The mechanics of atherosclerotic plaque rupture by inclusion/matrix interfacial decohesion.

Abstract:

:Histological investigation along with finite element analysis of arterial wall/atherosclerotic plaque geometries indicates the paradoxical result that ruptures often occur at sites with predicted stresses of half the plaque cap strength. Recent experiments have revealed calcified cells within the cap suggesting that these inclusions, situated close to the cap/luminal blood surface, precipitate rupture at low nominal loads by concentrating stress. In this paper, we investigate the proposition that rupture at low nominal loads occurs by (possibly brittle) decohesion of the calcification/cap interface followed by tearing of cap tissue. A novel boundary value problem is analyzed consisting of a remotely loaded linear elastic layer (extracellular matrix cap) containing a rigid spherical inclusion (calcified cell) that interacts with it through a nonlinear structural interface which models the binding of the calcified cell to the extracellular matrix via integrin receptor proteins. Equilibrium solutions are obtained from equations derived from the Boussinesq potentials for spherical domains. Results indicate a brittle character to the rupture process with the size of the domains between the inclusion center and the matrix surfaces determining the concentration of stress. For an inclusion close to a surface the abrupt unloading of the interface during brittle decohesion produces a sharp spike in circumferential stress. We conjecture that when this dynamic stress exceeds the cap strength, tearing occurs followed by thrombus formation and possibly infarction.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Nguyen CM,Levy AJ

doi

10.1016/j.jbiomech.2010.06.012

subject

Has Abstract

pub_date

2010-10-19 00:00:00

pages

2702-8

issue

14

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(10)00348-9

journal_volume

43

pub_type

杂志文章
  • The behavior of adaptive bone-remodeling simulation models.

    abstract::The process of adaptive bone remodeling can be described mathematically and simulated in a computer model, integrated with the finite element method. In the model discussed here, cortical and trabecular bone are described as continuous materials with variable density. The remodeling rule applied to simulate the remode...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90056-7

    authors: Weinans H,Huiskes R,Grootenboer HJ

    更新日期:1992-12-01 00:00:00

  • Effect of boundary conditions, impact loading and hydraulic stiffening on femoral fracture strength.

    abstract::Patient specific quantitative CT (QCT) imaging data together with the finite element (FE) method may provide an accurate prediction of a patient's femoral strength and fracture risk. Although numerous FE models investigating femoral fracture strength have been published, there is little consent on the effect of bounda...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.07.004

    authors: Haider IT,Speirs AD,Frei H

    更新日期:2013-09-03 00:00:00

  • A mathematical high bar-human body model for analysing and interpreting mechanical-energetic processes on the high bar.

    abstract::The aims of this study were: 1. To study the transfer of energy between the high bar and the gymnast. 2. To develop criteria from the utilisation of high bar elasticity and the utilisation of muscle capacity to assess the effectiveness of a movement solution. 3. To study the influence of varying segment movement upon ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00134-1

    authors: Arampatzis A,Brüggemann GP

    更新日期:1998-12-01 00:00:00

  • Kinematic analysis of video-captured falls experienced by older adults in long-term care.

    abstract::Falls cause 95% of hip and wrist fractures and 60% of head injuries in older adults. Risk for such injuries depends in part on velocity at contact, and the time available during the fall to generate protective responses. However, we have no information on the impact velocities and durations of falls in older adults. W...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.025

    authors: Choi WJ,Wakeling JM,Robinovitch SN

    更新日期:2015-04-13 00:00:00

  • Which axial and bending stiffnesses of posterior implants are required to design a flexible lumbar stabilization system?

    abstract::Dynamic stabilization devices have been introduced to clinics as an alternative to rigid fixation. The stiffness of these devices varies widely, whereas the optimal stiffness, achieving a predefined stabilization of the spine, is unknown. This study was focused on the determination of stiffness values for posterior st...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.10.005

    authors: Schmidt H,Heuer F,Wilke HJ

    更新日期:2009-01-05 00:00:00

  • The influences of foot placement on lumbopelvic rhythm during trunk flexion motion.

    abstract::Different standing postures could potentially influence trunk biomechanics during task performance. The current study investigated how foot placement, especially stance width and foot angle influenced lumbopelvic rhythm during sagittal trunk flexion motion. Ten participants performed pace controlled sagittally symmetr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.048

    authors: Zhou J,Ning X,Hu B,Dai B

    更新日期:2016-06-14 00:00:00

  • Quantitative analysis of brain microstructure following mild blunt and blast trauma.

    abstract::We induced mild blunt and blast injuries in rats using a custom-built device and utilized in-house diffusion tensor imaging (DTI) software to reconstruct 3-D fiber tracts in brains before and after injury (1, 4, and 7 days). DTI measures such as fiber count, fiber length, and fractional anisotropy (FA) were selected t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.09.026

    authors: Begonia MT,Prabhu R,Liao J,Whittington WR,Claude A,Willeford B,Wardlaw J,Wu R,Zhang S,Williams LN

    更新日期:2014-11-28 00:00:00

  • Implant size and mechanical properties influence the failure of the adhesive bond between cartilage implants and native tissue in a finite element analysis.

    abstract::Implanted cartilage replacements (ICRs) are a promising approach to restore the functionality of joints with partial- and full-thickness articular cartilage lesions. Two major hurdles hindering successful repair of cartilage injuries with ICRs are their inadequate mechanical properties and fixation into the defect are...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.03.019

    authors: Vahdati A,Wagner DR

    更新日期:2013-05-31 00:00:00

  • Importance of preswing rectus femoris activity in stiff-knee gait.

    abstract::Stiff-knee gait is characterized by diminished and delayed knee flexion during swing. Rectus femoris transfer surgery, a common treatment for stiff-knee gait, is often recommended when a patient exhibits prolonged activity of the rectus femoris muscle during swing. Treatment outcomes are inconsistent, in part, due to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.05.030

    authors: Reinbolt JA,Fox MD,Arnold AS,Ounpuu S,Delp SL

    更新日期:2008-08-07 00:00:00

  • Muscle activity patterns altered during pedaling at different body orientations.

    abstract::Gravity is a contributing force that is believed to influence strongly the control of limb movements since it affects sensory input and also contributes to task mechanics. By altering the relative contribution of gravitational force to the overall forces used to control pedaling at different body orientations, we test...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)00038-3

    authors: Brown DA,Kautz SA,Dairaghi CA

    更新日期:1996-10-01 00:00:00

  • Triceps surae muscle-tendon unit length changes as a function of ankle joint angles and contraction levels: the effect of foot arch deformation.

    abstract::The purpose of this study was to clarify how foot deformation affects the relationship between triceps surae muscle-tendon unit (MTU) length and ankle joint angle. For six women and six men a series of sagittal magnetic resonance (MR) images of the right foot were taken, and changes in MTU length (the displacement of ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.07.003

    authors: Iwanuma S,Akagi R,Hashizume S,Kanehisa H,Yanai T,Kawakami Y

    更新日期:2011-09-23 00:00:00

  • Compensation for inertial and gravity effects in a moving force platform.

    abstract::Force plates for human movement analysis provide accurate measurements when mounted rigidly on an inertial reference frame. Large measurement errors occur, however, when the force plate is accelerated, or tilted relative to gravity. This prohibits the use of force plates in human perturbation studies with controlled s...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.05.009

    authors: Hnat SK,van Basten BJH,van den Bogert AJ

    更新日期:2018-06-25 00:00:00

  • Mechanical properties vary for different regions of the finger extensor apparatus.

    abstract::The extensor apparatus, an aponeurosis that covers the dorsal side of each finger, transmits force from a number of musculotendons to the phalanges. Multiple tendons integrate directly into the structure at different sites and the extensor apparatus attaches to the phalanges at multiple points. Thus, prediction of the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.06.035

    authors: Qian K,Traylor K,Lee SW,Ellis B,Weiss J,Kamper D

    更新日期:2014-09-22 00:00:00

  • Estimation of unmeasured ground reaction force data based on the oscillatory characteristics of the center of mass during human walking.

    abstract::To enhance the wearability of portable motion-monitoring devices, the size and number of sensors are minimized, but at the expense of quality and quantity of data collected. For example, owing to the size and weight of low-frequency force transducers, most currently available wearable gait measurement systems provide ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.01.046

    authors: Ryu HX,Park S

    更新日期:2018-04-11 00:00:00

  • Simulating contact using the elastic foundation algorithm in OpenSim.

    abstract::Modeling joint contact in OpenSim is not well understood. This study systematically investigated the variables associated with the elastic foundation contact model within OpenSim by performing a series of controlled benchtop experiment and concomitant simulations. Four metal-on-plastic interactions were modeled, inclu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.11.025

    authors: Hast MW,Hanson BG,Baxter JR

    更新日期:2019-01-03 00:00:00

  • Cluster-based upper body marker models for three-dimensional kinematic analysis: Comparison with an anatomical model and reliability analysis.

    abstract::Quantifying angular joint kinematics of the upper body is a useful method for assessing upper limb function. Joint angles are commonly obtained via motion capture, tracking markers placed on anatomical landmarks. This method is associated with limitations including administrative burden, soft tissue artifacts, and int...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.02.028

    authors: Boser QA,Valevicius AM,Lavoie EB,Chapman CS,Pilarski PM,Hebert JS,Vette AH

    更新日期:2018-04-27 00:00:00

  • Ligament fibre recruitment at the human ankle joint complex in passive flexion.

    abstract::Knowledge of ligament fibre recruitment at the human ankle joint complex is a fundamental prerequisite for analysing mobility and stability. Previous experimental and modelling studies have shown that ankle motion must be guided by fibres within the calcaneofibular and tibiocalcaneal ligaments, which remain approximat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.02.043

    authors: Stagni R,Leardini A,Ensini A

    更新日期:2004-12-01 00:00:00

  • Dynamic shear behavior of mandibular condylar cartilage is dependent on testing direction.

    abstract::Little information is available on the direction-dependency of shear behavior in mandibular condylar cartilage. Therefore, we tested the hypothesis that such a dependency of the dynamic shear properties is present in mandibular condylar cartilage. From each of 17 condyles, two cartilage-bone plugs were dissected and t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.12.012

    authors: Tanaka E,Iwabuchi Y,Rego EB,Koolstra JH,Yamano E,Hasegawa T,Kawazoe A,Kawai N,Tanne K

    更新日期:2008-01-01 00:00:00

  • Three-dimensional finite element analysis of glass-ceramic dental crowns.

    abstract::Because of the improved esthetic potential of glass-ceramic crowns as dental restorations, they are sometimes preferred over metal-ceramic crowns for restoration of anterior teeth. Because of their relatively high strength, these ceramic crowns are also frequently used for restoration of posterior teeth. However, due ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90008-q

    authors: Hojjatie B,Anusavice KJ

    更新日期:1990-01-01 00:00:00

  • Skewness angle of interfibrillar proteoglycans increases with applied load on mitral valve chordae tendineae.

    abstract::In highly aligned connective tissues, such as tendon, collagen fibrils are linked together by proteoglycans (PGs). Recent mechanical and theoretical studies on tendon micromechanics have implied that PGs mediate mechanical interactions between adjacent collagen fibrils. We used transmission electron microscopy to obse...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.12.011

    authors: Liao J,Vesely I

    更新日期:2007-01-01 00:00:00

  • Different methods to estimate total power and its components during lifting.

    abstract::A more fundamental understanding about the act of manual lifting can be provided by the assessment of the total production of power and the power generated in joints. The present study is concerned with the validity of the estimations of these parameters. Four subjects lifted an 18.8 kg load while they were filmed and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90045-3

    authors: de Looze MP,Bussmann JB,Kingma I,Toussaint HM

    更新日期:1992-09-01 00:00:00

  • Three-dimensional measurement of proximal radioulnar space during active forearm pronation.

    abstract::Distal biceps tendon ruptures have been reported to be associated with narrowing of the proximal radioulnar space. There have been no studies that three-dimensionally measured the distance between the bicipital tuberosity and the proximal ulna during active motion. The purpose of this study was to three-dimensionally ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110120

    authors: Matsuki K,Sugaya H,Takahashi N,Tokai M,Ueda Y,Hoshika S,Hamada H,Banks SA

    更新日期:2020-12-02 00:00:00

  • Probing softness of the parietal pleural surface at the micron scale.

    abstract::The pleural surfaces of the chest wall and lung slide against each other, lubricated by pleural fluid. During sliding motion of soft tissues, shear induced hydrodynamic pressure deforms the surfaces, promoting uniformity of the fluid layer thickness, thereby reducing friction. To assess pleural deformability at length...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.07.008

    authors: Kim JH,Butler JP,Loring SH

    更新日期:2011-09-23 00:00:00

  • Concurrent validity and reliability of a mobile tracking technology to measure angular and linear movements of the neck.

    abstract::The neck can be moved in six degrees of freedom. Current 3D-optoelectronic motion-capture systems capable of measuring these movements are inappropriate for use in clinical practice because they are stationary, expensive and time-consuming. We therefore developed a less complex 3D-tracking technology based on Steam®VR...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109340

    authors: Sommer BB,Weisenhorn M,Ernst MJ,Meichtry A,Rast FM,Kleger D,Schmid P,Lünenburger L,Bauer CM

    更新日期:2019-11-11 00:00:00

  • Modeling methodology for defining a priori the hydrodynamics of a dynamic suspension bioreactor. Application to human induced pluripotent stem cell culture.

    abstract::Three-dimensional dynamic suspension is becoming an effective cell culture method for a wide range of bioprocesses, with an increasing number of bioreactors proposed for this purpose. The complex hydrodynamics establishing within these devices affects bioprocess outcomes and efficiency, and usually expensive in vitro ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.07.021

    authors: Isu G,Morbiducci U,De Nisco G,Kropp C,Marsano A,Deriu MA,Zweigerdt R,Audenino A,Massai D

    更新日期:2019-09-20 00:00:00

  • The exoskeletal structure and tensile loading behavior of an ant neck joint.

    abstract::Insects have evolved mechanical form and function over millions of years. Ants, in particular, can lift and carry heavy loads relative to their body mass. Loads are lifted with the mouthparts, transferred through the neck joint to the thorax, and distributed over six legs and tarsi (feet) that anchor to the supporting...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.10.053

    authors: Nguyen V,Lilly B,Castro C

    更新日期:2014-01-22 00:00:00

  • Non-Newtonian blood flow in human right coronary arteries: transient simulations.

    abstract::This study looks at pulsatile blood flow through four different right coronary arteries, which have been reconstructed from biplane angiograms. A non-Newtonian blood model (the Generalised Power Law), as well as the usual Newtonian model of blood viscosity, is used to study the wall shear stress in each of these arter...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.01.034

    authors: Johnston BM,Johnston PR,Corney S,Kilpatrick D

    更新日期:2006-01-01 00:00:00

  • Muscle fatigue does not lead to increased instability of upper extremity repetitive movements.

    abstract::Muscle fatigue alters neuromuscular responses. This may lead to increased sensitivity to perturbations and possibly to subsequent injury risk. We studied the effects of muscle fatigue on movement stability during a repetitive upper extremity task. Twenty healthy young subjects performed a repetitive work task, similar...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.11.001

    authors: Gates DH,Dingwell JB

    更新日期:2010-03-22 00:00:00

  • Relationships between femoral fracture loads for two load configurations.

    abstract::Studies of proximal femoral strength usually involve one of two types of loading conditions, loading similar to joint loading during single-limb stance or loading simulating impact from a fall. When interpreting the results of studies involving only one of these load configurations, the question arises as to their app...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00202-x

    authors: Keyak JH

    更新日期:2000-04-01 00:00:00

  • Non-interacting modes for stress, strain and energy in anisotropic hard tissue.

    abstract::The six non-interacting modes for stress, strain and energy in an orthotropic elastic model of human femoral cortical bone tissue are discussed and illustrated. The stress and strain modes are illustrated using the representation of the stress and strain fields around a circular hole in a flat plate of cortical bone s...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90311-a

    authors: Cowin SC,Sadegh AM

    更新日期:1991-01-01 00:00:00