Vocal fold contact patterns based on normal modes of vibration.

Abstract:

:The fluid-structure interaction and energy transfer from respiratory airflow to self-sustained vocal fold oscillation continues to be a topic of interest in vocal fold research. Vocal fold vibration is driven by pressures on the vocal fold surface, which are determined by the shape of the glottis and the contact between vocal folds. Characterization of three-dimensional glottal shapes and contact patterns can lead to increased understanding of normal and abnormal physiology of the voice, as well as to development of improved vocal fold models, but a large inventory of shapes has not been directly studied previously. This study aimed to take an initial step toward characterizing vocal fold contact patterns systematically. Vocal fold motion and contact was modeled based on normal mode vibration, as it has been shown that vocal fold vibration can be almost entirely described by only the few lowest order vibrational modes. Symmetric and asymmetric combinations of the four lowest normal modes of vibration were superimposed on left and right vocal fold medial surfaces, for each of three prephonatory glottal configurations, according to a surface wave approach. Contact patterns were generated from the interaction of modal shapes at 16 normalized phases during the vibratory cycle. Eight major contact patterns were identified and characterized by the shape of the flow channel, with the following descriptors assigned: convergent, divergent, convergent-divergent, uniform, split, merged, island, and multichannel. Each of the contact patterns and its variation are described, and future work and applications are discussed.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Smith SL,Titze IR

doi

10.1016/j.jbiomech.2018.04.011

subject

Has Abstract

pub_date

2018-05-17 00:00:00

pages

177-184

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(18)30275-6

journal_volume

73

pub_type

杂志文章
  • Propulsion biomechanics do not differ between athletic and nonathletic manual wheelchair users in their daily wheelchairs.

    abstract::The purpose of this study was to investigate whether athletic and nonathletic manual wheelchair users (MWU) display differences in kinetic and kinematic variables during daily wheelchair propulsion. Thirty-nine manual wheelchair users (athletic n = 25; nonathletic n = 14) propelled their own daily living wheelchair on...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109725

    authors: Briley SJ,Vegter RJK,Tolfrey VL,Mason BS

    更新日期:2020-05-07 00:00:00

  • Numerical errors and uncertainties in finite-element modeling of trabecular bone.

    abstract::Although micromechanical finite-element models are being increasingly used to help interpret the results of bio-mechanical tests, there has not yet been a systematic study of the numerical errors and uncertainties that occur with these methods. In this work, finite-element models of human L1 vertebra have been used to...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00108-0

    authors: Ladd AJ,Kinney JH

    更新日期:1998-10-01 00:00:00

  • Comparison of shear forces and ligament loading in the healthy and ACL-deficient knee during gait.

    abstract::The purpose of this study was to predict and explain the pattern of shear force and ligament loading in the ACL-deficient knee during walking, and to compare these results to similar calculations for the healthy knee. Musculoskeletal modeling and computer simulation were combined to calculate ligament forces in the AC...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.07.001

    authors: Shelburne KB,Pandy MG,Torry MR

    更新日期:2004-03-01 00:00:00

  • A computational study of invariant I5 in a nearly incompressible transversely isotropic model for white matter.

    abstract::The aligned axonal fiber bundles in white matter make it suitable to be modeled as a transversely isotropic material. Recent experimental studies have shown that a minimal form, nearly incompressible transversely isotropic (MITI) material model, is capable of describing mechanical anisotropy of white matter. Here, we ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.03.025

    authors: Feng Y,Qiu S,Xia X,Ji S,Lee CH

    更新日期:2017-05-24 00:00:00

  • Nonlinear finite element simulation to elucidate the efficacy of slit arteriotomy for end-to-side arterial anastomosis in microsurgery.

    abstract::The slit arteriotomy for end-to-side arterial microanastomosis is a technique used to revascularize free flaps in reconstructive surgery. Does a slit open to a width sufficient for blood supply? How is the slit opening affected by factors, such as arterial wall thickness and material stiffness? To answer these questio...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.12.015

    authors: Gu H,Chua A,Tan BK,Chew Hung K

    更新日期:2006-01-01 00:00:00

  • Ground reaction forces are more sensitive gait measures than temporal parameters in rodents following rotator cuff injury.

    abstract::Gait analysis is a quantitative, non-invasive technique that can be used to investigate functional changes in animal models of musculoskeletal disease. Changes in ground reaction forces following injury have been observed that coincide with differences in tissue mechanical and histological properties during healing. H...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.12.027

    authors: Pardes AM,Freedman BR,Soslowsky LJ

    更新日期:2016-02-08 00:00:00

  • Theoretical justification for distal foot power equation.

    abstract::The distal foot power equation is a simple yet powerful tool for estimating the power dissipation or generation within the foot even while modeling it as a rigid body. It was introduced over two decades ago, but has seen a resurgence of use in recent years. Nevertheless, the theoretical justification for this formula ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109964

    authors: Ashby BM

    更新日期:2020-08-26 00:00:00

  • Diffusion of water in skeletal muscle tissue is not influenced by compression in a rat model of deep tissue injury.

    abstract::Sustained mechanical loading of skeletal muscle may result in the development of a severe type of pressure ulcer, referred to as deep tissue injury. Recently it was shown that the diffusion of large molecules (10-150kDa) is impaired during deformation of tissue-engineered skeletal muscle, suggesting a role for impaire...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.07.043

    authors: van Nierop BJ,Stekelenburg A,Loerakker S,Oomens CW,Bader D,Strijkers GJ,Nicolay K

    更新日期:2010-02-10 00:00:00

  • The three-dimensional determination of internal loads in the lower extremity.

    abstract::A three-dimensional model of the lower limb containing 47 muscles was developed to study the differences between a two- and three-dimensional approach for determining internal loads, the role of the dynamic joint representation, and the behavior of different load-bearing criteria in walking and running. The problem of...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00089-4

    authors: Glitsch U,Baumann W

    更新日期:1997-11-01 00:00:00

  • Sensitivity of a Hill-based muscle model to perturbations in model parameters.

    abstract::Musculoskeletal simulations of human movement commonly use Hill muscle models to predict muscle forces, but their sensitivity to model parameter values is not well understood. The purpose of this study was to evaluate muscle model sensitivity to perturbations in 14 Hill muscle model parameters in forward dynamic simul...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.06.005

    authors: Scovil CY,Ronsky JL

    更新日期:2006-01-01 00:00:00

  • Deficiency of macrophage migration inhibitory factor gene delays healing of the medial collateral ligament: a biomechanical and biological study.

    abstract::The role played by macrophage migration inhibitory factor (MIF) in the process of wound healing is controversial. Besides, there have been no reports that investigated the expression or the role of MIF in the repair process after ligament injury. In this study, we hypothesized that the deficiency in MIF gene might del...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.09.018

    authors: Kitayama S,Onodera S,Kondo E,Kobayashi T,Miyatake S,Kitamura N,Tohyama H,Yasuda K

    更新日期:2011-02-03 00:00:00

  • Predictive equations to estimate spinal loads in symmetric lifting tasks.

    abstract::Response surface methodology is used to establish robust and user-friendly predictive equations that relate responses of a complex detailed trunk finite element biomechanical model to its input variables during sagittal symmetric static lifting activities. Four input variables (thorax flexion angle, lumbar/pelvis rati...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.08.028

    authors: Arjmand N,Plamondon A,Shirazi-Adl A,Larivière C,Parnianpour M

    更新日期:2011-01-04 00:00:00

  • Alteration of blood hemorheologic properties during cerebral ischemia and reperfusion in rats.

    abstract::The cerebral ischemia and reperfusion rat model was employed in this experiment to study the rheological properties (i.e. viscosity, hematocrit, red blood cell deformability and thixotropic properties) of whole blood. The results of this study show that a significant relation exists between the duration of cerebral is...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00180-9

    authors: Kuke D,Donghua L,Xiaoyan S,Yanjun Z

    更新日期:2001-02-01 00:00:00

  • Novel compact device for clinically measuring extraocular muscle (EOM) tension.

    abstract::Accurate knowledge of extraocular muscle (EOM) tension is important for the diagnosis of and surgical planning for strabismus, such as choosing which eye to operate or determining the amount of muscle displacement. Previous evaluations of passive EOM tension have relied extensively on the experience and skill of ophth...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109955

    authors: Shin HJ,Lee SJ,Oh CS,Kang H

    更新日期:2020-08-26 00:00:00

  • Stone comminution correlates with the average peak pressure incident on a stone during shock wave lithotripsy.

    abstract::To investigate the roles of lithotripter shock wave (LSW) parameters and cavitation in stone comminution, a series of in vitro fragmentation experiments have been conducted in water and 1,3-butanediol (a cavitation-suppressive fluid) at a variety of acoustic field positions of an electromagnetic shock wave lithotripte...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.07.025

    authors: Smith N,Zhong P

    更新日期:2012-10-11 00:00:00

  • Variability observed in mechano-regulated in vivo tissue differentiation can be explained by variation in cell mechano-sensitivity.

    abstract::Computational simulations of tissue differentiation have been able to capture the main aspects of tissue formation/regeneration observed in animal experiments-except for the considerable degree of variability reported. Understanding and modelling the source of this variability is crucial if computational tools are to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.02.003

    authors: Khayyeri H,Checa S,Tägil M,Aspenberg P,Prendergast PJ

    更新日期:2011-04-07 00:00:00

  • Haemodynamic effects of incomplete stent apposition in curved coronary arteries.

    abstract::Incomplete stent apposition (ISA, also known as malapposition) is a complication that affects day-to-day coronary stenting procedures. ISA is more prominent in complex arterial geometries, such as curvature, asa result of the limited conformability of coronary stents. These malapposed struts disturb the otherwise near...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.09.016

    authors: Chen WX,Poon EKW,Thondapu V,Hutchins N,Barlis P,Ooi A

    更新日期:2017-10-03 00:00:00

  • Assessment of blood volume flow in slightly curved arteries from a single velocity profile.

    abstract::Non-invasive estimation of arterial blood volume flow (BVF) has become a central issue in assessment of cardiovascular risk. Poiseuille and Womersley approaches are commonly used to assess the BVF from centerline velocity, but both methods neglect the influence of curvature. Based on the assumption that the velocity i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.04.032

    authors: Leguy CA,Bosboom EM,Hoeks AP,van de Vosse FN

    更新日期:2009-08-07 00:00:00

  • 3D printed clamps improve spine specimen fixation in biomechanical testing.

    abstract::This study presents an anatomically customizable fixation technique for biomechanical spine experiments using a 3D printed clamping system. The aim of this study is to evaluate the feasibility and compare the fixation rigidity of the novel technique to PMMA potting with and without screw augmentation. For this purpose...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109467

    authors: Cornaz F,Fasser MR,Spirig JM,Snedeker JG,Farshad M,Widmer J

    更新日期:2020-01-02 00:00:00

  • Measurements of the three-dimensional shape of the rib cage.

    abstract::A stereoradiographic method was developed to measure the three-dimensional shape of the rib cage in vivo in order to provide descriptive data and to study symmetry in the normal population. The method is also intended for use in description of rib asymmetry in scoliosis. Rib midlines were reconstructed from digitized ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90127-3

    authors: Dansereau J,Stokes IA

    更新日期:1988-01-01 00:00:00

  • In vivo kinematics and articular surface congruency of total ankle arthroplasty during gait.

    abstract::Relatively high rates of loosening and implant failure have been reported after total ankle arthroplasty. Abnormal kinematics and incongruency of the articular surface may cause increased contact pressure and rotational torque applied to the implant, leading to loosening and implant failure. We measured in vivo kinema...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.05.043

    authors: Yamaguchi S,Tanaka Y,Banks S,Kosugi S,Sasho T,Takahashi K,Takakura Y

    更新日期:2012-08-09 00:00:00

  • Virtually optimized insoles for offloading the diabetic foot: A randomized crossover study.

    abstract::Integration of objective biomechanical measures of foot function into the design process for insoles has been shown to provide enhanced plantar tissue protection for individuals at-risk of plantar ulceration. The use of virtual simulations utilizing numerical modeling techniques offers a potential approach to further ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.jbiomech.2017.06.028

    authors: Telfer S,Woodburn J,Collier A,Cavanagh PR

    更新日期:2017-07-26 00:00:00

  • Sex differences in active tibialis anterior stiffness evaluated using supersonic shear imaging.

    abstract::This study aimed to evaluate the sex difference in active muscle stiffness of the tibialis anterior muscle (TA) through shear modulus measurements performed using supersonic shear imaging (SSI) technique. Twenty-five women and twenty-one men participated in this study. Joint torque, electromyographic (EMG) activity an...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.08.008

    authors: Souron R,Bordat F,Farabet A,Belli A,Feasson L,Nordez A,Lapole T

    更新日期:2016-10-03 00:00:00

  • The mechanics of atherosclerotic plaque rupture by inclusion/matrix interfacial decohesion.

    abstract::Histological investigation along with finite element analysis of arterial wall/atherosclerotic plaque geometries indicates the paradoxical result that ruptures often occur at sites with predicted stresses of half the plaque cap strength. Recent experiments have revealed calcified cells within the cap suggesting that t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.06.012

    authors: Nguyen CM,Levy AJ

    更新日期:2010-10-19 00:00:00

  • Strain-induced damage reduces echo intensity changes in tendon during loading.

    abstract::Tendon functionality is related to its mechanical properties. Tendon damage leads to a reduction in mechanical strength and altered biomechanical behavior, and therefore leads to compromised ability to carry out normal functions such as joint movement and stabilization. Damage can also accumulate in the tissue and lea...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.04.004

    authors: Duenwald-Kuehl S,Lakes R,Vanderby R Jr

    更新日期:2012-06-01 00:00:00

  • Non-periodicity of blood flow and its influence on wall shear stress in the carotid artery bifurcation: An in vivo measurement-based computational study.

    abstract::Although arterial blood flow is physiologically non-periodic under resting conditions, periodic flow assumption has been widely adopted in most hemodynamic studies. So far, it remains unclear how the non-periodicity of blood flow would influence local hemodynamic parameters, especially wall shear stress (WSS) that ass...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109617

    authors: Zhou X,Yin L,Xu L,Liang F

    更新日期:2020-03-05 00:00:00

  • Ulceration, unsteadiness, and uncertainty: the biomechanical consequences of diabetes mellitus.

    abstract::Diabetes mellitus, which results from a failure of the endocrine system to control blood glucose levels within normal limits, affects approximately 15% of the population over the age of 65 in developed countries. Between 20-50% of people with diabetes for more than 10 years will experience symmetrical distal sensory n...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/0021-9290(93)90077-r

    authors: Cavanagh PR,Simoneau GG,Ulbrecht JS

    更新日期:1993-01-01 00:00:00

  • A computer-controlled mechanical culture system for biological testing of articular cartilage explants.

    abstract::A computer-controlled mechanical culture system was designed to investigate the interaction between mechanical stimuli and the metabolism of articular cartilage. The main features of this system include the following capabilities: (1) Accurately controlled static, permanent cyclic or intermittent cyclic mechanical loa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00040-7

    authors: Steinmeyer J

    更新日期:1997-08-01 00:00:00

  • Identification of a hemodynamic parameter for assessing treatment outcome of EDAS in Moyamoya disease.

    abstract::This work is a novel attempt to incorporate computational fluid dynamics (CFD) techniques in the analysis of hemodynamic parameters of Moyamoya disease (MMD). Highly prevalent in Asian countries, MMD is characterised by progressive occlusion of the intracranial Internal Carotid Arteries (ICA). We intend to identify a ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.11.029

    authors: Karunanithi K,Han C,Lee CJ,Shi W,Duan L,Qian Y

    更新日期:2015-01-21 00:00:00

  • Compact bone: numerical simulation of mechanical characteristics.

    abstract::One of the main difficulties encountered in the numerical simulation of the anisotropic elastic characteristics of compact bone is to account for the Haversian microstructure when determining the overall macroscopic behavior. Engineering analyses of such problems are usually based on 'homogenized approximations'. Comp...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90031-9

    authors: Crolet JM,Aoubiza B,Meunier A

    更新日期:1993-06-01 00:00:00