Simultaneous shear and pressure sensor array for assessing pressure and shear at foot/ground interface.

Abstract:

:Foot ulceration is a diabetic complication estimated to result in over $1 billion worth of medical expenses per year in the United States alone. This multifaceted problem involves the response of plantar soft tissue to both external forces applied to the epidermis and internal changes such as vascular supply and neuropathy. Increasing evidence indicates that a combination of elevated external forces (pressure and shear) and altered tissue properties is key to the etiology of foot ulcers. The overall goal of this research is to develop a platform-type hardware system that will allow a clinician to measure three-dimensional stress tensors (i.e. pressure and shear patterns) on the plantar surface and identify areas of concern. Experimental results have demonstrated that an optical approach can provide clear indication of both shear and pressure from 50 to 400 kPa with a frequency response of 100 Hz, a stress measurement accuracy of 100 Pa and a spatial resolution of 8.0mm. Initial evaluation of the system shows strong correlation between (i) applied shear and normal stress loads and (ii) the optical phase retardance computed for each stress axis of the polymer-based stress-sensing elements. These special sensing elements are designed to minimize the need for repeated calibration procedures-an issue that has plagued other attempts to develop multisensor shear and pressure systems.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Mackey JR,Davis BL

doi

10.1016/j.jbiomech.2005.10.001

keywords:

subject

Has Abstract

pub_date

2006-01-01 00:00:00

pages

2893-7

issue

15

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(05)00444-6

journal_volume

39

pub_type

杂志文章
  • Comparison of marker models for the analysis of the volume variation and thoracoabdominal motion pattern in untrained and trained participants.

    abstract::Respiratory assessment and the biomechanical analysis of chest and abdomen motion during breathing can be carried out using motion capture systems. An advantage of this methodology is that it allows analysis of compartmental breathing volumes, thoraco-abdominal patterns, percentage contribution of each compartment and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.05.036

    authors: Massaroni C,Piaia Silvatti A,Levai IK,Dickinson J,Winter S,Schena E,Silvestri S

    更新日期:2018-07-25 00:00:00

  • Functional strain in bone tissue as an objective, and controlling stimulus for adaptive bone remodelling.

    abstract::The skeleton consists of a series of elements with a variety of functions. In locations where shape or protection are of prime importance the bone's architecture is achieved during growth under direct genetic control. In locations where resistance to repetitive loading is important only the general form of the bone wi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/0021-9290(87)90026-1

    authors: Lanyon LE

    更新日期:1987-01-01 00:00:00

  • Calculation of impingement-free combined cup and stem alignments based on the patient-specific pelvic tilt.

    abstract::Proper cup alignment is crucial in total hip arthroplasty for reducing impingement risks, dislocations and wear. The Lewinnek "safe zone" is often used in clinical routine. This safe zone does not consider functional aspects and dislocation can occur even when the cup is oriented within the safe zone. Functional safe ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.10.020

    authors: Hsu J,de la Fuente M,Radermacher K

    更新日期:2019-01-03 00:00:00

  • Influence of shoes and heel strike on the loading of the hip joint.

    abstract::The forces and moments acting at the hip joint influence the long-term stability of the fixation of endoprostheses and the course of coxarthrosis. These loads may depend on the kind of footwear and the walking or running style. These factors were investigated in a patient with instrumented hip implants. He wore differ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)00129-r

    authors: Bergmann G,Kniggendorf H,Graichen F,Rohlmann A

    更新日期:1995-07-01 00:00:00

  • Calf muscle moment, work and efficiency in level walking; role of series elasticity.

    abstract::Moment and work of the human calf muscles in level walking were determined by means of an EMG to force processor, based on a muscle analogue (Hof and Van den Berg (1981) J. Biomechanics, 14, 747-758, 759-770, 771-785, 787-792). Nine subjects (four women, five men) walked on a level treadmill at speeds between 0.5 and ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(83)90067-2

    authors: Hof AL,Geelen BA,Van den Berg J

    更新日期:1983-01-01 00:00:00

  • A first estimation of prestress in so-called circularly fibered osteonic lamellae.

    abstract::The existence and role of prestress in the various hierarchical structures of long bone are long standing questions. In this study, the prestress and associated strain that exist in a component of human bone microstructure, circularly fibered osteonic lamella, are estimated. Such estimates allow the formulation of hyp...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00080-9

    authors: Ascenzi MG

    更新日期:1999-09-01 00:00:00

  • Inter-segmental coordination: motor pattern in humans stepping over an obstacle with mechanical ankle joint friction.

    abstract::This study examined the influence of a mechanical perturbation of the ankle joint on obstacle avoidance pattern. A decoupled control between the distal joint and the combined (hip-knee) proximal joints was observed according to the task requirement. In this context, a greater mechanical friction at the ankle should be...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2004.07.019

    authors: Gueguen N,Charbonneau M,Robert G,Coyle T,Prince F,Mouchnino L

    更新日期:2005-07-01 00:00:00

  • A rigid body model for the assessment of glenohumeral joint mechanics: Influence of osseous defects on range of motion and dislocation.

    abstract::The purpose of this study was to employ subject-specific computer models to evaluate the interaction of glenohumeral range-of-motion and Hill-Sachs humeral head bone defect size on engagement and shoulder dislocation. We hypothesized that the rate of engagement would increase as defect size increased, and that greater...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.11.001

    authors: Welsh MF,Willing RT,Giles JW,Athwal GS,Johnson JA

    更新日期:2016-02-29 00:00:00

  • Musculo-articular modelling of the triceps brachii.

    abstract::With the aim of proposing modelling equations for the length, force and shortening velocity of the triceps brachii, an X-ray and biomechanical study was carried out on the elbow joint. Two series of three upper right limbs removed from cadavers were used. It allowed us to situate the articular rotational axis of the e...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00032-1

    authors: Gerbeaux M,Turpin E,Lensel-Corbeil G

    更新日期:1996-02-01 00:00:00

  • The range of axial rotation of the glenohumeral joint.

    abstract::There is a paucity of data in the literature on the restraining effects of the glenohumeral (GH) ligaments; cadaveric testing is one of the best methods for determining the function of these types of tissues. The aim of this work was to commission a custom-made six degrees of freedom (dof) joint loading apparatus and ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.007

    authors: Southgate DF,Hill AM,Alexander S,Wallace AL,Hansen UN,Bull AM

    更新日期:2009-06-19 00:00:00

  • Turbulence model choice for the calculation of drag forces when using the CFD method.

    abstract::The aim of this work is to specify which model of turbulence is the most adapted in order to predict the drag forces that a swimmer encounters during his movement in the fluid environment. For this, a Computational Fluid Dynamics (CFD) analysis has been undertaken with a commercial CFD code (Fluent). The problem was m...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.010

    authors: Zaïdi H,Fohanno S,Taïar R,Polidori G

    更新日期:2010-02-10 00:00:00

  • Sex differences in active tibialis anterior stiffness evaluated using supersonic shear imaging.

    abstract::This study aimed to evaluate the sex difference in active muscle stiffness of the tibialis anterior muscle (TA) through shear modulus measurements performed using supersonic shear imaging (SSI) technique. Twenty-five women and twenty-one men participated in this study. Joint torque, electromyographic (EMG) activity an...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.08.008

    authors: Souron R,Bordat F,Farabet A,Belli A,Feasson L,Nordez A,Lapole T

    更新日期:2016-10-03 00:00:00

  • Frequency content of normal and diabetic plantar pressure profiles: implications for the selection of transducer sizes.

    abstract::How small do pressure transducers need to be in order to faithfully measure the plantar pressure profiles (PPPs) under normal and diabetic feet? In this study, pressures were collected from five diabetic and six non-diabetic subjects using a commercial measurement system with 25 mm2 transducers. Discrete Fourier Trans...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00116-6

    authors: Davis BL,Cothren RM,Quesada P,Hanson SB,Perry JE

    更新日期:1996-07-01 00:00:00

  • Smaller, stiffer coronary bypass can moderate or reverse the adverse effects of wave reflections.

    abstract::The question of whether the mechanical stiffness of a coronary bypass or that of a diseased coronary artery can have a significant effect on the hemodynamics in these vessels is addressed analytically, with emphasis on the effects of wave reflections. The analysis is based on a model of the vessels involved, and the r...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00113-0

    authors: Alderson H,Zamir M

    更新日期:2001-11-01 00:00:00

  • Stress relaxation of human ankles is only minimally affected by knee and ankle angle.

    abstract::Comprehensive characterization of stress relaxation in musculotendinous structures is needed to create robust models of viscoelastic behavior. The commonly used quasi-linear viscoelastic (QLV) theory requires that the relaxation response be independent of tissue strain (length). This study aims to characterize stress ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.11.017

    authors: Tian M,Hoang PD,Gandevia SC,Bilston LE,Herbert RD

    更新日期:2010-03-22 00:00:00

  • No need for particle tracing: from accumulating fluid properties to novel blood coagulation model in the lattice Boltzmann method.

    abstract::The accumulation of a fluid property from the standpoint of a particle moving with non-steady fluid flow (i.e., platelet/blood-cell damage index in pulsating blood flow) is a challenged computational problem due to the current need for particle-tracing methods. The method we developed (dubbed VPI) enables the approxim...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.11.011

    authors: Moiseyev G,Bar-Yoseph PZ

    更新日期:2010-03-22 00:00:00

  • A numerical method for simulating the dynamics of human walking.

    abstract::This paper presents a general method for simulating the movement of the lower extremity during human walking. It is based upon two separate algorithms: one for single support (an open kinematic chain), and the other for the double support phase (a closed-loop linkage). Central to each of these is the recursive Newton-...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90250-3

    authors: Pandy MG,Berme N

    更新日期:1988-01-01 00:00:00

  • The effect of isolated valgus moments on ACL strain during single-leg landing: a simulation study.

    abstract::Valgus moments on the knee joint during single-leg landing have been suggested as a risk factor for anterior cruciate ligament (ACL) injury. The purpose of this study was to test the influence of isolated valgus moment on ACL strain during single-leg landing. Physiologic levels of valgus moments from an in vivo study ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.10.031

    authors: Shin CS,Chaudhari AM,Andriacchi TP

    更新日期:2009-02-09 00:00:00

  • Novel isodamping dynamometer accurately measures plantar flexor function.

    abstract::Isokinetic dynamometers are the gold standard tools used to assess in vivo joint and muscle function in human subjects, however, the large size and high cost of these devices prevents their widespread use outside of traditonal biomechanics labs. In this study, we developed a mobile dynamometer to allow for field measu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110015

    authors: Drazan JF,Hullfish TJ,Baxter JR

    更新日期:2020-10-09 00:00:00

  • Moment-rotation behavior of intervertebral joints in flexion-extension, lateral bending, and axial rotation at all levels of the human spine: A structured review and meta-regression analysis.

    abstract::Spinal intervertebral joints are complex structures allowing motion in multiple directions, and many experimental studies have reported moment-rotation response. However, experimental methods, reporting of results, and levels of the spine tested vary widely, and a comprehensive assessment of moment-rotation response a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,meta分析,评审

    doi:10.1016/j.jbiomech.2019.109579

    authors: Zhang C,Mannen EM,Sis HL,Cadel ES,Wong BM,Wang W,Cheng B,Friis EA,Anderson DE

    更新日期:2020-02-13 00:00:00

  • Interpersonal coordination analysis of tennis players from different levels during official matches.

    abstract::The purpose of this study was to assess the interpersonal coordination during official male tennis matches in players of different skill levels. Players' trajectories of three levels (Juvenile, ATP-Future, ATP-250) were obtained using video-based tracking system. A vector coding technique was applied to obtain players...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.11.036

    authors: Pereira TJC,van Emmerik REA,Misuta MS,Barros RML,Moura FA

    更新日期:2018-01-23 00:00:00

  • Principles of determination and verification of muscle forces in the human musculoskeletal system: Muscle forces to minimise bending stress.

    abstract::While there are a growing number of increasingly complex methodologies available to model geometry and material properties of bones, these models still cannot accurately describe physical behaviour of the skeletal system unless the boundary conditions, especially muscular loading, are correct. Available in vivo measur...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2009.09.049

    authors: Sverdlova NS,Witzel U

    更新日期:2010-02-10 00:00:00

  • Longitudinal strain of canine and porcine aortas.

    abstract::The in situ longitudinal strain of canine and porcine aortas was investigated. Marks of black water-resistant ink were placed on the aortas and the axial lengths between the marks were measured in situ and in vitro. When the aortas were cut, the retraction was measured and described by the stretch ratio, which is defi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)00091-h

    authors: Han HC,Fung YC

    更新日期:1995-05-01 00:00:00

  • Non-linear rotation-free shell finite-element models for aortic heart valves.

    abstract::Hyperelastic material models have been incorporated in the rotation-free, large deformation, shell finite element (FE) formulation of (Stolarski et al., 2013) and applied to dynamic simulations of aortic heart valve. Two models used in the past in analysis of such problem i.e. the Saint-Venant and May-Newmann-Yin (MNY...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.031

    authors: Gilmanov A,Stolarski H,Sotiropoulos F

    更新日期:2017-01-04 00:00:00

  • Mechanical and geometrical properties of the rat semimembranosus lateralis muscle during isometric contractions.

    abstract::The orientation of the line of pull and geometrical characteristics of rat semimembranosus lateralis muscle (SM1) were measured in a plane during isometric contractions at different muscle lengths. The orientation of the line of pull was always similar in our plane of analysis. It was always aligned with the external ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90051-5

    authors: Willems ME,Huijing PA

    更新日期:1994-09-01 00:00:00

  • Fibroblast-seeded collagen gels in response to dynamic equibiaxial mechanical stimuli: A biomechanical study.

    abstract::The remodeling of fibroblast-seeded collagen gels in response to dynamic mechanical stimuli was investigated by using a newly developed biaxial culture system capable of cyclically stretching planar soft tissues. Fibroblast-seeded collagen gels were subjected to three distinct dynamic mechanical conditions for six day...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.07.030

    authors: Lee PY,Liu YC,Wang MX,Hu JJ

    更新日期:2018-09-10 00:00:00

  • Digital volume correlation and micro-CT: An in-vitro technique for measuring full-field interface micromotion around polyethylene implants.

    abstract::Micromotion around implants is commonly measured using displacement-sensor techniques. Due to the limitations of these techniques, an alternative approach (DVC-μCT) using digital volume correlation (DVC) and micro-CT (μCT) was developed in this study. The validation consisted of evaluating DVC-μCT based micromotion ag...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.05.024

    authors: Sukjamsri C,Geraldes DM,Gregory T,Ahmed F,Hollis D,Schenk S,Amis A,Emery R,Hansen U

    更新日期:2015-09-18 00:00:00

  • Uncertainty quantification of wall shear stress in intracranial aneurysms using a data-driven statistical model of systemic blood flow variability.

    abstract::Adverse wall shear stress (WSS) patterns are known to play a key role in the localisation, formation, and progression of intracranial aneurysms (IAs). Complex region-specific and time-varying aneurysmal WSS patterns depend both on vascular morphology as well as on variable systemic flow conditions. Computational fluid...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.10.005

    authors: Sarrami-Foroushani A,Lassila T,Gooya A,Geers AJ,Frangi AF

    更新日期:2016-12-08 00:00:00

  • Passive stress-strain relation for the right ventricle in diastole.

    abstract::Wall thickness and medial line radii of an in vitro canine heart are measured. These data are assumed to be characteristic of the in vivo ventricles subject to zero pressure, and in the absence of filling. The myocardium is taken to be homogeneous, isotropic, non-linearly elastic, and incompressible. The right ventric...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(82)90171-3

    authors: Moskowitz SE

    更新日期:1982-01-01 00:00:00

  • Simulation of orthotropic microstructure remodelling of cancellous bone.

    abstract::A computational model of adaptive bone remodelling is formulated as an optimization problem of instantaneous changes in microstructure that minimize a functional describing the structure quality rate. Microstructure is locally described by a set of scalar geometric parameters. Macroscopic (continuum) elastic propertie...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.09.045

    authors: Kowalczyk P

    更新日期:2010-02-10 00:00:00