Numerical errors and uncertainties in finite-element modeling of trabecular bone.

Abstract:

:Although micromechanical finite-element models are being increasingly used to help interpret the results of bio-mechanical tests, there has not yet been a systematic study of the numerical errors and uncertainties that occur with these methods. In this work, finite-element models of human L1 vertebra have been used to analyze the sensitivity of the calculated elastic moduli to resolution, boundary conditions, and variations in the Poisson's ratio of the tissue material. Our results indicate that discretization of the bone architecture, inherent in the tomography process, leads to an underestimate in the calculated elastic moduli of about 20% at 20 microm resolution; these errors vary roughly linearly with the size of the image voxels. However, it turns out that there is a cancellation of errors between the softening introduced by the discretization of the bone architecture and the excess bending resistance of eight-node hexahedral finite elements. Our empirical finding is that eight-node cubic elements of the same size as the image voxels lead to the most accurate calculation for a given number of elements, with errors of less than 5% at 20 microm resolution. Comparisons with mechanical testing are also hindered by uncertainties in the grip conditions: our results show that these uncertainties are of comparable magnitude to the systematic differences in mechanical testing methods. Both discretization errors and uncertainties in grip conditions have a smaller effect on relative moduli, used when comparing between different specimens or different load directions, than on an absolute modulus. The effects of variations in the Poisson's ratio of the bone tissue were found to be negligible.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Ladd AJ,Kinney JH

doi

10.1016/s0021-9290(98)00108-0

subject

Has Abstract

pub_date

1998-10-01 00:00:00

pages

941-5

issue

10

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(98)00108-0

journal_volume

31

pub_type

杂志文章
  • Load transfer across the pelvic bone.

    abstract::Earlier experimental and finite element studies notwithstanding, the load transfer and stress distribution in the pelvic bone and the acetabulum in normal conditions are not well understood. This hampers the development of orthopaedic reconstruction methods. The present study deals with more precise finite element ana...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)00125-n

    authors: Dalstra M,Huiskes R

    更新日期:1995-06-01 00:00:00

  • A computer-controlled mechanical culture system for biological testing of articular cartilage explants.

    abstract::A computer-controlled mechanical culture system was designed to investigate the interaction between mechanical stimuli and the metabolism of articular cartilage. The main features of this system include the following capabilities: (1) Accurately controlled static, permanent cyclic or intermittent cyclic mechanical loa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00040-7

    authors: Steinmeyer J

    更新日期:1997-08-01 00:00:00

  • Modification of spastic gait through mechanical damping.

    abstract::The effect of dissipative mechanical loads on spastic gait has been studied, to evaluate the feasibility of using mechanically damped orthoses to effect functional improvements in the gait of spastic patients. This concept is based on a hypothesis citing uninhibited, velocity-dependent stretch reflexes as a possible c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(85)90278-7

    authors: Maki BE,Rosen MJ,Simon SR

    更新日期:1985-01-01 00:00:00

  • Stance and swing phase detection during level and slope walking in the cat: effects of slope, injury, subject and kinematic detection method.

    abstract::In quadrupeds, there have been limited comparisons of gait timing events detection (e.g., paw contact, PC and paw-off, PO) determined from kinematics and forceplates. The goal of this study was to investigate the effect of different slopes (0, -27, +27°), recovery times after ankle extensor nerve injury and repair (2,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.03.013

    authors: Pantall A,Gregor RJ,Prilutsky BI

    更新日期:2012-05-11 00:00:00

  • Loading-induced changes on topographical distributions of the zonal properties of osteoarthritic tibial cartilage--A study by magnetic resonance imaging at microscopic resolution.

    abstract::The topographical distributions of the zonal properties of articular cartilage over the medial tibia from an experimental osteoarthritis (OA) model were evaluated as a function of external loading by microscopic Magnetic Resonance Imaging (µMRI). T2 relaxation times and cartilage thicknesses were measured at 17.6 µm r...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.08.011

    authors: Lee JH,Badar F,Kahn D,Matyas J,Qu X,Xia Y

    更新日期:2015-10-15 00:00:00

  • A kinematic algorithm to identify gait events during running at different speeds and with different footstrike types.

    abstract::Although a number of algorithms exist for estimating ground contact events (GCEs) from kinematic data during running, they are typically only applicable to heelstrike running, or have only been evaluated at a single running speed. The purpose of this study was to investigate the accuracy of four kinematics-based algor...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.10.013

    authors: Handsaker JC,Forrester SE,Folland JP,Black MI,Allen SJ

    更新日期:2016-12-08 00:00:00

  • Comparison of the vulnerability risk for positive versus negative atheroma plaque morphology.

    abstract::As plaque develops in arteries two types of remodeling can occur; positive and negative remodeling. Positive remodeling is an outward compensatory remodeling in which the arterial wall grows outward in an attempt to maintain a constant lumen diameter, while negative remodeling is defined as a local shrinkage of vessel...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.02.012

    authors: Cilla M,Peña E,Martínez MA,Kelly DJ

    更新日期:2013-04-26 00:00:00

  • Biomedical microfluidic devices by using low-cost fabrication techniques: A review.

    abstract::One of the most popular methods to fabricate biomedical microfluidic devices is by using a soft-lithography technique. However, the fabrication of the moulds to produce microfluidic devices, such as SU-8 moulds, usually requires a cleanroom environment that can be quite costly. Therefore, many efforts have been made t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2015.11.031

    authors: Faustino V,Catarino SO,Lima R,Minas G

    更新日期:2016-07-26 00:00:00

  • Identification of intrinsic and reflexive contributions to low-back stiffness: medium-term reliability and construct validity.

    abstract::This study aimed at testing the reliability and construct validity of a trunk perturbation protocol (TPP) that estimates the intrinsic and reflexive contributions to low-back stiffness. The TPP consists of a series of pseudorandom position-controlled trunk perturbations in an apparatus measuring forces and displacemen...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.11.036

    authors: Larivière C,Ludvig D,Kearney R,Mecheri H,Caron JM,Preuss R

    更新日期:2015-01-21 00:00:00

  • Comparison of different state space definitions for local dynamic stability analyses.

    abstract::Measures of local dynamic stability, such as the local divergence exponent (lambda*(s)) quantify how quickly small perturbations deviate from an attractor that defines the motion. When the governing equations of motion are unknown, an attractor can be reconstructed by defining an appropriate state space. However, stat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.015

    authors: Gates DH,Dingwell JB

    更新日期:2009-06-19 00:00:00

  • A new technique to study the mechanical properties of collagen lattices.

    abstract::A new technique to study the mechanical properties of collagen lattices or dermal equivalents is described. With the help of the load-extension curve obtained with a uniaxial traction apparatus, a stiffness modulus varying from 0.06 to 1 MPa is calculated from the studied parameters (duration of culture, collagen and ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90250-5

    authors: Chapuis JF,Agache P

    更新日期:1992-01-01 00:00:00

  • Artery buckling analysis using a four-fiber wall model.

    abstract::Artery bent buckling has been suggested as a possible mechanism that leads to artery tortuosity, which is associated with aging, hypertension, atherosclerosis, and other pathological conditions. It is necessary to understand the relationship between microscopic wall structural changes and macroscopic artery buckling b...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.06.005

    authors: Liu Q,Wen Q,Mottahedi M,Han HC

    更新日期:2014-08-22 00:00:00

  • Modelling the mechanical effect of muscles with large attachment sites: application to the shoulder mechanism.

    abstract::A general theory is described for deriving the mechanical effect of muscles with large attachment sites. In a cadaver experiment the complete attachment sites and bundle distribution of 16 muscles of the shoulder mechanism were recorded. These data were used to calculate the mechanical effect, i.e. the resulting force...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90007-a

    authors: Van der Helm FC,Veenbaas R

    更新日期:1991-01-01 00:00:00

  • Assessment of intersegmental coordination of rats during walking at different speeds - Application of continuous relative phase.

    abstract::The present study investigated the feasibility and reliability of continuous relative phase (CRP) and deviation phase (DP) to assess intersegmental hind limb coordination pattern and coordination variability in rats during walking. Twenty-six adult rats walked at 8 m/min, 12 m/min and 16 m/min while two-dimensional ki...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.03.045

    authors: Raffalt PC,Nielsen LR,Madsen S,Højberg LM,Pingel J,Nielsen JB,Alkjær T,Wienecke J

    更新日期:2018-05-17 00:00:00

  • Comparison of muscle forces and joint load from an optimization and EMG assisted lumbar spine model: towards development of a hybrid approach.

    abstract::The purpose of this study was to determine whether the same estimates of individual muscle and L4/L5 lumbar joint compressive forces result from an optimization (OPT) compared to an electromyography (EMG) assisted approach for solving the inderminate moment equilibrium equations in the same anatomical model. Four male...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)00065-c

    authors: Cholewicki J,McGill SM,Norman RW

    更新日期:1995-03-01 00:00:00

  • Evaluation of human nasal cartilage nonlinear and rate dependent mechanical properties.

    abstract::Nasal reconstruction frequently requires donor cartilage and tissue, and ideally, donor tissue will closely emulate native nasal cartilage mechanics. Tissue engineering scaffolds, especially 3D printed scaffolds, have been proposed for nasal reconstruction, and the success of these constructs may depend on how well sc...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109549

    authors: Chang B,Reighard C,Flanagan C,Hollister S,Zopf D

    更新日期:2020-02-13 00:00:00

  • Effects of walking speed, strength and range of motion on gait stability in healthy older adults.

    abstract::Falls pose a tremendous risk to those over 65 and most falls occur during locomotion. Older adults commonly walk slower, which many believe helps improve walking stability. While increased gait variability predicts future fall risk, increased variability is also caused by walking slower. Thus, we need to better unders...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.08.002

    authors: Kang HG,Dingwell JB

    更新日期:2008-10-20 00:00:00

  • How muscle architecture and moment arms affect wrist flexion-extension moments.

    abstract::The purpose of this investigation was to determine how the moment arms and architecture of the wrist muscles influence their isometric moment-generating characteristics. A three-dimensional computer graphic model was developed that estimates the moment arms, maximum isometric forces, and maximum isometric flexion-exte...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00015-8

    authors: Gonzalez RV,Buchanan TS,Delp SL

    更新日期:1997-07-01 00:00:00

  • Establishing reference values for cervical spine range of motion in pre-pubescent children.

    abstract::Medical professionals, physical therapists, product designers, and computational models all use cervical spine range of motion reference values. To support these functions, researchers have collected a plethora of data to determine the normal range of motion of the cervical spine of adult subjects. However, little to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.06.021

    authors: Lynch-Caris T,Majeske KD,Brelin-Fornari J,Nashi S

    更新日期:2008-08-28 00:00:00

  • Comparison of tendon tensions estimated from two biomechanical models of the thumb.

    abstract::Despite the paramount function of the thumb in daily life, thumb biomechanical models have been little developed and studied. Moreover, only two studies provided quantitative anthropometric data of tendon moment arms. To investigate thumb tendon tensions, biomechanicians and clinicians have to know the performances an...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.052

    authors: Vigouroux L,Domalain M,Berton E

    更新日期:2009-08-07 00:00:00

  • Synthesis and characterisation of core-shell structures for orthopaedic surgery.

    abstract::This paperwork deals with the obtaining and characterisation of new acrylic cements for bone surgery. The final mixture of cement contains derivatives of methacryloyloxyethyl phosphate, methacrylic acid or 2-acrylamido-2-methyl-1-propane sulphonic acid. The idea of using these monomers is sustained by their ability to...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.05.002

    authors: Rusen E,Zaharia C,Zecheru T,Mărculescu B,Filmon R,Chappard D,Bădulescu R,Cincu C

    更新日期:2007-01-01 00:00:00

  • In vitro analysis of a model of intracardiac jet: analysis of the central core of axisymmetric jets.

    abstract::In order to provide physical information supporting the clinical use of flow mapping, an in vitro model was designed to measure the velocity fields in a pulsatile hydraulic turbulent jet. We used a peak velocity ranging from 2.5 to 5.5 m.s-1, an orifice diameter ranging from 5.8 to 11.3 mm and confined the jet in a re...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90367-c

    authors: Diebold B,Delouche A,Dumée P,Guglielmi JP,Delouche P,Péronneau P

    更新日期:1990-01-01 00:00:00

  • A new in vivo technique for determination of 3D kinematics and contact areas of the patello-femoral and tibio-femoral joint.

    abstract::Patello-femoral disorders are often caused by changes of patello-femoral and/or tibio-femoral kinematics. However, until now there has been no quantitative in vivo technique, that is able to obtain 3D kinematics and contact areas of all knee compartments simultaneously on a non-invasive basis. The aim of this study wa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.09.034

    authors: von Eisenhart-Rothe R,Siebert M,Bringmann C,Vogl T,Englmeier KH,Graichen H

    更新日期:2004-06-01 00:00:00

  • A mechanical model for the human intervertebral disc.

    abstract::Stress relaxation experiments were performed on specimens from a human intervertebral disc. Specimens were made from the nucleus pulposus and from the external lamellae of the anulus fibrosus in two different orientations. Tests were run with varying moisture content so as to develop a relaxation master curve. A model...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90144-8

    authors: Panagiotacopulos ND,Pope MH,Krag MH,Bloch R

    更新日期:1987-01-01 00:00:00

  • An explicit expression for the moment in multibody systems.

    abstract::The equations of motion are formulated for a set of interacting rigid bodies. An explicit formulation could be derived for the total moment of the forces on such a system. This is applied to (1) the intersegmental moment in a multisegment rigid-body model, and (2) the interpretation of the 'centre of pressure' as defi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90076-d

    authors: Hof AL

    更新日期:1992-10-01 00:00:00

  • Leaflet stress and strain distributions following incomplete transcatheter aortic valve expansion.

    abstract::Transcatheter aortic valve replacement (TAVR) is an established treatment alternative to surgical valve replacement in high-risk patients with severe symptomatic aortic stenosis. The current guidelines for TAVR are to upsize transcatheter aortic valve (TAV) relative to the native annulus to secure the device and minim...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.08.012

    authors: Abbasi M,Azadani AN

    更新日期:2015-10-15 00:00:00

  • Computational assessment of the effects of the catheter type on particle-hemodynamics during liver radioembolization.

    abstract::Radioembolization, which consist of the implantation of radioactive microspheres via intra-arterially placed microcatheter, is a safe and effective treatment for liver cancer. Nevertheless, radioembolization-related complications and side effects may arise, which are an active area of ongoing research. The catheter de...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.09.035

    authors: Aramburu J,Antón R,Rivas A,Ramos JC,Sangro B,Bilbao JI

    更新日期:2016-11-07 00:00:00

  • Effects of follower load and rib cage on intervertebral disc pressure and sagittal plane curvature in static tests of cadaveric thoracic spines.

    abstract::The clinical relevance of mechanical testing studies of cadaveric human thoracic spines could be enhanced by using follower preload techniques, by including the intact rib cage, and by measuring thoracic intervertebral disc pressures, but studies to date have not incorporated all of these components simultaneously. Th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.02.038

    authors: Anderson DE,Mannen EM,Sis HL,Wong BM,Cadel ES,Friis EA,Bouxsein ML

    更新日期:2016-05-03 00:00:00

  • A laser-aligned method for anthropometry of hands.

    abstract::We have developed a laser-aligned measuring device to facilitate the measurement of linear hand dimensions. Our objective has been to make a simple, clinically applicable device for anthropometry of the hands in patients with arthritis in order to gauge the progression of hand deformities. The system provides an alter...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00121-0

    authors: Highton J,Davidson P,Markham V

    更新日期:2003-09-01 00:00:00

  • Impact-induced osteochondral fracture in the tibial plateau.

    abstract::In this study, human tibia plateaus with the meniscus removed were impacted on various regions of the plateau surface via a drop test using a 5mm indenter. Osteochondral blocks containing the failure site were then extracted, chemically fixed, dehydrated, gold-particle coated, and sent for X-ray micro-CT imaging to ob...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.01.033

    authors: Thambyah A,Shim VP,Chong LM,Lee VS

    更新日期:2008-01-01 00:00:00