A musculoskeletal model of the human lower extremity: the effect of muscle, tendon, and moment arm on the moment-angle relationship of musculotendon actuators at the hip, knee, and ankle.

Abstract:

:We have developed a musculoskeletal model of the human lower extremity for computer simulation studies of musculotendon function and muscle coordination during movement. This model incorporates the salient features of muscle and tendon, specifies the musculoskeletal geometry and musculotendon parameters of 18 musculotendon actuators, and defines the active isometric moment of these actuators about the hip, knee, and ankle joints in the sagittal plane. We found that tendon slack length, optimal muscle-fiber length, and moment arm are different for each actuator, thus each actuator develops peak isometric moment at a different joint angle. The joint angle where an actuator produces peak moment does not necessarily coincide with the joint angle where: (1) muscle force peaks, (2) moment arm peaks, or (3) the in vivo moment developed by maximum voluntary contractions peaks. We conclude that when tendon is neglected in analyses of musculotendon force or moment about joints, erroneous predictions of human musculotendon function may be stated, not only in static situations as studied here, but during movement as well.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Hoy MG,Zajac FE,Gordon ME

doi

10.1016/0021-9290(90)90349-8

subject

Has Abstract

pub_date

1990-01-01 00:00:00

pages

157-69

issue

2

eissn

0021-9290

issn

1873-2380

pii

0021-9290(90)90349-8

journal_volume

23

pub_type

杂志文章
  • Variability of tissue mineral density can determine physiological creep of human vertebral cancellous bone.

    abstract::Creep is a time-dependent viscoelastic deformation observed under a constant prolonged load. It has been indicated that progressive vertebral deformation due to creep may increase the risk of vertebral fracture in the long-term. The objective of this study was to examine the relationships of creep with trabecular arch...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.03.025

    authors: Kim DG,Shertok D,Ching Tee B,Yeni YN

    更新日期:2011-06-03 00:00:00

  • Experimental determination of sarcomere force-length relationship in type-I human skeletal muscle fibers.

    abstract::The objectives of this study were to measure the active and passive force-length (F-L) relationships in type-I human single muscle fibers and to compare the results to predictions from the sliding filament model (the "standard model"). We measured isometric forces in chemically skinned fibers at different sarcomere le...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.06.013

    authors: Gollapudi SK,Lin DC

    更新日期:2009-09-18 00:00:00

  • The between-day reliability of peroneus longus EMG during walking.

    abstract::The peroneus longus (PL) is a rearfoot evertor, important in frontal plane foot motion. Studying PL function has been limited by previous electromyography (EMG) studies reporting poor between-day reliability. Due to its close proximity to adjacent muscles, EMG measures of PL may be susceptible to crosstalk, thus corre...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.01.037

    authors: Reeves J,Jones R,Liu A,Bent L,Nester C

    更新日期:2019-03-27 00:00:00

  • Muscle fascicle and series elastic element length changes along the length of the human gastrocnemius during walking and running.

    abstract::Ultrasound imaging has recently been used to distinguish the length changes of muscle fascicles from those of the whole muscle tendon complex during real life movements. The complicated three-dimensional architecture of pennate muscles can however cause heterogeneity in the length changes along the length of a muscle....

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.10.035

    authors: Lichtwark GA,Bougoulias K,Wilson AM

    更新日期:2007-01-01 00:00:00

  • Prediction of upper extremity impact forces during falls on the outstretched hand.

    abstract::Among the most common causes of upper extremity fracture is a fall on the outstretched hand. Yet few data exist on the biomechanical factors which affect injury risk during this event. In this study, we measured impact forces during low-height (0-5 cm), forward falls onto the outstretched hand, and found that these ar...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00137-7

    authors: Chiu J,Robinovitch SN

    更新日期:1998-12-01 00:00:00

  • Validation of shear wave elastography in skeletal muscle.

    abstract::Skeletal muscle is a very dynamic tissue, thus accurate quantification of skeletal muscle stiffness throughout its functional range is crucial to improve the physical functioning and independence following pathology. Shear wave elastography (SWE) is an ultrasound-based technique that characterizes tissue mechanical pr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.07.033

    authors: Eby SF,Song P,Chen S,Chen Q,Greenleaf JF,An KN

    更新日期:2013-09-27 00:00:00

  • Maximum height and minimum time vertical jumping.

    abstract::The performance criterion in maximum vertical jumping has typically been assumed to simply raise the center of mass as high as possible. In many sporting activities minimizing movement time during the jump is likely also critical to successful performance. The purpose of this study was to examine maximum height jumps ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.04.021

    authors: Domire ZJ,Challis JH

    更新日期:2015-08-20 00:00:00

  • A mechanically decoupled two force component bicycle pedal dynamometer.

    abstract::A design is presented for a bicycle pedal dynamometer that measures both normal and tangential forces (i.e. driving forces). Mechanical decoupling is used to reduce the cross-sensitivity of the dynamometer to loads doing no work to propel the bicycle. This obviates the need to measure all six loads for accurate data r...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90144-3

    authors: Newmiller J,Hull ML,Zajac FE

    更新日期:1988-01-01 00:00:00

  • Collagen fibril diameters increase and fibril densities decrease in skin subjected to repetitive compressive and shear stresses.

    abstract::Understanding microstructural changes that occur in skin subjected to repetitive mechanical stress is crucial towards the development of therapies to enhance skin adaptation and load tolerance in patients at risk of skin breakdown (e.g. prosthesis users, wheelchair users). To determine if collagen fibril diameter, col...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00145-2

    authors: Sanders JE,Goldstein BS

    更新日期:2001-12-01 00:00:00

  • Effect of LIMK2 RNAi on reorganization of the actin cytoskeleton in osteoblasts induced by fluid shear stress.

    abstract::The biomechanical characteristics of bone tissue and its cells under mechanical stress are significant for bone biomechanics research, but the mechanism of mechanotransduction is still unknown. It has been established that the actin cytoskeleton of osteoblasts plays an important role in this process. However, the stru...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.08.010

    authors: Fu Q,Wu C,Shen Y,Zheng S,Chen R

    更新日期:2008-11-14 00:00:00

  • Fatigue damage of human tendons.

    abstract::The study was designed to examine the effects of partial fatigue on specific mechanical parameters which characterise human tendons in vitro. Specimens prepared from 12 intact Extensor digitorum longus tendons of the foot were subjected to partial fatigue, equivalent to 25% of the median fatigue life, by a cyclic squa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00177-4

    authors: Schechtman H,Bader DL

    更新日期:2002-03-01 00:00:00

  • Modelling the mechanical effect of muscles with large attachment sites: application to the shoulder mechanism.

    abstract::A general theory is described for deriving the mechanical effect of muscles with large attachment sites. In a cadaver experiment the complete attachment sites and bundle distribution of 16 muscles of the shoulder mechanism were recorded. These data were used to calculate the mechanical effect, i.e. the resulting force...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90007-a

    authors: Van der Helm FC,Veenbaas R

    更新日期:1991-01-01 00:00:00

  • Blood flow patterns in an anatomically realistic coronary vessel: influence of three different reconstruction methods.

    abstract::Many clinical studies suggest that local blood flow patterns are involved in the location and development of atherosclerosis. In coronary diseases, this assumption should be corroborated by quantitative information on local hemodynamic parameters such as pressure, velocity or wall shear stress. Nowadays, computational...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00179-3

    authors: Berthier B,Bouzerar R,Legallais C

    更新日期:2002-10-01 00:00:00

  • Understanding the fluid mechanics behind transverse wall shear stress.

    abstract::The patchy distribution of atherosclerosis within arteries is widely attributed to local variation in haemodynamic wall shear stress (WSS). A recently-introduced metric, the transverse wall shear stress (transWSS), which is the average over the cardiac cycle of WSS components perpendicular to the temporal mean WSS vec...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.035

    authors: Mohamied Y,Sherwin SJ,Weinberg PD

    更新日期:2017-01-04 00:00:00

  • A model of surfactant-induced surface tension effects on the parenchymal tethering of pulmonary airways.

    abstract::We developed a computational model of lung parenchyma, which is comprised of individual alveolar chamber models. Each alveolus is modeled by a truncated octahedron. Considering the force balance between the elastin and collagen fibers laying on the alveolar membrane and the pressures acting on the membrane, we compute...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.11.031

    authors: Fujioka H,Halpern D,Gaver DP 3rd

    更新日期:2013-01-18 00:00:00

  • Maximum isometric arm forces in the horizontal plane.

    abstract::In this paper, we measured the maximum isometric force at the hand in eight directions in the horizontal plane and at five positions in the workplace. These endpoint forces were the result of shoulder horizontal adduction/abduction and elbow flexion/extension torques. We found that the normalized maximum forces of all...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2005.01.004

    authors: Jan Nijhof E,Gabriel DA

    更新日期:2006-01-01 00:00:00

  • Analysis of head acceleration events in collegiate-level American football: A combination of qualitative video analysis and in-vivo head kinematic measurement.

    abstract::The contact nature of American football has made head acceleration exposure a concern. We aimed to quantify the head kinematics associated with direct helmet contact and inertial head loading events in collegiate-level American football. A cohort of collegiate-level players were equipped with instrumented mouthguards ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109969

    authors: Tierney GJ,Kuo C,Wu L,Weaving D,Camarillo D

    更新日期:2020-09-18 00:00:00

  • Hamstring muscle kinematics and activation during overground sprinting.

    abstract::Hamstring muscle strain injury is one of the most commonly seen injuries in sports such as track and field, soccer, football, and rugby. The purpose of this study was to advance our understanding of the mechanisms of hamstring muscle strain injuries during over ground sprinting by investigating hamstring muscle-tendon...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.09.005

    authors: Yu B,Queen RM,Abbey AN,Liu Y,Moorman CT,Garrett WE

    更新日期:2008-11-14 00:00:00

  • Comparing different approaches for determining joint torque parameters from isovelocity dynamometer measurements.

    abstract::Strength, or maximum joint torque, is a fundamental factor governing human movement, and is regularly assessed for clinical and rehabilitative purposes as well as for research into human performance. This study aimed to identify the most appropriate protocol for fitting a maximum voluntary torque function to experimen...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.11.024

    authors: Forrester SE,Yeadon MR,King MA,Pain MT

    更新日期:2011-03-15 00:00:00

  • Monitoring of fracture healing by lateral and axial vibration analysis.

    abstract::The ability to monitor the healing of bone fractures is crucially important in their treatment. The aim of the present study was to develop and validate an objective method for monitoring fracture healing based on bone vibrational response. An analytic model was formulated, with which the mechanical parameters at the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90060-g

    authors: Nikiforidis G,Bezerianos A,Dimarogonas A,Sutherland C

    更新日期:1990-01-01 00:00:00

  • Regressions for estimating muscle parameters in the thoracic and lumbar trunk for use in musculoskeletal modeling.

    abstract::Musculoskeletal modeling requires information on muscle parameters such as cross-sectional area (CSA) and moment arms. A variety of previous studies have reported muscle parameters in the trunk based on in vivo imaging, but there remain gaps in the available data as well as limitations in the generalizability of such ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.10.004

    authors: Anderson DE,D'Agostino JM,Bruno AG,Manoharan RK,Bouxsein ML

    更新日期:2012-01-03 00:00:00

  • A force transducer to measure individual finger loads during activities of daily living.

    abstract::A new six-degree-of-freedom force transducer has been manufactured, with the sensitivity to measure forces in the range +/-100 N and moments of up to +/-5 Nm. The transducer incorporates two mechanical components: shear forces and bending moments are measured via a strain-gauged tubular section whilst axial forces are...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00054-8

    authors: Fowler NK,Nicol AC

    更新日期:1999-07-01 00:00:00

  • Elbow and wrist joint contact forces during occupational pick and place activities.

    abstract::A three-dimensional, mathematical model of the elbow and wrist joints, including 15 muscle units, 3 ligaments and 4 joint forces, has been developed. A new strain gauge transducer has been developed to measure functional grip forces. The device measures radial forces divided into six components and forces of up to 250...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00184-0

    authors: Chadwick EK,Nicol AC

    更新日期:2000-05-01 00:00:00

  • Sagittal range of motion of the thoracic spine using inertial tracking device and effect of measurement errors on model predictions.

    abstract::Range of motion (ROM) of the thoracic spine has implications in patient discrimination for diagnostic purposes and in biomechanical models for predictions of spinal loads. Few previous studies have reported quite different thoracic ROMs. Total (T1-T12), lower (T5-T12) and upper (T1-T5) thoracic, lumbar (T12-S1), pelvi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.09.003

    authors: Hajibozorgi M,Arjmand N

    更新日期:2016-04-11 00:00:00

  • Ligament fibre recruitment at the human ankle joint complex in passive flexion.

    abstract::Knowledge of ligament fibre recruitment at the human ankle joint complex is a fundamental prerequisite for analysing mobility and stability. Previous experimental and modelling studies have shown that ankle motion must be guided by fibres within the calcaneofibular and tibiocalcaneal ligaments, which remain approximat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.02.043

    authors: Stagni R,Leardini A,Ensini A

    更新日期:2004-12-01 00:00:00

  • Effects of walking speed, strength and range of motion on gait stability in healthy older adults.

    abstract::Falls pose a tremendous risk to those over 65 and most falls occur during locomotion. Older adults commonly walk slower, which many believe helps improve walking stability. While increased gait variability predicts future fall risk, increased variability is also caused by walking slower. Thus, we need to better unders...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.08.002

    authors: Kang HG,Dingwell JB

    更新日期:2008-10-20 00:00:00

  • Loads on an internal spinal fixation device during sitting.

    abstract::Sitting is often assumed to involve high loads on the spine as well as on implants for stabilising the spine. Loads on internal spinal fixation devices were therefore measured in ten patients sitting on several types of seats, including a stool, a stool with a padded wedge, a chair, a physiotherapy ball, a knee-stool,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00073-2

    authors: Rohlmann A,Arntz U,Graichen F,Bergmann G

    更新日期:2001-08-01 00:00:00

  • Challenges to bone formation in spinal fusion.

    abstract::Spinal arthrodesis continues to expand in clinical indications and surgical practice. Despite a century of study, failure of bone formation or pseudarthrosis can occur in individual patients with debilitating clinical symptoms. Here we review biological and technical aspects of spinal fusion under active investigation...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2010.10.021

    authors: Reid JJ,Johnson JS,Wang JC

    更新日期:2011-01-11 00:00:00

  • A simplified model of scar contraction.

    abstract::The healing of wounds is a complex process and the contraction of the resulting scar can have a negative impact on the neighbouring skin. A finite element model of skin simulating the contraction of a scar and deformation of the surrounding skin is presented. The skin is represented by an orthotropic-viscoelastic cons...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.02.024

    authors: Flynn C,McCormack BA

    更新日期:2008-01-01 00:00:00

  • 'Equivalent geometry' of the knee and the prediction of tensions along the cruciates: an experimental study.

    abstract::In this paper we introduce the concept of the functional (or equivalent) geometry of the knee, which is an attempt to reduce the natural knee with its complex geometry, frictional resistance and deformable cartilage into a two-dimensional joint comprising rigid femur and tibia in frictionless contact. An apparatus and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00141-9

    authors: Chan SC,Seedhom BB

    更新日期:1999-01-01 00:00:00