Abstract:
:Inertial measurement units (IMUs) offer great opportunities to analyze segmental and joints kinematics. When combined with another motion capture system (MCS), for example, to validate new IMU-based applications or to develop mixed systems, it is necessary to align the local frame of the IMU sensors to the local frame of the MCS. Currently, all alignment methods use landmarks on the IMU's casing. Therefore, they can only be used with well-documented IMUs and they are prone to error when the IMU's casing is small. This study proposes an effortless procedure to align the local frame of any IMU to the local frame of any other MCS able to measure the orientation of its local frame. The general concept of this method is to derive the gyroscopic angles for both devices during an alignment movement, and then to use an optimization algorithm to calculate the alignment matrix between both local frames. The alignment movement consists of rotations around three more or less orthogonal axes and it can easily be performed by hands. To test the alignment procedure, an IMU and a magnetic marker were attached to a plate, and 20 alignment movements were recorded. The maximum errors of alignment (accuracy±precision) were 1.02°±0.32° and simulations showed that the method was robust against noise that typically affect IMUs. In conclusion, this study describes an efficient alignment procedure that is quick and easy to perform, and that does not require any alignment device or any knowledge about the IMU casing.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Chardonnens J,Favre J,Aminian Kdoi
10.1016/j.jbiomech.2012.06.009subject
Has Abstractpub_date
2012-08-31 00:00:00pages
2297-300issue
13eissn
0021-9290issn
1873-2380pii
S0021-9290(12)00341-7journal_volume
45pub_type
杂志文章abstract::Histological investigation along with finite element analysis of arterial wall/atherosclerotic plaque geometries indicates the paradoxical result that ruptures often occur at sites with predicted stresses of half the plaque cap strength. Recent experiments have revealed calcified cells within the cap suggesting that t...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.06.012
更新日期:2010-10-19 00:00:00
abstract::The role played by macrophage migration inhibitory factor (MIF) in the process of wound healing is controversial. Besides, there have been no reports that investigated the expression or the role of MIF in the repair process after ligament injury. In this study, we hypothesized that the deficiency in MIF gene might del...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.09.018
更新日期:2011-02-03 00:00:00
abstract::Propulsive forces generated by swimmers hand/forearm, have been studied through experimental tests. However, there are serious doubts as to whether forces quantified in this way are accurate enough to be meaningful. In order to solve some experimental problems, some numerical techniques have been proposed using Comput...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.03.012
更新日期:2006-01-01 00:00:00
abstract::This paper has three purposes. (1) To verify an error formula from which the maximal precision in derivatives obtained from noisy measurement data can be calculated. The formula is verified by comparison with the resulting noise in derivatives obtained by local least squares polynomial fitting. It is also verified tha...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(82)90082-3
更新日期:1982-01-01 00:00:00
abstract::Morphometrical and postural features of the cervical spine are supposed to significantly influence its biomechanical behaviour. However, the effects of these geometrical parameters are quite difficult to evaluate. An original numerical method is proposed in order to automatically generate parametric and subject-specif...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.04.007
更新日期:2009-07-22 00:00:00
abstract::Kinesin is a microtubule-based motor protein that generates motion involved in intracellular trafficking and cell division. Even if the force-generating and enzymatic properties of kinesin were extensively studied, the molecular basis of its interaction with the microtubule is still not well understood. The aim of the...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.08.014
更新日期:2008-11-14 00:00:00
abstract::The critical role that mechanical stimuli serve in mediating bone repair is recognized but incompletely understood. Further, previous attempts to understand this role have utilized application of externally applied mechanical loads to study the tissue's response. In this project, we have therefore endeavored to capita...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.06.030
更新日期:2010-10-19 00:00:00
abstract::This paper presents a general method for simulating the movement of the lower extremity during human walking. It is based upon two separate algorithms: one for single support (an open kinematic chain), and the other for the double support phase (a closed-loop linkage). Central to each of these is the recursive Newton-...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(88)90250-3
更新日期:1988-01-01 00:00:00
abstract::In this study, a three-dimensional finite element model was used to investigate the changes in tissue composition and mechanical signals within human lumbar intervertebral disc during the degenerative progression. This model was developed based on the cell-activity coupled mechano-electrochemical mixture theory. The d...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.09.004
更新日期:2014-11-28 00:00:00
abstract::This study presents an anatomically customizable fixation technique for biomechanical spine experiments using a 3D printed clamping system. The aim of this study is to evaluate the feasibility and compare the fixation rigidity of the novel technique to PMMA potting with and without screw augmentation. For this purpose...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.109467
更新日期:2020-01-02 00:00:00
abstract::Understanding microstructural changes that occur in skin subjected to repetitive mechanical stress is crucial towards the development of therapies to enhance skin adaptation and load tolerance in patients at risk of skin breakdown (e.g. prosthesis users, wheelchair users). To determine if collagen fibril diameter, col...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(01)00145-2
更新日期:2001-12-01 00:00:00
abstract::The movements of the human jaw are controlled by the forces produced by the masticatory muscles. As the jaw moves, these muscles change in length and their force producing units, the sarcomeres, change in length simultaneously. The lengths and length changes of the sarcomeres are determinants for the forces they are a...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(97)00047-x
更新日期:1997-09-01 00:00:00
abstract::Multiscale models of cortical bone elasticity require a large number of parameters to describe the organization and composition of the tissue. We hypothesize that the macro-scale anisotropic elastic properties of different bones can be modeled retaining only two variable parameters, and setting the others to universal...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.03.006
更新日期:2011-05-17 00:00:00
abstract::Baropodometry and multi-segmental foot kinematics are frequently employed to obtain insight into the mechanics of the foot-ground interaction in both basic research and clinical settings. However, nothing hitherto has been reported on the full integration of kinematics with baropodometric parameters, and only a few st...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.05.014
更新日期:2014-08-22 00:00:00
abstract::The purpose of this project was to study a noninvasive method of evaluating limbs at risk of compartment syndrome. Untreated limb compartment syndrome may lead to irreversible dysfunction, chronic pain and contracture. An improved means of obtaining quantitative hardness measurements is reported. The handheld noninvas...
journal_title:Journal of biomechanics
pub_type: 临床试验,杂志文章
doi:10.1016/j.jbiomech.2004.07.030
更新日期:2005-08-01 00:00:00
abstract::Glaucoma is a common cause of blindness. Studies of this disease can involve collection of aqueous humor (AH) fluid from eyes of patients undergoing surgery, which involves aspirating a small fluid volume from the anterior region of the eye through a fine-bore needle. Unfortunately, the composition of the AH is spatia...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.07.025
更新日期:2009-11-13 00:00:00
abstract::This contribution is concerned with the modelling of PMMA-based bone cement polymerisation process and the associated heat effect. While existing models use description in terms of the so-called polymerisation fraction to fit the experimental data, the new model is constructed in such a way as to mimic the chemical pr...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.06.021
更新日期:2005-07-01 00:00:00
abstract::An axisymmetric finite element model of a body-disc-body unit has been developed and used to study the relative effects of two distinct direction-dependent material representations of the disc annulus on the predicted state of stresses in the disc. The annulus fibrosus is modelled either as nonhomogeneous fibre reinfo...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(89)90050-x
更新日期:1989-01-01 00:00:00
abstract::This work proposes a real-time monitoring tool aimed to support clinicians for remote assessing exercise performances during home-based rehabilitation. The study relies on clinician indications to define kinematic features, that describe five motor tasks (i.e., the lateral tilt of the trunk, lifting of the arms, trunk...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.01.008
更新日期:2018-03-01 00:00:00
abstract::Muscle force is modulated by varying the number of active motor units and their firing rates. For the past five decades, the notion that the magnitude of the firing rates is directly related to motor unit size and recruitment threshold has been widely accepted. This construct, here named the After-hyperpolarization sc...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.12.003
更新日期:2015-01-21 00:00:00
abstract::When recovering balance from a lateral perturbation, younger adults tend to stabilize balance with a single lateral sidestep while older adults often take multistep responses. Using multiple steps to recover balance is consistently associated with increased fall risk, altered body center of mass (CoM) control and inst...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.110161
更新日期:2021-01-04 00:00:00
abstract::The literature contains many measurements of the fatigue properties of compact bone, but these experimental results have been difficult to interpret and use due to a large amount of apparent scatter: variation in the number of cycles to failure for a given cyclic stress or strain range. Recently Taylor (1998a, Journal...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(99)00112-8
更新日期:1999-11-01 00:00:00
abstract::Tendons are elastic structures that connect muscle to the skeletal system and transmit force relative to the amount of stretch they experience. The mechanical properties of human tendons are difficult to measure non-invasively, so generic values are often assumed in musculoskeletal models to represent all subjects. We...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.06.009
更新日期:2015-09-18 00:00:00
abstract::The importance of the aortic root compliance in the aortic valve performance has most frequently been ignored in computational valve modeling, although it has a significant contribution to the functionality of the valve. Aortic root aneurysm or (calcific) stiffening severely affects the aortic valve behavior and, cons...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(02)00448-7
更新日期:2003-05-01 00:00:00
abstract::The aim of this study was to obtain insight into the coactivation behaviour of the jaw muscles under various a priori defined static loading conditions of the mandible. As the masticatory system is mechanically redundant, an infinite number of recruitment patterns is theoretically possible to produce a certain bite fo...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(90)90303-k
更新日期:1990-01-01 00:00:00
abstract::Although biomechanical studies of the normal rat vein wall have been reported (Weizsacker, 1988; Plante, 2002), there are no published studies that have investigated the mechanical effects of thrombus formation on murine venous tissue. In response to the lack of knowledge concerning the mechanical consequences of thro...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.07.012
更新日期:2010-11-16 00:00:00
abstract::The present article investigates the influence of center-of-mass movements on the variation of the structure in human postural sway. Twelve healthy younger persons performed 60s quiet standing, 60s relaxed standing, and 10 min relaxed standing on two force plates. Center-of-pressure (CoP) and gravitational line (GL) p...
journal_title:Journal of biomechanics
pub_type: 临床试验,杂志文章
doi:10.1016/j.jbiomech.2012.10.016
更新日期:2013-02-01 00:00:00
abstract::Static stretching is a major type of mechanical stimuli utilized during distraction osteogenesis (DO), a general surgical method for the lengthening of bone. The molecular signals that drive the regenerative process in DO include a variety of cytokines. Among these, bone morphogenic protein (BMP, -2 and -4) has been r...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.08.006
更新日期:2009-12-11 00:00:00
abstract::Tripping is responsible for a large percentage of falls. Minimum toe clearance (MTC) during the swing phase of gait is commonly used to infer the probability of tripping (POT). However, there is limited empirical evidence to support the relationship between these two variables, and other measures of toe trajectory may...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.10.045
更新日期:2016-12-08 00:00:00
abstract::This paper presents a three-dimensional finite element model of skeletal muscle which was developed to simulate active and passive non-linear mechanical behaviours of the muscle during lengthening or shortening under either quasi-static or dynamic condition. Constitutive relation of the muscle was determined by using ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.01.021
更新日期:2009-05-11 00:00:00