Fibroblast-seeded collagen gels in response to dynamic equibiaxial mechanical stimuli: A biomechanical study.

Abstract:

:The remodeling of fibroblast-seeded collagen gels in response to dynamic mechanical stimuli was investigated by using a newly developed biaxial culture system capable of cyclically stretching planar soft tissues. Fibroblast-seeded collagen gels were subjected to three distinct dynamic mechanical conditions for six days: Cyclic Equibiaxial Stretching at two constant strain magnitudes (CES-7% and CES-20%), and Cyclic Equibiaxial Stretching with incrementally Increasing stain magnitude (ICES, 7% → 15% → 20% each for two days). The frequency of cyclic stretching was set at 1 Hz. At the end of culture, mechanical properties of the gels were examined by biaxial mechanical testing and checked again upon the removal of seeded cells. Collagen microstructure within the gels was illustrated by multiphoton microscopy. The mRNA levels of collagen type I and type III and fibronectin in the cells were examined by reverse transcription PCR. The protein expression of α-smooth muscle actin was detected by immunohistochemistry. We found that the gels cultured under cyclic stretching were stiffer than those cultured under static stretching. Particularly, the stiffness appeared to be significantly enhanced when the ICES was employed. The enhancement of mechanical properties by cyclic stretching appeared to persist upon cell removal, suggesting an irreversible remodeling of extracellular matrix. Second harmonic generation images showed that collagen fibers became thicker and more compact in the gels cultured under cyclic stretching, which may explain the mechanical findings. The mRNA expression of collagen type I in the cells of the ICES was significantly greater than that of the other groups except for the CES-20%. This study suggests that when cyclic stretching is to be used in engineering soft tissues, incrementally increasing strain magnitude may prove useful in the development of the tissue.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Lee PY,Liu YC,Wang MX,Hu JJ

doi

10.1016/j.jbiomech.2018.07.030

subject

Has Abstract

pub_date

2018-09-10 00:00:00

pages

134-142

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(18)30612-2

journal_volume

78

pub_type

杂志文章
  • Motor unit acceleration maps and interference mechanomyographic distribution.

    abstract::The study analyses the two-dimensional distribution of surface mechanomyographic (MMG) signal generated by the activation of single motor units located in three transverse positions in the tibialis anterior muscle. In 12 healthy volunteers, surface MMG signals were recorded from the tibialis anterior muscle with a 3 x...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.07.007

    authors: Farina D,Li X,Madeleine P

    更新日期:2008-09-18 00:00:00

  • The effect of step-wise increased stretching on rat calvarial osteoblast collagen production.

    abstract::Mechanical forces regulate the function of bone cells. In this paper, the effects of cyclic stretching on osteoblasts derived from rat calvaria were studied at a magnitude occurring in physiological loaded bone tissue. A four-point bending apparatus was used to apply cyclic stretching on osteoblasts. Stretching at 500...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00237-9

    authors: Tang LL,Wang YL,Pan J,Cai SX

    更新日期:2004-01-01 00:00:00

  • Bone remodelling algorithms incorporating both strain and microdamage stimuli.

    abstract::Biomechanical theories to predict bone remodelling have used either mechanical strain or microdamage as the stimulus driving cellular responses. Even though experimental data have implicated both stimuli in bone cell regulation, a mechano-regulatory system incorporating both stimuli has not yet been proposed. In this ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.05.007

    authors: McNamara LM,Prendergast PJ

    更新日期:2007-01-01 00:00:00

  • Mass properties of the human mandible.

    abstract::Computer simulation of human masticatory dynamics requires specification of the jaw's mass properties. These are difficult to estimate, especially in living subjects. Here, we used calibrated computed tomography (CT) to determine the properties of eight osseous jaw specimens with adult dentitions. When the CT numbers ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00057-x

    authors: Zhang F,Peck CC,Hannam AG

    更新日期:2002-07-01 00:00:00

  • A simulation study of vertical jumping from different starting postures.

    abstract::This paper addresses the question of whether maximal vertical jump height depends on initial jumping posture. A direct dynamics computer simulation approach was used to avoid subject preference and practice effects. The human body was modeled as four rigid segments connected by ideal hinge joints, with movement constr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)00030-9

    authors: Selbie WS,Caldwell GE

    更新日期:1996-09-01 00:00:00

  • Development of an RSA calibration system with improved accuracy and precision.

    abstract::In this study, a new radiostereometric analysis (RSA) calibration cage was developed with the aim of improving the accuracy and precision of RSA. This development consisted of three steps: a numerical simulation technique was first used to design the new cage; a synthetic imaging method was then implemented to predict...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.11.012

    authors: Cai R,Yuan X,Rorabeck C,Bourne RB,Holdsworth DW

    更新日期:2008-01-01 00:00:00

  • A new instrumentation system for training rowers.

    abstract::A dry-land rowing system was developed to provide the coach and/or athlete with quantitative information about the athlete's kinetics and kinematics while the athlete trains. This system consists of a Concept II rowing ergometer instrumented with a force transducer and potentiometer, four electrogoniometers attached t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00139-6

    authors: Hawkins D

    更新日期:2000-02-01 00:00:00

  • Quantitative assessment of trunk deformation during running.

    abstract::The trunk has a multi-segmental structure and is composed of the cervical, thoracic, and lumber spines and surrounding soft tissue elements; this allows flexible deformation during dynamic movements. The purpose of this study was to quantitatively assess trunk deformation during dynamic movement. Ten male subjects per...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.04.019

    authors: Kudo S,Fujimoto M,Isaka T,Nagano A

    更新日期:2017-07-05 00:00:00

  • The between-day reliability of peroneus longus EMG during walking.

    abstract::The peroneus longus (PL) is a rearfoot evertor, important in frontal plane foot motion. Studying PL function has been limited by previous electromyography (EMG) studies reporting poor between-day reliability. Due to its close proximity to adjacent muscles, EMG measures of PL may be susceptible to crosstalk, thus corre...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.01.037

    authors: Reeves J,Jones R,Liu A,Bent L,Nester C

    更新日期:2019-03-27 00:00:00

  • Simulation of mechanical behavior of temperature-responsive braided stents made of shape memory polyurethanes.

    abstract::Polymeric stents can be considered as an alternative to metallic stents thanks to their lessened incidence of restenosis and controlled deployment. The purpose of this study was to investigate the feasibility of developing a temperature-responsive braided stent using shape memory polyurethane (SMPU) through finite ele...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.032

    authors: Kim JH,Kang TJ,Yu WR

    更新日期:2010-03-03 00:00:00

  • Nanomechanical properties of individual chondrocytes and their developing growth factor-stimulated pericellular matrix.

    abstract::The nanomechanical properties of individual cartilage cells (chondrocytes) and their aggrecan and collagen-rich pericellular matrix (PCM) were measured via atomic force microscope nanoindentation using probe tips of two length scales (nanosized and micron-sized). The properties of cells freshly isolated from cartilage...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.04.004

    authors: Ng L,Hung HH,Sprunt A,Chubinskaya S,Ortiz C,Grodzinsky A

    更新日期:2007-01-01 00:00:00

  • Structural and mechanical properties of the human Achilles tendon: Sex and strength effects.

    abstract::Tendons are elastic structures that connect muscle to the skeletal system and transmit force relative to the amount of stretch they experience. The mechanical properties of human tendons are difficult to measure non-invasively, so generic values are often assumed in musculoskeletal models to represent all subjects. We...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.06.009

    authors: Morrison SM,Dick TJ,Wakeling JM

    更新日期:2015-09-18 00:00:00

  • Computational modeling of neuromuscular response to swing-phase robotic knee extension assistance in cerebral palsy.

    abstract::Predicting subject-specific responses to exoskeleton assistance may aid in maximizing functional gait outcomes, such as achieving full knee-extension at foot contact in individuals with crouch gait from cerebral palsy (CP). The purpose of this study was to investigate the role of volitional and non-volitional muscle a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.02.025

    authors: Lerner ZF,Damiano DL,Bulea TC

    更新日期:2019-04-18 00:00:00

  • The Cybermouse: a simple method of describing the trajectory of the human mandible in three dimensions.

    abstract::A simple method of recording the three-dimensional movements of the mandible together with up to 10 channels of other physiological data is described. The system is based on a commercially available device, the Cybermouse (IPC, Freemont, CA, U.S.A.), consisting of a lightweight ultrasonic emitter which can be attached...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00012-2

    authors: Prinz JF

    更新日期:1997-06-01 00:00:00

  • Surface roughness parameters as predictors of anchorage strength in bone: a critical analysis.

    abstract::The surface roughness of a bone implant was defined parametrically. The values of the parameters defining the surface were varied. Some traditionally used surface roughness parameters were calculated. By means of a theoretical model the bone-implant interfacial shear strength was estimated. No simple correlation betwe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00045-2

    authors: Hansson S

    更新日期:2000-10-01 00:00:00

  • Effects of different initial foot positions on kinematics, muscle activation patterns, and postural control during a sit-to-stand in younger and older adults.

    abstract:BACKGROUND:Performing a sit-to-stand (STS) can be a challenging task for older adults because of age-related declines in neuromuscular strength and coordination. We investigated the effects of different initial foot positions (IFPs) on kinematics, muscle activation patterns, and balance control during a STS in younger ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2021.110251

    authors: Jeon W,Hsiao HY,Griffin L

    更新日期:2021-01-13 00:00:00

  • Altered osteogenic commitment of human mesenchymal stem cells by ERM protein-dependent modulation of cellular biomechanics.

    abstract::Cellular mechanics is known to play an important role in many cellular functions including adhesion, migration, proliferation, and differentiation. Human mesenchymal stem cells (hMSCs) demonstrate unique mechanical properties distinct from fully differentiated cells. This observation suggests that the stem cell mechan...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.07.024

    authors: Titushkin I,Cho M

    更新日期:2011-10-13 00:00:00

  • The effect of isokinetic dynamometer deceleration phase on maximum ankle joint range of motion and plantar flexor mechanical properties tested at different angular velocities.

    abstract::During range of motion (max-ROM) tests performed on an isokinetic dynamometer, the mechanical delay between the button press (by the participant to signal their max-ROM) and the stopping of joint rotation resulting from system inertia induces errors in both max-ROM and maximum passive joint moment. The present study a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.05.036

    authors: Pinto MD,Wilson CJ,Kay AD,Cochrane J,Blazevich AJ

    更新日期:2019-07-19 00:00:00

  • Water in hydroxyapatite nanopores: Possible implications for interstitial bone fluid flow.

    abstract::The role of bone water in the activity of this organ is essential in structuring apatite crystals, providing pathways for nutrients and waste involved in the metabolism of bone cells and participating in bone remodelling mechanotransduction. It is commonly accepted that bone presents three levels of porosity, namely t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.07.025

    authors: Lemaire T,Pham TT,Capiez-Lernout E,de Leeuw NH,Naili S

    更新日期:2015-09-18 00:00:00

  • No need for particle tracing: from accumulating fluid properties to novel blood coagulation model in the lattice Boltzmann method.

    abstract::The accumulation of a fluid property from the standpoint of a particle moving with non-steady fluid flow (i.e., platelet/blood-cell damage index in pulsating blood flow) is a challenged computational problem due to the current need for particle-tracing methods. The method we developed (dubbed VPI) enables the approxim...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.11.011

    authors: Moiseyev G,Bar-Yoseph PZ

    更新日期:2010-03-22 00:00:00

  • An in vitro experimental study on the relationship between pulsatile tinnitus and the dehiscence/thinness of sigmoid sinus cortical plate.

    abstract::Pulsatile tinnitus (PT), characterized as pulse-synchronous, is generally objective. Sigmoid sinus (SS) venous sound is widely suggested to be a possible sound source of PT. The dehiscence and thinness of SS cortical plate (CP) was commonly reported as PT pathology in previous studies, but lack quantitative or biomech...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.12.049

    authors: Tian S,Fan X,Wang Y,Liu Z,Wang L

    更新日期:2019-02-14 00:00:00

  • Stress relaxation behaviors of articular cartilages in porcine temporomandibular joint.

    abstract::In this study, we tested the compressive stress relaxation behaviors of the mandibular condylar and temporal cartilages in the porcine temporomandibular joint (TMJ). The aim was to determine the quantitative and qualitative similarities and differences of compressive stress relaxation behaviors between the two cartila...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.03.007

    authors: Tanaka E,Pelayo F,Kim N,Lamela MJ,Kawai N,Fernández-Canteli A

    更新日期:2014-05-07 00:00:00

  • Numerical simulation of unsteady laminar flow through a tilting disk heart valve: prediction of vortex shedding.

    abstract::Heart valves induce flow disturbances which play a role in blood cell activation and damage, but questions of the magnitude and spatial distribution of fluid stresses (wall shear stress and turbulent stress) cannot be readily addressed with current experimental techniques. Therefore, a numerical simulation procedure f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90015-9

    authors: Huang ZJ,Merkle CL,Abdallah S,Tarbell JM

    更新日期:1994-04-01 00:00:00

  • Moment-rotation behavior of intervertebral joints in flexion-extension, lateral bending, and axial rotation at all levels of the human spine: A structured review and meta-regression analysis.

    abstract::Spinal intervertebral joints are complex structures allowing motion in multiple directions, and many experimental studies have reported moment-rotation response. However, experimental methods, reporting of results, and levels of the spine tested vary widely, and a comprehensive assessment of moment-rotation response a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,meta分析,评审

    doi:10.1016/j.jbiomech.2019.109579

    authors: Zhang C,Mannen EM,Sis HL,Cadel ES,Wong BM,Wang W,Cheng B,Friis EA,Anderson DE

    更新日期:2020-02-13 00:00:00

  • An experimental setup for the measurement of forces on a human cadaveric foot during inversion.

    abstract::An experimental setup was developed for statically measuring seven vertical and three horizontal reaction forces on the foot. In the setup, the leg can be simultaneously loaded (1) by a vertical force, (2) by an externally applied axial moment, and (3) by simulated muscle forces. The foot is free to invert under influ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90080-8

    authors: Ottevanger EJ,Spoor CW,van Leeuwen JL,Sauren AA,Janssen JD,Huson A

    更新日期:1989-01-01 00:00:00

  • Mechanical stretch inhibits mesenchymal stem cell adipogenic differentiation through TGFβ1/Smad2 signaling.

    abstract::Mesenchymal stem cells (MSCs) are the common precursors of several functionally disparate cell lineages. A plethora of chemical and physical stimuli contribute to lineage decisions and guidance, including mechanical stretch concomitant with physical movement. Here, we examined how stretch regulates MSC differentiation...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.08.013

    authors: Li R,Liang L,Dou Y,Huang Z,Mo H,Wang Y,Yu B

    更新日期:2015-10-15 00:00:00

  • Validation of an ambient system for the measurement of gait parameters.

    abstract::Fall risk in elderly people is usually assessed using clinical tests. These tests consist in a subjective evaluation of gait performed by healthcare professionals, most of the time shortly after the first fall occurrence. We propose to complement this one-time, subjective evaluation, by a more quantitative analysis of...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.01.024

    authors: Dubois A,Bresciani JP

    更新日期:2018-03-01 00:00:00

  • Comparison between in vivo and theoretical bite performance: using multi-body modelling to predict muscle and bite forces in a reptile skull.

    abstract::In biomechanical investigations, geometrically accurate computer models of anatomical structures can be created readily using computed-tomography scan images. However, representation of soft tissue structures is more challenging, relying on approximations to predict the muscle loading conditions that are essential in ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.05.037

    authors: Curtis N,Jones ME,Lappin AK,O'Higgins P,Evans SE,Fagan MJ

    更新日期:2010-10-19 00:00:00

  • Comparison of two methods for calculating the frictional properties of articular cartilage using a simple pendulum and intact mouse knee joints.

    abstract::In attempts to better understand the etiology of osteoarthritis, a debilitating joint disease that results in the degeneration of articular cartilage (AC) in synovial joints, researchers have focused on joint tribology, the study of joint friction, lubrication, and wear. Several different approaches have been used to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.05.024

    authors: Drewniak EI,Jay GD,Fleming BC,Crisco JJ

    更新日期:2009-08-25 00:00:00

  • Simulation of quadrupedal locomotion using a rigid body model.

    abstract::Locomotion of the horse is simulated using a mathematical model based on rigid body dynamics. A general method to generate the equations of motion for a two-dimensional rigid body model with an arbitrary number of hinge joints is presented and a numerical solution method, restricted to tree-structured models, is descr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90182-6

    authors: van den Bogert AJ,Schamhardt HC,Crowe A

    更新日期:1989-01-01 00:00:00