Abstract:
:Subchondral bone microdamage due to high-impact loading is a key factor leading to post-traumatic knee osteoarthritis. A quantified assessment of the mechanical characteristics of subchondral bone at the tissue-level is essential to study the mechanism of impact-induced microdamage. We combined mechanical impact testing of equine cartilage-bone with µCT image-based finite element models (μFEM) of each specimen to determine subchondral bone (including calcified cartilage: CCSB) elastic tissue modulus and local stresses and strains associated with micro-fractures within the CCSB tissue. The material properties of each specimen-specific μFEM were iteratively adjusted to match the FE-predicted stress-strain curves with experimental results. Isotropic homogeneous material properties for both uncalcified cartilage (UC) and CCSB were assumed. UC large-deformation was simulated using hyperelastic material properties. Final UC shear and CCSB tissue elastic modulus of G=38±20MPa and E(t)=3.3±0.7GPa were achieved after fit procedure. The results suggested that initial failure in CCSB occurred at local tensile and compressive stresses of 29.47±5.34 MPa and 64.3±21.3MPa, and tensile and compressive strains of 1.12±0.06% and 1.99±0.41%, respectively. Tissue-level material properties can be used in finite element modeling of diarthrodial joints under impact loading, and also in designing artificial cartilage-bone to replace the damaged tissue in the joint. Results can provide an estimate for the threshold of initial failure in subchondral bone tissue due to an impact compression transmitted through the overlying articular cartilage.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Malekipour F,Oetomo D,Lee PVdoi
10.1016/j.jbiomech.2016.05.016subject
Has Abstractpub_date
2016-07-05 00:00:00pages
2053-2059issue
10eissn
0021-9290issn
1873-2380pii
S0021-9290(16)30586-3journal_volume
49pub_type
杂志文章abstract::Materials, including bone, often fail due to loading in the presence of critical flaws. The relative amount, location, and interaction of these flaws within a stressed volume of material play a role in determining the failure properties of the structure. As materials are generally imperfect, larger volumes of material...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.05.025
更新日期:2007-01-01 00:00:00
abstract::The goal of this study is to elucidate whether mechanobiological factors, including mechanical loading patterns, presence of bone graft, and proximity to the periosteum, correlate to de novo tissue generation and healing in critical sized long bone defects, which are enveloped by periosteum in situ and are bridged at ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.06.026
更新日期:2010-10-19 00:00:00
abstract::Intramuscular pressure correlates strongly with muscle tension and is a promising tool for quantifying individual muscle force. However, clinical application is impeded by measurement variability that is not fully understood. Previous studies point to regional differences in IMP, specifically increasing pressure with ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.09.002
更新日期:2016-10-03 00:00:00
abstract::Wall shear stress distribution in the carotid siphon, which is a multiple curved segment of the internal carotid artery, is investigated numerically under physiological flow conditions. The computer simulation of flow through the model segment is based on the time-dependent, three-dimensional Navier-Stokes equations, ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(88)90203-5
更新日期:1988-01-01 00:00:00
abstract::Bone fracture reduction and bone axial dynamization are important operations which effectiveness can be further enhanced by the use of a unilateral external fixator. By design, axial dynamization can be performed through reciprocating one of its translational joints. However, non-axial dynamization may occur after cor...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.05.002
更新日期:2009-08-25 00:00:00
abstract::The more we learn about the intervertebral disc (IVD), the more we come to appreciate the intricacies involved in transmission of forces through the ECM to the cell, and in the biological determinants of its response to mechanical stress. This review highlights recent developments in our knowledge of IVD physiology an...
journal_title:Journal of biomechanics
pub_type: 杂志文章,评审
doi:10.1016/j.jbiomech.2009.09.019
更新日期:2010-01-05 00:00:00
abstract::Inferences on the active contribution of plantar flexors to the stabilisation of human standing posture have been drawn from surface electromyograms (EMGs). Surface EMGs were however often detected unilaterally, presuming the myoelectric activity from muscles in a single leg reflects the pattern of muscle activation i...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.09.018
更新日期:2018-11-16 00:00:00
abstract::Mechanical properties of abdominal and thoracic arteries of 2mm in diameter were determined from adults Wistar rats. A tensile testing instrument was used to obtain stress/strain curves with arteries immersed in physiological buffer at 37 degrees C. A displacement was applied on all arteries with various frequencies (...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.04.017
更新日期:2008-07-19 00:00:00
abstract::A composite cushion acetabular cup for a total hip replacement has been designed and developed jointly by Leeds University and DePuy International. In order to assess the long-term performance of this novel design, two sets of simulator tests of more than 4 million cycles duration have been carried out with the cushio...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(98)00034-7
更新日期:1998-04-01 00:00:00
abstract::Patient selection for lateral retinacular release (LRR) and its efficacy are controversial. Iatrogenic medial subluxation can occur with inappropriate LRR. The aim of this study was to determine the reduction in patellofemoral stability with progressively more extensive LRR. The force required to displace the patella ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.11.003
更新日期:2009-02-09 00:00:00
abstract::In order to assess the potential influence of various physical or chemical treatments on bone grafts, and in particular, on femoral heads to be used as bone grafts, the mechanical symmetry of the femoral head was investigated. Pairs of proximal human femora were harvested and transversally sliced using a coordinate sy...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(96)00061-9
更新日期:1996-10-01 00:00:00
abstract::Bone mineral density (BMD) measurements from Dual-energy X-ray Absorptiometry (DXA) alone cannot account for all factors associated with the risk of hip fractures. For example, the inhomogeneity of bone mineral density in the hip region also contributes to bone strength. In the stochastic assessment of bone inhomogene...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.01.030
更新日期:2015-04-13 00:00:00
abstract::Predicting subject-specific responses to exoskeleton assistance may aid in maximizing functional gait outcomes, such as achieving full knee-extension at foot contact in individuals with crouch gait from cerebral palsy (CP). The purpose of this study was to investigate the role of volitional and non-volitional muscle a...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.02.025
更新日期:2019-04-18 00:00:00
abstract::Rigid body attitude and single-joint kinematics are typically expressed using three Cardan angles which represent rotations in anatomical planes. It was recently shown in the Biomechanics literature that Cardan angles inaccurately estimate true mean attitude due to an important mathematical inadequacy: attitude under-...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109976
更新日期:2020-10-09 00:00:00
abstract::Nowadays in various daily, occupational and training activities, there are many occasions with forces supported in hands acting at various magnitudes, elevations, and orientations with substantial horizontal components. In this work, we aim to compute trunk muscle forces, stability, and spinal loads under pulling exte...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.09.036
更新日期:2016-04-11 00:00:00
abstract::Adhesions of monocytes and platelets to a vascular surface, particularly in regions of flow stagnation, recirculation, and reattachment, are a significant initial event in a broad spectrum of particle-wall interactions that significantly influence the formation of stenotic lesions and mural thrombi. A number of approx...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(02)00434-7
更新日期:2003-03-01 00:00:00
abstract::The trunk has a multi-segmental structure and is composed of the cervical, thoracic, and lumber spines and surrounding soft tissue elements; this allows flexible deformation during dynamic movements. The purpose of this study was to quantitatively assess trunk deformation during dynamic movement. Ten male subjects per...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.04.019
更新日期:2017-07-05 00:00:00
abstract::In quadrupeds, there have been limited comparisons of gait timing events detection (e.g., paw contact, PC and paw-off, PO) determined from kinematics and forceplates. The goal of this study was to investigate the effect of different slopes (0, -27, +27°), recovery times after ankle extensor nerve injury and repair (2,...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2012.03.013
更新日期:2012-05-11 00:00:00
abstract::We searched for the consequences of a maximal static foot inversion sustained until exhaustion on the post-exercise stationary upright standing and the proprioceptive control of the foot muscles. Twelve healthy subjects executed an unilateral maximal static foot inversion during which continuous power spectrum analyse...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.04.005
更新日期:2013-06-21 00:00:00
abstract::Continuum finite element (FE) models of bones have become a standard pre-clinical tool to estimate bone strength. These models are usually based on clinical CT scans and material properties assigned are chosen as isotropic based only on the density distribution. It has been shown, however, that trabecular bone elastic...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.07.042
更新日期:2013-09-27 00:00:00
abstract::Medical professionals, physical therapists, product designers, and computational models all use cervical spine range of motion reference values. To support these functions, researchers have collected a plethora of data to determine the normal range of motion of the cervical spine of adult subjects. However, little to ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.06.021
更新日期:2008-08-28 00:00:00
abstract::The importance of the aortic root compliance in the aortic valve performance has most frequently been ignored in computational valve modeling, although it has a significant contribution to the functionality of the valve. Aortic root aneurysm or (calcific) stiffening severely affects the aortic valve behavior and, cons...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(02)00448-7
更新日期:2003-05-01 00:00:00
abstract::We induced mild blunt and blast injuries in rats using a custom-built device and utilized in-house diffusion tensor imaging (DTI) software to reconstruct 3-D fiber tracts in brains before and after injury (1, 4, and 7 days). DTI measures such as fiber count, fiber length, and fractional anisotropy (FA) were selected t...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.09.026
更新日期:2014-11-28 00:00:00
abstract::Despite the paramount function of the thumb in daily life, thumb biomechanical models have been little developed and studied. Moreover, only two studies provided quantitative anthropometric data of tendon moment arms. To investigate thumb tendon tensions, biomechanicians and clinicians have to know the performances an...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.03.052
更新日期:2009-08-07 00:00:00
abstract::An asymptotic analysis of a lubrication problem is presented for a model of articular cartilage and synovial fluid under the squeeze-film condition. This model is based upon the following constitutive assumptions: (1) articular cartilage is a linear porous-permeable biphasic material filled with a linearly viscous flu...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(92)90024-u
更新日期:1992-03-01 00:00:00
abstract::Bone strains resulting from physical activity are thought to be a primary driver of bone adaptation, but cannot be directly noninvasively measured. Because bone adapts nonuniformly, physical activity may make an important independent structural contribution to bone strength that is independent of bone mass and density...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.04.050
更新日期:2014-08-22 00:00:00
abstract::2D, coronal plane, finite elements models (FEMs) were developed from orthogonal radiographs of a diaphyseal tibial fracture and its reparative tissue at four different time points during healing. Each callus was separated into regions of common tissue histology by computerised radiographic analysis. Starting point val...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(99)00189-x
更新日期:2000-04-01 00:00:00
abstract::Split-belt treadmills (SBTM) contain force plates under each belt that measure ground reaction force (GRF). Initial contact (IC) detection for each gait cycle obtained from the GRF is used for calculating temporal gait parameters (e.g., gait variability, step time, stride time). Occasionally, the participant steps wit...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109963
更新日期:2020-09-18 00:00:00
abstract::Cervical spine finite element models reported in biomechanical literature usually represent a static morphology. Not considering morphology as a model parameter limits the predictive capabilities for applications in personalized medicine, a growing trend in modern clinical practice. The objective of the study was to i...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.12.044
更新日期:2019-03-06 00:00:00
abstract::The structural properties of tendons and ligaments are integral to their ability to function effectively in vivo and are determined from both the geometrical form and material properties. Many studies of tendon and ligament include a mechanical assessment of the structure in vitro. However, to determine the material p...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.05.003
更新日期:2005-03-01 00:00:00