Sensitivity of a Hill-based muscle model to perturbations in model parameters.

Abstract:

:Musculoskeletal simulations of human movement commonly use Hill muscle models to predict muscle forces, but their sensitivity to model parameter values is not well understood. The purpose of this study was to evaluate muscle model sensitivity to perturbations in 14 Hill muscle model parameters in forward dynamic simulations of running and walking by varying each by +/-50%. Three evaluations of the muscle model were performed based on: (1) calculating the sensitivity of the muscle model only, (2) determining the continuous partial derivatives of the muscle equations with respect to each parameter, and (3) evaluating the effects on the running and walking simulations. Model evaluations were found to be very sensitive (percent change in outputs greater than parameter perturbation) to parameters defining the series elastic component (tendon), force-length curve of the contractile element and maximum isometric force. For some parameters, the range of literature values was larger than the model sensitivity. Model evaluations were insensitive to parameters defining the parallel elastic element, force-velocity curve of the contractile element and muscle activation time constants. The derivative method provided similar results, but also provided a generic, continuous equation that can easily be applied to other motions. The sensitivities of the running and walking simulations were reduced compared to the sensitivity of the muscle model alone. Results demonstrate the importance of evaluating sensitivity of a musculoskeletal simulation in a controlled manner and provide an indication of which parameters must be selected most carefully based on the sensitivity of a given movement.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Scovil CY,Ronsky JL

doi

10.1016/j.jbiomech.2005.06.005

keywords:

subject

Has Abstract

pub_date

2006-01-01 00:00:00

pages

2055-63

issue

11

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(05)00277-0

journal_volume

39

pub_type

杂志文章
  • A computer-controlled mechanical culture system for biological testing of articular cartilage explants.

    abstract::A computer-controlled mechanical culture system was designed to investigate the interaction between mechanical stimuli and the metabolism of articular cartilage. The main features of this system include the following capabilities: (1) Accurately controlled static, permanent cyclic or intermittent cyclic mechanical loa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00040-7

    authors: Steinmeyer J

    更新日期:1997-08-01 00:00:00

  • Walking at the preferred stride frequency maximizes local dynamic stability of knee motion.

    abstract::Healthy humans display a preference for walking at a stride frequency dependent on the inertial properties of their legs. Walking at preferred stride frequency (PSF) is predicted to maximize local dynamic stability, whereby sensitivity to intrinsic perturbations arising from natural variability inherent in biological ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.10.012

    authors: Russell DM,Haworth JL

    更新日期:2014-01-03 00:00:00

  • Laterality in the gallop gait of horses.

    abstract::Bilateral asymmetry in gallop stride limb contact patterns of four Quarter Horse fillies was documented by high-speed cinematography. Horses were filmed with rider by two cameras simultaneously while galloping along a straightaway. Even though signaled for each gallop lead an equivalent number of times, horses frequen...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90285-5

    authors: Deuel NR,Lawrence LM

    更新日期:1987-01-01 00:00:00

  • Impact-induced osteochondral fracture in the tibial plateau.

    abstract::In this study, human tibia plateaus with the meniscus removed were impacted on various regions of the plateau surface via a drop test using a 5mm indenter. Osteochondral blocks containing the failure site were then extracted, chemically fixed, dehydrated, gold-particle coated, and sent for X-ray micro-CT imaging to ob...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.01.033

    authors: Thambyah A,Shim VP,Chong LM,Lee VS

    更新日期:2008-01-01 00:00:00

  • Changes of opening angle in hypertensive and hypotensive arteries in 3-day organ culture.

    abstract::To study the effect of pressure changes on the opening angle of arteries in organ culture, tubular segments of porcine common carotid arteries were cultured with pulsatile flow perfusion under hypertensive (150+/-20 mmHg), normotensive (100+/-20 mmHg), or hypotensive (30+/-10 mmHg) pressure while maintaining the arter...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.08.003

    authors: Han HC,Marita S,Ku DN

    更新日期:2006-01-01 00:00:00

  • Microdamage evaluation in human trabecular bone based on nonlinear ultrasound vibro-modulation (NUVM).

    abstract::The primary aim of this work is to investigate the potential of nonlinear ultrasound for microdamage detection in human bone. Microdamage evaluation in human bone is of great importance, because it is considered a significant parameter for characterizing fracture risk. Experiments employing nonlinear acoustic vibro-mo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.12.018

    authors: Zacharias K,Balabanidou E,Hatzokos I,Rekanos IT,Trochidis A

    更新日期:2009-03-26 00:00:00

  • Untangling biomechanical differences in perturbation-induced stepping strategies for lateral balance stability in older individuals.

    abstract::When recovering balance from a lateral perturbation, younger adults tend to stabilize balance with a single lateral sidestep while older adults often take multistep responses. Using multiple steps to recover balance is consistently associated with increased fall risk, altered body center of mass (CoM) control and inst...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110161

    authors: Borrelli J,Creath R,Gray VL,Rogers MW

    更新日期:2021-01-04 00:00:00

  • The effects of -80 °C short-term storage on the mechanical response of tricuspid valve leaflets.

    abstract::Mechanical testing of soft tissues would ideally rely on using fresh specimens. In the event that fresh tissues are not readily available, alternative measures, such as storing fresh specimens at -80 °C, could be considered. Previous studies have shown that changes in the mechanical properties of the tissues due to fr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109462

    authors: Salinas SD,Clark MM,Amini R

    更新日期:2020-01-02 00:00:00

  • Jet collisions and vortex reversal in the human left ventricle.

    abstract::Unnatural dynamics of the notorious vortex in the left ventricle is often associated with cardiac disease. Understanding how different cardiac diseases alter the flow physics in the left ventricle may therefore provide a powerful tool for disease detection. In this work, the fluid dynamics in the left ventricle subjec...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.07.023

    authors: Di Labbio G,Kadem L

    更新日期:2018-09-10 00:00:00

  • On stiffness of scaffolds for bone tissue engineering-a numerical study.

    abstract::Tissue scaffolds are typically designed and fabricated to match native bone properties. However, it is unclear if this would lead to the best tissue ingrowth outcome within the scaffold as neo-tissue keeps changing the stiffness of entire construct. This paper presents a numerical method to address this issue for desi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.02.020

    authors: Sturm S,Zhou S,Mai YW,Li Q

    更新日期:2010-06-18 00:00:00

  • Effect of cracks on the local deformations of articular cartilage.

    abstract::Despite significant evidence regarding the increased risk of cartilage degeneration due to traumatic injuries to joints, there is still a lack of understanding of the mechanisms underlying osteoarthritis development following a joint injury. Injuries in knee cartilage are often characterized by lesions or tears. In ad...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109970

    authors: Komeili A,Luqman S,Federico S,Herzog W

    更新日期:2020-09-18 00:00:00

  • Hospital bed height influences biomechanics during bed egress: A comparative controlled study of patients with Parkinson disease.

    abstract::Although a significant proportion of patient falls occur during egress from the hospital bed, the biomechanical adaptations during egress from different bed heights are still largely unknown. The purpose of this study was to evaluate the effect of hospital bed height on natural transition during egress in patients wit...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110116

    authors: Xu H,Li X,Shi Y,An L,Taylor D,Christman M,Morse J,Merryweather A

    更新日期:2021-01-22 00:00:00

  • Simultaneous positive and negative external mechanical work in human walking.

    abstract::In human walking, the center of mass motion is similar to an inverted pendulum. Viewing double support as a transition from one inverted pendulum to the next, we hypothesized that the leading leg performs negative work to redirect the center of mass velocity, while simultaneously, the trailing leg performs positive wo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00169-5

    authors: Donelan JM,Kram R,Kuo AD

    更新日期:2002-01-01 00:00:00

  • Hip endoprosthesis for in vivo measurement of joint force and temperature.

    abstract::Friction between the prosthetic head and acetabular cup increases the temperature in hip implants during activities like walking. A hip endoprosthesis was instrumented with sensors to measure the joint contact forces and the temperature distribution along the entire length of the titanium implant. Sensors and two indu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00110-4

    authors: Graichen F,Bergmann G,Rohlmann A

    更新日期:1999-10-01 00:00:00

  • Motor unit acceleration maps and interference mechanomyographic distribution.

    abstract::The study analyses the two-dimensional distribution of surface mechanomyographic (MMG) signal generated by the activation of single motor units located in three transverse positions in the tibialis anterior muscle. In 12 healthy volunteers, surface MMG signals were recorded from the tibialis anterior muscle with a 3 x...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.07.007

    authors: Farina D,Li X,Madeleine P

    更新日期:2008-09-18 00:00:00

  • Model of muscle-tendon interaction during frog semitendinosis fixed-end contractions.

    abstract::A structural model was developed to explain sarcomere shortening at the expense of tendon lengthening in the frog semitendinosis (ST) muscle-tendon system. The model was based on the data of Lieber et al. [Am. J. Physiol. 261, C86-C92 (1991)], who determined the relationship between the sarcomere length, tendon load (...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90261-x

    authors: Lieber RL,Brown CG,Trestik CL

    更新日期:1992-04-01 00:00:00

  • Effects of extracellular fiber architecture on cell membrane shear stress in a 3D fibrous matrix.

    abstract::Interstitial fluid flow has been shown to affect the organization and behavior of cells in 3D environments in vivo and in vitro, yet the forces driving such responses are not clear. Due to the complex architecture of the extracellular matrix (ECM) and the difficulty of measuring fluid flow near cells embedded in it, t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.06.023

    authors: Pedersen JA,Boschetti F,Swartz MA

    更新日期:2007-01-01 00:00:00

  • Differences between measured and resultant joint moments during isometric contractions at the ankle joint.

    abstract::The purpose of this study was to examine two hypotheses: (a) during voluntary and electrically induced isometric contractions the moments measured at the dynamometer are different from the resultant moments in the same plane around the ankle joint and (b) at a given resultant moment during electrically induced isometr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.04.027

    authors: Arampatzis A,Morey-Klapsing G,Karamanidis K,DeMonte G,Stafilidis S,Brüggemann GP

    更新日期:2005-04-01 00:00:00

  • Influence of erythrocyte aggregation on radial migration of platelet-sized spherical particles in shear flow.

    abstract::Blood platelets when activated are involved in the mechanisms of hemostasis and thrombosis, and their migration toward injured vascular endothelium necessitates interaction with red blood cells (RBCs). Rheology co-factors such as a high hematocrit and a high shear rate are known to promote platelet mass transport towa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.06.044

    authors: Guilbert C,Chayer B,Allard L,Yu FTH,Cloutier G

    更新日期:2017-08-16 00:00:00

  • Effect of LIMK2 RNAi on reorganization of the actin cytoskeleton in osteoblasts induced by fluid shear stress.

    abstract::The biomechanical characteristics of bone tissue and its cells under mechanical stress are significant for bone biomechanics research, but the mechanism of mechanotransduction is still unknown. It has been established that the actin cytoskeleton of osteoblasts plays an important role in this process. However, the stru...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.08.010

    authors: Fu Q,Wu C,Shen Y,Zheng S,Chen R

    更新日期:2008-11-14 00:00:00

  • An actuated dissipative spring-mass walking model: Predicting human-like ground reaction forces and the effects of model parameters.

    abstract::Simple models are widely used to understand the mechanics of human walking. The optimization-based minimal biped model and spring-loaded-inverted-pendulum (SLIP) model are two popular models that can achieve human-like walking patterns. However, ground reaction forces (GRF) from these two models still deviate from exp...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.04.028

    authors: Li T,Li Q,Liu T

    更新日期:2019-06-11 00:00:00

  • Control of dynamic foot-ground interactions in male and female soccer athletes: females exhibit reduced dexterity and higher limb stiffness during landing.

    abstract::Controlling dynamic interactions between the lower limb and ground is important for skilled locomotion and may influence injury risk in athletes. It is well known that female athletes sustain anterior cruciate ligament (ACL) tears at higher rates than male athletes, and exhibit lower extremity biomechanics thought to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.10.038

    authors: Lyle MA,Valero-Cuevas FJ,Gregor RJ,Powers CM

    更新日期:2014-01-22 00:00:00

  • Vastus lateralis and vastus medialis produce distinct mediolateral forces on the patella but similar forces on the tibia in the rat.

    abstract::Improper activation of the quadriceps muscles vastus medialis (VM) and vastus lateralis (VL) has been implicated in the development of patellofemoral pain (PFP). This explanation of PFP assumes that VM and VL produce opposing mediolateral forces on the patella. Although studies have provided evidence for opposing acti...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.09.007

    authors: Sandercock TG,Wei Q,Dhaher YY,Pai DK,Tresch MC

    更新日期:2018-11-16 00:00:00

  • In vitro analysis of a model of intracardiac jet: analysis of the central core of axisymmetric jets.

    abstract::In order to provide physical information supporting the clinical use of flow mapping, an in vitro model was designed to measure the velocity fields in a pulsatile hydraulic turbulent jet. We used a peak velocity ranging from 2.5 to 5.5 m.s-1, an orifice diameter ranging from 5.8 to 11.3 mm and confined the jet in a re...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90367-c

    authors: Diebold B,Delouche A,Dumée P,Guglielmi JP,Delouche P,Péronneau P

    更新日期:1990-01-01 00:00:00

  • Propulsion biomechanics do not differ between athletic and nonathletic manual wheelchair users in their daily wheelchairs.

    abstract::The purpose of this study was to investigate whether athletic and nonathletic manual wheelchair users (MWU) display differences in kinetic and kinematic variables during daily wheelchair propulsion. Thirty-nine manual wheelchair users (athletic n = 25; nonathletic n = 14) propelled their own daily living wheelchair on...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109725

    authors: Briley SJ,Vegter RJK,Tolfrey VL,Mason BS

    更新日期:2020-05-07 00:00:00

  • Passive muscle mechanical properties of the medial gastrocnemius in young adults with spastic cerebral palsy.

    abstract::Individuals with spastic cerebral palsy (SCP) exhibit restricted joint range of motion and increased joint stiffness due to structural alterations of their muscles. Little is known about which muscle-tendon structures are responsible for these alterations. The aim of this study was to compare the passive mechanics of ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.06.008

    authors: Barber L,Barrett R,Lichtwark G

    更新日期:2011-09-02 00:00:00

  • Density of trunk tissues of young and medium age people.

    abstract::In this study the investigations made on about 50 trunk tissue densities are described. They were performed on ten cadavers of both sexes within 24 h of the moment of death. They were 20-40 yr old. The weight of each tissue was measured on a laboratory scale and the volume by placing the tissue in a pycnometer filled ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90360-f

    authors: Erdmann WS,Gos T

    更新日期:1990-01-01 00:00:00

  • In vivo porcine left atrial wall stress: Effect of ventricular tachypacing on spatial and temporal stress distribution.

    abstract::Animal models of ventricular tachypacing (VTP) have been successfully used to reproduce the relevant features observed in patients with atrial fibrillation, such as increased atrial pressure and volume, ion-channel alterations and fibrosis. After performing VTP on a healthy Yorkshire pig, we measured an increase in vo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.09.003

    authors: Di Martino ES,Bellini C,Schwartzman DS

    更新日期:2011-11-10 00:00:00

  • Foot contact identification using a single triaxial accelerometer during running.

    abstract::The analysis of in-field biomechanics data typically requires the identification of foot contact. Existing techniques to identify foot contact using accelerometers offer a viable option for identifying foot contact in the field. However, these techniques often require the placement of additional accelerometers or the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109768

    authors: Aubol KG,Milner CE

    更新日期:2020-05-22 00:00:00

  • Chest response assessment of post-mortem swine under blast loadings.

    abstract::To better protect soldiers from blast threat, that principally affect air-filled organs such a lung, it is necessary to develop an adapted injury criterion and, prior to this, to evaluate the response of a biological model against that threat. The objective of this study is to provide some robust data to quantify the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.10.012

    authors: Boutillier J,De Mezzo S,Deck C,Magnan P,Naz P,Willinger R

    更新日期:2017-12-08 00:00:00