Abstract:
:Several motion capture methods exist for predicting hip joint centers (HJC). These methods include regression models, functional joints, and projections from greater trochanters. While regression and functional methods have been compared to imaging techniques, the TROCH method has not been previously validated. The purpose of this study was to compare frontal-plane HJCs and knee mechanical axis angles estimated using the greater trochanter method with a regression (Bell) and a functional method against those obtained using radiographs. Thirty-five participants underwent a long-standing anteroposterior radiograph, and performed static and functional motion capture trials. The Bell, functional, and trochanter HJCs were constructed to predict mechanical axes and compare HJC locations. One-way repeated measures ANOVAs were used to compare mechanical axes and HJC locations estimated by motion capture methods and measured using radiographs (p<0.05). All methods overestimated mechanical axes compared to radiographs (<2°), but were not different. Mediolateral HJC locations and inter-HJC widths were similar between methods; however, inter-HJC widths were underestimated (average 3.7%) compared to radiographs. The Bell HJC was more superior and anterior to both functional and trochanter methods. The trochanter HJC was more posterior to both methods. The Bell method outperformed the other methods in leg length predictions compared to radiographs. Although differences existed between methods, all frontal-plane HJC location differences were <1.7cm. This study validated the trochanter HJC prediction method mediolaterally and vertically (with small respective correction factors). Therefore, all HJC methods seem to be viable in predicting mechanical axes and frontal-plane HJC locations compared with radiographs.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Bennett HJ,Shen G,Weinhandl JT,Zhang Sdoi
10.1016/j.jbiomech.2016.06.013subject
Has Abstractpub_date
2016-09-06 00:00:00pages
3047-3051issue
13eissn
0021-9290issn
1873-2380pii
S0021-9290(16)30679-0journal_volume
49pub_type
杂志文章abstract::A mathematical model of synovial film filtration and synovial gel formation at normal approach of cartilage surfaces in the human hip joint is presented. The biphasic mixture model presented in Part I of this paper [Hlavácek, J. Biomechanics 26, (1993)] for synovial fluid and that of Mow and his collaborators [J. Biom...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(93)90063-k
更新日期:1993-10-01 00:00:00
abstract::The aim of this study was to investigate whether elimination of multifidus muscle in rats causes intervertebral disc (IVD) degeneration similar to that found after IVD lesion. Data were obtained from 36 male Wistar rats randomly assigned to one of three groups: (i) IVD lesion, in which the L4/L5 IVD was stabbed; (ii) ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.01.004
更新日期:2018-03-21 00:00:00
abstract::The purpose of this study was to provide a quantitative description of residual femur motion within the socket during gait and to explore the relationship between residual femur motion and patient-reported comfort and function. It was hypothesized that increased residual bone movement would correlate to worse patient-...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.110050
更新日期:2020-11-09 00:00:00
abstract::Coronary artery disease results in blockages or narrowing of the artery lumen. Drug eluting stents (DES) were developed to replace bare metal stents in an effort to combat re-blocking of the diseased artery following treatment. The numerical models developed within this study focus on representing the changing trends ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.09.017
更新日期:2014-01-03 00:00:00
abstract::In this study, a theoretical framework for simulation of fracture of bone and bone-like materials is provided. An expanded cohesive zone model with thermodynamically consistent framework has been proposed and used to investigate the crack growth resistance of bone and bone-like materials. The reversible elastic deform...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.04.054
更新日期:2014-07-18 00:00:00
abstract::The accurate assessment of the Achilles tendon cross-sectional area (CSA) is a crucial prerequisite to investigate tendon adaptation and to calculate the tendon Young׳s modulus. Besides magnetic resonance imaging (MRI), ultrasonography emerged as an alternative imaging technique. The purpose of the present study was t...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.07.002
更新日期:2016-09-06 00:00:00
abstract::The study verifies the development of active axial stress in the wall of mouse aorta over a range of physiological loads when the smooth muscle cells are stimulated to contract. The results obtained show that the active axial stress is virtually independent of the magnitude of pressure, but depends predominately on th...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2012.05.025
更新日期:2012-07-26 00:00:00
abstract::Gait analysis is a quantitative, non-invasive technique that can be used to investigate functional changes in animal models of musculoskeletal disease. Changes in ground reaction forces following injury have been observed that coincide with differences in tissue mechanical and histological properties during healing. H...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.12.027
更新日期:2016-02-08 00:00:00
abstract::Valgus moments on the knee joint during single-leg landing have been suggested as a risk factor for anterior cruciate ligament (ACL) injury. The purpose of this study was to test the influence of isolated valgus moment on ACL strain during single-leg landing. Physiologic levels of valgus moments from an in vivo study ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.10.031
更新日期:2009-02-09 00:00:00
abstract::Postural impairment due to neuro-degenerative disorders such as Parkinson's Disease (PD) leads to restricted gait patterns, fall-related injuries, decreased mobility, and loss of functional independence. Though several clinical and posturographic studies have attempted to reveal the complex pathophysiology involved in...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109791
更新日期:2020-05-22 00:00:00
abstract::Fibroblasts in intact tendons align with stretching direction, but they tend to orient randomly in healing tendons. Therefore, a question arises: Do fibroblast responses to mechanical stretching depend on their orientation? To address this question, human patellar tendon fibroblasts were grown in custom-made silicone ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2003.09.011
更新日期:2004-04-01 00:00:00
abstract::Prosthetic heart valves deployed in the left heart (aortic and mitral) are subjected to harsh hemodynamical conditions. Most of the tissue engineered heart valves have been developed for the low pressure pulmonary position because of the difficulties in fabricating a mechanically strong valve, able to withstand the sy...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.07.018
更新日期:2018-09-10 00:00:00
abstract::Controlling dynamic interactions between the lower limb and ground is important for skilled locomotion and may influence injury risk in athletes. It is well known that female athletes sustain anterior cruciate ligament (ACL) tears at higher rates than male athletes, and exhibit lower extremity biomechanics thought to ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.10.038
更新日期:2014-01-22 00:00:00
abstract::Hip joint dislocations related to total hip arthroplasty (THA) are a common complication especially in the early postoperative course. The surgical approach, the alignment of the prosthetic components, the range of motion and the muscle tone are known factors influencing the risk of dislocation. A further factor that ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.05.013
更新日期:2014-08-22 00:00:00
abstract::The pleural surfaces of the chest wall and lung slide against each other, lubricated by pleural fluid. During sliding motion of soft tissues, shear induced hydrodynamic pressure deforms the surfaces, promoting uniformity of the fluid layer thickness, thereby reducing friction. To assess pleural deformability at length...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.07.008
更新日期:2011-09-23 00:00:00
abstract::Recent first attempts of in situ ultrasound strain imaging in collateral ligaments encountered a number of challenges and illustrated a clear need for additional studies and more thorough validation of the available strain imaging methods. Therefore, in this study we experimentally validated ultrasound strain measurem...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.03.035
更新日期:2018-05-17 00:00:00
abstract::A clinical strength MRI and intact bovine caudal intervertebral discs were used to test the hypotheses that (1) mechanical loading and trypsin treatment induce changes in NMR parameters, mechanical properties and biochemical contents; and (2) mechanical properties are quantitatively related to NMR parameters. MRI acqu...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.04.015
更新日期:2006-01-01 00:00:00
abstract::Although a significant proportion of patient falls occur during egress from the hospital bed, the biomechanical adaptations during egress from different bed heights are still largely unknown. The purpose of this study was to evaluate the effect of hospital bed height on natural transition during egress in patients wit...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.110116
更新日期:2021-01-22 00:00:00
abstract::Three-dimensional gait analysis (3D-GA) is commonly used to answer clinical questions of the form "which joints and what variables are most affected during when". When studying high-dimensional datasets, traditional dimension reduction methods (e.g. principal components analysis) require "data flattening", which may m...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.04.035
更新日期:2019-06-11 00:00:00
abstract::Cultured cells subjected to fluid flow are exposed to mechanical forces and electrokinetic forces. The convective current establishes an electrokinetic force created by the flow-dependent transport of mobile ions in the media over the charged cell surfaces. This current can be expressed as a current density, the curre...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(96)84535-0
更新日期:1996-11-01 00:00:00
abstract::Experiments were performed to study biaxial anisotropy in relaxed canine carotid arteries subjected to a wide range of longitudinal lengths and transmural pressures. In order to encompass the range of vessel lengths which occurs in situ, 120 carotid arteries were studied at 20%, 40%, 60% and 80% extension relative to ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(86)90011-4
更新日期:1986-01-01 00:00:00
abstract::The surface roughness of a bone implant was defined parametrically. The values of the parameters defining the surface were varied. Some traditionally used surface roughness parameters were calculated. By means of a theoretical model the bone-implant interfacial shear strength was estimated. No simple correlation betwe...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(00)00045-2
更新日期:2000-10-01 00:00:00
abstract::In attempts to better understand the etiology of osteoarthritis, a debilitating joint disease that results in the degeneration of articular cartilage (AC) in synovial joints, researchers have focused on joint tribology, the study of joint friction, lubrication, and wear. Several different approaches have been used to ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.05.024
更新日期:2009-08-25 00:00:00
abstract::Current MR methods use T2(*) relaxation time as a surrogate measure of ligament strength. Currently, a multi-echo voxel-wise least squares fit is the gold standard to create T2(*) maps; however, the post-processing is time-intensive and serves as a stopgap for clinical use. The study objective was to determine if an a...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.03.037
更新日期:2014-07-18 00:00:00
abstract::During respiration, upper airway (UA) collapse occurs when the forces generated from the negative UA pressures exceed the forces produced by the UA muscles; which leads to loose soft tissue at the back of the mouth. At predetermined titration pressure, the Continuous Positive Airway Pressure (CPAP) normally provides a...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.11.005
更新日期:2016-12-08 00:00:00
abstract::A non-invasive, in vivo method has been developed to predict the skin flap shrinkage (retraction) following a harvest. It involves the use of a novel custom-designed extensometer to measure the force-displacement behaviour of skin and subsequent data analysis to estimate the shrinkage. In validation experiments perfor...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.03.012
更新日期:2008-01-01 00:00:00
abstract::A three-dimensional, mathematical model of the elbow and wrist joints, including 15 muscle units, 3 ligaments and 4 joint forces, has been developed. A new strain gauge transducer has been developed to measure functional grip forces. The device measures radial forces divided into six components and forces of up to 250...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(99)00184-0
更新日期:2000-05-01 00:00:00
abstract::It is thought that the magnitude of residual force enhancement (RFE) is not affected by stretch velocity. However, the range of stretch velocities studied in previous investigations has been limited to slow and moderate velocities. High velocities of muscle stretching are associated with a loss of force and incomplete...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.04.033
更新日期:2019-05-24 00:00:00
abstract::A fast (0.1 mm steps within 2 ms), strong (40 N continuously) and accurate (resolution 0.002 N and 1.0 micron) muscle ergometer was developed to test dynamic and static properties of mammalian muscle. Both for twitches and for tetani isometric, isokinetic and isotonic contractions can be measured accurately. Force-vel...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(87)90312-5
更新日期:1987-01-01 00:00:00
abstract::Humans control their movements using adaptive proprioceptive feedback from muscle afferents. The interaction between proprioceptive reflexes and biomechanical properties of the limb is essential in understanding the etiology of movement disorders. A non-linear neuromuscular model of the wrist incorporating muscle dyna...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.09.024
更新日期:2012-01-03 00:00:00