Abstract:
:The three-dimensional trajectory of the body's centre of mass (COM) is useful to determine a number of biomechanical outcomes in running research. Previous studies have used the COM to calculate measures such as overstriding, vertical stiffness, and vertical oscillation. The COM is traditionally computed using the segmental analysis method, though this is expensive and time-consuming owing to the need for a full-body marker set. The purpose of this study was to determine whether the COM trajectory can be approximated by a single sacral marker during running. Seventy-one participants underwent a biomechanical running analysis on a treadmill utilizing a full-body marker set. Marker trajectories from the sacral marker and from the COM calculated using the segmental analysis method were compared over the entire gait cycle by computing intraclass correlation coefficient (ICC) and root-mean-square error. Paired t-tests were used to determine if the positions differed in mediolateral, anteroposterior, and vertical directions at three gait events (initial contact, midstance, and toe-off). The trajectories from the two methods exhibited a similar pattern in vertical and anteroposterior directions throughout the gait cycle, displaying strong correlations in these directions (ICC = 0.98 ± 0.01 and 0.83 ± 0.07). Our results suggest that a single sacral marker is a valid proxy for COM trajectory in vertical and anteroposterior directions at key events during the stance phase of running in a female recreational population. Researchers can therefore use a single sacral marker to estimate COM trajectory, rather than a full-body marker set, saving on both time and supplies.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Napier C,Jiang X,MacLean CL,Menon C,Hunt MAdoi
10.1016/j.jbiomech.2020.109886subject
Has Abstractpub_date
2020-07-17 00:00:00pages
109886eissn
0021-9290issn
1873-2380pii
S0021-9290(20)30309-2journal_volume
108pub_type
杂志文章abstract::As 3-dimensional (3D) motion-capture for clinical gait analysis continues to evolve, new methods must be developed to improve the detection of gait cycle events based on kinematic data. Recently, the application of principal component analysis (PCA) to gait data has shown promise in detecting important biomechanical f...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.06.009
更新日期:2014-08-22 00:00:00
abstract::The purpose of this study was to determine which factor is the most likely one to have stimulated the mineralization process in the in vitro experiments of Klein-Nulend et al. (Arth. Rheum., 29, 1002-1009, 1986), in which fetal cartilaginous metatarsals were externally loaded with an intermittent hydrostatic pressure,...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(98)00165-1
更新日期:1999-02-01 00:00:00
abstract::In this paper, we apply the micropipette to reduce the surface area of the rabbit aorta, and the relationship between the fractional area change of the aortic surface and the negative pressure in the pipette is studied. The experimental results for seven rabbit thoracic aortas show that the relationship can be express...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(96)00003-6
更新日期:1996-08-01 00:00:00
abstract::Flatfoot is a risk factor for patellofemoral pain syndrome (PFPS), and excessive rearfoot eversion occurring in flatfoot has been associated with the development and progression of PFPS; however, the mechanism remains unclear. This study aimed to investigate transverse shank and frontal rearfoot coordination patterns ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.110119
更新日期:2021-01-22 00:00:00
abstract::The finite element method described in this study provides an easy method to simulate the kinetics of multibody mechanisms. It is used in order to develop a musculoskeletal model of the shoulder mechanism. Each relevant morphological structure has been represented by an appropriate element. For the shoulder mechanism ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(94)90065-5
更新日期:1994-05-01 00:00:00
abstract::We present a comparison of the flow characteristics in an idealized smooth trachea model and a second model which has a roughness simulating cartilaginous rings. We use refractive index-matched particle image velocimetry (PIV) to measure the velocity field in a two-generation model of the trachea and main bronchi. The...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.03.043
更新日期:2016-06-14 00:00:00
abstract::Spinal intervertebral joints are complex structures allowing motion in multiple directions, and many experimental studies have reported moment-rotation response. However, experimental methods, reporting of results, and levels of the spine tested vary widely, and a comprehensive assessment of moment-rotation response a...
journal_title:Journal of biomechanics
pub_type: 杂志文章,meta分析,评审
doi:10.1016/j.jbiomech.2019.109579
更新日期:2020-02-13 00:00:00
abstract::Bone strains resulting from physical activity are thought to be a primary driver of bone adaptation, but cannot be directly noninvasively measured. Because bone adapts nonuniformly, physical activity may make an important independent structural contribution to bone strength that is independent of bone mass and density...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.04.050
更新日期:2014-08-22 00:00:00
abstract::The purpose of this study was to investigate the mechanical consequences of proteoglycan 4 (Prg4) deficiency on intervertebral disc mechanics using a Prg4 knockout mouse model. Prg4, also called lubricin, was first identified as the boundary lubricant in synovial fluid but has subsequently been localized within a numb...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.03.029
更新日期:2015-07-16 00:00:00
abstract::Despite the paramount function of the thumb in daily life, thumb biomechanical models have been little developed and studied. Moreover, only two studies provided quantitative anthropometric data of tendon moment arms. To investigate thumb tendon tensions, biomechanicians and clinicians have to know the performances an...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.03.052
更新日期:2009-08-07 00:00:00
abstract::In human walking, the center of mass motion is similar to an inverted pendulum. Viewing double support as a transition from one inverted pendulum to the next, we hypothesized that the leading leg performs negative work to redirect the center of mass velocity, while simultaneously, the trailing leg performs positive wo...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(01)00169-5
更新日期:2002-01-01 00:00:00
abstract::As a first step towards developing a dynamic model of the rat hindlimb, we measured muscle attachment and joint center coordinates relative to bony landmarks using stereophotogrammetry. Using these measurements, we analyzed muscle moment arms as functions of joint angle for most hindlimb muscles, and tested the hypoth...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.10.004
更新日期:2008-01-01 00:00:00
abstract::A clinical strength MRI and intact bovine caudal intervertebral discs were used to test the hypotheses that (1) mechanical loading and trypsin treatment induce changes in NMR parameters, mechanical properties and biochemical contents; and (2) mechanical properties are quantitatively related to NMR parameters. MRI acqu...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.04.015
更新日期:2006-01-01 00:00:00
abstract::Vessel geometry for numerical analysis is generally obtained by computed tomography (CT) or magnetic resonance imaging (MRI) and intravascular ultrasound (IVUS). Most medical imaging is obtained from patients for hemodynamic analysis due to the properties of vascular disease and the difficulties in angiography. To pre...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2012.04.003
更新日期:2012-06-01 00:00:00
abstract::The purpose of this study was to analyze the reproducibility of kinematic, dynamometric and derived mechanical energy parameters in the pole vault as a main precondition for the practical applicability of the concept of energy exchange in the pole vault. A total of 46 vaults of six experienced vaulters were analyzed. ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.03.027
更新日期:2006-01-01 00:00:00
abstract::Bending and compressive loads were applied intermittently at 0.5 Hz through implants chronically inserted into the radius and ulna of experimental sheep. The plane of bending was the same as that imposed during locomotion. The principal variables of the artificial strain regime were the peak strains and strain rates, ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(82)90092-6
更新日期:1982-01-01 00:00:00
abstract::Cervical spine injuries continue to be a costly societal problem. Future advancements in injury prevention depend on improved physical and computational models, which are predicated on a better understanding of the neck response during dynamic loading. Previous studies have shown that the tolerance of the neck is depe...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.01.006
更新日期:2016-02-29 00:00:00
abstract::A device is described for measuring strength and power outputs of dynamic vertical lifts between heights of 0.4 and 2.2 m. The device is safe, robust, and easily transportable. It consists of a water-filled tube 2 m high and 200 mm internal diameter. The subject pulls vertically on a handle which is connected with fle...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(96)00155-8
更新日期:1997-04-01 00:00:00
abstract::The three-dimensional geometry of the human spine is noteworthy information that can be obtained by stereoradiographic methods. These methods are based on the identification of anatomical structures in several views which are obtained by rotation of a patient standing on a turntable. Calibration algorithms for compute...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(03)00016-2
更新日期:2003-06-01 00:00:00
abstract::The mechanism of vertebral wedge fractures remains unclear and may relate to typical variations in the mechanical behavior of the intervertebral disc. To gain insight, we tested 16 individual whole discs (between levels T8 and L5) from nine cadavers (mean±SD: 66±16 years), loaded in compression at different rates (0.0...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.02.045
更新日期:2016-05-03 00:00:00
abstract::The use of finite element (FE) methods in spinal research is increasing, but there is only limited information available on the influence of different input parameters on the model predictions. The aim of this study was to investigate the role of these parameters in FE models of the vertebral body. Experimental tests ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2006.02.005
更新日期:2007-01-01 00:00:00
abstract::This study aimed to compare the muscle activities of the lower limb during overground level running (LR) and uphill running (UR) by using a musculoskeletal model. Six male distance runners ran at three running speeds (slow: 3.3 m/s; medium: 4.2 m/s; and high: 5.0 m/s) on a level runway and a slope of 9.1% grade in whi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.05.028
更新日期:2007-01-01 00:00:00
abstract::Uncrimping of collagen fibers in the arterial wall is an integral process in regulating the macro-level mechanical response of arteries. Uncrimping of collagen fibers leads to a gradual, but significant strain-stiffening response of the artery at physiological pressures and prevents overdistention at elevated pressure...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.08.001
更新日期:2013-10-18 00:00:00
abstract:PURPOSE:The accuracy of biomechanical models is predicated on the realism by which they represent their biomechanical tissues. Unfortunately, most models use phenomenological ligament models that neglect the behaviour in the failure region. Therefore, the purpose of this investigation was to test whether a mechanistic ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.06.039
更新日期:2017-08-16 00:00:00
abstract::Subchondral bone microdamage due to high-impact loading is a key factor leading to post-traumatic knee osteoarthritis. A quantified assessment of the mechanical characteristics of subchondral bone at the tissue-level is essential to study the mechanism of impact-induced microdamage. We combined mechanical impact testi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.05.016
更新日期:2016-07-05 00:00:00
abstract::The forces and moments acting at the hip joint influence the long-term stability of the fixation of endoprostheses and the course of coxarthrosis. These loads may depend on the kind of footwear and the walking or running style. These factors were investigated in a patient with instrumented hip implants. He wore differ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(94)00129-r
更新日期:1995-07-01 00:00:00
abstract::A new transducer was developed for in situ measurement of the force vector in a complex muscle. The transducer measures the magnitude, and the line of action of a force in a single plane. The dynamic range of the transducer is 0-5 N. This range includes the small forces developed by an active motor unit and the relati...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(96)84545-3
更新日期:1996-11-01 00:00:00
abstract::In this study, a theoretical framework for simulation of fracture of bone and bone-like materials is provided. An expanded cohesive zone model with thermodynamically consistent framework has been proposed and used to investigate the crack growth resistance of bone and bone-like materials. The reversible elastic deform...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.04.054
更新日期:2014-07-18 00:00:00
abstract::We investigated the microstructural basis of a reduced stress concentration around the primary nutrient foramen of the equine third metacarpus. We quantified the spatial variations of compositional parameters (mineral content, volume fraction, histological architecture, and osteonal trajectories) from microradiographs...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(03)00130-1
更新日期:2003-10-01 00:00:00
abstract::Relatively high rates of loosening and implant failure have been reported after total ankle arthroplasty. Abnormal kinematics and incongruency of the articular surface may cause increased contact pressure and rotational torque applied to the implant, leading to loosening and implant failure. We measured in vivo kinema...
journal_title:Journal of biomechanics
pub_type: 临床试验,杂志文章
doi:10.1016/j.jbiomech.2012.05.043
更新日期:2012-08-09 00:00:00