Application of a mechanobiological simulation technique to stents used clinically.

Abstract:

:Many cardiovascular diseases are characterised by the restriction of blood flow through arteries. Stents can be expanded within arteries to remove such restrictions; however, tissue in-growth into the stent can lead to restenosis. In order to predict the long-term efficacy of stenting, a mechanobiological model of the arterial tissue reaction to stress is required. In this study, a computational model of arterial tissue response to stenting is applied to three clinically relevant stent designs. We ask the question whether such a mechanobiological model can differentiate between stents used clinically, and we compare these predictions to a purely mechanical analysis. In doing so, we are testing the hypothesis that a mechanobiological model of arterial tissue response to injury could predict the long-term outcomes of stent design. Finite element analysis of the expansion of three different stent types was performed in an idealised, 3D artery. Injury was calculated in the arterial tissue using a remaining-life damage mechanics approach. The inflammatory response to this initial injury was modelled using equations governing variables which represented tissue-degrading species and growth factors. Three levels of inflammation response were modelled to account for inter-patient variability. A lattice-based model of smooth muscle cell behaviour was implemented, treating cells as discrete agents governed by local rules. The simulations predicted differences between stent designs similar to those found in vivo. It showed that the volume of neointima produced could be quantified, providing a quantitative comparison of stents. In contrast, the differences between stents based on stress alone were highly dependent on the choice of comparison criteria. These results show that the choice of stress criteria for stent comparisons is critical. This study shows that mechanobiological modelling may provide a valuable tool in stent design, allowing predictions of their long-term efficacy. The level of inflammation was shown to affect the sensitivity of the model to stent design. If this finding was verified in patients, this could suggest that high-inflammation patients may require alternative treatments to stenting.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Boyle CJ,Lennon AB,Prendergast PJ

doi

10.1016/j.jbiomech.2012.12.014

subject

Has Abstract

pub_date

2013-03-15 00:00:00

pages

918-24

issue

5

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(12)00744-0

journal_volume

46

pub_type

杂志文章
  • Density of trunk tissues of young and medium age people.

    abstract::In this study the investigations made on about 50 trunk tissue densities are described. They were performed on ten cadavers of both sexes within 24 h of the moment of death. They were 20-40 yr old. The weight of each tissue was measured on a laboratory scale and the volume by placing the tissue in a pycnometer filled ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90360-f

    authors: Erdmann WS,Gos T

    更新日期:1990-01-01 00:00:00

  • Loads on an internal spinal fixation device during sitting.

    abstract::Sitting is often assumed to involve high loads on the spine as well as on implants for stabilising the spine. Loads on internal spinal fixation devices were therefore measured in ten patients sitting on several types of seats, including a stool, a stool with a padded wedge, a chair, a physiotherapy ball, a knee-stool,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00073-2

    authors: Rohlmann A,Arntz U,Graichen F,Bergmann G

    更新日期:2001-08-01 00:00:00

  • A novel approach to assess post-yield energy dissipation of bone in tension.

    abstract::In this study, we proposed a novel approach to assess the energy dissipation during the post-yield deformation of bone. Based on the stress-strain behavior in an incremental and cyclic loading-unloading-reloading scheme in uniaxial tension, we partitioned the post-yield energy dissipation of bone into three distinct p...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.02.002

    authors: Wang X,Nyman JS

    更新日期:2007-01-01 00:00:00

  • Non-linear viscoelastic models predict fingertip pulp force-displacement characteristics during voluntary tapping.

    abstract::We evaluated whether lumped-parameter non-linear viscoelastic models of human fingertip tissue can describe fingertip force-displacement characteristics during a range of rapid, dynamic tapping tasks. Eight human subjects tapped with their index finger on the surface of a rigid load cell while an optical system tracke...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/s0021-9290(02)00438-4

    authors: Jindrich DL,Zhou Y,Becker T,Dennerlein JT

    更新日期:2003-04-01 00:00:00

  • The region-dependent dynamic properties of porcine temporomandibular joint disc under unconfined compression.

    abstract::In this study, the dynamic compressive properties in five different regions of the porcine temporomandibular joint (TMJ) disc are investigated over a wide range of loading frequencies. The aim was, thus far, to evaluate the regional difference and the frequency-related effect of the applied load on these properties. E...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.11.035

    authors: Fernández P,Jesús Lamela M,Ramos A,Fernández-Canteli A,Tanaka E

    更新日期:2013-02-22 00:00:00

  • A new system for analyzing swim fin propulsion based on human kinematic data.

    abstract::The use of swim fins has become popular in various water sport activities. While numerous models of swim fin with various innovative shapes have been subjectively designed, the exact influence of the fin characteristics on swimming performance is still much debated, and remains difficult to quantify. To date, the most...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.03.031

    authors: Nicolas G,Bideau B,Bideau N,Colobert B,Le Guerroue G,Delamarche P

    更新日期:2010-07-20 00:00:00

  • Kinematic evaluation of cruciate-retaining total knee replacement patients during level walking: a comparison with the displacement-controlled ISO standard.

    abstract::Differences between wear-scar features of simulator-tested and retrieved tibial total knee replacement (TKR) liners have been reported. This disagreement may result from differences between in vivo kinematic profiles and those defined by the International Organization for Standardization (ISO). The purpose of this stu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.06.030

    authors: Ngai V,Wimmer MA

    更新日期:2009-10-16 00:00:00

  • A theoretical model of the effect of continuum damage on a bone adaptation model.

    abstract::Throughout life, bone is continuously turning over by the well-regulated processes of bone formation and resorption. Everyday activities damage bone, and this damage is normally repaired in a continuous remodelling process. When an imbalance in this remodelling process occurs, bones may become more susceptible to frac...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00215-3

    authors: Ramtani S,Zidi M

    更新日期:2001-04-01 00:00:00

  • A technique to quantify skin displacement in the walking horse.

    abstract::A method is presented for quantitative determination of skin movement over the underlying skeletal structures during normal locomotion of the horse. The principle of the method is simultaneous visualization of the position of the skin and the underlying bony structures, by marking the bones with implanted light-emitti...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(86)90138-7

    authors: van Weeren PR,Barneveld A

    更新日期:1986-01-01 00:00:00

  • Tissue viscoelasticity is related to tissue composition but may not fully predict the apparent-level viscoelasticity in human trabecular bone - An experimental and finite element study.

    abstract::Trabecular bone is viscoelastic under dynamic loading. However, it is unclear how tissue viscoelasticity controls viscoelasticity at the apparent-level. In this study, viscoelasticity of cylindrical human trabecular bone samples (n=11, male, age 18-78 years) from 11 proximal femurs were characterized using dynamic and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.10.002

    authors: Ojanen X,Tanska P,Malo MKH,Isaksson H,Väänänen SP,Koistinen AP,Grassi L,Magnusson SP,Ribel-Madsen SM,Korhonen RK,Jurvelin JS,Töyräs J

    更新日期:2017-12-08 00:00:00

  • Bi-linear mechanical property determination of acellular human patellar tendon grafts for use in anterior cruciate ligament replacement.

    abstract::Anterior cruciate ligament rupture is rising in its prevalence amongst the young and those with physically active lifestyles. Acellular human patellar tendon (PT) grafts offer a promising restoration solution, returning knee joint stability and overcoming some of the current disadvantages of autologous or allogeneic g...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.041

    authors: Herbert A,Brown C,Rooney P,Kearney J,Ingham E,Fisher J

    更新日期:2016-06-14 00:00:00

  • The potential influence of the heel counter on internal stress during static standing: a combined finite element and positional MRI investigation.

    abstract::Confinement of the heel due to the counter of the shoe is believed to influence heel pad biomechanics. Using a two-dimensional finite element model of the heel pad and shoe during a simulation of static standing, the aim of this study was to quantify the potential effect of confinement on internal heel pad stress. Non...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.01.004

    authors: Spears IR,Miller-Young JE,Sharma J,Ker RF,Smith FW

    更新日期:2007-01-01 00:00:00

  • Influence of microcalcifications on vulnerable plaque mechanics using FSI modeling.

    abstract::Sudden heart attacks remain one of the primary causes of premature death in the developed world. Asymptomatic vulnerable plaques that rupture are believed to prompt such fatal heart attacks and strokes. The role of microcalcifications in the vulnerable plaque rupture mechanics is still debated. Recent studies suggest ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.11.029

    authors: Bluestein D,Alemu Y,Avrahami I,Gharib M,Dumont K,Ricotta JJ,Einav S

    更新日期:2008-01-01 00:00:00

  • Effects of implant design parameters on fluid convection, potentiating third-body debris ingress into the bearing surface during THA impingement/subluxation.

    abstract::Aseptic loosening from polyethylene wear debris is the leading cause of failure for metal-on-polyethylene total hip implants. Third-body debris ingress to the bearing space results in femoral head roughening and acceleration of polyethylene wear. How third-body particles manage to enter the bearing space between the c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.01.021

    authors: Lundberg HJ,Pedersen DR,Baer TE,Muste M,Callaghan JJ,Brown TD

    更新日期:2007-01-01 00:00:00

  • Effect of boundary conditions, impact loading and hydraulic stiffening on femoral fracture strength.

    abstract::Patient specific quantitative CT (QCT) imaging data together with the finite element (FE) method may provide an accurate prediction of a patient's femoral strength and fracture risk. Although numerous FE models investigating femoral fracture strength have been published, there is little consent on the effect of bounda...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.07.004

    authors: Haider IT,Speirs AD,Frei H

    更新日期:2013-09-03 00:00:00

  • Role of endplates in contributing to compression behaviors of motion segments and intervertebral discs.

    abstract::The purpose of this study was to gain an improved understanding of the mechanical behavior of the intervertebral disc in the presence and absence of the vertebral endplates. Mechanical behaviors of rat caudal motion segments, vertebrae and isolated disc explants under two different permeability conditions were investi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.11.013

    authors: MacLean JJ,Owen JP,Iatridis JC

    更新日期:2007-01-01 00:00:00

  • Muscle fatigue does not lead to increased instability of upper extremity repetitive movements.

    abstract::Muscle fatigue alters neuromuscular responses. This may lead to increased sensitivity to perturbations and possibly to subsequent injury risk. We studied the effects of muscle fatigue on movement stability during a repetitive upper extremity task. Twenty healthy young subjects performed a repetitive work task, similar...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.11.001

    authors: Gates DH,Dingwell JB

    更新日期:2010-03-22 00:00:00

  • Synergistic action of static stretching and BMP-2 stimulation in the osteoblast differentiation of C2C12 myoblasts.

    abstract::Static stretching is a major type of mechanical stimuli utilized during distraction osteogenesis (DO), a general surgical method for the lengthening of bone. The molecular signals that drive the regenerative process in DO include a variety of cytokines. Among these, bone morphogenic protein (BMP, -2 and -4) has been r...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.08.006

    authors: Kim IS,Song YM,Cho TH,Kim JY,Weber FE,Hwang SJ

    更新日期:2009-12-11 00:00:00

  • Trunk control during gait: Walking with wide and narrow step widths present distinct challenges.

    abstract::The active control of the trunk plays an important role in frontal plane gait stability. We characterized trunk control in response to different step widths using a novel feedback system and examined the different effects of wide and narrow step widths as they each present unique task demands. Twenty healthy young adu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110135

    authors: Shih HS,Gordon J,Kulig K

    更新日期:2021-01-04 00:00:00

  • Modeling of hemodynamics arising from malaria infection.

    abstract::We propose a numerical model of hemodynamics arising from malaria infection. This model is based on a particle method, where all the components of blood are represented by the finite number of particles. A two-dimensional spring network of membrane particles is employed for expressing the deformation of malaria infect...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.01.011

    authors: Imai Y,Kondo H,Ishikawa T,Teck Lim C,Yamaguchi T

    更新日期:2010-05-07 00:00:00

  • Blood and interstitial flow in the hierarchical pore space architecture of bone tissue.

    abstract::There are two main types of fluid in bone tissue, blood and interstitial fluid. The chemical composition of these fluids varies with time and location in bone. Blood arrives through the arterial system containing oxygen and other nutrients and the blood components depart via the venous system containing less oxygen an...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.12.013

    authors: Cowin SC,Cardoso L

    更新日期:2015-03-18 00:00:00

  • A three-dimensional human head finite element model and power flow in a human head subject to impact loading.

    abstract::A three-dimensional finite element model of the human head is presented. The model has been validated against two sets of experimental results. To assess injury likelihood of the head subjected to impact loading, the structural intensity (SI) methodology is introduced in accordance with the prevailing practice in expe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.11.015

    authors: Zong Z,Lee HP,Lu C

    更新日期:2006-01-01 00:00:00

  • Assessment of compressive modulus, hydraulic permeability and matrix content of trypsin-treated nucleus pulposus using quantitative MRI.

    abstract::A clinical strength MRI and intact bovine caudal intervertebral discs were used to test the hypotheses that (1) mechanical loading and trypsin treatment induce changes in NMR parameters, mechanical properties and biochemical contents; and (2) mechanical properties are quantitatively related to NMR parameters. MRI acqu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.04.015

    authors: Périé D,Iatridis JC,Demers CN,Goswami T,Beaudoin G,Mwale F,Antoniou J

    更新日期:2006-01-01 00:00:00

  • Hip contact forces and gait patterns from routine activities.

    abstract::In vivo loads acting at the hip joint have so far only been measured in few patients and without detailed documentation of gait data. Such information is required to test and improve wear, strength and fixation stability of hip implants. Measurements of hip contact forces with instrumented implants and synchronous ana...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00040-9

    authors: Bergmann G,Deuretzbacher G,Heller M,Graichen F,Rohlmann A,Strauss J,Duda GN

    更新日期:2001-07-01 00:00:00

  • Simultaneous shear and pressure sensor array for assessing pressure and shear at foot/ground interface.

    abstract::Foot ulceration is a diabetic complication estimated to result in over $1 billion worth of medical expenses per year in the United States alone. This multifaceted problem involves the response of plantar soft tissue to both external forces applied to the epidermis and internal changes such as vascular supply and neuro...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.10.001

    authors: Mackey JR,Davis BL

    更新日期:2006-01-01 00:00:00

  • Compression data on bovine bone confirms that a "stressed volume" principle explains the variability of fatigue strength results.

    abstract::The literature contains many measurements of the fatigue properties of compact bone, but these experimental results have been difficult to interpret and use due to a large amount of apparent scatter: variation in the number of cycles to failure for a given cyclic stress or strain range. Recently Taylor (1998a, Journal...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00112-8

    authors: Taylor D,O'Brien F,Prina-Mello A,Ryan C,O'Reilly P,Lee TC

    更新日期:1999-11-01 00:00:00

  • Novel isodamping dynamometer accurately measures plantar flexor function.

    abstract::Isokinetic dynamometers are the gold standard tools used to assess in vivo joint and muscle function in human subjects, however, the large size and high cost of these devices prevents their widespread use outside of traditonal biomechanics labs. In this study, we developed a mobile dynamometer to allow for field measu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110015

    authors: Drazan JF,Hullfish TJ,Baxter JR

    更新日期:2020-10-09 00:00:00

  • Mechanobiological modeling can explain orthodontic tooth movement: three case studies.

    abstract::Progress in medicine and higher expectation of quality of life has led to a higher demand for several dental and medical treatments. This increases the occurrence of situations in which orthodontic treatment is complicated by pathological conditions, medical therapies and drugs. Together with experiments, computer mod...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.10.037

    authors: Van Schepdael A,Vander Sloten J,Geris L

    更新日期:2013-02-01 00:00:00

  • The influence of center-of-mass movements on the variation in the structure of human postural sway.

    abstract::The present article investigates the influence of center-of-mass movements on the variation of the structure in human postural sway. Twelve healthy younger persons performed 60s quiet standing, 60s relaxed standing, and 10 min relaxed standing on two force plates. Center-of-pressure (CoP) and gravitational line (GL) p...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.10.016

    authors: Ihlen EA,Skjæret N,Vereijken B

    更新日期:2013-02-01 00:00:00

  • Kinematic performance of a six degree-of-freedom hand model (6DHand) for use in occupational biomechanics.

    abstract::Upper extremity musculoskeletal disorders represent an important health issue across all industry sectors; as such, the need exists to develop models of the hand that provide comprehensive biomechanics during occupational tasks. Previous optical motion capture studies used a single marker on the dorsal aspect of finge...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.04.003

    authors: Buczek FL,Sinsel EW,Gloekler DS,Wimer BM,Warren CM,Wu JZ

    更新日期:2011-06-03 00:00:00