Foot contact identification using a single triaxial accelerometer during running.

Abstract:

:The analysis of in-field biomechanics data typically requires the identification of foot contact. Existing techniques to identify foot contact using accelerometers offer a viable option for identifying foot contact in the field. However, these techniques often require the placement of additional accelerometers or the identification of impact peaks, which can be difficult when peaks are low. Using resultant tibial acceleration to identify foot contact may overcome these limitations. The purpose of this study was to develop a new technique for identifying time of foot contact during rearfoot strike running from a single triaxial accelerometer placed on the distal tibia. Additionally, we sought to establish the concurrent validity of this new technique. An algorithm to identify foot contact from a local minimum in the resultant tibial acceleration waveform was developed and tested in nineteen rearfoot strike runners. Foot contact determined from the resultant tibial acceleration occurred 2.3 ± 4.7 ms earlier than foot contact determined from vertical ground reaction force, with 95% limits of agreement of -6.8 to 11.5 ms. The difference between the two methods was less than 10 ms for 183 out of 190 foot contacts. These findings compare favorably to previous techniques for identifying foot contact using accelerometers. Additionally, this technique can also be used when peak tibial accelerations are low. We recommend this technique to identify foot contacts in the field, particularly when some peak values are expected to be low.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Aubol KG,Milner CE

doi

10.1016/j.jbiomech.2020.109768

subject

Has Abstract

pub_date

2020-05-22 00:00:00

pages

109768

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(20)30184-6

journal_volume

105

pub_type

杂志文章
  • The sensitivity of cartilage contact pressures in the knee joint to the size and shape of an anatomically shaped meniscal implant.

    abstract::Since meniscal geometry affects the cartilage contact pressures, it is essential to carefully define the geometry of the synthetic meniscal implant that we developed. Recently, six independent modes of size- and shape-related geometry variation were identified through 3D statistical shape modeling (SSM) of the medial ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.034

    authors: Khoshgoftar M,Vrancken AC,van Tienen TG,Buma P,Janssen D,Verdonschot N

    更新日期:2015-06-01 00:00:00

  • Longitudinal strain of canine and porcine aortas.

    abstract::The in situ longitudinal strain of canine and porcine aortas was investigated. Marks of black water-resistant ink were placed on the aortas and the axial lengths between the marks were measured in situ and in vitro. When the aortas were cut, the retraction was measured and described by the stretch ratio, which is defi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)00091-h

    authors: Han HC,Fung YC

    更新日期:1995-05-01 00:00:00

  • An anatomy-based coordinate system for the description of the kinematic displacements in the human knee.

    abstract::The effects and interaction of the anatomical displacements in the human knee are a prerequisite to an accurate assessment and communication of the kinematic data. For the kinematic information to be used to improve diagnosis and treatment, and for better prosthetic design and installation, there must be clear, concis...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90378-g

    authors: Pennock GR,Clark KJ

    更新日期:1990-01-01 00:00:00

  • Endothelialization of over- and undersized flow-diverter stents at covered vessel side branches: An in vivo and in silico study.

    abstract::Although flow-diverting devices are promising treatment options for intracranial aneurysms, jailed side branches might occlude leading to insufficient blood supply. Especially differences in the local stent strut compression may have a drastic influence on subsequent endothelialization. To investigate the outcome of d...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.10.047

    authors: Berg P,Iosif C,Ponsonnard S,Yardin C,Janiga G,Mounayer C

    更新日期:2016-01-04 00:00:00

  • Computational analysis of flow structure and particle deposition in a single asthmatic human airway bifurcation.

    abstract::This paper aims to improve current understanding of flow structure and particle deposition in asthmatic human airways. A single, symmetric airway bifurcation, corresponding to generations 10-11 of Weibel's model, is investigated through validated numerical simulations. The parent airway segment is modelled as a smooth...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.05.031

    authors: Zhang H,Papadakis G

    更新日期:2010-09-17 00:00:00

  • Comparison of different camera calibration approaches for underwater applications.

    abstract::The purpose of this study was to compare three camera calibration approaches applied to underwater applications: (1) static control points with nonlinear DLT; (2) moving wand with nonlinear camera model and bundle adjustment; (3) moving plate with nonlinear camera model. The DVideo kinematic analysis system was used f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.01.004

    authors: Silvatti AP,Dias FA,Cerveri P,Barros RM

    更新日期:2012-04-05 00:00:00

  • External sensory-motor cues while managing unexpected slippages can violate the planar covariation law.

    abstract::This study was aimed at investigating the intersegmental coordination of six older adults while managing unexpected slippages delivered during steady walking, and wearing an Active Pelvis Orthosis (APO). The APO was setup either to assist volunteers at the hip levels during balance loss or to be transparent. The Plana...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.01.003

    authors: Aprigliano F,Monaco V,Micera S

    更新日期:2019-03-06 00:00:00

  • NLT and extrapolated DLT:3-D cinematography alternatives for enlarging the volume of calibration.

    abstract::This study investigated the accuracy of the direct linear transformation (DLT) and non-linear transformation (NLT) methods of 3-D cinematography/videography. A comparison of standard DLT, extrapolated DLT, and NLT calibrations showed the standard (non-extrapolated) DLT to be the most accurate, especially when a large ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00034-f

    authors: Hinrichs RN,McLean SP

    更新日期:1995-10-01 00:00:00

  • Material properties of articular cartilage in the rabbit tibial plateau.

    abstract::The material properties of articular cartilage in the rabbit tibial plateau were determined using biphasic indentation creep tests. Cartilage specimens from matched-pair hind limbs of rabbits approximately 4 months of age and greater than 12 months of age were tested on two locations within each compartment using a cu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.07.017

    authors: Roemhildt ML,Coughlin KM,Peura GD,Fleming BC,Beynnon BD

    更新日期:2006-01-01 00:00:00

  • On the fibre composite material models of disc annulus--comparison of predicted stresses.

    abstract::An axisymmetric finite element model of a body-disc-body unit has been developed and used to study the relative effects of two distinct direction-dependent material representations of the disc annulus on the predicted state of stresses in the disc. The annulus fibrosus is modelled either as nonhomogeneous fibre reinfo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90050-x

    authors: Shirazi-Adl A

    更新日期:1989-01-01 00:00:00

  • Specimen dimensions influence the measurement of material properties in tendon fascicles.

    abstract::Stress, strain and modulus are regularly used to characterize material properties of tissue samples. However, when comparing results from different studies it is evident the reported material properties, particularly failure strains, vary hugely. The aim of our study was to characterize how and why specimen length and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.04.040

    authors: Legerlotz K,Riley GP,Screen HR

    更新日期:2010-08-26 00:00:00

  • The effect of simulated marker misplacement on the interpretation of inter-limb differences during a change of direction task.

    abstract::The objective assessment of biomechanical asymmetries during movement tasks is used to monitor rehabilitation following anterior cruciate ligament reconstruction (ACLR). Marker placement is an important source of methodological variability within human motion analysis. It is currently unclear how marker placement erro...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110184

    authors: McFadden C,Daniels K,Strike S

    更新日期:2020-12-24 00:00:00

  • Sensitivity of dynamic simulations of gait and dynamometer experiments to hill muscle model parameters of knee flexors and extensors.

    abstract::We assessed and compared sensitivities of dynamic simulations to musculotendon (MT) parameters for gait and dynamometer experiments. Our aim with this comparison was to investigate whether dynamometer experiments could provide information about MT-parameters that are important to reliably study MT-function during gait...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.03.022

    authors: De Groote F,Van Campen A,Jonkers I,De Schutter J

    更新日期:2010-07-20 00:00:00

  • Estimating the gravity induced three dimensional deformation of the breast.

    abstract::As human breast tissue is continuously deformed by gravity, it is difficult to identify the non-loaded neutral breast position from which to take measurements. To estimate the neutral nipple position, this study proposed a simple novel method to counteract the three dimensional effect of gravity on the breast using th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.10.012

    authors: Mills C,Sanchez A,Scurr J

    更新日期:2016-12-08 00:00:00

  • Falls resulting from a laboratory-induced slip occur at a higher rate among individuals who are obese.

    abstract::Falls due to slipping are a serious concern, with slipping estimated to cause 40-50% of all fall-related injuries. Epidemiological data indicates that older and obese adults experience more falls than young, non-obese individuals. An increasingly heavier and older U.S. population and workforce may be exacerbating the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.01.018

    authors: Allin LJ,Wu X,Nussbaum MA,Madigan ML

    更新日期:2016-03-21 00:00:00

  • Stance and swing phase detection during level and slope walking in the cat: effects of slope, injury, subject and kinematic detection method.

    abstract::In quadrupeds, there have been limited comparisons of gait timing events detection (e.g., paw contact, PC and paw-off, PO) determined from kinematics and forceplates. The goal of this study was to investigate the effect of different slopes (0, -27, +27°), recovery times after ankle extensor nerve injury and repair (2,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.03.013

    authors: Pantall A,Gregor RJ,Prilutsky BI

    更新日期:2012-05-11 00:00:00

  • Modeling methodology for defining a priori the hydrodynamics of a dynamic suspension bioreactor. Application to human induced pluripotent stem cell culture.

    abstract::Three-dimensional dynamic suspension is becoming an effective cell culture method for a wide range of bioprocesses, with an increasing number of bioreactors proposed for this purpose. The complex hydrodynamics establishing within these devices affects bioprocess outcomes and efficiency, and usually expensive in vitro ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.07.021

    authors: Isu G,Morbiducci U,De Nisco G,Kropp C,Marsano A,Deriu MA,Zweigerdt R,Audenino A,Massai D

    更新日期:2019-09-20 00:00:00

  • A piecewise mass-spring-damper model of the human breast.

    abstract::Previous models to predict breast movement whilst performing physical activities have, erroneously, assumed uniform elasticity within the breast. Consequently, the predicted displacements have not yet been satisfactorily validated. In this study, real time motion capture of the natural vibrations of a breast that foll...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.11.027

    authors: Cai Y,Chen L,Yu W,Zhou J,Wan F,Suh M,Chow DH

    更新日期:2018-01-23 00:00:00

  • The effect of interfacial parameters on cup-bone relative micromotions. A finite element investigation.

    abstract::Achieving stability is a prerequisite for allowing bone to grow into the porous surface of non-cemented acetabular cups. The purpose of this study is to estimate the effects of interfacial characteristics on relative cyclical micromotion between cup and bone during gait in the immediate postoperative phase. The techni...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00112-3

    authors: Spears IR,Pfleiderer M,Schneider E,Hille E,Morlock MM

    更新日期:2001-01-01 00:00:00

  • Finding and defining the ideal patellar resection plane in total knee arthroplasty.

    abstract::Asymmetric resection of the patella during total knee arthroplasty (TKA) correlates with anterior knee pain, bony impingement and patellar maltracking. Despite this, there is no consensus regarding the desired landmarks; the cut is often done freehand; and there has been no quantitative comparison of proposed resectio...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2009.06.021

    authors: Anglin C,Fu C,Hodgson AJ,Helmy N,Greidanus NV,Masri BA

    更新日期:2009-10-16 00:00:00

  • Cellular mechanobiology of the intervertebral disc: new directions and approaches.

    abstract::The more we learn about the intervertebral disc (IVD), the more we come to appreciate the intricacies involved in transmission of forces through the ECM to the cell, and in the biological determinants of its response to mechanical stress. This review highlights recent developments in our knowledge of IVD physiology an...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2009.09.019

    authors: Hsieh AH,Twomey JD

    更新日期:2010-01-05 00:00:00

  • A computer-controlled mechanical culture system for biological testing of articular cartilage explants.

    abstract::A computer-controlled mechanical culture system was designed to investigate the interaction between mechanical stimuli and the metabolism of articular cartilage. The main features of this system include the following capabilities: (1) Accurately controlled static, permanent cyclic or intermittent cyclic mechanical loa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00040-7

    authors: Steinmeyer J

    更新日期:1997-08-01 00:00:00

  • The influence of material property and morphological parameters on specimen-specific finite element models of porcine vertebral bodies.

    abstract::The use of finite element (FE) methods in spinal research is increasing, but there is only limited information available on the influence of different input parameters on the model predictions. The aim of this study was to investigate the role of these parameters in FE models of the vertebral body. Experimental tests ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.02.005

    authors: Wilcox RK

    更新日期:2007-01-01 00:00:00

  • A comparison of methods to quantify control of the spine.

    abstract::Low back pain (LBP) affects many individuals worldwide. The established association between LBP and spine motor control has led to the development of many control assessment techniques. To understand spine control and LBP, it is essential to know the relationship between assessment techniques. Systems identification (...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109344

    authors: Bourdon E,Graham RB,van Diëen J

    更新日期:2019-11-11 00:00:00

  • Design of next generation total disk replacements.

    abstract::To improve the treatments for low back pain, new designs of total disk replacement have been proposed. The question is how well these designs can act as a functional replacement of the intervertebral disk. Four finite element models were made, for four different design concepts, to determine how well they can mimic th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.09.017

    authors: van den Broek PR,Huyghe JM,Wilson W,Ito K

    更新日期:2012-01-03 00:00:00

  • Resonant frequencies of arms and legs identify different walking patterns.

    abstract::The present study is aimed at investigating changes in the coordination of arm and leg movements in young healthy subjects. It was hypothesized that with changes in walking velocity there is a change in frequency and phase coupling between the arms and the legs. In addition, it was hypothesized that the preferred freq...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00020-8

    authors: Wagenaar RC,van Emmerik RE

    更新日期:2000-07-01 00:00:00

  • Virtually optimized insoles for offloading the diabetic foot: A randomized crossover study.

    abstract::Integration of objective biomechanical measures of foot function into the design process for insoles has been shown to provide enhanced plantar tissue protection for individuals at-risk of plantar ulceration. The use of virtual simulations utilizing numerical modeling techniques offers a potential approach to further ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.jbiomech.2017.06.028

    authors: Telfer S,Woodburn J,Collier A,Cavanagh PR

    更新日期:2017-07-26 00:00:00

  • The influence of mechanical stimulus on the pattern of tissue differentiation in a long bone fracture--an FEM study.

    abstract::2D, coronal plane, finite elements models (FEMs) were developed from orthogonal radiographs of a diaphyseal tibial fracture and its reparative tissue at four different time points during healing. Each callus was separated into regions of common tissue histology by computerised radiographic analysis. Starting point val...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00189-x

    authors: Gardner TN,Stoll T,Marks L,Mishra S,Knothe Tate M

    更新日期:2000-04-01 00:00:00

  • Elbow and wrist joint contact forces during occupational pick and place activities.

    abstract::A three-dimensional, mathematical model of the elbow and wrist joints, including 15 muscle units, 3 ligaments and 4 joint forces, has been developed. A new strain gauge transducer has been developed to measure functional grip forces. The device measures radial forces divided into six components and forces of up to 250...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00184-0

    authors: Chadwick EK,Nicol AC

    更新日期:2000-05-01 00:00:00

  • In-vivo analysis of sliding distance and cross-shear in Bi-cruciate retaining total knee arthroplasty.

    abstract::Polyethylene remains the most popular bearing material for total knee arthroplasty (TKA). Despite its widespread use, wear continue to be one of major factors implicated in revision surgery. Sliding distance, cross-shear, and contact stress are the major factors influencing polyethylene wear. As previous studies have ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.06.009

    authors: Arauz P,Peng Y,An S,Kwon YM

    更新日期:2018-08-22 00:00:00