Ulceration, unsteadiness, and uncertainty: the biomechanical consequences of diabetes mellitus.

Abstract:

:Diabetes mellitus, which results from a failure of the endocrine system to control blood glucose levels within normal limits, affects approximately 15% of the population over the age of 65 in developed countries. Between 20-50% of people with diabetes for more than 10 years will experience symmetrical distal sensory neuropathy resulting in a progressive, distal to proximal, loss of sensation in the lower extremities. The most common consequence is plantar ulceration that too often results in partial or total amputation of the foot. While neuropathy is a major permissive factor, plantar ulcers occur at locations of high plantar pressures. The measurement of pressure using tools developed and refined in the field of biomechanics has been shown to be a valuable asset to the management of the foot at risk for ulceration. In particular, the use of in-shoe measuring techniques has the potential to revolutionize the prescription of therapeutic footwear. Biomechanical techniques have also helped to evaluate other consequences of diabetic neuropathy on the foot such as callus formation, foot deformity, limited joint mobility and bony abnormalities. The reduction of afferent information from the lower extremities implies a lack of active feedback thought to be necessary for the control of human movements such as posture and gait. Our results show that diabetic neuropathy results in a significant increase in sway during standing that is not compensated for by other sensory systems. The study of the sagittal plane movements of the same individuals walking on a treadmill showed little effect on the kinematic control of gait when compared to age matched nonneuropathic control groups. This may indicate the dominance of efferent input over afferent feedback during gait. We believe that the study of the biomechanical consequences of diabetes can act as a model for many other diseases that have yet to come under the scrutiny of a multidisciplinary team.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Cavanagh PR,Simoneau GG,Ulbrecht JS

doi

10.1016/0021-9290(93)90077-r

subject

Has Abstract

pub_date

1993-01-01 00:00:00

pages

23-40

eissn

0021-9290

issn

1873-2380

pii

0021-9290(93)90077-R

journal_volume

26 Suppl 1

pub_type

杂志文章,评审
  • In vivo kinematics and articular surface congruency of total ankle arthroplasty during gait.

    abstract::Relatively high rates of loosening and implant failure have been reported after total ankle arthroplasty. Abnormal kinematics and incongruency of the articular surface may cause increased contact pressure and rotational torque applied to the implant, leading to loosening and implant failure. We measured in vivo kinema...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.05.043

    authors: Yamaguchi S,Tanaka Y,Banks S,Kosugi S,Sasho T,Takahashi K,Takakura Y

    更新日期:2012-08-09 00:00:00

  • Influences of spherical tip radius, contact depth, and contact area on nanoindentation properties of bone.

    abstract::Nanoindentation has been widely used as a means to measure the micro-mechanical properties of bone and to predict the macroscopic properties. The role of indent depth and indenter tip geometry in measuring the hierarchical properties of bone tissue was explored experimentally using a range of spherical indenter tips o...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.10.008

    authors: Paietta RC,Campbell SE,Ferguson VL

    更新日期:2011-01-11 00:00:00

  • Confocal-based cell-specific finite element modeling extended to study variable cell shapes and intracellular structures: the example of the adipocyte.

    abstract::This communication extends the recently reported cell-specific finite element (FE) method in Slomka and Gefen (2010) in which geometrically realistic FE cell models are created from confocal microscopy scans for large deformation analyses. The cell-specific FE method is extended here in the following aspects: (i) we d...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.09.012

    authors: Or-Tzadikario S,Gefen A

    更新日期:2011-02-03 00:00:00

  • Evaluation of left ventricular function based on simulated systolic flow dynamics computed from regional wall motion.

    abstract::Left ventricular (LV) chamber flow is undoubtedly influenced by the time-dependent regional motion of the LV wall. In an attempt to obtain diagnostic parameters based on LV chamber flow, we computed the LV chamber, two-dimensional systolic velocity and pressure distribution for two right anterior oblique (RAO) ventric...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90201-1

    authors: Schoephoerster RT,Silva CL,Ray G

    更新日期:1994-02-01 00:00:00

  • Mechanical and geometrical properties of the rat semimembranosus lateralis muscle during isometric contractions.

    abstract::The orientation of the line of pull and geometrical characteristics of rat semimembranosus lateralis muscle (SM1) were measured in a plane during isometric contractions at different muscle lengths. The orientation of the line of pull was always similar in our plane of analysis. It was always aligned with the external ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90051-5

    authors: Willems ME,Huijing PA

    更新日期:1994-09-01 00:00:00

  • Quantitative detection of cartilage surfaces and ligament geometry of the wrist using an imaging cryomicrotome system.

    abstract::Biomechanical models may aid in improving diagnosis and treatment of wrist joint disorders. As input, geometrical information is required for model development. Previous studies acquired some elements of the average wrist joint geometry. However, there is a close geometric functional match between articulating surface...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.11.003

    authors: Dvinskikh NA,Blankevoort L,Foumani M,Spaan JA,Streekstra GJ

    更新日期:2010-03-22 00:00:00

  • Numerical modelling of mass transport in an arterial wall with anisotropic transport properties.

    abstract::Coronary artery disease results in blockages or narrowing of the artery lumen. Drug eluting stents (DES) were developed to replace bare metal stents in an effort to combat re-blocking of the diseased artery following treatment. The numerical models developed within this study focus on representing the changing trends ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.09.017

    authors: Denny WJ,Walsh MT

    更新日期:2014-01-03 00:00:00

  • Low-back loading in lifting two loads beside the body compared to lifting one load in front of the body.

    abstract::Low-back load during manual lifting is considered an important risk factor for the occurrence of low-back pain. Splitting a load, so it can be lifted beside the body (one load in each hand), instead of in front of the body, can be expected to reduce low-back load. Twelve healthy young men lifted 10 and 20-kg wide and ...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2008.10.013

    authors: Faber GS,Kingma I,Bakker AJ,van Dieën JH

    更新日期:2009-01-05 00:00:00

  • A theoretical model of the effect of continuum damage on a bone adaptation model.

    abstract::Throughout life, bone is continuously turning over by the well-regulated processes of bone formation and resorption. Everyday activities damage bone, and this damage is normally repaired in a continuous remodelling process. When an imbalance in this remodelling process occurs, bones may become more susceptible to frac...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00215-3

    authors: Ramtani S,Zidi M

    更新日期:2001-04-01 00:00:00

  • On the anisotropy of the canine diaphragmatic central tendon.

    abstract::We studied the mechanical and anatomical anisotropy of the canine diaphragmatic central tendon (CT). Dumb-bell-shaped strips with effective dimensions of 10 x 2 mm (length x width) were cut from different regions of the canine diaphragmatic CT in two different orientations relative to the direction of neighboring musc...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90289-y

    authors: Chuong CJ,Sacks MS,Johnson RL Jr,Reynolds R

    更新日期:1991-01-01 00:00:00

  • Loads on an internal spinal fixation device during sitting.

    abstract::Sitting is often assumed to involve high loads on the spine as well as on implants for stabilising the spine. Loads on internal spinal fixation devices were therefore measured in ten patients sitting on several types of seats, including a stool, a stool with a padded wedge, a chair, a physiotherapy ball, a knee-stool,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00073-2

    authors: Rohlmann A,Arntz U,Graichen F,Bergmann G

    更新日期:2001-08-01 00:00:00

  • Representing and identifying alternative movement techniques for goal-directed manual tasks.

    abstract::Differences in motion patterns subserving the same movement goal can be identified qualitatively. These alternatives, which may characterize 'movement techniques' (e.g., the stoop and the squat lifting technique), may be associated with significantly different biomechanical constraints and physiological responses. Des...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.04.014

    authors: Park W,Martin BJ,Choe S,Chaffin DB,Reed MP

    更新日期:2005-03-01 00:00:00

  • Experimental measurement and quantification of frictional contact between biological surfaces experiencing large deformation and slip.

    abstract::Interactions between contacting biological surfaces may play significant roles in physiological and pathological processes. Theoretical models have described some special cases of contact, using one or more simplifying assumptions. Experimental quantification of contact could help to validate theoretical analyses. The...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.01.006

    authors: Gratz KR,Sah RL

    更新日期:2008-01-01 00:00:00

  • Effect of material damping on bone remodelling.

    abstract::This paper considers the effect of internal material damping on the stresses, strains, and surface and internal remodelling behaviour in a section of axisymmetrical bone with a force-fitted axially oriented medullary pin. The bone response to several loading situations is modelled using visco-elastic equations. An app...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90291-0

    authors: Misra JC,Samanta S

    更新日期:1987-01-01 00:00:00

  • Non-invasive quantification of peripheral arterial volume distensibility and its non-linear relationship with arterial pressure.

    abstract::Arterial wall function is associated with different physiological and clinical factors. Changes in arterial pressure cause major changes in the arterial wall. This study presents a simple non-invasive method to quantify arterial volume distensibility changes with different arterial pressures. The electrocardiogram, fi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.02.011

    authors: Zheng D,Murray A

    更新日期:2009-05-29 00:00:00

  • Robotic simulation of identical athletic-task kinematics on cadaveric limbs exhibits a lack of differences in knee mechanics between contralateral pairs.

    abstract::Limb asymmetry is a known factor for increased ACL injury risk. These asymmetries are normally observed during in vivo testing. Prior studies have developed in vitro testing methodologies driven by in vivo kinematics to investigate knee mechanics relative to ACL injury. The objective of this study was to determine if ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.12.019

    authors: Bates NA,McPherson AL,Nesbitt RJ,Shearn JT,Myer GD,Hewett TE

    更新日期:2017-02-28 00:00:00

  • Age-related distensibility and histology of the ascending aorta in elderly patients with acute aortic dissection.

    abstract::Degradation and fragmentation of elastic fibers in the media dilate the aortic wall excessively in patients with acute Stanford type A aortic dissection (AD). Such dilatation occurs not via aortic stiffening, which is diagnosed using imaging under physiological loading, but due to the abovementioned intrinsic changes ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.06.025

    authors: Yamada H,Sakata N,Wada H,Tashiro T,Tayama E

    更新日期:2015-09-18 00:00:00

  • Stone comminution correlates with the average peak pressure incident on a stone during shock wave lithotripsy.

    abstract::To investigate the roles of lithotripter shock wave (LSW) parameters and cavitation in stone comminution, a series of in vitro fragmentation experiments have been conducted in water and 1,3-butanediol (a cavitation-suppressive fluid) at a variety of acoustic field positions of an electromagnetic shock wave lithotripte...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.07.025

    authors: Smith N,Zhong P

    更新日期:2012-10-11 00:00:00

  • Effects of short-term recovery periods on fluid-induced signaling in osteoblastic cells.

    abstract::It is well known that cyclic mechanical loading can produce an anabolic response in bone. In vivo studies have shown that the insertion of short-term recovery periods (10-15 s) into mechanical loading profiles led to an increased osteogenic response compared to continuous cyclic loading of bone. Although this is sugge...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.08.009

    authors: Batra NN,Li YJ,Yellowley CE,You L,Malone AM,Kim CH,Jacobs CR

    更新日期:2005-09-01 00:00:00

  • Growth and surface folding of esophageal mucosa: a biomechanical model.

    abstract::Mucosal folding in such biological vessels as esophagus and airway is essential to their physiological functions and can be affected by some diseases, e.g., inflammation, edema, lymphoma, and asthma. A biomechanical model within the framework of finite deformation theory is proposed to address the mucosal folding indu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.09.007

    authors: Li B,Cao YP,Feng XQ

    更新日期:2011-01-04 00:00:00

  • Multiple-step model-experiment matching allows precise definition of dynamical leg parameters in human running.

    abstract::The spring-loaded inverted pendulum (SLIP) model is a well established model for describing bouncy gaits like human running. The notion of spring-like leg behavior has led many researchers to compute the corresponding parameters, predominantly stiffness, in various experimental setups and in various ways. However, dif...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.06.030

    authors: Ludwig C,Grimmer S,Seyfarth A,Maus HM

    更新日期:2012-09-21 00:00:00

  • The human ankle during walking: implications for design of biomimetic ankle prostheses.

    abstract::The non-disabled human ankle joint was examined during walking in an attempt to determine overall system characteristics for use in the design of ankle prostheses. The hypothesis of the study was that the quasi-stiffness of the ankle changes when walking at different walking speeds. The hypothesis was examined using s...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.01.017

    authors: Hansen AH,Childress DS,Miff SC,Gard SA,Mesplay KP

    更新日期:2004-10-01 00:00:00

  • Comparison of models for flow induced deformation of soft biological tissue.

    abstract::The behaviour of a deformable porous medium during the flow of fluid under a pressure difference is examined for both infinitesimal and finite deformations. Models for both cases are solved for the problem of steady one-dimensional compression and compared with experimental data from Parker et al. (J. appl. Mech. 54, ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90164-x

    authors: Barry SI,Aldis GK

    更新日期:1990-01-01 00:00:00

  • Model studies of the flow in abdominal aortic aneurysms during resting and exercise conditions.

    abstract::Pulsatile flow in abdominal aortic aneurysm (AAA) models has been examined in order to understand the hemodynamics that may contribute to growth of an AAA. The model studies were conducted by experiments (flow visualization and laser Doppler velocimetry) and by numerical simulation using physiologically realistic rest...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00134-7

    authors: Egelhoff CJ,Budwig RS,Elger DF,Khraishi TA,Johansen KH

    更新日期:1999-12-01 00:00:00

  • In vitro analysis of a model of intracardiac jet: analysis of the central core of axisymmetric jets.

    abstract::In order to provide physical information supporting the clinical use of flow mapping, an in vitro model was designed to measure the velocity fields in a pulsatile hydraulic turbulent jet. We used a peak velocity ranging from 2.5 to 5.5 m.s-1, an orifice diameter ranging from 5.8 to 11.3 mm and confined the jet in a re...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90367-c

    authors: Diebold B,Delouche A,Dumée P,Guglielmi JP,Delouche P,Péronneau P

    更新日期:1990-01-01 00:00:00

  • An in vitro experimental study on the relationship between pulsatile tinnitus and the dehiscence/thinness of sigmoid sinus cortical plate.

    abstract::Pulsatile tinnitus (PT), characterized as pulse-synchronous, is generally objective. Sigmoid sinus (SS) venous sound is widely suggested to be a possible sound source of PT. The dehiscence and thinness of SS cortical plate (CP) was commonly reported as PT pathology in previous studies, but lack quantitative or biomech...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.12.049

    authors: Tian S,Fan X,Wang Y,Liu Z,Wang L

    更新日期:2019-02-14 00:00:00

  • Measuring strain using digital image correlation of second harmonic generation images.

    abstract::The micromechanical environment of bone is crucial to understanding both bone fracture and mechanobiological responses of osteocytes, yet few techniques exist that are capable of measuring strains on the micrometer scale. A method for measuring micrometer level strains has been developed based on digital image correla...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.06.003

    authors: Wentzell S,Sterling Nesbitt R,Macione J,Kotha S

    更新日期:2013-08-09 00:00:00

  • Microdamage accumulation in the cement layer of hip replacements under flexural loading.

    abstract::Mechanical fatigue of bone cement leading to damage accumulation is implicated in the loosening of cemented hip components. Even though cracks have been identified in autopsy-retrieved mantles, damage accumulation by continuous growth and increase in number of microcracks has not yet been demonstrated experimentally. ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00018-4

    authors: McCormack BA,Prendergast PJ

    更新日期:1999-05-01 00:00:00

  • Evaluation of the superficial characteristics of articular cartilage using evanescent waves in the friction tests with intermittent sliding and loading.

    abstract::Articular cartilage plays an important role in the lubrication of synovial joints because of its peculiar characteristics. In this work, the frictional and superficial characteristics of articular cartilage were evaluated simultaneously during intermittent sliding and loading. The apparatus used for the analysis of th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.06.015

    authors: Naka MH,Hattori K,Ikeuchi K

    更新日期:2006-01-01 00:00:00

  • Comparison of marker models for the analysis of the volume variation and thoracoabdominal motion pattern in untrained and trained participants.

    abstract::Respiratory assessment and the biomechanical analysis of chest and abdomen motion during breathing can be carried out using motion capture systems. An advantage of this methodology is that it allows analysis of compartmental breathing volumes, thoraco-abdominal patterns, percentage contribution of each compartment and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.05.036

    authors: Massaroni C,Piaia Silvatti A,Levai IK,Dickinson J,Winter S,Schena E,Silvestri S

    更新日期:2018-07-25 00:00:00