The use of a single sacral marker method to approximate the centre of mass trajectory during treadmill running.

Abstract:

:The three-dimensional trajectory of the body's centre of mass (COM) is useful to determine a number of biomechanical outcomes in running research. Previous studies have used the COM to calculate measures such as overstriding, vertical stiffness, and vertical oscillation. The COM is traditionally computed using the segmental analysis method, though this is expensive and time-consuming owing to the need for a full-body marker set. The purpose of this study was to determine whether the COM trajectory can be approximated by a single sacral marker during running. Seventy-one participants underwent a biomechanical running analysis on a treadmill utilizing a full-body marker set. Marker trajectories from the sacral marker and from the COM calculated using the segmental analysis method were compared over the entire gait cycle by computing intraclass correlation coefficient (ICC) and root-mean-square error. Paired t-tests were used to determine if the positions differed in mediolateral, anteroposterior, and vertical directions at three gait events (initial contact, midstance, and toe-off). The trajectories from the two methods exhibited a similar pattern in vertical and anteroposterior directions throughout the gait cycle, displaying strong correlations in these directions (ICC = 0.98 ± 0.01 and 0.83 ± 0.07). Our results suggest that a single sacral marker is a valid proxy for COM trajectory in vertical and anteroposterior directions at key events during the stance phase of running in a female recreational population. Researchers can therefore use a single sacral marker to estimate COM trajectory, rather than a full-body marker set, saving on both time and supplies.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Napier C,Jiang X,MacLean CL,Menon C,Hunt MA

doi

10.1016/j.jbiomech.2020.109886

subject

Has Abstract

pub_date

2020-07-17 00:00:00

pages

109886

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(20)30309-2

journal_volume

108

pub_type

杂志文章
  • Predicting timing of foot strike during running, independent of striking technique, using principal component analysis of joint angles.

    abstract::As 3-dimensional (3D) motion-capture for clinical gait analysis continues to evolve, new methods must be developed to improve the detection of gait cycle events based on kinematic data. Recently, the application of principal component analysis (PCA) to gait data has shown promise in detecting important biomechanical f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.06.009

    authors: Osis ST,Hettinga BA,Leitch J,Ferber R

    更新日期:2014-08-22 00:00:00

  • Why does intermittent hydrostatic pressure enhance the mineralization process in fetal cartilage?

    abstract::The purpose of this study was to determine which factor is the most likely one to have stimulated the mineralization process in the in vitro experiments of Klein-Nulend et al. (Arth. Rheum., 29, 1002-1009, 1986), in which fetal cartilaginous metatarsals were externally loaded with an intermittent hydrostatic pressure,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00165-1

    authors: Tanck E,van Driel WD,Hagen JW,Burger EH,Blankevoort L,Huiskes R

    更新日期:1999-02-01 00:00:00

  • Elastic area compressibility of the rabbit aorta.

    abstract::In this paper, we apply the micropipette to reduce the surface area of the rabbit aorta, and the relationship between the fractional area change of the aortic surface and the negative pressure in the pipette is studied. The experimental results for seven rabbit thoracic aortas show that the relationship can be express...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)00003-6

    authors: Yu Q,Wang X,Li G

    更新日期:1996-08-01 00:00:00

  • Shank and rearfoot coordination and its variability during running in flatfoot.

    abstract::Flatfoot is a risk factor for patellofemoral pain syndrome (PFPS), and excessive rearfoot eversion occurring in flatfoot has been associated with the development and progression of PFPS; however, the mechanism remains unclear. This study aimed to investigate transverse shank and frontal rearfoot coordination patterns ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110119

    authors: Takabayashi T,Edama M,Inai T,Kubo M

    更新日期:2021-01-22 00:00:00

  • A finite element musculoskeletal model of the shoulder mechanism.

    abstract::The finite element method described in this study provides an easy method to simulate the kinetics of multibody mechanisms. It is used in order to develop a musculoskeletal model of the shoulder mechanism. Each relevant morphological structure has been represented by an appropriate element. For the shoulder mechanism ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90065-5

    authors: van der Helm FC

    更新日期:1994-05-01 00:00:00

  • Index-matched measurements of the effect of cartilaginous rings on tracheobronchial flow.

    abstract::We present a comparison of the flow characteristics in an idealized smooth trachea model and a second model which has a roughness simulating cartilaginous rings. We use refractive index-matched particle image velocimetry (PIV) to measure the velocity field in a two-generation model of the trachea and main bronchi. The...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.043

    authors: Bocanegra Evans H,Castillo L

    更新日期:2016-06-14 00:00:00

  • Moment-rotation behavior of intervertebral joints in flexion-extension, lateral bending, and axial rotation at all levels of the human spine: A structured review and meta-regression analysis.

    abstract::Spinal intervertebral joints are complex structures allowing motion in multiple directions, and many experimental studies have reported moment-rotation response. However, experimental methods, reporting of results, and levels of the spine tested vary widely, and a comprehensive assessment of moment-rotation response a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,meta分析,评审

    doi:10.1016/j.jbiomech.2019.109579

    authors: Zhang C,Mannen EM,Sis HL,Cadel ES,Wong BM,Wang W,Cheng B,Friis EA,Anderson DE

    更新日期:2020-02-13 00:00:00

  • Predicting surface strains at the human distal radius during an in vivo loading task--finite element model validation and application.

    abstract::Bone strains resulting from physical activity are thought to be a primary driver of bone adaptation, but cannot be directly noninvasively measured. Because bone adapts nonuniformly, physical activity may make an important independent structural contribution to bone strength that is independent of bone mass and density...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.04.050

    authors: Bhatia VA,Edwards WB,Troy KL

    更新日期:2014-08-22 00:00:00

  • Lubricin deficiency in the murine lumbar intervertebral disc results in elevated torsional apparent modulus.

    abstract::The purpose of this study was to investigate the mechanical consequences of proteoglycan 4 (Prg4) deficiency on intervertebral disc mechanics using a Prg4 knockout mouse model. Prg4, also called lubricin, was first identified as the boundary lubricant in synovial fluid but has subsequently been localized within a numb...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.03.029

    authors: Teeple E,Aslani K,Shalvoy MR,Medrano JE,Zhang L,Machan JT,Fleming BC,Jay GD

    更新日期:2015-07-16 00:00:00

  • Comparison of tendon tensions estimated from two biomechanical models of the thumb.

    abstract::Despite the paramount function of the thumb in daily life, thumb biomechanical models have been little developed and studied. Moreover, only two studies provided quantitative anthropometric data of tendon moment arms. To investigate thumb tendon tensions, biomechanicians and clinicians have to know the performances an...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.052

    authors: Vigouroux L,Domalain M,Berton E

    更新日期:2009-08-07 00:00:00

  • Simultaneous positive and negative external mechanical work in human walking.

    abstract::In human walking, the center of mass motion is similar to an inverted pendulum. Viewing double support as a transition from one inverted pendulum to the next, we hypothesized that the leading leg performs negative work to redirect the center of mass velocity, while simultaneously, the trailing leg performs positive wo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00169-5

    authors: Donelan JM,Kram R,Kuo AD

    更新日期:2002-01-01 00:00:00

  • A three-dimensional model of the rat hindlimb: musculoskeletal geometry and muscle moment arms.

    abstract::As a first step towards developing a dynamic model of the rat hindlimb, we measured muscle attachment and joint center coordinates relative to bony landmarks using stereophotogrammetry. Using these measurements, we analyzed muscle moment arms as functions of joint angle for most hindlimb muscles, and tested the hypoth...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.10.004

    authors: Johnson WL,Jindrich DL,Roy RR,Reggie Edgerton V

    更新日期:2008-01-01 00:00:00

  • Assessment of compressive modulus, hydraulic permeability and matrix content of trypsin-treated nucleus pulposus using quantitative MRI.

    abstract::A clinical strength MRI and intact bovine caudal intervertebral discs were used to test the hypotheses that (1) mechanical loading and trypsin treatment induce changes in NMR parameters, mechanical properties and biochemical contents; and (2) mechanical properties are quantitatively related to NMR parameters. MRI acqu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.04.015

    authors: Périé D,Iatridis JC,Demers CN,Goswami T,Beaudoin G,Mwale F,Antoniou J

    更新日期:2006-01-01 00:00:00

  • Construction of healthy arteries using computed tomography and virtual histology intravascular ultrasound.

    abstract::Vessel geometry for numerical analysis is generally obtained by computed tomography (CT) or magnetic resonance imaging (MRI) and intravascular ultrasound (IVUS). Most medical imaging is obtained from patients for hemodynamic analysis due to the properties of vascular disease and the difficulties in angiography. To pre...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.04.003

    authors: Ryou HS,Kim S,Kim SW,Cho SW

    更新日期:2012-06-01 00:00:00

  • Reproducibility of energy parameters in the pole vault.

    abstract::The purpose of this study was to analyze the reproducibility of kinematic, dynamometric and derived mechanical energy parameters in the pole vault as a main precondition for the practical applicability of the concept of energy exchange in the pole vault. A total of 46 vaults of six experienced vaulters were analyzed. ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.03.027

    authors: Schade F,Arampatzis A,Brüggemann GP

    更新日期:2006-01-01 00:00:00

  • The influence of strain rate on adaptive bone remodelling.

    abstract::Bending and compressive loads were applied intermittently at 0.5 Hz through implants chronically inserted into the radius and ulna of experimental sheep. The plane of bending was the same as that imposed during locomotion. The principal variables of the artificial strain regime were the peak strains and strain rates, ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(82)90092-6

    authors: O'Connor JA,Lanyon LE,MacFie H

    更新日期:1982-01-01 00:00:00

  • Impact responses of the cervical spine: A computational study of the effects of muscle activity, torso constraint, and pre-flexion.

    abstract::Cervical spine injuries continue to be a costly societal problem. Future advancements in injury prevention depend on improved physical and computational models, which are predicated on a better understanding of the neck response during dynamic loading. Previous studies have shown that the tolerance of the neck is depe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.01.006

    authors: Nightingale RW,Sganga J,Cutcliffe H,Bass CR

    更新日期:2016-02-29 00:00:00

  • Hydro-resistive measurement of dynamic lifting strength.

    abstract::A device is described for measuring strength and power outputs of dynamic vertical lifts between heights of 0.4 and 2.2 m. The device is safe, robust, and easily transportable. It consists of a water-filled tube 2 m high and 200 mm internal diameter. The subject pulls vertically on a handle which is connected with fle...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(96)00155-8

    authors: Pinder AD,Grieve DW

    更新日期:1997-04-01 00:00:00

  • Explicit calibration method and specific device designed for stereoradiography.

    abstract::The three-dimensional geometry of the human spine is noteworthy information that can be obtained by stereoradiographic methods. These methods are based on the identification of anatomical structures in several views which are obtained by rotation of a patient standing on a turntable. Calibration algorithms for compute...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00016-2

    authors: Dumas R,Mitton D,Laporte S,Dubousset J,Steib JP,Lavaste F,Skalli W

    更新日期:2003-06-01 00:00:00

  • Effective modulus of the human intervertebral disc and its effect on vertebral bone stress.

    abstract::The mechanism of vertebral wedge fractures remains unclear and may relate to typical variations in the mechanical behavior of the intervertebral disc. To gain insight, we tested 16 individual whole discs (between levels T8 and L5) from nine cadavers (mean±SD: 66±16 years), loaded in compression at different rates (0.0...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.02.045

    authors: Yang H,Jekir MG,Davis MW,Keaveny TM

    更新日期:2016-05-03 00:00:00

  • The influence of material property and morphological parameters on specimen-specific finite element models of porcine vertebral bodies.

    abstract::The use of finite element (FE) methods in spinal research is increasing, but there is only limited information available on the influence of different input parameters on the model predictions. The aim of this study was to investigate the role of these parameters in FE models of the vertebral body. Experimental tests ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.02.005

    authors: Wilcox RK

    更新日期:2007-01-01 00:00:00

  • Muscle activities of the lower limb during level and uphill running.

    abstract::This study aimed to compare the muscle activities of the lower limb during overground level running (LR) and uphill running (UR) by using a musculoskeletal model. Six male distance runners ran at three running speeds (slow: 3.3 m/s; medium: 4.2 m/s; and high: 5.0 m/s) on a level runway and a slope of 9.1% grade in whi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.05.028

    authors: Yokozawa T,Fujii N,Ae M

    更新日期:2007-01-01 00:00:00

  • In-situ characterization of the uncrimping process of arterial collagen fibers using two-photon confocal microscopy and digital image correlation.

    abstract::Uncrimping of collagen fibers in the arterial wall is an integral process in regulating the macro-level mechanical response of arteries. Uncrimping of collagen fibers leads to a gradual, but significant strain-stiffening response of the artery at physiological pressures and prevents overdistention at elevated pressure...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.08.001

    authors: Wang R,Brewster LP,Gleason RL Jr

    更新日期:2013-10-18 00:00:00

  • A mechanistic damage model for ligaments.

    abstract:PURPOSE:The accuracy of biomechanical models is predicated on the realism by which they represent their biomechanical tissues. Unfortunately, most models use phenomenological ligament models that neglect the behaviour in the failure region. Therefore, the purpose of this investigation was to test whether a mechanistic ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.06.039

    authors: Barrett JM,Callaghan JP

    更新日期:2017-08-16 00:00:00

  • Equine subchondral bone failure threshold under impact compression applied through articular cartilage.

    abstract::Subchondral bone microdamage due to high-impact loading is a key factor leading to post-traumatic knee osteoarthritis. A quantified assessment of the mechanical characteristics of subchondral bone at the tissue-level is essential to study the mechanism of impact-induced microdamage. We combined mechanical impact testi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.05.016

    authors: Malekipour F,Oetomo D,Lee PV

    更新日期:2016-07-05 00:00:00

  • Influence of shoes and heel strike on the loading of the hip joint.

    abstract::The forces and moments acting at the hip joint influence the long-term stability of the fixation of endoprostheses and the course of coxarthrosis. These loads may depend on the kind of footwear and the walking or running style. These factors were investigated in a patient with instrumented hip implants. He wore differ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)00129-r

    authors: Bergmann G,Kniggendorf H,Graichen F,Rohlmann A

    更新日期:1995-07-01 00:00:00

  • A new transducer system for direct motor unit force measurement.

    abstract::A new transducer was developed for in situ measurement of the force vector in a complex muscle. The transducer measures the magnitude, and the line of action of a force in a single plane. The dynamic range of the transducer is 0-5 N. This range includes the small forces developed by an active motor unit and the relati...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)84545-3

    authors: Turkawski SJ,van Ruijven LJ,van Kuyen M,Schreurs AW,Weijs WA

    更新日期:1996-11-01 00:00:00

  • Fracture analysis for biological materials with an expanded cohesive zone model.

    abstract::In this study, a theoretical framework for simulation of fracture of bone and bone-like materials is provided. An expanded cohesive zone model with thermodynamically consistent framework has been proposed and used to investigate the crack growth resistance of bone and bone-like materials. The reversible elastic deform...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.04.054

    authors: An B,Zhao X,Arola D,Zhang D

    更新日期:2014-07-18 00:00:00

  • Understanding stress concentration about a nutrient foramen.

    abstract::We investigated the microstructural basis of a reduced stress concentration around the primary nutrient foramen of the equine third metacarpus. We quantified the spatial variations of compositional parameters (mineral content, volume fraction, histological architecture, and osteonal trajectories) from microradiographs...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00130-1

    authors: Götzen N,Cross AR,Ifju PG,Rapoff AJ

    更新日期:2003-10-01 00:00:00

  • In vivo kinematics and articular surface congruency of total ankle arthroplasty during gait.

    abstract::Relatively high rates of loosening and implant failure have been reported after total ankle arthroplasty. Abnormal kinematics and incongruency of the articular surface may cause increased contact pressure and rotational torque applied to the implant, leading to loosening and implant failure. We measured in vivo kinema...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.05.043

    authors: Yamaguchi S,Tanaka Y,Banks S,Kosugi S,Sasho T,Takahashi K,Takakura Y

    更新日期:2012-08-09 00:00:00