Model studies of the flow in abdominal aortic aneurysms during resting and exercise conditions.

Abstract:

:Pulsatile flow in abdominal aortic aneurysm (AAA) models has been examined in order to understand the hemodynamics that may contribute to growth of an AAA. The model studies were conducted by experiments (flow visualization and laser Doppler velocimetry) and by numerical simulation using physiologically realistic resting and exercise flow conditions. We characterize the flow for two AAA model shapes and sizes emulating early AAA development through moderate AAA growth (mean and peak Reynolds numbers of 362 < Re(mean) < 1053 and 3308 < Re(peak) < 5696 with Womersley parameter 16.4 < alpha < 21.2). The results of our investigation indicate that AAA flow can be divided into three flow regimes: (i) Attached flow over the entire cycle in small AAAs at resting conditions, (ii) vortex formation and translation in moderate size AAAs at resting conditions, and (iii) vortex formation, translation and turbulence in moderate size AAAs under exercise conditions. The second two regimes are classified in the medical literature as disturbed flow conditions that have been correlated with atherogenesis as well as thrombogenesis. Thus, AAA disturbed hemodynamics may be a contributing factor to AAA growth by accelerating the degeneration of the arterial wall. Our investigation also concluded that vortex development is considerably weaker in an asymmetric AAA. Furthermore, turbulence was not observed in the asymmetric model. Finally, our investigation suggests a new mode of transition to turbulence: vortex ring instability and bursting to turbulence. The transition process depends on a combination of the pulsatile flow conditions and the tube cross-sectional area change.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Egelhoff CJ,Budwig RS,Elger DF,Khraishi TA,Johansen KH

doi

10.1016/s0021-9290(99)00134-7

keywords:

subject

Has Abstract

pub_date

1999-12-01 00:00:00

pages

1319-29

issue

12

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(99)00134-7

journal_volume

32

pub_type

杂志文章
  • Biofluids, cell mechanics and epigenetics: Flow-induced epigenetic mechanisms of endothelial gene expression.

    abstract::Epigenetics is the regulation of gene expression (transcription) in response to changes in the cell environment through genomic modifications that largely involve the non-coding fraction of the human genome and that cannot be attributed to modification of the primary DNA sequence. Epigenetics is dominant in establishi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.017

    authors: Davies PF,Manduchi E,Jiménez JM,Jiang YZ

    更新日期:2017-01-04 00:00:00

  • Conservation of energy in competitive swimming.

    abstract::Energy conservation in swimming is formulated in terms of four functions of the swim speed v: the consumed power K, the mechanical power P used for horizontal propulsion, the remaining expended mechanical power N, and the thermal power loss H. K is well-known (from VO2) and P = FDv, where the drag force FD is not know...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)00143-r

    authors: Brandt RA,Pichowsky MA

    更新日期:1995-08-01 00:00:00

  • Mechanical interaction of center of pressure and force direction in the upright human.

    abstract::Humans maintain upright bipedal posture by producing appropriate force against the environment through the interaction of neural controlled muscle force with the mechanics of the skeletal system. Characterizing these mechanics facilitates understanding of the neural control. We used a mechanical model of an upright hu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.03.018

    authors: Gruben KG,Boehm WL

    更新日期:2012-06-01 00:00:00

  • The effect of shortening history on isometric and dynamic muscle function.

    abstract::Despite numerous reports on isometric force depression, few reports have quantified force depression during active muscle shortening (dynamic force depression). The purpose of this investigation was to determine the influence of shortening history on isometric force following active shortening, force during isokinetic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.041

    authors: McDaniel J,Elmer SJ,Martin JC

    更新日期:2010-03-03 00:00:00

  • Simultaneous positive and negative external mechanical work in human walking.

    abstract::In human walking, the center of mass motion is similar to an inverted pendulum. Viewing double support as a transition from one inverted pendulum to the next, we hypothesized that the leading leg performs negative work to redirect the center of mass velocity, while simultaneously, the trailing leg performs positive wo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00169-5

    authors: Donelan JM,Kram R,Kuo AD

    更新日期:2002-01-01 00:00:00

  • Nonlinear analysis of gait kinematics to track changes in oxygen consumption in prolonged load carriage walking: a pilot study.

    abstract::Linking human mechanical work to physiological work for the purpose of developing a model of physical fatigue is a complex problem that cannot be solved easily by conventional biomechanical analysis. The purpose of the study was to determine if two nonlinear analysis methods can address the fundamental issue of utiliz...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.06.011

    authors: Schiffman JM,Chelidze D,Adams A,Segala DB,Hasselquist L

    更新日期:2009-09-18 00:00:00

  • Hemodynamic insight into overlapping bare-metal stents strategy in the treatment of aortic aneurysm.

    abstract::Clinical trials have shown overlapping bare-metal stents provoke effective thrombus clot within the aneurysm sac and shrinkage of the aneurysm by directly regulating the hemodynamics. To gain insight into the hemodynamic mechanism of the technique, three cases of simplified thoracic aortic aneurysm models (with no ste...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.03.028

    authors: Zhang P,Liu X,Sun A,Fan Y,Deng X

    更新日期:2015-07-16 00:00:00

  • A myoelectrically based dynamic three-dimensional model to predict loads on lumbar spine tissues during lateral bending.

    abstract::This work describes a dynamic model of the low back that incorporates extensive anatomical detail of the musculo-ligamentous-skeletal system to predict the load time histories of individual tissues. The dynamic reaction moment about L4/L5 was determined during lateral bending from a linked-segment model. This reaction...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90259-4

    authors: McGill SM

    更新日期:1992-04-01 00:00:00

  • The effects of exterior boundary conditions on a internally heated tumor tissue with a thermoporoelastic model.

    abstract::Modeling flow field in tumor regions interstitial space is of primary importance, because of the importance of advection in macromolecule drug delivery. Its deformation has also to be taken into account because of the forces caused by the fluid; if the tumor region is not isothermal, this deformation can be also stron...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110122

    authors: Andreozzi A,Iasiello M,Netti PA

    更新日期:2020-12-02 00:00:00

  • Challenges in relating experimental hip implant fixation predictions to clinical observations.

    abstract::Long-term clinical follow-up studies have shown that radiolucent lines at the cement interfaces of total hip replacement femoral components develop gradually, ultimately leading to loosening. In this experimental study, 32 synthetic femurs implanted with cemented femoral components were cyclically loaded with a dynami...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.10.006

    authors: Sangiorgio SN,Longjohn DB,Dorr LD,Ebramzadeh E

    更新日期:2011-01-11 00:00:00

  • Tribology studies of the natural knee using an animal model in a new whole joint natural knee simulator.

    abstract::The successful development of early-stage cartilage and meniscus repair interventions in the knee requires biomechanical and biotribological understanding of the design of the therapeutic interventions and their tribological function in the natural joint. The aim of this study was to develop and validate a porcine kne...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.07.043

    authors: Liu A,Jennings LM,Ingham E,Fisher J

    更新日期:2015-09-18 00:00:00

  • The behavior of adaptive bone-remodeling simulation models.

    abstract::The process of adaptive bone remodeling can be described mathematically and simulated in a computer model, integrated with the finite element method. In the model discussed here, cortical and trabecular bone are described as continuous materials with variable density. The remodeling rule applied to simulate the remode...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90056-7

    authors: Weinans H,Huiskes R,Grootenboer HJ

    更新日期:1992-12-01 00:00:00

  • Membrane permeability during pressure ulcer formation: A computational model of dynamic competition between cytoskeletal damage and repair.

    abstract::Pressure ulcers are debilitating wounds that arise frequently in people who have lost mobility. Mechanical stress, oxidative stress and ischemia-reperfusion injury are potential sources of damage during pressure ulcer formation, but cross-talk between these sources has rarely been investigated. In vitro experiments wi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.12.022

    authors: Jagannathan NS,Tucker-Kellogg L

    更新日期:2016-05-24 00:00:00

  • Assessment of intersegmental coordination of rats during walking at different speeds - Application of continuous relative phase.

    abstract::The present study investigated the feasibility and reliability of continuous relative phase (CRP) and deviation phase (DP) to assess intersegmental hind limb coordination pattern and coordination variability in rats during walking. Twenty-six adult rats walked at 8 m/min, 12 m/min and 16 m/min while two-dimensional ki...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.03.045

    authors: Raffalt PC,Nielsen LR,Madsen S,Højberg LM,Pingel J,Nielsen JB,Alkjær T,Wienecke J

    更新日期:2018-05-17 00:00:00

  • Validation of a calibration technique for 6-DOF instrumented spatial linkages.

    abstract::This paper presents a practical and effective approach to the calibration of instrumented spatial linkages for biomechanical applications. A 6-DOF mechanical linkage with rotational transducers is designed and in-house manufactured for this purpose. In order to assess the validity of the proposed calibration technique...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.06.021

    authors: Gatti G,Danieli G

    更新日期:2007-01-01 00:00:00

  • Nonuniform swelling-induced residual strains in articular cartilage.

    abstract::Swelling effects in cartilage originate from an interstitial osmotic pressure generated by the presence of negatively charged proteoglycans in the tissue. This swelling pressure gives rise to a non-zero residual strain in the cartilage solid matrix in the absence of externally applied loads. Previous studies have quan...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00184-5

    authors: Narmoneva DA,Wang JY,Setton LA

    更新日期:1999-04-01 00:00:00

  • The fixion proximal femur nailing system: biomechanical properties of the nail and a cadaveric study.

    abstract::The treatment of choice for early mobilization of hip fracture is surgery, which traditionally employs side plates and screws or intramedullary nails. We examined the biomechanical properties of a new proximal femoral nail system. The new expandable Fixion proximal femur nailing (PFN) system, made of stainless-steel a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.03.014

    authors: Steinberg EL,Blumberg N,Dekel S

    更新日期:2005-01-01 00:00:00

  • Lumbar muscle force estimation using a subject-invariant 5-parameter EMG-based model.

    abstract::The use of electromyographic measures, in concert with modeled or empirical representations of muscle physiology, is a common approach for estimation of muscle force. Existing models of the lumbar musculature have allowed model parameters to vary for an individual subject. While this approach improves apparent predict...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00055-4

    authors: Nussbaum MA,Chaffin DB

    更新日期:1998-07-01 00:00:00

  • Feasibility of noninvasive evaluation of biophysical properties of tissue-engineered cartilage by using quantitative MRI.

    abstract::The application of tissue-engineered cartilage in a clinical setting requires a noninvasive method to assess the biophysical and biochemical properties of the engineered cartilage. Since articular cartilage is composed of 70-80% water and has dense extracellular matrixes (ECM), it is considered that the condition of t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.02.002

    authors: Miyata S,Numano T,Homma K,Tateishi T,Ushida T

    更新日期:2007-01-01 00:00:00

  • Morphing methods to parameterize specimen-specific finite element model geometries.

    abstract::Shape plays an important role in determining the biomechanical response of a structure. Specimen-specific finite element (FE) models have been developed to capture the details of the shape of biological structures and predict their biomechanics. Shape, however, can vary considerably across individuals or change due to...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.08.036

    authors: Sigal IA,Yang H,Roberts MD,Downs JC

    更新日期:2010-01-19 00:00:00

  • The sensitivity of cartilage contact pressures in the knee joint to the size and shape of an anatomically shaped meniscal implant.

    abstract::Since meniscal geometry affects the cartilage contact pressures, it is essential to carefully define the geometry of the synthetic meniscal implant that we developed. Recently, six independent modes of size- and shape-related geometry variation were identified through 3D statistical shape modeling (SSM) of the medial ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.034

    authors: Khoshgoftar M,Vrancken AC,van Tienen TG,Buma P,Janssen D,Verdonschot N

    更新日期:2015-06-01 00:00:00

  • Increased hip adduction during running is associated with patellofemoral pain and differs between males and females: A case-control study.

    abstract::Patellofemoral pain is common amongst recreational runners and associated with altered running kinematics. However, it is currently unclear how sex may influence kinematic differences previously reported in runners with patellofemoral pain. This case-control study aimed to evaluate lower limb kinematics in males and f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.05.014

    authors: Neal BS,Barton CJ,Birn-Jeffery A,Morrissey D

    更新日期:2019-06-25 00:00:00

  • Identification of key events in baseball hitting using inertial measurement units.

    abstract::Quantification of baseball hitting mechanics under game conditions help players to become successful batters and prevent injuries. Inertial measurement units (IMUs) can measure motion without any spatial restriction and are thus becoming a popular tool to investigate sports biomechanics. Biomechanical analysis of hitt...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.02.001

    authors: Punchihewa NG,Yamako G,Fukao Y,Chosa E

    更新日期:2019-04-18 00:00:00

  • Fluid pressures at the shoe-floor-contaminant interface during slips: effects of tread and implications on slip severity.

    abstract::Previous research on slip and fall accidents has suggested that pressurized fluid between the shoe and floor is responsible for initiating slips yet this effect has not been verified experimentally. This study aimed to (1) measure hydrodynamic pressures during slipping for treaded and untreaded conditions; (2) determi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.jbiomech.2013.10.046

    authors: Beschorner KE,Albert DL,Chambers AJ,Redfern MS

    更新日期:2014-01-22 00:00:00

  • Kinetic analysis of the center of gravity of the human body in normal and pathological gaits.

    abstract::The kinetics of the body's center of gravity during level walking were analyzed in 50 normal subjects and 47 patients. The three-dimensional displacements of the center of gravity were computed by the integration of force plate data. The energy levels and the power requirements of the center of gravity were also calcu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90328-9

    authors: Iida H,Yamamuro T

    更新日期:1987-01-01 00:00:00

  • Novel compact device for clinically measuring extraocular muscle (EOM) tension.

    abstract::Accurate knowledge of extraocular muscle (EOM) tension is important for the diagnosis of and surgical planning for strabismus, such as choosing which eye to operate or determining the amount of muscle displacement. Previous evaluations of passive EOM tension have relied extensively on the experience and skill of ophth...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109955

    authors: Shin HJ,Lee SJ,Oh CS,Kang H

    更新日期:2020-08-26 00:00:00

  • Estimation of finger muscle tendon tensions and pulley forces during specific sport-climbing grip techniques.

    abstract::The present work displayed the first quantitative data of forces acting on tendons and pulleys during specific sport-climbing grip techniques. A three-dimensional static biomechanical model was used to estimate finger muscle tendon and pulley forces during the "slope" and the "crimp" grip. In the slope grip the finger...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.08.027

    authors: Vigouroux L,Quaine F,Labarre-Vila A,Moutet F

    更新日期:2006-01-01 00:00:00

  • Bone creep and short and long term subsidence after cemented stem total hip arthroplasty (THA).

    abstract::Stem-cement and cement-bone interfacial failures as well as cement fractures have been noted in cemented total hip arthroplasty (THA) as the cause of aseptic loosening. Attempts to reduce the risk of femoral component loosening include improving the stem-cement interface by various coatings, using a textured or porous...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.12.010

    authors: Norman TL,Shultz T,Noble G,Gruen TA,Blaha JD

    更新日期:2013-03-15 00:00:00

  • Effect of scaffold material, construct length and mechanical stimulation on the in vitro stiffness of the engineered tendon construct.

    abstract::Introducing mesenchymal stem cell (MSC)-seeded collagen constructs into load-protected wound sites in the rabbit patellar and Achilles tendons significantly improves their repair outcome compared to natural healing of the unfilled defect. However, these constructs would not be acceptable alternatives for repairing com...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.11.009

    authors: Nirmalanandhan VS,Rao M,Shearn JT,Juncosa-Melvin N,Gooch C,Butler DL

    更新日期:2008-01-01 00:00:00

  • Pure moment testing for spinal biomechanics applications: Fixed versus sliding ring cable-driven test designs.

    abstract::In vitro multi-axial bending testing using pure moment loading conditions has become the standard in evaluating the effects of different types of surgical intervention on spinal kinematics. Simple, cable-driven experimental set-ups have been widely adopted because they require little infrastructure. Traditionally, "fi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.02.004

    authors: Eguizabal J,Tufaga M,Scheer JK,Ames C,Lotz JC,Buckley JM

    更新日期:2010-05-07 00:00:00