware synchronization can be achieved using trigger cables connecting different devices in many situations; however, this is often impractical, and sometimes impossible in outdoors situations. The aim of this paper is to describe a wireless system for outdoor use, allowing synchronization of different types of - potentially embedded and moving - devices. In this system, each synchronization device is composed of: (i) a GPS receiver (used as time reference), (ii) a radio transmitter, and (iii) a microcontroller. These components are used to provide synchronized trigger signals at the desired frequency to the measurement device connected. The synchronization devices communicate wirelessly, are very lightweight, battery-operated and thus very easy to set up. They are adaptable to every measurement device equipped with either trigger input or recording channel. The accuracy of the system was validated using an oscilloscope. The mean synchronization error was found to be 0.39 μs and pulses are generated with an accuracy of <2 μs. The system provides synchronization accuracy about two orders of magnitude better than commonly used post-processing methods, and does not suffer from any drift in trigger generation.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Meyer F,Bahr A,Lochmatter T,Borrani F

doi

10.1016/j.jbiomech.2011.09.014

subject

Has Abstract

pub_date

2012-01-03 00:00:00

pages

188-90

issue

1

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(11)00613-0

journal_volume

45

pub_type

杂志文章
  • A musculoskeletal model of the human lower extremity: the effect of muscle, tendon, and moment arm on the moment-angle relationship of musculotendon actuators at the hip, knee, and ankle.

    abstract::We have developed a musculoskeletal model of the human lower extremity for computer simulation studies of musculotendon function and muscle coordination during movement. This model incorporates the salient features of muscle and tendon, specifies the musculoskeletal geometry and musculotendon parameters of 18 musculot...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90349-8

    authors: Hoy MG,Zajac FE,Gordon ME

    更新日期:1990-01-01 00:00:00

  • Validation of the greater trochanter method with radiographic measurements of frontal plane hip joint centers and knee mechanical axis angles and two other hip joint center methods.

    abstract::Several motion capture methods exist for predicting hip joint centers (HJC). These methods include regression models, functional joints, and projections from greater trochanters. While regression and functional methods have been compared to imaging techniques, the TROCH method has not been previously validated. The pu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.06.013

    authors: Bennett HJ,Shen G,Weinhandl JT,Zhang S

    更新日期:2016-09-06 00:00:00

  • Vocal fold contact patterns based on normal modes of vibration.

    abstract::The fluid-structure interaction and energy transfer from respiratory airflow to self-sustained vocal fold oscillation continues to be a topic of interest in vocal fold research. Vocal fold vibration is driven by pressures on the vocal fold surface, which are determined by the shape of the glottis and the contact betwe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.04.011

    authors: Smith SL,Titze IR

    更新日期:2018-05-17 00:00:00

  • Scapular kinematic is altered after electromyography biofeedback training.

    abstract::Electromyography (EMG) biofeedback training affords patients a better sense of the different muscle activation patterns involved in the movement of the shoulder girdle. It is important to address scapular kinematics with labourers who have daily routines involving large amounts of lifting at shoulder level or higher. ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.04.036

    authors: San Juan JG,Gunderson SR,Kane-Ronning K,Suprak DN

    更新日期:2016-06-14 00:00:00

  • Dynamic shear behavior of mandibular condylar cartilage is dependent on testing direction.

    abstract::Little information is available on the direction-dependency of shear behavior in mandibular condylar cartilage. Therefore, we tested the hypothesis that such a dependency of the dynamic shear properties is present in mandibular condylar cartilage. From each of 17 condyles, two cartilage-bone plugs were dissected and t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.12.012

    authors: Tanaka E,Iwabuchi Y,Rego EB,Koolstra JH,Yamano E,Hasegawa T,Kawazoe A,Kawai N,Tanne K

    更新日期:2008-01-01 00:00:00

  • An in vitro experimental study on the relationship between pulsatile tinnitus and the dehiscence/thinness of sigmoid sinus cortical plate.

    abstract::Pulsatile tinnitus (PT), characterized as pulse-synchronous, is generally objective. Sigmoid sinus (SS) venous sound is widely suggested to be a possible sound source of PT. The dehiscence and thinness of SS cortical plate (CP) was commonly reported as PT pathology in previous studies, but lack quantitative or biomech...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.12.049

    authors: Tian S,Fan X,Wang Y,Liu Z,Wang L

    更新日期:2019-02-14 00:00:00

  • Factors influencing performance in the Hecht vault and implications for modelling.

    abstract::This paper investigated the factors that influence Hecht vault performance and assessed the level of model complexity required to give an adequate representation of vaulting. A five-segment planar simulation model with a visco-elastic shoulder joint and a torque generator at the shoulder joint was used to simulate the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.02.039

    authors: King MA,Yeadon MR

    更新日期:2005-01-01 00:00:00

  • Biomedical microfluidic devices by using low-cost fabrication techniques: A review.

    abstract::One of the most popular methods to fabricate biomedical microfluidic devices is by using a soft-lithography technique. However, the fabrication of the moulds to produce microfluidic devices, such as SU-8 moulds, usually requires a cleanroom environment that can be quite costly. Therefore, many efforts have been made t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2015.11.031

    authors: Faustino V,Catarino SO,Lima R,Minas G

    更新日期:2016-07-26 00:00:00

  • A theoretical and non-destructive experimental approach for direct inclusion of measured collagen orientation and recruitment into mechanical models of the artery wall.

    abstract::Gradual collagen recruitment has been hypothesized as the underlying mechanism for the mechanical stiffening with increasing stress in arteries. In this work, we investigated this hypothesis in eight rabbit carotid arteries by directly measuring the distribution of collagen recruitment stretch under increasing circumf...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.11.016

    authors: Hill MR,Duan X,Gibson GA,Watkins S,Robertson AM

    更新日期:2012-03-15 00:00:00

  • Biaxial mechanical testing of human sclera.

    abstract::The biomechanical environment of the optic nerve head (ONH), of interest in glaucoma, is strongly affected by the biomechanical properties of sclera. However, there is a paucity of information about the variation of scleral mechanical properties within eyes and between individuals. We thus used biaxial testing to meas...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.02.031

    authors: Eilaghi A,Flanagan JG,Tertinegg I,Simmons CA,Wayne Brodland G,Ross Ethier C

    更新日期:2010-06-18 00:00:00

  • Analytical modeling of the instantaneous maximal transvalvular pressure gradient in aortic stenosis.

    abstract::In presence of aortic stenosis, a jet is produced downstream of the aortic valve annulus during systole. The vena contracta corresponds to the location where the cross-sectional area of the flow jet is minimal. The maximal transvalvular pressure gradient (TPG(max)) is the difference between the static pressure in the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.10.013

    authors: Garcia D,Kadem L,Savéry D,Pibarot P,Durand LG

    更新日期:2006-01-01 00:00:00

  • Lumbar spinal muscle activation synergies predicted by multi-criteria cost function.

    abstract::The hypothesis that control of lumbar spinal muscle synergies is biomechanically optimized was studied by comparing EMG data with an analytical model with a multi-component cost function that could include (1) trunk displacements, (2) intervertebral displacements, (3) intervertebral forces; (4) sum of cubed muscle str...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00034-3

    authors: Stokes IA,Gardner-Morse M

    更新日期:2001-06-01 00:00:00

  • Collagen fibril diameters increase and fibril densities decrease in skin subjected to repetitive compressive and shear stresses.

    abstract::Understanding microstructural changes that occur in skin subjected to repetitive mechanical stress is crucial towards the development of therapies to enhance skin adaptation and load tolerance in patients at risk of skin breakdown (e.g. prosthesis users, wheelchair users). To determine if collagen fibril diameter, col...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00145-2

    authors: Sanders JE,Goldstein BS

    更新日期:2001-12-01 00:00:00

  • Effect of boundary conditions, impact loading and hydraulic stiffening on femoral fracture strength.

    abstract::Patient specific quantitative CT (QCT) imaging data together with the finite element (FE) method may provide an accurate prediction of a patient's femoral strength and fracture risk. Although numerous FE models investigating femoral fracture strength have been published, there is little consent on the effect of bounda...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.07.004

    authors: Haider IT,Speirs AD,Frei H

    更新日期:2013-09-03 00:00:00

  • Torsional stiffness and strength of the proximal tibia are better predicted by finite element models than DXA or QCT.

    abstract::Individuals with spinal cord injury experience a rapid loss of bone mineral below the neurological lesion. The clinical consequence of this bone loss is a high rate of fracture around regions of the knee. The ability to predict the mechanical competence of bones at this location may serve as an important clinical tool...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.04.016

    authors: Edwards WB,Schnitzer TJ,Troy KL

    更新日期:2013-06-21 00:00:00

  • A dual optimization method for the material parameter identification of a biphasic poroviscoelastic hydrogel: Potential application to hypercompliant soft tissues.

    abstract::A dual-indentation creep and stress relaxation methodology was developed and validated for the material characterization of very soft biological tissue within the framework of the biphasic poroviscoelastic (BPVE) constitutive model. Agarose hydrogel, a generic porous medium with mobile fluid, served as a mechanical ti...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.07.019

    authors: Olberding JE,Francis Suh JK

    更新日期:2006-01-01 00:00:00

  • Biomechanical analysis of the stance phase during barefoot and shod running.

    abstract::This study investigated spatio-temporal variables, ground reaction forces and sagittal and frontal plane kinematics during the stance phase of nine trained subjects running barefoot and shod at three different velocities (3.5, 4.5, 5.5 m s(-1)). Differences between conditions were detected with the general linear meth...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00192-x

    authors: De Wit B,De Clercq D,Aerts P

    更新日期:2000-03-01 00:00:00

  • Comparison of measurements of medial gastrocnemius architectural parameters from ultrasound and diffusion tensor images.

    abstract::In vivo measurements of muscle architecture provide insight into inter-individual differences in muscle function and could be used to personalise musculoskeletal models. When muscle architecture is measured from ultrasound images, as is frequently done, it is assumed that fascicles are oriented in the image plane and,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.01.012

    authors: Bolsterlee B,Veeger HE,van der Helm FC,Gandevia SC,Herbert RD

    更新日期:2015-04-13 00:00:00

  • Accuracy of a contour-based biplane fluoroscopy technique for tracking knee joint kinematics of different speeds.

    abstract::While measuring knee motion in all six degrees of freedom is important for understanding and treating orthopaedic knee pathologies, traditional motion capture techniques lack the required accuracy. A variety of model-based biplane fluoroscopy techniques have been developed with sub-millimeter accuracy. However, no stu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.08.045

    authors: Giphart JE,Zirker CA,Myers CA,Pennington WW,LaPrade RF

    更新日期:2012-11-15 00:00:00

  • Hamstring muscle-tendon unit lengthening and activation in instep and cut-off kicking.

    abstract::Hamstring muscle strain injury is one of the most common injuries in sports involving sprinting and kicking. Studies examining hamstring kinematics and activations are rich for sprinting but lacking for kicking. The purpose of this study was to examine kinematics and activations of hamstring muscles in instep and cut-...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109482

    authors: Zhang L,Li H,Garrett WE,Liu H,Yu B

    更新日期:2020-01-23 00:00:00

  • Volume effects on fatigue life of equine cortical bone.

    abstract::Materials, including bone, often fail due to loading in the presence of critical flaws. The relative amount, location, and interaction of these flaws within a stressed volume of material play a role in determining the failure properties of the structure. As materials are generally imperfect, larger volumes of material...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.05.025

    authors: Bigley RF,Gibeling JC,Stover SM,Hazelwood SJ,Fyhrie DP,Martin RB

    更新日期:2007-01-01 00:00:00

  • Opto-mechanical characterization of sclera by polarization sensitive optical coherence tomography.

    abstract::Polarization sensitive optical coherence tomography (PSOCT) is an interferometric technique sensitive to birefringence. Since mechanical loading alters the orientation of birefringent collagen fibrils, we asked if PSOCT can be used to measure local mechanical properties of sclera. Infrared (1300 nm) PSOCT was performe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.03.017

    authors: Shin A,Park J,Demer JL

    更新日期:2018-04-27 00:00:00

  • An application of beam theory to determine the stress and deformation of long bones.

    abstract::We present a generalized beam theory in which deformation and load are determined simultaneously, in order to analyze statically indeterminant problems involving long bones. We regard a long bone as a beam curved in three dimensions for which the cross-sectional properties vary continuously along its length. The theor...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90087-0

    authors: Salathe EP Jr,Arangio GA,Salathe EP

    更新日期:1989-01-01 00:00:00

  • Changes in stationary upright standing and proprioceptive reflex control of foot muscles after fatiguing static foot inversion.

    abstract::We searched for the consequences of a maximal static foot inversion sustained until exhaustion on the post-exercise stationary upright standing and the proprioceptive control of the foot muscles. Twelve healthy subjects executed an unilateral maximal static foot inversion during which continuous power spectrum analyse...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.04.005

    authors: Vie B,Gomez N,Brerro-Saby C,Weber JP,Jammes Y

    更新日期:2013-06-21 00:00:00

  • A unified multiscale mechanical model for soft collagenous tissues with regular fiber arrangement.

    abstract::In this paper the mechanical response of soft collagenous tissues with regular fiber arrangement (RSCTs) is described by means of a nanoscale model and a two-step micro-macro homogenization technique. The non-linear collagen constitutive behavior is modeled at the nanoscale by a novel approach accounting for entropic ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.07.040

    authors: Maceri F,Marino M,Vairo G

    更新日期:2010-01-19 00:00:00

  • Intravoxel bone micromechanics for microCT-based finite element simulations.

    abstract::While micro-FE simulations have become a standard tool in computational biomechanics, the choice of appropriate material properties is still a relevant topic, typically involving empirical grey value-to-elastic modulus relations. We here derive the voxel-specific volume fractions of mineral, collagen, and water, from ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.06.036

    authors: Blanchard R,Dejaco A,Bongaers E,Hellmich C

    更新日期:2013-10-18 00:00:00

  • Translational constraint influences dynamic spinal canal occlusion of the thoracic spine: an in vitro experimental study.

    abstract::Mechanical constraints to spine motion can arise in a variety of real-world situations such as when shoulder belts prevent anterior translation of the thorax during automotive collisions. The effect of such constraint on spinal column-spinal cord interaction during injury remains unknown. The purpose of the present st...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.06.030

    authors: Zhu Q,Lane C,Ching RP,Gordon JD,Fisher CG,Dvorak MF,Cripton PA,Oxland TR

    更新日期:2008-01-01 00:00:00

  • Biomechanical evaluation of the docking nail concept in periprosthetic fracture fixation around a stemmed total knee arthroplasty.

    abstract::Intramedullary femoral nails provide an ideal mechanical axis for periprosthetic fracture fixation. Slotted nails allow a connection to a total knee arthroplasty (TKA) stem. This study aims to compare implant and construct stiffness, interfragmentary movement and cycles to failure between an antegrade slotted femoral ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110109

    authors: Lenz M,Acklin YP,Kasper LA,Mischler D,Varga P,Zderic I,Gehweiler D,Klos K,Gueorguiev B,Stoffel K

    更新日期:2021-01-22 00:00:00

  • Pain catastrophizing moderates changes in spinal control in response to noxiously induced low back pain.

    abstract::It is generally accepted that spine control and stability are relevant for the prevention and rehabilitation of low back pain (LBP). However, there are conflicting results in the literature in regards to how these variables are modified in the presence of LBP. The aims of the present work were twofold: (1) to use noxi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.04.010

    authors: Ross GB,Sheahan PJ,Mahoney B,Gurd BJ,Hodges PW,Graham RB

    更新日期:2017-06-14 00:00:00

  • The use of a single sacral marker method to approximate the centre of mass trajectory during treadmill running.

    abstract::The three-dimensional trajectory of the body's centre of mass (COM) is useful to determine a number of biomechanical outcomes in running research. Previous studies have used the COM to calculate measures such as overstriding, vertical stiffness, and vertical oscillation. The COM is traditionally computed using the seg...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109886

    authors: Napier C,Jiang X,MacLean CL,Menon C,Hunt MA

    更新日期:2020-07-17 00:00:00