Implant size and mechanical properties influence the failure of the adhesive bond between cartilage implants and native tissue in a finite element analysis.

Abstract:

:Implanted cartilage replacements (ICRs) are a promising approach to restore the functionality of joints with partial- and full-thickness articular cartilage lesions. Two major hurdles hindering successful repair of cartilage injuries with ICRs are their inadequate mechanical properties and fixation into the defect area. While the ICR geometry and mechanical properties are expected to affect the loads and deformations at the adhesive interface between the implant and native cartilage, little is known about the relationship between these implant characteristics and the quality of the fixation. The objective of this study was to evaluate the effect of implant size, thickness, modulus, surface coefficient of friction and Poisson's ratio on the failure of a fibrin adhesive interface. These factors were evaluated in an idealized finite element model of the medial compartment of the human knee with the damage and failure of fibrin at the implant/cartilage interface represented by a cohesive zone model. Both axial compression and sliding were included in the loading conditions. The results demonstrated that ICR size and material properties have a significant effect on the failure of the fibrin that adheres the implant to the native tissue. Lack of anchorage to underlying bone, larger implant sizes, higher surface coefficient of friction and higher compliance of the implant can increase the chance of implant loosening and delamination. In the future, these results may guide implant design and cartilage repair techniques.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Vahdati A,Wagner DR

doi

10.1016/j.jbiomech.2013.03.019

subject

Has Abstract

pub_date

2013-05-31 00:00:00

pages

1554-60

issue

9

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(13)00135-8

journal_volume

46

pub_type

杂志文章
  • Hemodynamic effects of pulsatile unloading of left ventricular assist devices (LVAD) on intraventricular flow and ventricular stress.

    abstract::The role of pulsatile unloading in hemodynamic changes in intraventricular flow and ventricular wall stress remains unknown. In this study, a finite element model of the left ventricle (LV) is proposed to calculate the mechanical response. The constitutive model of the LV is composed of a quasi-incompressible transver...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109425

    authors: Gu K,Guan Z,Chang Y,Gao B,Ling Y,Song Z,Wan F

    更新日期:2020-04-16 00:00:00

  • The flexural rigidity of the aortic valve leaflet in the commissural region.

    abstract::Flexure is a major deformation mode of the aortic valve (AV) leaflet, particularly in the commissural region where the upper portion of the leaflet joins the aortic root. However, there are no existing data known on the mechanical properties of leaflet in the commissural region. To address this issue, we quantified th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.10.026

    authors: Mirnajafi A,Raymer JM,McClure LR,Sacks MS

    更新日期:2006-01-01 00:00:00

  • Reliability of upper and lower extremity anthropometric measurements and the effect on tissue mass predictions.

    abstract::Accurate modeling of soft tissue motion effects relative to bone during impact requires knowledge of the mass of soft and rigid tissues in living people. Holmes et al., [2005. Predicting in vivo soft tissue masses of the lower extremity using segment anthropometric measures and DXA. Journal of Applied Biomechanics, 21...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.02.013

    authors: Burkhart TA,Arthurs KL,Andrews DM

    更新日期:2008-01-01 00:00:00

  • Site specific inelasticity of arterial tissue.

    abstract::Understanding the mechanical behaviour of arterial tissue is vital to the development and analysis of medical devices targeting diseased vessels. During angioplasty and stenting, stress softening and permanent deformation of the vessel wall occur during implantation of the device, however little data exists on the ine...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.02.026

    authors: Maher E,Early M,Creane A,Lally C,Kelly DJ

    更新日期:2012-05-11 00:00:00

  • Jet collisions and vortex reversal in the human left ventricle.

    abstract::Unnatural dynamics of the notorious vortex in the left ventricle is often associated with cardiac disease. Understanding how different cardiac diseases alter the flow physics in the left ventricle may therefore provide a powerful tool for disease detection. In this work, the fluid dynamics in the left ventricle subjec...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.07.023

    authors: Di Labbio G,Kadem L

    更新日期:2018-09-10 00:00:00

  • The vesico-urethral pressuregram analysis of urethral function under stress.

    abstract::About one-third of older multiparous women are prone to stress urinary incontinence (SUI): unwanted urine loss during activities which suddenly raise intra-abdominal pressure. In this paper we describe and test a method for visualizing and analyzing the function of the urinary continence control system (CCS) under str...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)81291-2

    authors: Kim KJ,Ashton-Miller JA,Strohbehn K,DeLancey JO,Schultz AB

    更新日期:1997-01-01 00:00:00

  • Internal strain gradients quantified in bone under load using high-energy X-ray scattering.

    abstract::High-energy synchrotron X-ray scattering (>60 keV) allows noninvasive quantification of internal strains within bone. In this proof-of-principle study, wide angle X-ray scattering maps internal strain vs position in cortical bone (murine tibia, bovine femur) under compression, specifically using the response of the mi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.10.015

    authors: Stock SR,Yuan F,Brinson LC,Almer JD

    更新日期:2011-01-11 00:00:00

  • Modelling the mechanical effect of muscles with large attachment sites: application to the shoulder mechanism.

    abstract::A general theory is described for deriving the mechanical effect of muscles with large attachment sites. In a cadaver experiment the complete attachment sites and bundle distribution of 16 muscles of the shoulder mechanism were recorded. These data were used to calculate the mechanical effect, i.e. the resulting force...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90007-a

    authors: Van der Helm FC,Veenbaas R

    更新日期:1991-01-01 00:00:00

  • High-resolution spatial mapping of shear properties in cartilage.

    abstract::Structural properties of articular cartilage such as proteoglycan content, collagen content and collagen alignment are known to vary over length scales as small as a few microns (Bullough and Goodfellow, 1968; Bi et al., 2006). Characterizing the resulting variation in mechanical properties is critical for understandi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.012

    authors: Buckley MR,Bergou AJ,Fouchard J,Bonassar LJ,Cohen I

    更新日期:2010-03-03 00:00:00

  • Inter-segmental coordination: motor pattern in humans stepping over an obstacle with mechanical ankle joint friction.

    abstract::This study examined the influence of a mechanical perturbation of the ankle joint on obstacle avoidance pattern. A decoupled control between the distal joint and the combined (hip-knee) proximal joints was observed according to the task requirement. In this context, a greater mechanical friction at the ankle should be...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2004.07.019

    authors: Gueguen N,Charbonneau M,Robert G,Coyle T,Prince F,Mouchnino L

    更新日期:2005-07-01 00:00:00

  • Biomechanical influences of pin placement and elbow angle on hinge alignment and joint distraction of bridged elbow-pin-fixator construct.

    abstract::Joint distraction and mobilization with a hinged external fixator preserves elbow stability and mobility. However, the alignment of both elbow and fixator hinges was the initial prerequisite of the arthrodiatasis technique. The main goal of this study was to numerically evaluate the kinematic influence of the device, ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.07.030

    authors: Shih KS,Lin SC,Chao CK,Lee WS,Lu TW,Hou SM

    更新日期:2010-03-03 00:00:00

  • The exoskeletal structure and tensile loading behavior of an ant neck joint.

    abstract::Insects have evolved mechanical form and function over millions of years. Ants, in particular, can lift and carry heavy loads relative to their body mass. Loads are lifted with the mouthparts, transferred through the neck joint to the thorax, and distributed over six legs and tarsi (feet) that anchor to the supporting...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.10.053

    authors: Nguyen V,Lilly B,Castro C

    更新日期:2014-01-22 00:00:00

  • Comparison of muscle forces and joint load from an optimization and EMG assisted lumbar spine model: towards development of a hybrid approach.

    abstract::The purpose of this study was to determine whether the same estimates of individual muscle and L4/L5 lumbar joint compressive forces result from an optimization (OPT) compared to an electromyography (EMG) assisted approach for solving the inderminate moment equilibrium equations in the same anatomical model. Four male...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)00065-c

    authors: Cholewicki J,McGill SM,Norman RW

    更新日期:1995-03-01 00:00:00

  • Can fabric sensors monitor breast motion?

    abstract::To establish whether conducting polymer-coated fabric sensors could be used to monitor breast motion, vertical breast motion of two large breasted women (C+ bra cup) was simultaneously monitored using an OPTOTRAK 3020 motion analysis system (200 Hz) and polymer-coated fabric sensors linked to a custom-made Bluetooth t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.01.020

    authors: Campbell TE,Munro BJ,Wallace GG,Steele JR

    更新日期:2007-01-01 00:00:00

  • Finite element investigation of the loading rate effect on the spinal load-sharing changes under impact conditions.

    abstract::Sudden deceleration and frontal/rear impact configurations involve rapid movements that can cause spinal injuries. This study aimed to investigate the rotation rate effect on the L2-L3 motion segment load-sharing and to identify which spinal structure is at risk of failure and at what rotation velocity the failure may...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.036

    authors: El-Rich M,Arnoux PJ,Wagnac E,Brunet C,Aubin CE

    更新日期:2009-06-19 00:00:00

  • Assessment of gait patterns using neural networks.

    abstract::A new approach for the assessment of gait patterns is presented. The use of neural network techniques for decision making in gait analysis is for some purposes more effective than biomechanical methods or conventional statistics. To demonstrate this, a neural network was trained to distinguish 'healthy' from 'patholog...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90028-d

    authors: Holzreiter SH,Köhle ME

    更新日期:1993-06-01 00:00:00

  • Mechanical effects of continuous passive motion on the lumbar spine in seating.

    abstract::The aim of this study was to develop a model which describes the mechanical spinal response to small alternating pelvic stimulation induced by an active rotational movement of a normal chair. The rotary continuous passive motion (RCPM) of the seat about a vertical axis of only 0.6 degrees resulted in an increased in s...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00231-6

    authors: van Deursen DL,Lengsfeld M,Snijders CJ,Evers JJ,Goossens RH

    更新日期:2000-06-01 00:00:00

  • Does cancellous screw insertion torque depend on bone mineral density and/or microarchitecture?

    abstract::During insertion of a cancellous bone screw, the torque level reaches a plateau, at the engagement of all the screw threads prior to the screw head contact. This plateau torque (T(Plateau)) was found to be a good predictor of the insertion failure torque (stripping) and also exhibited strong positive correlations with...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.11.030

    authors: Ab-Lazid R,Perilli E,Ryan MK,Costi JJ,Reynolds KJ

    更新日期:2014-01-22 00:00:00

  • Estimation of stride length in level walking using an inertial measurement unit attached to the foot: a validation of the zero velocity assumption during stance.

    abstract::In a variety of applications, inertial sensors are used to estimate spatial parameters by double integrating over time their coordinate acceleration components. In human movement applications, the drift inherent to the accelerometer signals is often reduced by exploiting the cyclical nature of gait and under the hypot...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.04.035

    authors: Peruzzi A,Della Croce U,Cereatti A

    更新日期:2011-07-07 00:00:00

  • Isolated changes in femoral version do not alter intra-articular contact mechanics in cadaveric hips.

    abstract::Abnormal femoral version is a deformity in the angle between the femoral neck and the transcondylar axis of the knee. Both femoral anteversion and retroversion alter passive and active rotation of the hip and are associated with intra-articular or extra-articular impingement. However, little is known about the effect ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109891

    authors: Meyer AM,Thomas-Aitken HD,Brouillette MJ,Westermann RW,Goetz JE

    更新日期:2020-08-26 00:00:00

  • Compact bone: numerical simulation of mechanical characteristics.

    abstract::One of the main difficulties encountered in the numerical simulation of the anisotropic elastic characteristics of compact bone is to account for the Haversian microstructure when determining the overall macroscopic behavior. Engineering analyses of such problems are usually based on 'homogenized approximations'. Comp...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90031-9

    authors: Crolet JM,Aoubiza B,Meunier A

    更新日期:1993-06-01 00:00:00

  • Deficiency of macrophage migration inhibitory factor gene delays healing of the medial collateral ligament: a biomechanical and biological study.

    abstract::The role played by macrophage migration inhibitory factor (MIF) in the process of wound healing is controversial. Besides, there have been no reports that investigated the expression or the role of MIF in the repair process after ligament injury. In this study, we hypothesized that the deficiency in MIF gene might del...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.09.018

    authors: Kitayama S,Onodera S,Kondo E,Kobayashi T,Miyatake S,Kitamura N,Tohyama H,Yasuda K

    更新日期:2011-02-03 00:00:00

  • Experimental study of physiological pulsatile flow past valve prosthesis in a model of human aorta--II. Tilting disc valves and the effect of orientation.

    abstract::In Part II of this two paper sequence, pulsatile flow development past a tilting disc valve in a model human aorta has been studied using quantitative laser Doppler techniques. The valve was mounted in three different orientations with respect to the aortic root in this study. Under pulsatile flow, the region of flow ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(85)90052-1

    authors: Chandran KB,Khalighi B,Chen CJ

    更新日期:1985-01-01 00:00:00

  • The human ankle during walking: implications for design of biomimetic ankle prostheses.

    abstract::The non-disabled human ankle joint was examined during walking in an attempt to determine overall system characteristics for use in the design of ankle prostheses. The hypothesis of the study was that the quasi-stiffness of the ankle changes when walking at different walking speeds. The hypothesis was examined using s...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.01.017

    authors: Hansen AH,Childress DS,Miff SC,Gard SA,Mesplay KP

    更新日期:2004-10-01 00:00:00

  • Influence of shoes and heel strike on the loading of the hip joint.

    abstract::The forces and moments acting at the hip joint influence the long-term stability of the fixation of endoprostheses and the course of coxarthrosis. These loads may depend on the kind of footwear and the walking or running style. These factors were investigated in a patient with instrumented hip implants. He wore differ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)00129-r

    authors: Bergmann G,Kniggendorf H,Graichen F,Rohlmann A

    更新日期:1995-07-01 00:00:00

  • Using regression models to determine the poroelastic properties of cartilage.

    abstract::The feasibility of determining biphasic material properties using regression models was investigated. A transversely isotropic poroelastic finite element model of stress relaxation was developed and validated against known results. This model was then used to simulate load intensity for a wide range of material proper...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.05.028

    authors: Chung CY,Mansour JM

    更新日期:2013-07-26 00:00:00

  • Explaining Parkinsonian postural sway variabilities using intermittent control theory.

    abstract::Postural impairment due to neuro-degenerative disorders such as Parkinson's Disease (PD) leads to restricted gait patterns, fall-related injuries, decreased mobility, and loss of functional independence. Though several clinical and posturographic studies have attempted to reveal the complex pathophysiology involved in...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109791

    authors: Dash R,Shah VV,Palanthandalam-Madapusi HJ

    更新日期:2020-05-22 00:00:00

  • Study on modelling of PMMA bone cement polymerisation.

    abstract::This contribution is concerned with the modelling of PMMA-based bone cement polymerisation process and the associated heat effect. While existing models use description in terms of the so-called polymerisation fraction to fit the experimental data, the new model is constructed in such a way as to mimic the chemical pr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.06.021

    authors: Stańczyk M

    更新日期:2005-07-01 00:00:00

  • Muscle activities of the lower limb during level and uphill running.

    abstract::This study aimed to compare the muscle activities of the lower limb during overground level running (LR) and uphill running (UR) by using a musculoskeletal model. Six male distance runners ran at three running speeds (slow: 3.3 m/s; medium: 4.2 m/s; and high: 5.0 m/s) on a level runway and a slope of 9.1% grade in whi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.05.028

    authors: Yokozawa T,Fujii N,Ae M

    更新日期:2007-01-01 00:00:00

  • The effects of tensile-compressive loading mode and microarchitecture on microdamage in human vertebral cancellous bone.

    abstract::The amount of microdamage in bone tissue impairs mechanical performance and may act as a stimulus for bone remodeling. Here we determine how loading mode (tension vs. compression) and microstructure (trabecular microarchitecture, local trabecular thickness, and presence of resorption cavities) influence the number and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.10.011

    authors: Lambers FM,Bouman AR,Tkachenko EV,Keaveny TM,Hernandez CJ

    更新日期:2014-11-28 00:00:00