Realistic virtual intracranial stenting and computational fluid dynamics for treatment analysis.

Abstract:

:In order to support the decisions of medical experts and to develop better stent designs, the availability of a simulation tool for virtual stenting would be extremely useful. An innovative virtual stenting technique is described in this work, which is directly applicable for complex patient-specific geometries. A basilar tip aneurysm provided for the Virtual Intracranial Stenting Challenge 2010 is considered to demonstrate the advantages of this approach. A free-form deformation is introduced for a wall-tight stent deployment. Numerical flow simulations on sufficiently fine computational meshes are performed for different configurations in order to characterize the inflow rate into the aneurysm and the corresponding residence time in the aneurysm sac. A Neuroform and a SILK stent have been deployed at various locations and the computed residence times have been evaluated and compared, demonstrating the advantage associated with a lower stent porosity. It has been found that the SILK stent leads to a large increase in the residence time and to a significant reduction in the maximum wall shear stress in the aneurysm sac. This is only observed when placing the stent in the appropriate position, showing that virtual stenting might be employed for operation support.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Janiga G,Rössl C,Skalej M,Thévenin D

doi

10.1016/j.jbiomech.2012.08.047

subject

Has Abstract

pub_date

2013-01-04 00:00:00

pages

7-12

issue

1

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(12)00523-4

journal_volume

46

pub_type

杂志文章
  • Geometrical resolution limits and detection mechanisms in the oral cavity.

    abstract::The objective of this work is to gain more insight into the processes of oral perception of food texture. Particularly, the limits for detectable thickness differences of objects, which are evaluated in the human mouth, are investigated. In a sensory study small, flexible circular disks (diameter in mm range) of varyi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.04.012

    authors: Strassburg J,Burbidge A,Delgado A,Hartmann C

    更新日期:2007-01-01 00:00:00

  • Non-invasive quantification of peripheral arterial volume distensibility and its non-linear relationship with arterial pressure.

    abstract::Arterial wall function is associated with different physiological and clinical factors. Changes in arterial pressure cause major changes in the arterial wall. This study presents a simple non-invasive method to quantify arterial volume distensibility changes with different arterial pressures. The electrocardiogram, fi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.02.011

    authors: Zheng D,Murray A

    更新日期:2009-05-29 00:00:00

  • Strain imaging of the lateral collateral ligament using high frequency and conventional ultrasound imaging: An ex-vivo comparison.

    abstract::Recent first attempts of in situ ultrasound strain imaging in collateral ligaments encountered a number of challenges and illustrated a clear need for additional studies and more thorough validation of the available strain imaging methods. Therefore, in this study we experimentally validated ultrasound strain measurem...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.03.035

    authors: Gijsbertse K,Sprengers A,Naghibi Beidokhti H,Nillesen M,de Korte C,Verdonschot N

    更新日期:2018-05-17 00:00:00

  • Mechanical behaviour of femoral bones in bending loading.

    abstract::A series of 33 human femoral bones have been subjected to a four point bending test at high strain rates. Two different failure modes were recognized. A Y shaped fracture at the middle region induced by a pure bending moment yielded a zone of non-linearity at the load vs deformation curve and a higher bending force, m...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(86)90021-7

    authors: Martens M,van Audekercke R,de Meester P,Mulier JC

    更新日期:1986-01-01 00:00:00

  • Effect of implementing magnetic resonance imaging for patient-specific OpenSim models on lower-body kinematics and knee ligament lengths.

    abstract:BACKGROUND:OpenSim models are typically based on cadaver findings that are generalized to represent a wide range of populations, which curbs their validity. Patient-specific modelling through incorporating magnetic resonance imaging (MRI) improves the model's biofidelity with respect to joint alignment and articulation...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.11.016

    authors: Smale KB,Conconi M,Sancisi N,Krogsgaard M,Alkjaer T,Parenti-Castelli V,Benoit DL

    更新日期:2019-01-23 00:00:00

  • Humans control stride-to-stride stepping movements differently for walking and running, independent of speed.

    abstract::As humans walk or run, external (environmental) and internal (physiological) disturbances induce variability. How humans regulate this variability from stride-to-stride can be critical to maintaining balance. One cannot infer what is "controlled" based on analyses of variability alone. Assessing control requires quant...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.05.034

    authors: Dingwell JB,Bohnsack-McLagan NK,Cusumano JP

    更新日期:2018-07-25 00:00:00

  • Preload substantially influences the intervertebral disc stiffness in loading-unloading cycles of compression.

    abstract::Disc hydration is controlled by fluid imbibition and exudation and hence by applied load magnitude and history, internal osmotic pressure and disc conditions. It affects both the internal load distribution and external load-bearing of a disc while variations therein give rise to the disc time-dependent characteristics...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.05.006

    authors: Schmidt H,Shirazi-Adl A,Schilling C,Dreischarf M

    更新日期:2016-06-14 00:00:00

  • Canine intersegmental hip joint forces and moments before and after cemented total hip replacement.

    abstract::Intersegmental forces and moments (i.e. resultant free body forces and moments computed at the joint centers) were studied in canine hindlimbs before and after cemented total hip replacement (THR). Five large, adult, mixed-breed dogs were selected. Their gait was recorded (while leash-walked) before surgery using high...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90028-l

    authors: Dogan S,Manley PA,Vanderby R Jr,Kohles SS,Hartman LM,McBeath AA

    更新日期:1991-01-01 00:00:00

  • Effects of aging on hip abductor-adductor neuromuscular and mechanical performance during the weight transfer phase of lateral protective stepping.

    abstract::Aging brings about challenges in the ability to recover balance through protective stepping, especially in the lateral direction. Previous work has suggested that lateral protective stepping during weight transfer may be affected by impaired muscle composition and performance of the hip abductors (AB) in older adults....

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.10.040

    authors: Inacio M,Creath R,Rogers MW

    更新日期:2019-01-03 00:00:00

  • Failure of mineralized collagen fibrils: modeling the role of collagen cross-linking.

    abstract::Experimental evidence demonstrates that collagen cross-linking in bone tissue significantly influences its deformation and failure behavior yet difficulties exist in determining the independent biomechanical effects of collagen cross-linking using in vitro and in vivo experiments. The aim of this study is to use a nan...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.02.017

    authors: Siegmund T,Allen MR,Burr DB

    更新日期:2008-01-01 00:00:00

  • Spatial phenotyping of the endocardial endothelium as a function of intracardiac hemodynamic shear stress.

    abstract::Despite substantial evidence for the central role of hemodynamic shear stress in the functional integrity of vascular endothelial cells, hemodynamic and molecular regulation of the endocardial endothelium lining the heart chambers remains understudied. We propose that regional differences in intracardiac hemodynamics ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.018

    authors: McCormick ME,Manduchi E,Witschey WRT,Gorman RC,Gorman JH 3rd,Jiang YZ,Stoeckert CJ Jr,Barker AJ,Yoon S,Markl M,Davies PF

    更新日期:2017-01-04 00:00:00

  • The mechanical effects of different levels of cement penetration at the cement-bone interface.

    abstract::The mechanical effects of varying the depth of cement penetration in the cement-bone interface were investigated using finite element analysis (FEA) and validated using companion experimental data. Two FEA models of the cement-bone interface were created from micro-computed tomography data and the penetration of cemen...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.11.033

    authors: Waanders D,Janssen D,Mann KA,Verdonschot N

    更新日期:2010-04-19 00:00:00

  • Finite element modeling reveals complex strain mechanics in the aponeuroses of contracting skeletal muscle.

    abstract::A finite element model was used to investigate the counter-intuitive experimental observation that some regions of the aponeuroses of a loaded and contracting muscle may shorten rather than undergo an expected lengthening. The model confirms the experimental findings and suggests that pennation angle plays a significa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.01.005

    authors: Chi SW,Hodgson J,Chen JS,Reggie Edgerton V,Shin DD,Roiz RA,Sinha S

    更新日期:2010-05-07 00:00:00

  • High frequency components of bone strain in dogs measured during various activities.

    abstract::Rubin et al. [J. Biomechanics 23, 43-54 (1990)] proposed that high frequency bone strains in the 15-30 Hz range might have significant influence on the morphological adaptation of bone tissue. We sought to further their findings by determining the magnitude of high frequency strains during various activities. We measu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)80005-0

    authors: Turner CH,Yoshikawa T,Forwood MR,Sun TC,Burr DB

    更新日期:1995-01-01 00:00:00

  • Efficiency as a predictor of human jaw design in the sagittal plane.

    abstract::The effects of changing the direction of the bite force and of the mandibular joint reaction have been studied with a mathematical model assisted by a computer using the technique of linear programming. We conclude the following: In the sagittal plane the long axes of lower molars are each tilted in the direction that...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90246-6

    authors: Baragar FA,Osborn JW

    更新日期:1987-01-01 00:00:00

  • Flat medial-lateral conformity in total knee replacements does not minimize contact stresses.

    abstract::The potential for wear in UHMWPE components for total knee replacements can be reduced by decreasing the stresses and strains arising from tibial-femoral contact. The conformity of the articular surfaces has a large effect on the resultant stresses, and components that achieve flat medial-lateral contact have been ass...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00172-5

    authors: Rawlinson JJ,Bartel DL

    更新日期:2002-01-01 00:00:00

  • Pure moment testing for spinal biomechanics applications: Fixed versus sliding ring cable-driven test designs.

    abstract::In vitro multi-axial bending testing using pure moment loading conditions has become the standard in evaluating the effects of different types of surgical intervention on spinal kinematics. Simple, cable-driven experimental set-ups have been widely adopted because they require little infrastructure. Traditionally, "fi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.02.004

    authors: Eguizabal J,Tufaga M,Scheer JK,Ames C,Lotz JC,Buckley JM

    更新日期:2010-05-07 00:00:00

  • Strain-induced damage reduces echo intensity changes in tendon during loading.

    abstract::Tendon functionality is related to its mechanical properties. Tendon damage leads to a reduction in mechanical strength and altered biomechanical behavior, and therefore leads to compromised ability to carry out normal functions such as joint movement and stabilization. Damage can also accumulate in the tissue and lea...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.04.004

    authors: Duenwald-Kuehl S,Lakes R,Vanderby R Jr

    更新日期:2012-06-01 00:00:00

  • Kinematic evaluation of cruciate-retaining total knee replacement patients during level walking: a comparison with the displacement-controlled ISO standard.

    abstract::Differences between wear-scar features of simulator-tested and retrieved tibial total knee replacement (TKR) liners have been reported. This disagreement may result from differences between in vivo kinematic profiles and those defined by the International Organization for Standardization (ISO). The purpose of this stu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.06.030

    authors: Ngai V,Wimmer MA

    更新日期:2009-10-16 00:00:00

  • Microcrack growth parameters for compact bone deduced from stiffness variations.

    abstract::This paper shows how information on the fatigue behaviour of microcracks can be obtained by the analysis of stiffness changes measured during cyclic loading. Relationships between crack length, growth rate and cyclic stress intensity were deduced, and compared with previous empirical equations. Results show that the c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00050-5

    authors: Taylor D

    更新日期:1998-07-01 00:00:00

  • Specimen dimensions influence the measurement of material properties in tendon fascicles.

    abstract::Stress, strain and modulus are regularly used to characterize material properties of tissue samples. However, when comparing results from different studies it is evident the reported material properties, particularly failure strains, vary hugely. The aim of our study was to characterize how and why specimen length and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.04.040

    authors: Legerlotz K,Riley GP,Screen HR

    更新日期:2010-08-26 00:00:00

  • An analysis of the squeeze-film lubrication mechanism for articular cartilage.

    abstract::An asymptotic analysis of a lubrication problem is presented for a model of articular cartilage and synovial fluid under the squeeze-film condition. This model is based upon the following constitutive assumptions: (1) articular cartilage is a linear porous-permeable biphasic material filled with a linearly viscous flu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90024-u

    authors: Hou JS,Mow VC,Lai WM,Holmes MH

    更新日期:1992-03-01 00:00:00

  • Elastic area compressibility of the rabbit aorta.

    abstract::In this paper, we apply the micropipette to reduce the surface area of the rabbit aorta, and the relationship between the fractional area change of the aortic surface and the negative pressure in the pipette is studied. The experimental results for seven rabbit thoracic aortas show that the relationship can be express...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)00003-6

    authors: Yu Q,Wang X,Li G

    更新日期:1996-08-01 00:00:00

  • A thermodynamically consistent constitutive equation for the elastic force-length relation of soft biological materials.

    abstract::Starting from the laws of thermodynamics of reversible processes, a temperature-dependent constitutive equation is derived for the elastic force-length relation of soft biological tissues. These tissues are composed of a network of fibres (mainly collagen). The equation is based on a model which uses a simplified two-...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90222-4

    authors: Maes M,Vanhuyse VJ,Decraemer WF,Raman ER

    更新日期:1989-01-01 00:00:00

  • The role of muscles in joint degeneration and osteoarthritis.

    abstract::The purpose of this work was to establish a controlled and reversible muscle weakness model for studying the effects of weakness on joint degeneration leading to osteoarthritis (OA). The knee extensor muscles of rabbits were injected with single or repeat doses of Botulinum type-A toxin (BTX-A) to partially inhibit ac...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.03.001

    authors: Herzog W,Longino D

    更新日期:2007-01-01 00:00:00

  • A comparison of methods to quantify control of the spine.

    abstract::Low back pain (LBP) affects many individuals worldwide. The established association between LBP and spine motor control has led to the development of many control assessment techniques. To understand spine control and LBP, it is essential to know the relationship between assessment techniques. Systems identification (...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109344

    authors: Bourdon E,Graham RB,van Diëen J

    更新日期:2019-11-11 00:00:00

  • Accuracy of a contour-based biplane fluoroscopy technique for tracking knee joint kinematics of different speeds.

    abstract::While measuring knee motion in all six degrees of freedom is important for understanding and treating orthopaedic knee pathologies, traditional motion capture techniques lack the required accuracy. A variety of model-based biplane fluoroscopy techniques have been developed with sub-millimeter accuracy. However, no stu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.08.045

    authors: Giphart JE,Zirker CA,Myers CA,Pennington WW,LaPrade RF

    更新日期:2012-11-15 00:00:00

  • A two-dimensional fluid-structure interaction model of the aortic valve [correction of value].

    abstract::Failure of synthetic heart valves is usually caused by tearing and calcification of the leaflets. Leaflet fiber-reinforcement increases the durability of these valves by unloading the delicate parts of the leaflets, maintaining their physiological functioning. The interaction of the valve with the surrounding fluid is...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00068-3

    authors: De Hart J,Peters GW,Schreurs PJ,Baaijens FP

    更新日期:2000-09-01 00:00:00

  • Modeling aqueous humor collection from the human eye.

    abstract::Glaucoma is a common cause of blindness. Studies of this disease can involve collection of aqueous humor (AH) fluid from eyes of patients undergoing surgery, which involves aspirating a small fluid volume from the anterior region of the eye through a fine-bore needle. Unfortunately, the composition of the AH is spatia...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.07.025

    authors: Kapnisis K,Doormaal MV,Ross Ethier C

    更新日期:2009-11-13 00:00:00

  • Differences in 3D vs. 2D analysis in lumbar spinal fusion simulations.

    abstract::Lumbar interbody fusion is currently the gold standard in treating patients with disc degeneration or segmental instability. Despite it having been used for several decades, the non-union rate remains high. A failed fusion is frequently attributed to an inadequate mechanical environment after instrumentation. Finite e...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.03.009

    authors: Hsu HW,Bashkuev M,Pumberger M,Schmidt H

    更新日期:2018-04-27 00:00:00