The region-dependent dynamic properties of porcine temporomandibular joint disc under unconfined compression.

Abstract:

:In this study, the dynamic compressive properties in five different regions of the porcine temporomandibular joint (TMJ) disc are investigated over a wide range of loading frequencies. The aim was, thus far, to evaluate the regional difference and the frequency-related effect of the applied load on these properties. Eleven porcine TMJ discs were used; each disc was divided into 5 regions, anterior, central, posterior, lateral and medial. Sinusoidal compressive strain was applied with an amplitude of 1.0% and a frequency range between 0.01 and 10Hz. The dynamic storage and loss moduli increase with frequency, the highest values being attained at the posterior region, followed by the central and anterior regions. Loss tangent, tanδ, ranged from 0.20 to 0.35, which means that the disc is primarily elastic in nature and has a small but not negligible viscosity. The present results suggest that the dynamic viscoelastic compressive modulus is region-specific and depends on the loading frequency, thus having important implications for the transmission of load to the TMJ.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Fernández P,Jesús Lamela M,Ramos A,Fernández-Canteli A,Tanaka E

doi

10.1016/j.jbiomech.2012.11.035

subject

Has Abstract

pub_date

2013-02-22 00:00:00

pages

845-8

issue

4

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(12)00687-2

journal_volume

46

pub_type

杂志文章
  • Validation of a novel method for quantifying and comparing regional ACL elongations during uniaxial tensile loading.

    abstract::Given the complex three-dimensional (3D) knee joint loading associated with anterior cruciate ligament (ACL) injuries, accurate site- and bundle-specific strain measurements are critical. The purpose of this study was to quantify tensile load-induced migrations of radio-opaque markers injected directly into the ACL, a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.08.016

    authors: Beaulieu ML,Haladik JA,Bey MJ,McLean SG

    更新日期:2012-10-11 00:00:00

  • Gait in rheumatoid arthritis: an electrogoniometric investigation.

    abstract::For the purpose of detecting early aberrations of gait in rheumatoid arthritis 17 women suffering from that disease were examined. They were all under 50 years of age and had an essentially normal range of motility in the hips, knees and ankles. Eleven healthy women walking at voluntary speed and 6 healthy women walki...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90237-0

    authors: Isacson J,Broström LA

    更新日期:1988-01-01 00:00:00

  • Acquisition of full-field strain distributions on ovine fracture callus cross-sections with electronic speckle pattern interferometry.

    abstract::This study evaluated the feasibility of assessing continuous strain distributions on fracture callus cross-sections with an electronic speckle pattern interferometry (ESPI) system. Mid-sagittal callus cross-sections were harvested from ovine tibiae. One low stiffness (LS) specimen and one high stiffness (HS) specimen ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.10.024

    authors: Bottlang M,Mohr M,Simon U,Claes L

    更新日期:2008-01-01 00:00:00

  • How muscle architecture and moment arms affect wrist flexion-extension moments.

    abstract::The purpose of this investigation was to determine how the moment arms and architecture of the wrist muscles influence their isometric moment-generating characteristics. A three-dimensional computer graphic model was developed that estimates the moment arms, maximum isometric forces, and maximum isometric flexion-exte...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00015-8

    authors: Gonzalez RV,Buchanan TS,Delp SL

    更新日期:1997-07-01 00:00:00

  • Validation of an ambient system for the measurement of gait parameters.

    abstract::Fall risk in elderly people is usually assessed using clinical tests. These tests consist in a subjective evaluation of gait performed by healthcare professionals, most of the time shortly after the first fall occurrence. We propose to complement this one-time, subjective evaluation, by a more quantitative analysis of...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.01.024

    authors: Dubois A,Bresciani JP

    更新日期:2018-03-01 00:00:00

  • Effect of foods on selected dynamic parameters of mandibular elevator muscles during symmetric incisal biting.

    abstract::The paper focuses on research that enables the relationship between food and selected mechanical parameters do be determined. The main aim of the study was to designate, depending on the food: (1) the work of a single muscle (i.e. masseter, medial pterygoid, temporalis), and (2) the energy balance of mandibular elevat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109800

    authors: Stróżyk P,Jacek B

    更新日期:2020-06-09 00:00:00

  • Microcrack growth parameters for compact bone deduced from stiffness variations.

    abstract::This paper shows how information on the fatigue behaviour of microcracks can be obtained by the analysis of stiffness changes measured during cyclic loading. Relationships between crack length, growth rate and cyclic stress intensity were deduced, and compared with previous empirical equations. Results show that the c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00050-5

    authors: Taylor D

    更新日期:1998-07-01 00:00:00

  • A mechanistic damage model for ligaments.

    abstract:PURPOSE:The accuracy of biomechanical models is predicated on the realism by which they represent their biomechanical tissues. Unfortunately, most models use phenomenological ligament models that neglect the behaviour in the failure region. Therefore, the purpose of this investigation was to test whether a mechanistic ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.06.039

    authors: Barrett JM,Callaghan JP

    更新日期:2017-08-16 00:00:00

  • Segment inertial parameter evaluation in two anthropometric models by application of a dynamic linked segment model.

    abstract::The estimation of segment inertial parameters (SIPs) is an important source of error in inverse dynamic analysis. In most individual cases SIPs are derived from extrapolation of known SIPs of a certain population through regression equations (proportional models). Another well-known method is the use of mathematical a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00086-0

    authors: Kingma I,Toussaint HM,De Looze MP,Van Dieen JH

    更新日期:1996-05-01 00:00:00

  • Realistic virtual intracranial stenting and computational fluid dynamics for treatment analysis.

    abstract::In order to support the decisions of medical experts and to develop better stent designs, the availability of a simulation tool for virtual stenting would be extremely useful. An innovative virtual stenting technique is described in this work, which is directly applicable for complex patient-specific geometries. A bas...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.08.047

    authors: Janiga G,Rössl C,Skalej M,Thévenin D

    更新日期:2013-01-04 00:00:00

  • In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics.

    abstract::The objective of the current study was to use fluoroscopy to accurately determine the three-dimensional (3D), in vivo, weight-bearing kinematics of 10 normal and five anterior cruciate ligament deficient (ACLD) knees. Patient-specific bone models were derived from computed tomography (CT) data. 3D computer bone models...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2004.02.042

    authors: Dennis DA,Mahfouz MR,Komistek RD,Hoff W

    更新日期:2005-02-01 00:00:00

  • On stiffness of scaffolds for bone tissue engineering-a numerical study.

    abstract::Tissue scaffolds are typically designed and fabricated to match native bone properties. However, it is unclear if this would lead to the best tissue ingrowth outcome within the scaffold as neo-tissue keeps changing the stiffness of entire construct. This paper presents a numerical method to address this issue for desi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.02.020

    authors: Sturm S,Zhou S,Mai YW,Li Q

    更新日期:2010-06-18 00:00:00

  • Predicting timing of foot strike during running, independent of striking technique, using principal component analysis of joint angles.

    abstract::As 3-dimensional (3D) motion-capture for clinical gait analysis continues to evolve, new methods must be developed to improve the detection of gait cycle events based on kinematic data. Recently, the application of principal component analysis (PCA) to gait data has shown promise in detecting important biomechanical f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.06.009

    authors: Osis ST,Hettinga BA,Leitch J,Ferber R

    更新日期:2014-08-22 00:00:00

  • The role of muscles in joint degeneration and osteoarthritis.

    abstract::The purpose of this work was to establish a controlled and reversible muscle weakness model for studying the effects of weakness on joint degeneration leading to osteoarthritis (OA). The knee extensor muscles of rabbits were injected with single or repeat doses of Botulinum type-A toxin (BTX-A) to partially inhibit ac...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.03.001

    authors: Herzog W,Longino D

    更新日期:2007-01-01 00:00:00

  • Are mineralized tissues open crystal foams reinforced by crosslinked collagen? Some energy arguments.

    abstract::Which of the elementary components (hydroxyapatite (HA) crystals, collagen, non-collagenous organic matter, water) do significantly contribute to the ultrastructural elastic stiffness magnitude and anisotropy of mineralized tissues; and how, i.e. through which shapes and assemblages (which micromechanical morphology)?...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00080-5

    authors: Hellmich Ch,Ulm FJ

    更新日期:2002-09-01 00:00:00

  • Non-linear viscoelastic models predict fingertip pulp force-displacement characteristics during voluntary tapping.

    abstract::We evaluated whether lumped-parameter non-linear viscoelastic models of human fingertip tissue can describe fingertip force-displacement characteristics during a range of rapid, dynamic tapping tasks. Eight human subjects tapped with their index finger on the surface of a rigid load cell while an optical system tracke...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/s0021-9290(02)00438-4

    authors: Jindrich DL,Zhou Y,Becker T,Dennerlein JT

    更新日期:2003-04-01 00:00:00

  • The effect of tendon viscoelastic stiffness on the dynamic performance of isometric muscle.

    abstract::The effect of tendons viscoelastic stiffness on the dynamic response of the cat's tibialis anterior muscle under isometric conditions was determined. It was shown that the dynamic response model of the muscle derived under sinusoidal contraction-relaxation in the range of 20-80% of its maximal isometric tension was no...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90355-q

    authors: Baratta R,Solomonow M

    更新日期:1991-01-01 00:00:00

  • EMG and force production of some human shoulder muscles during isometric abduction.

    abstract::Surface EMG was recorded in four subjects on three different occasions from the three parts of the deltoid, the clavicular part of the pectoralis major and from the infraspinatus muscles at different angles of abduction, in the frontal and scapular plane. The integrated EMG was related to the maximum values found for ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(85)90037-5

    authors: Ringelberg JA

    更新日期:1985-01-01 00:00:00

  • Effect of temperature on residual force enhancement in single skeletal muscle fibers.

    abstract::It is well accepted that the steady-state isometric force following active stretching of a muscle is greater than the steady-state isometric force obtained in a purely isometric contraction at the same length. This property of skeletal muscle has been called residual force enhancement (FE). Despite decades of research...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.06.007

    authors: Lee EJ,Herzog W

    更新日期:2008-08-28 00:00:00

  • An ultrasound based non-invasive method for the measurement of intrinsic foot kinematics during gait.

    abstract::Soft tissue artefact (STA) and marker placement variability are sources of error when measuring the intrinsic kinematics of the foot. This study aims to demonstrate a non-invasive, combined ultrasound and motion capture (US/MC) technique to directly measure foot skeletal motion. The novel approach is compared to a sta...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.12.014

    authors: Telfer S,Woodburn J,Turner DE

    更新日期:2014-03-21 00:00:00

  • Prediction of closed-chain human arm dynamics in a crank-rotation task.

    abstract::This paper deals with the analysis of human arm movement in a crank-rotation task that is an example of environmentally constrained movements. Opening a door, rotating a steering wheel, and pushing a carriage are other typical examples of movements where the physical constraints, imposed on the hand position/orientati...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.05.034

    authors: Davoudabadi Farahani S,Svinin M,Andersen MS,de Zee M,Rasmussen J

    更新日期:2016-09-06 00:00:00

  • Kinematical models to reduce the effect of skin artifacts on marker-based human motion estimation.

    abstract::The estimation of the skeletal motion obtained from marker-based motion capture systems is known to be affected by significant bias caused by skin movement artifacts, which affects joint center and rotation axis estimation. Among different techniques proposed in the literature, that based on rigid body model, still th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.09.032

    authors: Cerveri P,Pedotti A,Ferrigno G

    更新日期:2005-11-01 00:00:00

  • 'Equivalent geometry' of the knee and the prediction of tensions along the cruciates: an experimental study.

    abstract::In this paper we introduce the concept of the functional (or equivalent) geometry of the knee, which is an attempt to reduce the natural knee with its complex geometry, frictional resistance and deformable cartilage into a two-dimensional joint comprising rigid femur and tibia in frictionless contact. An apparatus and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00141-9

    authors: Chan SC,Seedhom BB

    更新日期:1999-01-01 00:00:00

  • Age-related distensibility and histology of the ascending aorta in elderly patients with acute aortic dissection.

    abstract::Degradation and fragmentation of elastic fibers in the media dilate the aortic wall excessively in patients with acute Stanford type A aortic dissection (AD). Such dilatation occurs not via aortic stiffening, which is diagnosed using imaging under physiological loading, but due to the abovementioned intrinsic changes ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.06.025

    authors: Yamada H,Sakata N,Wada H,Tashiro T,Tayama E

    更新日期:2015-09-18 00:00:00

  • Cross-sectional structural parameters from densitometry.

    abstract::Bone densitometry has previously been used to obtain cross-sectional properties of bone from a single X-ray projection across the bone width. Using three unique projections, we have extended the method to obtain the principal area moments of inertia and orientations of the principal axes at each scan cross-section alo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00220-2

    authors: Cleek TM,Whalen RT

    更新日期:2002-04-01 00:00:00

  • Design of next generation total disk replacements.

    abstract::To improve the treatments for low back pain, new designs of total disk replacement have been proposed. The question is how well these designs can act as a functional replacement of the intervertebral disk. Four finite element models were made, for four different design concepts, to determine how well they can mimic th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.09.017

    authors: van den Broek PR,Huyghe JM,Wilson W,Ito K

    更新日期:2012-01-03 00:00:00

  • Multichannel strain gauge telemetry for orthopaedic implants.

    abstract::In vivo measurements of the loads and deformations occurring in orthopaedic implants will allow future improvements to be made. This paper describes an extremely small telemetry for long term measurements with three strain gauges and methods for an absolutely safe implant design. Developed for measuring the load at hi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90009-7

    authors: Bergmann G,Graichen F,Siraky J,Jendrzynski H,Rohlmann A

    更新日期:1988-01-01 00:00:00

  • Is Achilles tendon compliance optimised for maximum muscle efficiency during locomotion?

    abstract::Tendon elasticity is important for economical locomotion; however it is unknown whether tendon stiffness is appropriate to achieve an optimal efficiency in various muscles. Here we test the hypothesis that the Achilles tendon is of an appropriate stiffness to maximise medial gastrocnemius muscle efficiency during loco...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.07.025

    authors: Lichtwark GA,Wilson AM

    更新日期:2007-01-01 00:00:00

  • Force depression following muscle shortening in sub-maximal voluntary contractions of human adductor pollicis.

    abstract::Mechanical properties of skeletal muscles are often studied for controlled, electrically induced, maximal, or supra-maximal contractions. However, many mechanical properties, such as the force-length relationship and force enhancement following active muscle stretching, are quite different for maximal and sub-maximal,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.12.002

    authors: Rousanoglou EN,Oskouei AE,Herzog W

    更新日期:2007-01-01 00:00:00

  • Comparison of tendon tensions estimated from two biomechanical models of the thumb.

    abstract::Despite the paramount function of the thumb in daily life, thumb biomechanical models have been little developed and studied. Moreover, only two studies provided quantitative anthropometric data of tendon moment arms. To investigate thumb tendon tensions, biomechanicians and clinicians have to know the performances an...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.052

    authors: Vigouroux L,Domalain M,Berton E

    更新日期:2009-08-07 00:00:00