Quantitative detection of cartilage surfaces and ligament geometry of the wrist using an imaging cryomicrotome system.

Abstract:

:Biomechanical models may aid in improving diagnosis and treatment of wrist joint disorders. As input, geometrical information is required for model development. Previous studies acquired some elements of the average wrist joint geometry. However, there is a close geometric functional match between articulating surfaces and ligament geometry. Therefore, biomechanical models need to be fed with the geometric data of individual joints. This study is aimed at acquiring geometric data of cartilage surfaces and ligaments from individual wrist joints by using a cryomicrotome imaging system and the evaluation of inter- and intra-observer variability of the data. The 3D geometry of 30 cartilage surfaces and 15 ligaments in three cadaver wrists was manually detected and quantitatively reconstructed. The inter- and intra-observer variability of the cartilage surface detection was 0.14 and 0.19 mm, respectively. For the position of the radius attachment of the dorsal radiocarpal ligament (DRC), the observer variations were 0.12 and 0.65 mm, for intra-/inter-observer, respectively. For the DRC attachment on the triquetrum, the observer variations were 0.22 and 1.19 mm. Anatomic reconstruction from 3D cryomicrotome images offer a method to obtain unique geometry data of the entire wrist joint for modeling purposes.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Dvinskikh NA,Blankevoort L,Foumani M,Spaan JA,Streekstra GJ

doi

10.1016/j.jbiomech.2009.11.003

subject

Has Abstract

pub_date

2010-03-22 00:00:00

pages

1007-10

issue

5

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(09)00636-8

journal_volume

43

pub_type

杂志文章
  • A piecewise mass-spring-damper model of the human breast.

    abstract::Previous models to predict breast movement whilst performing physical activities have, erroneously, assumed uniform elasticity within the breast. Consequently, the predicted displacements have not yet been satisfactorily validated. In this study, real time motion capture of the natural vibrations of a breast that foll...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.11.027

    authors: Cai Y,Chen L,Yu W,Zhou J,Wan F,Suh M,Chow DH

    更新日期:2018-01-23 00:00:00

  • Influence of microcalcifications on vulnerable plaque mechanics using FSI modeling.

    abstract::Sudden heart attacks remain one of the primary causes of premature death in the developed world. Asymptomatic vulnerable plaques that rupture are believed to prompt such fatal heart attacks and strokes. The role of microcalcifications in the vulnerable plaque rupture mechanics is still debated. Recent studies suggest ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.11.029

    authors: Bluestein D,Alemu Y,Avrahami I,Gharib M,Dumont K,Ricotta JJ,Einav S

    更新日期:2008-01-01 00:00:00

  • Application of singular spectrum analysis to the smoothing of raw kinematic signals.

    abstract::Motion capture systems currently used in biomechanical analysis introduce systematic measurement errors that appear in the form of noise in recorded displacement signals. The noise is unacceptably amplified when differentiating displacements to obtain velocities and accelerations. To avoid this phenomenon, it is neces...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.05.031

    authors: Alonso FJ,Castillo JM,Pintado P

    更新日期:2005-05-01 00:00:00

  • Investigation of the kinetics of anaerobic metabolism by analysis of the performance of elite sprinters.

    abstract::The principal motivation for the present work was the study of the kinetics of anaerobic metabolism. A new mathematical model of the bioenergetics of sprinting, incorporating a three-equation representation of anaerobic metabolism, is developed. Results computed using the model are compared with measured data from the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00035-x

    authors: Ward-Smith AJ,Radford PF

    更新日期:2000-08-01 00:00:00

  • Quantitative associations between osteocyte density and biomechanics, microcrack and microstructure in OVX rats vertebral trabeculae.

    abstract::Osteocytes actively regulate bone modeling and remodeling, direct skeletal mineralization, and regulate calcium/phosphate homeostasis and extracellular matrix metabolism; yet the specific role of osteocytes in maintaining bone structural integrity and strength is unknown. Studies have shown that the density of osteocy...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.01.017

    authors: Ma YL,Dai RC,Sheng ZF,Jin Y,Zhang YH,Fang LN,Fan HJ,Liao EY

    更新日期:2008-01-01 00:00:00

  • Shoe midsole hardness, sex and age effects on lower extremity kinematics during running.

    abstract::Previous studies investigating the effects of shoe midsole hardness on running kinematics have often used male subjects from within a narrow age range. It is unknown whether shoe midsole hardness has the same kinematic effect on male and female runners as well as runners from different age categories. As sex and age h...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.03.027

    authors: Nigg BM,Baltich J,Maurer C,Federolf P

    更新日期:2012-06-01 00:00:00

  • Effect of cracks on the local deformations of articular cartilage.

    abstract::Despite significant evidence regarding the increased risk of cartilage degeneration due to traumatic injuries to joints, there is still a lack of understanding of the mechanisms underlying osteoarthritis development following a joint injury. Injuries in knee cartilage are often characterized by lesions or tears. In ad...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109970

    authors: Komeili A,Luqman S,Federico S,Herzog W

    更新日期:2020-09-18 00:00:00

  • A comparison of convergent and bi-plane X-ray photogrammetry systems used to detect total joint loosening.

    abstract::X-ray photogrammetry is an accurate method of measuring structural displacements within the musculoskeletal system. Total joint implant alignment, migration and loosening are important clinical parameters which can be measured by X-ray photogrammetry. The purpose of this paper is to compare two different X-ray photogr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(82)90022-7

    authors: Lippert FG 3rd,Harrington RM,Veress SA,Fraser C,Green D,Bahniuk E

    更新日期:1982-01-01 00:00:00

  • Dynamic stability of individuals with transtibial amputation walking in destabilizing environments.

    abstract::Lower limb amputation substantially disrupts motor and proprioceptive function. People with lower limb amputation experience considerable impairments in walking ability, including increased fall risk. Understanding the biomechanical aspects of the gait of these patients is crucial in improving their gait function and ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.02.033

    authors: Beurskens R,Wilken JM,Dingwell JB

    更新日期:2014-05-07 00:00:00

  • The selection of a standard convention for analyzing gait data based on the analysis of relevant biomechanical factors.

    abstract::The gait cycle is usually analyzed using one of two conventions: heel contact initiates the cycle and stance is followed by swing phases or toe-off initiates the cycle and swing then stance phases are analyzed. The purpose of the study is to demonstrate that based on a consideration of relevant biomechanical measures,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90025-6

    authors: DeVita P

    更新日期:1994-04-01 00:00:00

  • Comparison of blood particle deposition models for non-parallel flow domains.

    abstract::Adhesions of monocytes and platelets to a vascular surface, particularly in regions of flow stagnation, recirculation, and reattachment, are a significant initial event in a broad spectrum of particle-wall interactions that significantly influence the formation of stenotic lesions and mural thrombi. A number of approx...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00434-7

    authors: Worth Longest P,Kleinstreuer C

    更新日期:2003-03-01 00:00:00

  • Does stretching velocity affect residual force enhancement?

    abstract::It is thought that the magnitude of residual force enhancement (RFE) is not affected by stretch velocity. However, the range of stretch velocities studied in previous investigations has been limited to slow and moderate velocities. High velocities of muscle stretching are associated with a loss of force and incomplete...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.04.033

    authors: Fukutani A,Leonard T,Herzog W

    更新日期:2019-05-24 00:00:00

  • The effect of centre of mass location on sagittal plane moments around the centre of mass in trotting horses.

    abstract::The diagonal limb support pattern at trot provides pitch and roll stability, but little is known about the control of moments about the centre of mass (COM) in horses. Correct COM location is critical in the calculation of pitching moments. The objectives were to determine the effect of COM location on pitching moment...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.02.024

    authors: Hobbs SJ,Richards J,Clayton HM

    更新日期:2014-04-11 00:00:00

  • A telemetry-based device to determine the force-displacement behaviour of materials in high impact loading situations.

    abstract::Meaningful testing of stab resistant body armour requires the use of realistic body tissue simulants. A device for the determination of the force-displacement behaviour of materials in high impact loading situations has been developed for the testing of such simulants. Force measurement is achieved with the use of ele...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00191-8

    authors: Chadwick EK,Nicol AC,Floyd S,Gray TG

    更新日期:2000-03-01 00:00:00

  • Concurrent validity and reliability of a mobile tracking technology to measure angular and linear movements of the neck.

    abstract::The neck can be moved in six degrees of freedom. Current 3D-optoelectronic motion-capture systems capable of measuring these movements are inappropriate for use in clinical practice because they are stationary, expensive and time-consuming. We therefore developed a less complex 3D-tracking technology based on Steam®VR...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109340

    authors: Sommer BB,Weisenhorn M,Ernst MJ,Meichtry A,Rast FM,Kleger D,Schmid P,Lünenburger L,Bauer CM

    更新日期:2019-11-11 00:00:00

  • Optimization-based differential kinematic modeling exhibits a velocity-control strategy for dynamic posture determination in seated reaching movements.

    abstract::We proposed a velocity control strategy for dynamic posture determination that underlay an optimization-based differential inverse kinematics (ODIK) approach for modeling three-dimensional (3-D) seated reaching movements. In this modeling approach, a four-segment seven-DOF linkage is employed to represent the torso an...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00117-1

    authors: Zhang X,Kuo AD,Chaffin DB

    更新日期:1998-11-01 00:00:00

  • Assessment of intersegmental coordination of rats during walking at different speeds - Application of continuous relative phase.

    abstract::The present study investigated the feasibility and reliability of continuous relative phase (CRP) and deviation phase (DP) to assess intersegmental hind limb coordination pattern and coordination variability in rats during walking. Twenty-six adult rats walked at 8 m/min, 12 m/min and 16 m/min while two-dimensional ki...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.03.045

    authors: Raffalt PC,Nielsen LR,Madsen S,Højberg LM,Pingel J,Nielsen JB,Alkjær T,Wienecke J

    更新日期:2018-05-17 00:00:00

  • Sex differences in postures of the upper body during a simulated work task performed above shoulder level.

    abstract::The aim of this study was to evaluate if there are sex differences in postures of upper arm, upper back, head and neck after muscle fatigue induced by a simulated work task, requiring upper arm movements performed above shoulder level. Nineteen females and 18 males were evaluated. Upper arm elevation, upper back, head...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109855

    authors: Cid MM,Côté JN,Zancanaro LL,Oliveira AB

    更新日期:2020-06-23 00:00:00

  • Measurement of local diffusion and composition in degraded articular cartilage reveals the unique role of surface structure in controlling macromolecular transport.

    abstract::Developing effective therapeutics for osteoarthritis (OA) necessitates that such molecules can reach and target chondrocytes within articular cartilage. However, predicting how well very large therapeutic molecules diffuse through cartilage is often difficult, and the relationship between local transport mechanics for...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.10.019

    authors: DiDomenico CD,Kaghazchi A,Bonassar LJ

    更新日期:2019-01-03 00:00:00

  • An experimental setup for the measurement of forces on a human cadaveric foot during inversion.

    abstract::An experimental setup was developed for statically measuring seven vertical and three horizontal reaction forces on the foot. In the setup, the leg can be simultaneously loaded (1) by a vertical force, (2) by an externally applied axial moment, and (3) by simulated muscle forces. The foot is free to invert under influ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90080-8

    authors: Ottevanger EJ,Spoor CW,van Leeuwen JL,Sauren AA,Janssen JD,Huson A

    更新日期:1989-01-01 00:00:00

  • Friction in metal-on-metal total disc arthroplasty: effect of ball radius.

    abstract::Total disc arthroplasty (TDA) can be used to replace a degenerated intervertebral disc in the spine. There are different designs of prosthetic discs, but one of the most common is a ball-and-socket combination. Contact between the bearing surfaces can result in high frictional torque, which can then result in wear and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.11.045

    authors: Moghadas P,Mahomed A,Hukins DW,Shepherd DE

    更新日期:2012-02-02 00:00:00

  • Synthesis and characterisation of core-shell structures for orthopaedic surgery.

    abstract::This paperwork deals with the obtaining and characterisation of new acrylic cements for bone surgery. The final mixture of cement contains derivatives of methacryloyloxyethyl phosphate, methacrylic acid or 2-acrylamido-2-methyl-1-propane sulphonic acid. The idea of using these monomers is sustained by their ability to...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.05.002

    authors: Rusen E,Zaharia C,Zecheru T,Mărculescu B,Filmon R,Chappard D,Bădulescu R,Cincu C

    更新日期:2007-01-01 00:00:00

  • Computational analysis of flow structure and particle deposition in a single asthmatic human airway bifurcation.

    abstract::This paper aims to improve current understanding of flow structure and particle deposition in asthmatic human airways. A single, symmetric airway bifurcation, corresponding to generations 10-11 of Weibel's model, is investigated through validated numerical simulations. The parent airway segment is modelled as a smooth...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.05.031

    authors: Zhang H,Papadakis G

    更新日期:2010-09-17 00:00:00

  • Mechanical properties of double-stranded DNA biolayers immobilized on microcantilever under axial compression.

    abstract::In label-free biodetections based on microcantilever technology, double-stranded DNA (dsDNA) structures form through the linkage between probe single-stranded DNA (ssDNA) molecules immobilized on solid substrates and target ssDNA molecules in solutions. Mechanical/electrical properties of these biolayers are important...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.050

    authors: Zhang NH,Chen JZ

    更新日期:2009-07-22 00:00:00

  • Accuracy of a video strain measurement system.

    abstract::The purpose of this study was to determine the accuracy of a video system which our laboratory has been using to measure soft tissue strain. Both static and dynamic error analyses were performed to assess the accuracy of our video system. Static error was defined as the amount of movement reported by the video system ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00131-x

    authors: Smutz WP,Drexler M,Berglund LJ,Growney E,An KN

    更新日期:1996-06-01 00:00:00

  • Pelvic muscle and acetabular contact forces during gait.

    abstract::Locations, magnitudes, and directions of pelvic muscle and acetabular contact forces are important to model the effects of abnormal conditions (e.g., deformity, surgery) of the hip accurately. Such data have not been reported previously. We computed the three-dimensional locations of all pelvic muscle and acetabular c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00041-9

    authors: Pedersen DR,Brand RA,Davy DT

    更新日期:1997-09-01 00:00:00

  • Influences of spherical tip radius, contact depth, and contact area on nanoindentation properties of bone.

    abstract::Nanoindentation has been widely used as a means to measure the micro-mechanical properties of bone and to predict the macroscopic properties. The role of indent depth and indenter tip geometry in measuring the hierarchical properties of bone tissue was explored experimentally using a range of spherical indenter tips o...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.10.008

    authors: Paietta RC,Campbell SE,Ferguson VL

    更新日期:2011-01-11 00:00:00

  • Effects of patella alta and patella infera on patellofemoral contact forces.

    abstract::The relationship between patella alta and patellar subluxation may, in part, reflect the relationship between the height of the patella above the tibiofemoral joint line and the patellofemoral contact force. This study reports on the direct in vitro measurement of the patellofemoral contact force, and its point of app...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90222-4

    authors: Singerman R,Davy DT,Goldberg VM

    更新日期:1994-08-01 00:00:00

  • A probabilistic orthopaedic population model to predict fatigue-related subacromial geometric variability.

    abstract::Fatigue-related glenohumeral and scapulothoracic kinematic relationships, in addition to morphological characteristics of the scapula and humerus, affect the dimensions of the subacromial space. Each exhibits considerable interpersonal variability, which if only considering the mean, can lead to misleading population ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.12.049

    authors: Chopp-Hurley JN,Langenderfer JE,Dickerson CR

    更新日期:2016-02-29 00:00:00

  • Mechanical and metabolic requirements for active lateral stabilization in human walking.

    abstract::Walking appears to be passively unstable in the lateral direction, requiring active feedback control for stability. The central nervous system may control stability by adjusting medio-lateral foot placement, but potentially with a metabolic cost. This cost increases with narrow steps and may affect the preferred step ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.06.002

    authors: Donelan JM,Shipman DW,Kram R,Kuo AD

    更新日期:2004-06-01 00:00:00