Identification of a hemodynamic parameter for assessing treatment outcome of EDAS in Moyamoya disease.

Abstract:

:This work is a novel attempt to incorporate computational fluid dynamics (CFD) techniques in the analysis of hemodynamic parameters of Moyamoya disease (MMD). Highly prevalent in Asian countries, MMD is characterised by progressive occlusion of the intracranial Internal Carotid Arteries (ICA). We intend to identify a reliable hemodynamic parameter that can be used to gauge treatment outcome. This will aid surgeons in the perioperative management of MMD patients. We carried out CFD analysis on eight patients (5 female, 3 male) with MMD treated by EDAS (encephalo-duro-arterio-synangiosis) between 2011 and 2012. All the eight patients presented with haemorrhage, with subsequent 4-12 month follow-up done using Magnetic Resonance Angiography (MRA) to capture auto-remodelling. We calculated percentage change in flow rate and pressure drop indicator (ΡDI) across the Left and Right ICA. Pressure drop indicator (PDI) is defined as the difference of pressure reduction within the carotid arteries, measured at post-op and follow up, using patient specific inflow rates. The measured percentage flow change and pressure reduction showed an increase at follow up for improved patients (characterised by angiography according to the method of Matsushima), who did not develop any complications after surgery. The inverse was observed in patients who were clinically classified as no change and retrogressed (according to the method of Matsushima) cases post-operation. This elucidates that our findings have instituted a new parameter that may well play a critical role as an assistive clinical decision making tool in MMD.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Karunanithi K,Han C,Lee CJ,Shi W,Duan L,Qian Y

doi

10.1016/j.jbiomech.2014.11.029

subject

Has Abstract

pub_date

2015-01-21 00:00:00

pages

304-9

issue

2

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(14)00617-4

journal_volume

48

pub_type

杂志文章
  • Active axial stress in mouse aorta.

    abstract::The study verifies the development of active axial stress in the wall of mouse aorta over a range of physiological loads when the smooth muscle cells are stimulated to contract. The results obtained show that the active axial stress is virtually independent of the magnitude of pressure, but depends predominately on th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.05.025

    authors: Agianniotis A,Rachev A,Stergiopulos N

    更新日期:2012-07-26 00:00:00

  • Shoe midsole hardness, sex and age effects on lower extremity kinematics during running.

    abstract::Previous studies investigating the effects of shoe midsole hardness on running kinematics have often used male subjects from within a narrow age range. It is unknown whether shoe midsole hardness has the same kinematic effect on male and female runners as well as runners from different age categories. As sex and age h...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.03.027

    authors: Nigg BM,Baltich J,Maurer C,Federolf P

    更新日期:2012-06-01 00:00:00

  • Variability of tissue mineral density can determine physiological creep of human vertebral cancellous bone.

    abstract::Creep is a time-dependent viscoelastic deformation observed under a constant prolonged load. It has been indicated that progressive vertebral deformation due to creep may increase the risk of vertebral fracture in the long-term. The objective of this study was to examine the relationships of creep with trabecular arch...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.03.025

    authors: Kim DG,Shertok D,Ching Tee B,Yeni YN

    更新日期:2011-06-03 00:00:00

  • Assessment of gait patterns using neural networks.

    abstract::A new approach for the assessment of gait patterns is presented. The use of neural network techniques for decision making in gait analysis is for some purposes more effective than biomechanical methods or conventional statistics. To demonstrate this, a neural network was trained to distinguish 'healthy' from 'patholog...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90028-d

    authors: Holzreiter SH,Köhle ME

    更新日期:1993-06-01 00:00:00

  • Finite element modeling reveals complex strain mechanics in the aponeuroses of contracting skeletal muscle.

    abstract::A finite element model was used to investigate the counter-intuitive experimental observation that some regions of the aponeuroses of a loaded and contracting muscle may shorten rather than undergo an expected lengthening. The model confirms the experimental findings and suggests that pennation angle plays a significa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.01.005

    authors: Chi SW,Hodgson J,Chen JS,Reggie Edgerton V,Shin DD,Roiz RA,Sinha S

    更新日期:2010-05-07 00:00:00

  • Comparison of models for flow induced deformation of soft biological tissue.

    abstract::The behaviour of a deformable porous medium during the flow of fluid under a pressure difference is examined for both infinitesimal and finite deformations. Models for both cases are solved for the problem of steady one-dimensional compression and compared with experimental data from Parker et al. (J. appl. Mech. 54, ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90164-x

    authors: Barry SI,Aldis GK

    更新日期:1990-01-01 00:00:00

  • Effects of aging on hip abductor-adductor neuromuscular and mechanical performance during the weight transfer phase of lateral protective stepping.

    abstract::Aging brings about challenges in the ability to recover balance through protective stepping, especially in the lateral direction. Previous work has suggested that lateral protective stepping during weight transfer may be affected by impaired muscle composition and performance of the hip abductors (AB) in older adults....

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.10.040

    authors: Inacio M,Creath R,Rogers MW

    更新日期:2019-01-03 00:00:00

  • Location of minimum foot clearance on the shoe and with respect to the obstacle changes with locomotor task.

    abstract::Minimum foot clearance (MFC) as it relates to trips and falls has been extensively studied across many locomotor tasks, but examination of this body of research yields several studies with conflicting results and a wide range of MFCs within tasks. While there are several factors that may affect the MFC variability acr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.05.002

    authors: Loverro KL,Mueske NM,Hamel KA

    更新日期:2013-07-26 00:00:00

  • The role of the lamellar interface during torsional yielding of human cortical bone.

    abstract::Fragility fractures are a result of alterations in bone quantity, tissue properties, applied loads, or a combination of these factors. The current study addresses the contribution of cortical bone tissue properties to skeletal fragility by characterizing the shear damage accumulation processes which occur during torsi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00179-1

    authors: Jepsen KJ,Davy DT,Krzypow DJ

    更新日期:1999-03-01 00:00:00

  • Hydro-resistive measurement of dynamic lifting strength.

    abstract::A device is described for measuring strength and power outputs of dynamic vertical lifts between heights of 0.4 and 2.2 m. The device is safe, robust, and easily transportable. It consists of a water-filled tube 2 m high and 200 mm internal diameter. The subject pulls vertically on a handle which is connected with fle...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(96)00155-8

    authors: Pinder AD,Grieve DW

    更新日期:1997-04-01 00:00:00

  • Preload substantially influences the intervertebral disc stiffness in loading-unloading cycles of compression.

    abstract::Disc hydration is controlled by fluid imbibition and exudation and hence by applied load magnitude and history, internal osmotic pressure and disc conditions. It affects both the internal load distribution and external load-bearing of a disc while variations therein give rise to the disc time-dependent characteristics...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.05.006

    authors: Schmidt H,Shirazi-Adl A,Schilling C,Dreischarf M

    更新日期:2016-06-14 00:00:00

  • Age-related distensibility and histology of the ascending aorta in elderly patients with acute aortic dissection.

    abstract::Degradation and fragmentation of elastic fibers in the media dilate the aortic wall excessively in patients with acute Stanford type A aortic dissection (AD). Such dilatation occurs not via aortic stiffening, which is diagnosed using imaging under physiological loading, but due to the abovementioned intrinsic changes ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.06.025

    authors: Yamada H,Sakata N,Wada H,Tashiro T,Tayama E

    更新日期:2015-09-18 00:00:00

  • Model-based inverse estimation for active contraction stresses of tongue muscles using 3D surface shape in speech production.

    abstract::This paper presents a novel inverse estimation approach for the active contraction stresses of tongue muscles during speech. The proposed method is based on variational data assimilation using a mechanical tongue model and 3D tongue surface shapes for speech production. The mechanical tongue model considers nonlinear ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.09.008

    authors: Koike N,Ii S,Yoshinaga T,Nozaki K,Wada S

    更新日期:2017-11-07 00:00:00

  • A multipurpose muscle ergometer.

    abstract::A fast (0.1 mm steps within 2 ms), strong (40 N continuously) and accurate (resolution 0.002 N and 1.0 micron) muscle ergometer was developed to test dynamic and static properties of mammalian muscle. Both for twitches and for tetani isometric, isokinetic and isotonic contractions can be measured accurately. Force-vel...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90312-5

    authors: Woittiez RD,Brand C,de Haan A,Hollander AP,Huijing PA,van der Tak R,Rijnsburger WH

    更新日期:1987-01-01 00:00:00

  • Increased hip adduction during running is associated with patellofemoral pain and differs between males and females: A case-control study.

    abstract::Patellofemoral pain is common amongst recreational runners and associated with altered running kinematics. However, it is currently unclear how sex may influence kinematic differences previously reported in runners with patellofemoral pain. This case-control study aimed to evaluate lower limb kinematics in males and f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.05.014

    authors: Neal BS,Barton CJ,Birn-Jeffery A,Morrissey D

    更新日期:2019-06-25 00:00:00

  • Finite element investigation of the loading rate effect on the spinal load-sharing changes under impact conditions.

    abstract::Sudden deceleration and frontal/rear impact configurations involve rapid movements that can cause spinal injuries. This study aimed to investigate the rotation rate effect on the L2-L3 motion segment load-sharing and to identify which spinal structure is at risk of failure and at what rotation velocity the failure may...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.036

    authors: El-Rich M,Arnoux PJ,Wagnac E,Brunet C,Aubin CE

    更新日期:2009-06-19 00:00:00

  • Characterization of polyvinyl alcohol hydrogels as tissue-engineered cartilage scaffolds using a coupled finite element-optimization algorithm.

    abstract::Mechanical strength along with high biocompatibility and water absorbing are among main characteristics of a desirable scaffold for cartilage tissue engineering. Having these properties, polyvinyl alcohol (PVA) can be a good option for constructing cartilage tissue engineering scaffolds. In this study, PVA hydrogel wa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109525

    authors: Nazouri M,Seifzadeh A,Masaeli E

    更新日期:2020-01-23 00:00:00

  • Spatial phenotyping of the endocardial endothelium as a function of intracardiac hemodynamic shear stress.

    abstract::Despite substantial evidence for the central role of hemodynamic shear stress in the functional integrity of vascular endothelial cells, hemodynamic and molecular regulation of the endocardial endothelium lining the heart chambers remains understudied. We propose that regional differences in intracardiac hemodynamics ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.018

    authors: McCormick ME,Manduchi E,Witschey WRT,Gorman RC,Gorman JH 3rd,Jiang YZ,Stoeckert CJ Jr,Barker AJ,Yoon S,Markl M,Davies PF

    更新日期:2017-01-04 00:00:00

  • The effect of surface area digitizations on the prediction of spherical anatomical geometries for computer-assisted applications.

    abstract::Intraoperative digitization of osseous structures is an integral component of computer-assisted orthopaedic surgery. This study determined the repeatability and accuracy of predicting known radii and center locations of spherical objects for different proportions of digitized surface areas and various sphere sizes. Al...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.01.018

    authors: Whitney KD,Ferreira LM,King GJ,Johnson JA

    更新日期:2009-05-29 00:00:00

  • Relationships between femoral fracture loads for two load configurations.

    abstract::Studies of proximal femoral strength usually involve one of two types of loading conditions, loading similar to joint loading during single-limb stance or loading simulating impact from a fall. When interpreting the results of studies involving only one of these load configurations, the question arises as to their app...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00202-x

    authors: Keyak JH

    更新日期:2000-04-01 00:00:00

  • Influence of loading condition and anatomical location on human cortical bone linear micro-cracks.

    abstract::Human cortical bone fracture toughness depends on the anatomical locations under quasi-static loading. Recent results also showed that under fall-like loading, cortical bone fracture toughness is similar at different anatomical locations in the same donor. While cortical bone toughening mechanisms are known to be depe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.01.008

    authors: Gauthier R,Langer M,Follet H,Olivier C,Gouttenoire PJ,Helfen L,Rongiéras F,Mitton D,Peyrin F

    更新日期:2019-03-06 00:00:00

  • Dynamic stability of individuals with transtibial amputation walking in destabilizing environments.

    abstract::Lower limb amputation substantially disrupts motor and proprioceptive function. People with lower limb amputation experience considerable impairments in walking ability, including increased fall risk. Understanding the biomechanical aspects of the gait of these patients is crucial in improving their gait function and ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.02.033

    authors: Beurskens R,Wilken JM,Dingwell JB

    更新日期:2014-05-07 00:00:00

  • Compensation for inertial and gravity effects in a moving force platform.

    abstract::Force plates for human movement analysis provide accurate measurements when mounted rigidly on an inertial reference frame. Large measurement errors occur, however, when the force plate is accelerated, or tilted relative to gravity. This prohibits the use of force plates in human perturbation studies with controlled s...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.05.009

    authors: Hnat SK,van Basten BJH,van den Bogert AJ

    更新日期:2018-06-25 00:00:00

  • The influence of mechanical stimulus on the pattern of tissue differentiation in a long bone fracture--an FEM study.

    abstract::2D, coronal plane, finite elements models (FEMs) were developed from orthogonal radiographs of a diaphyseal tibial fracture and its reparative tissue at four different time points during healing. Each callus was separated into regions of common tissue histology by computerised radiographic analysis. Starting point val...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00189-x

    authors: Gardner TN,Stoll T,Marks L,Mishra S,Knothe Tate M

    更新日期:2000-04-01 00:00:00

  • Dynamic shear behavior of mandibular condylar cartilage is dependent on testing direction.

    abstract::Little information is available on the direction-dependency of shear behavior in mandibular condylar cartilage. Therefore, we tested the hypothesis that such a dependency of the dynamic shear properties is present in mandibular condylar cartilage. From each of 17 condyles, two cartilage-bone plugs were dissected and t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.12.012

    authors: Tanaka E,Iwabuchi Y,Rego EB,Koolstra JH,Yamano E,Hasegawa T,Kawazoe A,Kawai N,Tanne K

    更新日期:2008-01-01 00:00:00

  • Does cancellous screw insertion torque depend on bone mineral density and/or microarchitecture?

    abstract::During insertion of a cancellous bone screw, the torque level reaches a plateau, at the engagement of all the screw threads prior to the screw head contact. This plateau torque (T(Plateau)) was found to be a good predictor of the insertion failure torque (stripping) and also exhibited strong positive correlations with...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.11.030

    authors: Ab-Lazid R,Perilli E,Ryan MK,Costi JJ,Reynolds KJ

    更新日期:2014-01-22 00:00:00

  • Fracture analysis for biological materials with an expanded cohesive zone model.

    abstract::In this study, a theoretical framework for simulation of fracture of bone and bone-like materials is provided. An expanded cohesive zone model with thermodynamically consistent framework has been proposed and used to investigate the crack growth resistance of bone and bone-like materials. The reversible elastic deform...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.04.054

    authors: An B,Zhao X,Arola D,Zhang D

    更新日期:2014-07-18 00:00:00

  • Non-interacting modes for stress, strain and energy in anisotropic hard tissue.

    abstract::The six non-interacting modes for stress, strain and energy in an orthotropic elastic model of human femoral cortical bone tissue are discussed and illustrated. The stress and strain modes are illustrated using the representation of the stress and strain fields around a circular hole in a flat plate of cortical bone s...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90311-a

    authors: Cowin SC,Sadegh AM

    更新日期:1991-01-01 00:00:00

  • Thickness, cross-sectional area, and stiffness of intrinsic foot muscles affect performance in single-leg stance balance tests in healthy sedentary young females.

    abstract::The purpose of this study was to investigate the effect of thickness, cross-sectional area and stiffness of intrinsic foot muscles on performance in single-leg stance balance tasks in healthy sedentary young females. This study included a total of 40 healthy sedentary young females between the ages of 19 and 35 years....

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109530

    authors: Taş S,Ünlüer NÖ,Çetin A

    更新日期:2020-01-23 00:00:00

  • Computational musculoskeletal modeling of compensatory movements in the upper limb.

    abstract::It is well documented that most upper limb amputees utilize compensatory movement strategies to accomplish everyday tasks when using a prosthetic device and that musculoskeletal complaints (MSCs) are more common in this population. However, little information is available on how the loss of distal degrees of freedom (...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109843

    authors: Reilly M,Kontson K

    更新日期:2020-07-17 00:00:00