Comparison of measurements of medial gastrocnemius architectural parameters from ultrasound and diffusion tensor images.

Abstract:

:In vivo measurements of muscle architecture provide insight into inter-individual differences in muscle function and could be used to personalise musculoskeletal models. When muscle architecture is measured from ultrasound images, as is frequently done, it is assumed that fascicles are oriented in the image plane and, for some measurements, that the image plane is perpendicular to the aponeurosis at the intersection of fascicle and aponeurosis. This study presents an in vivo validation of these assumptions by comparing ultrasound image plane orientation to three-dimensional reconstructions of muscle fascicles and aponeuroses obtained with diffusion tensor imaging (DTI) and high-resolution anatomical MRI scans. It was found that muscle fascicles were oriented on average at 5.5±4.1° to the ultrasound image plane. On average, ultrasound yielded similar measurements of fascicle lengths to DTI (difference <3mm), suggesting that the measurements were unbiased. The absolute difference in length between any pair of measurements made with ultrasound and DTI was substantial (10mm or 20% of the mean), indicating that the measurements were imprecise. Pennation angles measured with ultrasound were significantly smaller than those measured with DTI (mean difference 6°). This difference was apparent only at the superficial insertion of the muscle fascicles so it was probably due to pressure on the skin applied by the ultrasound probes. It is concluded that ultrasound measurements of deep pennation angles and fascicle lengths in the medial gastrocnemius are unbiased but have a low precision and that superficial pennation angles are underestimated by approximately 10°. The low precision limits the use of ultrasound to personalise fascicle length in musculoskeletal models.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Bolsterlee B,Veeger HE,van der Helm FC,Gandevia SC,Herbert RD

doi

10.1016/j.jbiomech.2015.01.012

subject

Has Abstract

pub_date

2015-04-13 00:00:00

pages

1133-40

issue

6

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(15)00024-X

journal_volume

48

pub_type

杂志文章
  • Validation of the greater trochanter method with radiographic measurements of frontal plane hip joint centers and knee mechanical axis angles and two other hip joint center methods.

    abstract::Several motion capture methods exist for predicting hip joint centers (HJC). These methods include regression models, functional joints, and projections from greater trochanters. While regression and functional methods have been compared to imaging techniques, the TROCH method has not been previously validated. The pu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.06.013

    authors: Bennett HJ,Shen G,Weinhandl JT,Zhang S

    更新日期:2016-09-06 00:00:00

  • Combining muscle synergies and biomechanical analysis to assess gait in stroke patients.

    abstract::The understanding of biomechanical deficits and impaired neural control of gait after stroke is crucial to prescribe effective customized treatments aimed at improving walking function. Instrumented gait analysis has been increasingly integrated into the clinical practice to enhance precision and inter-rater reliabili...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.08.006

    authors: Barroso FO,Torricelli D,Molina-Rueda F,Alguacil-Diego IM,Cano-de-la-Cuerda R,Santos C,Moreno JC,Miangolarra-Page JC,Pons JL

    更新日期:2017-10-03 00:00:00

  • Velocity profiles in annular perfusion chamber measured by laser-Doppler velocimetry.

    abstract::p6e fluid flow in the annular perfusion chamber of Baumgartner developed to study platelet vessel wall interaction was examined with laser-Doppler velocimetry. A laminar and stable flow with a Reynolds number of less than or equal to 50 was measured at flow rates up to 3 ml s-1. No turbulence was found. The wall shear...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(84)90081-2

    authors: Aarts PA,van Broek JA,Kuiken GD,Sixma JJ,Heethaar RM

    更新日期:1984-01-01 00:00:00

  • Determination of biomechanical characteristics of restrictive adhesions and of functional impairment after flexor tendon surgery: a methodological study of rabbits.

    abstract::Formation of restrictive adhesions is one of the main obstacles in rehabilitation following hand surgery. Most experimental work, however, involves only a macroscopic and/or histologic evaluation of the amount of adhesions, and their functional characteristics are poorly described. The aim of this study was to develop...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90171-i

    authors: Hagberg L,Wik O,Gerdin B

    更新日期:1991-01-01 00:00:00

  • Non-linear rotation-free shell finite-element models for aortic heart valves.

    abstract::Hyperelastic material models have been incorporated in the rotation-free, large deformation, shell finite element (FE) formulation of (Stolarski et al., 2013) and applied to dynamic simulations of aortic heart valve. Two models used in the past in analysis of such problem i.e. the Saint-Venant and May-Newmann-Yin (MNY...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.031

    authors: Gilmanov A,Stolarski H,Sotiropoulos F

    更新日期:2017-01-04 00:00:00

  • Evaluation of residual stresses due to bone callus growth: a computational study.

    abstract::Mechanical environment in callus is determinant for the evolution of bone healing. However, recent mechanobiological computational works have underestimated the effect that growth exerts on the mechanical environment of callus. In the present work, we computationally evaluate the significance of growth-induced stresse...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.04.021

    authors: González-Torres LA,Gómez-Benito MJ,García-Aznar JM

    更新日期:2011-06-03 00:00:00

  • A new in vivo technique for determination of femoro-tibial and femoro-patellar 3D kinematics in total knee arthroplasty.

    abstract::Aim was to develop an in vivo technique which allows determination of femoro-tibial and of femoro-patellar 3D-kinematics in TKA simultaneously. The knees of 20 healthy volunteers and of eight patients with TKA (PCR, rotating platform) were investigated. Kinematics analysis was performed in an open MR-system at differe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.03.020

    authors: von Eisenhart-Rothe R,Vogl T,Englmeier KH,Graichen H

    更新日期:2007-01-01 00:00:00

  • Assessment of blood volume flow in slightly curved arteries from a single velocity profile.

    abstract::Non-invasive estimation of arterial blood volume flow (BVF) has become a central issue in assessment of cardiovascular risk. Poiseuille and Womersley approaches are commonly used to assess the BVF from centerline velocity, but both methods neglect the influence of curvature. Based on the assumption that the velocity i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.04.032

    authors: Leguy CA,Bosboom EM,Hoeks AP,van de Vosse FN

    更新日期:2009-08-07 00:00:00

  • Force-sharing between cat soleus and gastrocnemius muscles during walking: explanations based on electrical activity, properties, and kinematics.

    abstract::Studying force sharing between synergistic muscles can be useful for understanding the functional significance of musculoskeletal redundancy and the mechanisms underlying the control of synergistic muscles. The purpose of this study was to quantify and explain force sharing between cat soleus (SO) and gastrocnemius (G...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90276-3

    authors: Prilutsky BI,Herzog W,Allinger TL

    更新日期:1994-10-01 00:00:00

  • Muscle fatigue does not lead to increased instability of upper extremity repetitive movements.

    abstract::Muscle fatigue alters neuromuscular responses. This may lead to increased sensitivity to perturbations and possibly to subsequent injury risk. We studied the effects of muscle fatigue on movement stability during a repetitive upper extremity task. Twenty healthy young subjects performed a repetitive work task, similar...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.11.001

    authors: Gates DH,Dingwell JB

    更新日期:2010-03-22 00:00:00

  • Fracture-toughening mechanisms responsible for differences in work to fracture of hydrated and dehydrated dentine.

    abstract::This study investigates the nature of deformation and differences in the mechanisms of fracture and properties of dentine where there has been a loss of moisture, as may occur with removal of the pulp in the endodontic treatment of teeth. Controlled fracture toughness testing was conducted on bovine teeth to determine...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00327-5

    authors: Kahler B,Swain MV,Moule A

    更新日期:2003-02-01 00:00:00

  • Effects of different temperatures, velocities and loads on the gliding resistance of flexor digitorum profundus tendons in a human cadaver model.

    abstract::The purpose of this study was to investigate the effects of temperature, velocity and load on the gliding resistance (GR) of flexor digitorum profundus (FDP) tendons in a human cadaver model. A total of 40 FDP tendons from the index through small digits of ten human cadavers were tested to assess the effect of tempera...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.01.011

    authors: Moriya T,Chikenji T,Thoreson AR,Zhao C,An KN,Amadio PC

    更新日期:2011-04-29 00:00:00

  • Parametric and subject-specific finite element modelling of the lower cervical spine. Influence of geometrical parameters on the motion patterns.

    abstract::Morphometrical and postural features of the cervical spine are supposed to significantly influence its biomechanical behaviour. However, the effects of these geometrical parameters are quite difficult to evaluate. An original numerical method is proposed in order to automatically generate parametric and subject-specif...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.04.007

    authors: Laville A,Laporte S,Skalli W

    更新日期:2009-07-22 00:00:00

  • Hemiarthroplasty of hip joint: An experimental validation using porcine acetabulum.

    abstract::Biphasic properties of articular cartilage allow it to be an excellent bearing material and have been studied through several simplified experiments as well as finite element modelling. However, three-dimensional biphasic finite element (FE) models of the whole joint are rare. The current study was carried out to expe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.02.140

    authors: Pawaskar SS,Grosland NM,Ingham E,Fisher J,Jin Z

    更新日期:2011-05-17 00:00:00

  • An evaluation of anatomical and functional knee axis definition in the context of side-cutting.

    abstract::Side-cutting is commonly used to evaluate knee joint kinematics and kinetics in the context of anterior cruciate ligament injury risk. Many existing side-cutting studies fail to clearly define the orientation of the femoral frame and the knee axis, making comparisons between studies difficult. A femoral frame construc...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.05.017

    authors: Robinson MA,Vanrenterghem J

    更新日期:2012-07-26 00:00:00

  • Stress relaxation of human ankles is only minimally affected by knee and ankle angle.

    abstract::Comprehensive characterization of stress relaxation in musculotendinous structures is needed to create robust models of viscoelastic behavior. The commonly used quasi-linear viscoelastic (QLV) theory requires that the relaxation response be independent of tissue strain (length). This study aims to characterize stress ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.11.017

    authors: Tian M,Hoang PD,Gandevia SC,Bilston LE,Herbert RD

    更新日期:2010-03-22 00:00:00

  • Kinematic performance of a six degree-of-freedom hand model (6DHand) for use in occupational biomechanics.

    abstract::Upper extremity musculoskeletal disorders represent an important health issue across all industry sectors; as such, the need exists to develop models of the hand that provide comprehensive biomechanics during occupational tasks. Previous optical motion capture studies used a single marker on the dorsal aspect of finge...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.04.003

    authors: Buczek FL,Sinsel EW,Gloekler DS,Wimer BM,Warren CM,Wu JZ

    更新日期:2011-06-03 00:00:00

  • Kinematic evaluation of cruciate-retaining total knee replacement patients during level walking: a comparison with the displacement-controlled ISO standard.

    abstract::Differences between wear-scar features of simulator-tested and retrieved tibial total knee replacement (TKR) liners have been reported. This disagreement may result from differences between in vivo kinematic profiles and those defined by the International Organization for Standardization (ISO). The purpose of this stu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.06.030

    authors: Ngai V,Wimmer MA

    更新日期:2009-10-16 00:00:00

  • Foot contact identification using a single triaxial accelerometer during running.

    abstract::The analysis of in-field biomechanics data typically requires the identification of foot contact. Existing techniques to identify foot contact using accelerometers offer a viable option for identifying foot contact in the field. However, these techniques often require the placement of additional accelerometers or the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109768

    authors: Aubol KG,Milner CE

    更新日期:2020-05-22 00:00:00

  • Biomechanical and structural properties of the explanted bioprosthetic valve leaflets.

    abstract::Porcine bioprosthesis were treated with 0.625% glutaraldehyde and stabilized under changing pressure from 4 to 30 mmHg. Bovine pericardium and 12 biovalves (of age between 14 days and 80 months) after implantation in the human body were investigated (7 porcine PB and 5 pericardial bioprosthesis--PCB). Circumferential ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90027-2

    authors: Purinya B,Kasyanov V,Volkolakov J,Latsis R,Tetere G

    更新日期:1994-01-01 00:00:00

  • Mechanical effects of continuous passive motion on the lumbar spine in seating.

    abstract::The aim of this study was to develop a model which describes the mechanical spinal response to small alternating pelvic stimulation induced by an active rotational movement of a normal chair. The rotary continuous passive motion (RCPM) of the seat about a vertical axis of only 0.6 degrees resulted in an increased in s...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00231-6

    authors: van Deursen DL,Lengsfeld M,Snijders CJ,Evers JJ,Goossens RH

    更新日期:2000-06-01 00:00:00

  • On practical evaluation of differentiation techniques for human gait analysis.

    abstract::Numerical differentiation of noisy measurement data represents a problem frequently encountered in the field of gait analysis. There are two major determinants of the quality in calculated derivatives, namely the quality of the measurement data and the quality of the used differentiation technique. The quality of the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(82)90041-0

    authors: Lanshammar H

    更新日期:1982-01-01 00:00:00

  • Passive and active muscle stiffness in plantar flexors of long distance runners.

    abstract::The aim of the present study was to compare passive and active muscle stiffness and tendon stiffness between long distance runners and untrained men. Twenty long distance runners and 24 untrained men participated in this study. Active muscle stiffness in the medial gastrocnemius muscle was calculated according to chan...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.04.012

    authors: Kubo K,Miyazaki D,Yamada K,Yata H,Shimoju S,Tsunoda N

    更新日期:2015-07-16 00:00:00

  • A fiber-reinforced composite model of the viscoelastic behavior of the brainstem in shear.

    abstract::Brainstem trauma occurs frequently in severe head injury, often resulting in fatal lesions due to importance of brainstem in crucial neural functions. Structurally, the brainstem is composed of bundles of axonal fibers distinctly oriented in a longitudinal direction surrounded by an extracellular matrix. We hypothesiz...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00042-1

    authors: Arbogast KB,Margulies SS

    更新日期:1999-08-01 00:00:00

  • Effect of foods on selected dynamic parameters of mandibular elevator muscles during symmetric incisal biting.

    abstract::The paper focuses on research that enables the relationship between food and selected mechanical parameters do be determined. The main aim of the study was to designate, depending on the food: (1) the work of a single muscle (i.e. masseter, medial pterygoid, temporalis), and (2) the energy balance of mandibular elevat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109800

    authors: Stróżyk P,Jacek B

    更新日期:2020-06-09 00:00:00

  • A novel validation and calibration method for motion capture systems based on micro-triangulation.

    abstract::Motion capture systems are widely used to measure human kinematics. Nevertheless, users must consider system errors when evaluating their results. Most validation techniques for these systems are based on relative distance and displacement measurements. In contrast, our study aimed to analyse the absolute volume accur...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.04.009

    authors: Nagymáté G,Tuchband T,Kiss RM

    更新日期:2018-06-06 00:00:00

  • Do quadrupeds require a change in trunk posture to walk backward?

    abstract::Previous studies on cats walking backward have indicated that they adopt a presumably adaptive posture characterized by extreme dorsiflexion of the lumbar spine. Because humans do not show any marked postural changes during backward walking, we questioned whether the posture exhibited by cats during backward walking w...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00071-3

    authors: Vilensky JA,Cook JA

    更新日期:2000-08-01 00:00:00

  • Comparison of biomechanical failure criteria for abdominal aortic aneurysm.

    abstract::Medical doctors consider a surgery option for the expanding abdominal aortic aneurysm (AAA) when its maximum diameter reaches 5.5cm. This simple geometrical criterion may possibly underestimate the risks of rupture of small aneurysms as well as overestimate the risks of rupture of large aneurysms. Biomechanical criter...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.03.024

    authors: Volokh KY

    更新日期:2010-07-20 00:00:00

  • An effortless procedure to align the local frame of an inertial measurement unit to the local frame of another motion capture system.

    abstract::Inertial measurement units (IMUs) offer great opportunities to analyze segmental and joints kinematics. When combined with another motion capture system (MCS), for example, to validate new IMU-based applications or to develop mixed systems, it is necessary to align the local frame of the IMU sensors to the local frame...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.06.009

    authors: Chardonnens J,Favre J,Aminian K

    更新日期:2012-08-31 00:00:00

  • Age-associated changes in the mechanical properties of human cadaveric pelvic floor muscles.

    abstract::Proper function of the female pelvic floor requires intact pelvic floor muscles (PFMs). The prevalence of pelvic floor disorders (PFDs) increases substantially with age, in part due to clinically identified deterioration of PFM function with age. However, the etiology of this decline remains largely unknown. We previo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109436

    authors: Burnett LA,Cook M,Shah S,Michelle Wong M,Kado DM,Alperin M

    更新日期:2020-01-02 00:00:00