Stress relaxation behaviors of articular cartilages in porcine temporomandibular joint.

Abstract:

:In this study, we tested the compressive stress relaxation behaviors of the mandibular condylar and temporal cartilages in the porcine temporomandibular joint (TMJ). The aim was to determine the quantitative and qualitative similarities and differences of compressive stress relaxation behaviors between the two cartilages. Ten porcine TMJs were used; the articular surface was divided into 5 regions: anterior, central, posterior, lateral and medial. Compressive relaxation test was carried out at a strain level of 5% in each region of the two cartilages. The stress relaxation was monitored over a period of 5min. In all the regions of the two cartilages, the time-dependent stress relaxation curves showed a marked drop in stress within the initial 10s, which can be fitted by a standard linear viscoelastic model. The instantaneous moduli in the temporal cartilage were dominantly larger than those in the condylar cartilage, while the condylar cartilage had slightly larger relaxation moduli than the temporal cartilage except for the medial region. The both cartilages showed the regional differences in the compressive stress relaxation behavior, and in the temporal cartilage the lateral and medial regions revealed the largest values for the instantaneous and relaxation moduli. The present results demonstrate that the viscoelastic properties of compressive stress relaxation in both cartilages are region-specific, which might have an important implication for stress distribution and transmission along with the TMJ disc.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Tanaka E,Pelayo F,Kim N,Lamela MJ,Kawai N,Fernández-Canteli A

doi

10.1016/j.jbiomech.2014.03.007

subject

Has Abstract

pub_date

2014-05-07 00:00:00

pages

1582-7

issue

7

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(14)00161-4

journal_volume

47

pub_type

杂志文章
  • Shank and rearfoot coordination and its variability during running in flatfoot.

    abstract::Flatfoot is a risk factor for patellofemoral pain syndrome (PFPS), and excessive rearfoot eversion occurring in flatfoot has been associated with the development and progression of PFPS; however, the mechanism remains unclear. This study aimed to investigate transverse shank and frontal rearfoot coordination patterns ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110119

    authors: Takabayashi T,Edama M,Inai T,Kubo M

    更新日期:2021-01-22 00:00:00

  • 3D printed clamps improve spine specimen fixation in biomechanical testing.

    abstract::This study presents an anatomically customizable fixation technique for biomechanical spine experiments using a 3D printed clamping system. The aim of this study is to evaluate the feasibility and compare the fixation rigidity of the novel technique to PMMA potting with and without screw augmentation. For this purpose...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109467

    authors: Cornaz F,Fasser MR,Spirig JM,Snedeker JG,Farshad M,Widmer J

    更新日期:2020-01-02 00:00:00

  • Elastic area compressibility of the rabbit aorta.

    abstract::In this paper, we apply the micropipette to reduce the surface area of the rabbit aorta, and the relationship between the fractional area change of the aortic surface and the negative pressure in the pipette is studied. The experimental results for seven rabbit thoracic aortas show that the relationship can be express...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)00003-6

    authors: Yu Q,Wang X,Li G

    更新日期:1996-08-01 00:00:00

  • Walking speed and spatiotemporal step mean measures are reliable during feedback-controlled treadmill walking; however, spatiotemporal step variability is not reliable.

    abstract::The purpose of the study was to compare the effects of a feedback-controlled treadmill (FeedbackTM) to a traditional fixed-speed treadmill (FixedTM) on spatiotemporal gait means, variability, and dynamics. The study also examined inter-session reliability when using the FeedbackTM. Ten young adults walked on the Feedb...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.11.051

    authors: Wiens C,Denton W,Schieber MN,Hartley R,Marmelat V,Myers SA,Yentes JM

    更新日期:2019-01-23 00:00:00

  • Effect of variable periodontal ligament thickness and its non-linear material properties on the location of a tooth's centre of resistance.

    abstract::In orthodontics, the 3D translational and rotational movement of a tooth is determined by the force-moment system applied and the location of the tooth's centre of resistance (CR). Because of the practical constraints of in-vivo experiments, the finite element (FE) method is commonly used to determine the CR. The obje...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.07.043

    authors: Schmidt F,Lapatki BG

    更新日期:2019-09-20 00:00:00

  • Relationship between ankle muscle and joint kinetics during the stance phase of locomotion in the cat.

    abstract::The purpose of this study was to examine the relationship between internal force production in selected skeletal muscles and the externally calculated joint moment during overground locomotion in the adult cat. Hindlimb segments were modelled as a linked system of rigid bodies and a generalized muscle moment (GMM), th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90010-c

    authors: Fowler EG,Gregor RJ,Hodgson JA,Roy RR

    更新日期:1993-04-01 00:00:00

  • Long-term implant fixation and stress-shielding in total hip replacement.

    abstract::Implant fixation implies a strong and durable mechanical bond between the prosthetic component and host skeleton. Assuming the short-term impediments to implant fixation are successfully addressed and that longer-term issues such as late infection and mechanical failure of the components are avoided, the biological re...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2014.12.021

    authors: Sumner DR

    更新日期:2015-03-18 00:00:00

  • Influence of curvature dynamics on pulsatile coronary artery flow in a realistic bifurcation model.

    abstract::The coronary arteries undergo large dynamic variations during each cardiac cycle due to their position on the beating heart. The local artery curvature varies significantly. In this study the influence of dynamic curvature on coronary artery hemodynamics is analyzed numerically. A realistic model of the bifurcation of...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.01.021

    authors: Prosi M,Perktold K,Ding Z,Friedman MH

    更新日期:2004-11-01 00:00:00

  • Cross sectional area measurement of tendon and ligament in vitro: a simple, rapid, non-destructive technique.

    abstract::The structural properties of tendons and ligaments are integral to their ability to function effectively in vivo and are determined from both the geometrical form and material properties. Many studies of tendon and ligament include a mechanical assessment of the structure in vitro. However, to determine the material p...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.05.003

    authors: Goodship AE,Birch HL

    更新日期:2005-03-01 00:00:00

  • Compressive creep behavior of bovine trabecular bone.

    abstract::There are almost no published data that describe the creep behavior of trabecular bone (at the specimen level), even though the creep behavior of cortical bone has been well documented. In an effort to characterize the creep behavior of trabecular bone and to compare it with that of cortical bone, we performed uniaxia...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/0021-9290(94)90006-x

    authors: Bowman SM,Keaveny TM,Gibson LJ,Hayes WC,McMahon TA

    更新日期:1994-03-01 00:00:00

  • A robust method to estimate the largest Lyapunov exponent of noisy signals: A revision to the Rosenstein's algorithm.

    abstract::This study proposed a revision to the Rosenstein's method of numerical calculation of the largest Lyapunov exponent (LyE) to make it more robust to noise. To this aim, the effect of increasing number of initial neighboring points on the LyE value was investigated and compared to values obtained by filtering the time s...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.01.013

    authors: Mehdizadeh S

    更新日期:2019-03-06 00:00:00

  • The selection of a standard convention for analyzing gait data based on the analysis of relevant biomechanical factors.

    abstract::The gait cycle is usually analyzed using one of two conventions: heel contact initiates the cycle and stance is followed by swing phases or toe-off initiates the cycle and swing then stance phases are analyzed. The purpose of the study is to demonstrate that based on a consideration of relevant biomechanical measures,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90025-6

    authors: DeVita P

    更新日期:1994-04-01 00:00:00

  • Does weightlifting increase residual force enhancement?

    abstract::The force maintained following stretching of an active muscle exceeds the isometric force at the same muscle length. This residual force enhancement (RFE) is different for various muscles. It is currently unknown whether training induces changes in RFE. Weightlifters perform a large number of eccentric contractions du...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.05.017

    authors: Siebert T,Kurch D,Blickhan R,Stutzig N

    更新日期:2016-07-05 00:00:00

  • Bisphosphonate treatment in the oim mouse model alters bone modeling during growth.

    abstract::Osteogenesis imperfecta (OI) is a heritable disease, which results from an abnormal amount or structure of Type I collagen. Bisphosphonates, a class of synthetic antiresorptive drugs, used in osteoporosis management, are also used to decrease fracture incidence and improve quality of life in children with OI. In this ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.09.028

    authors: Rao SH,Evans KD,Oberbauer AM,Martin RB

    更新日期:2008-12-05 00:00:00

  • The effect of surface area digitizations on the prediction of spherical anatomical geometries for computer-assisted applications.

    abstract::Intraoperative digitization of osseous structures is an integral component of computer-assisted orthopaedic surgery. This study determined the repeatability and accuracy of predicting known radii and center locations of spherical objects for different proportions of digitized surface areas and various sphere sizes. Al...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.01.018

    authors: Whitney KD,Ferreira LM,King GJ,Johnson JA

    更新日期:2009-05-29 00:00:00

  • Comparison of biomechanical failure criteria for abdominal aortic aneurysm.

    abstract::Medical doctors consider a surgery option for the expanding abdominal aortic aneurysm (AAA) when its maximum diameter reaches 5.5cm. This simple geometrical criterion may possibly underestimate the risks of rupture of small aneurysms as well as overestimate the risks of rupture of large aneurysms. Biomechanical criter...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.03.024

    authors: Volokh KY

    更新日期:2010-07-20 00:00:00

  • Lung injury risk assessment during blast exposure.

    abstract::Blast pulmonary trauma are common consequences of modern war and terrorism action. To better protect soldiers from that threat, the injury risk level when protected and unprotected must be assessed. Knowing from the literature that a possible amplification of the blast threat would be provided by some thoracic protect...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.02.011

    authors: Boutillier J,Deck C,De Mezzo S,Magnan P,Prat N,Willinger R,Naz P

    更新日期:2019-03-27 00:00:00

  • Reliability of medial-longitudinal-arch measures for skin-markers based kinematic analysis.

    abstract::The medial-longitudinal arch (MLA) is perhaps the most important feature characterizing foot morphology. While current skin-markers based models of the MLA angle used in stereophotogrammetry allow to estimate foot arch shape and deformation, these do not always appear consistent with foot anatomy and with standard cli...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.03.017

    authors: Caravaggi P,Matias AB,Taddei UT,Ortolani M,Leardini A,Sacco ICN

    更新日期:2019-05-09 00:00:00

  • The compressive stiffness of human pediatric heads.

    abstract::Head injury is a persistent and costly problem for both children and adults. Globally, approximately 10 million people are hospitalized each year for head injuries. Knowing the structural properties of the head is important for modeling the response of the head in impact, and for providing insights into mechanisms of ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.08.024

    authors: Loyd AM,Nightingale RW,Luck JF,Song Y,Fronheiser L,Cutcliffe H,Myers BS,Dale Bass CR

    更新日期:2015-11-05 00:00:00

  • Computational analysis of flow structure and particle deposition in a single asthmatic human airway bifurcation.

    abstract::This paper aims to improve current understanding of flow structure and particle deposition in asthmatic human airways. A single, symmetric airway bifurcation, corresponding to generations 10-11 of Weibel's model, is investigated through validated numerical simulations. The parent airway segment is modelled as a smooth...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.05.031

    authors: Zhang H,Papadakis G

    更新日期:2010-09-17 00:00:00

  • A laser-aligned method for anthropometry of hands.

    abstract::We have developed a laser-aligned measuring device to facilitate the measurement of linear hand dimensions. Our objective has been to make a simple, clinically applicable device for anthropometry of the hands in patients with arthritis in order to gauge the progression of hand deformities. The system provides an alter...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00121-0

    authors: Highton J,Davidson P,Markham V

    更新日期:2003-09-01 00:00:00

  • Measuring dynamic stability requirements during sitting pivot transfers using stabilizing and destabilizing forces in individuals with complete motor paraplegia.

    abstract::Dynamic stability requirements have never been quantified when long-term manual wheelchair users transfer themselves in a seated position from an initial surface to a target surface, a functional task commonly referred to as sitting pivot transfers (SPTs). Ten individuals with spinal cord injury (SCI), who rely on a m...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.02.018

    authors: Gagnon D,Duclos C,Desjardins P,Nadeau S,Danakas M

    更新日期:2012-05-11 00:00:00

  • A three-dimensional model of the rat hindlimb: musculoskeletal geometry and muscle moment arms.

    abstract::As a first step towards developing a dynamic model of the rat hindlimb, we measured muscle attachment and joint center coordinates relative to bony landmarks using stereophotogrammetry. Using these measurements, we analyzed muscle moment arms as functions of joint angle for most hindlimb muscles, and tested the hypoth...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.10.004

    authors: Johnson WL,Jindrich DL,Roy RR,Reggie Edgerton V

    更新日期:2008-01-01 00:00:00

  • Reconstruction of proximal humeral fractures without screws using a reinforced bone substitute.

    abstract::Multi-fragment fractures are still a challenge: current clinical practice relies on plates and screws. Treatment of fractures of the proximal humerus has the intra-operative risk of articular damage when inserting multiple screws. Distal-varus collapse of the head is a frequent complication in osteoporotic patients. T...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110138

    authors: Cristofolini L,Ruspi ML,Marras D,Cavallo M,Guerra E

    更新日期:2021-01-22 00:00:00

  • External sensory-motor cues while managing unexpected slippages can violate the planar covariation law.

    abstract::This study was aimed at investigating the intersegmental coordination of six older adults while managing unexpected slippages delivered during steady walking, and wearing an Active Pelvis Orthosis (APO). The APO was setup either to assist volunteers at the hip levels during balance loss or to be transparent. The Plana...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.01.003

    authors: Aprigliano F,Monaco V,Micera S

    更新日期:2019-03-06 00:00:00

  • Mechanical interaction between neighboring muscles in human upper limb: Evidence for epimuscular myofascial force transmission in humans.

    abstract::To confirm the existence of epimuscular myofascial force transmission in humans, this study examined if manipulating joint angle to stretch the muscle can alter the shear modulus of a resting adjacent muscle, and whether there are regional differences in this response. The biceps brachii (BB: manipulated muscle) and t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.04.036

    authors: Yoshitake Y,Uchida D,Hirata K,Mayfield DL,Kanehisa H

    更新日期:2018-06-06 00:00:00

  • Effects of extracellular fiber architecture on cell membrane shear stress in a 3D fibrous matrix.

    abstract::Interstitial fluid flow has been shown to affect the organization and behavior of cells in 3D environments in vivo and in vitro, yet the forces driving such responses are not clear. Due to the complex architecture of the extracellular matrix (ECM) and the difficulty of measuring fluid flow near cells embedded in it, t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.06.023

    authors: Pedersen JA,Boschetti F,Swartz MA

    更新日期:2007-01-01 00:00:00

  • Nanomechanical properties of individual chondrocytes and their developing growth factor-stimulated pericellular matrix.

    abstract::The nanomechanical properties of individual cartilage cells (chondrocytes) and their aggrecan and collagen-rich pericellular matrix (PCM) were measured via atomic force microscope nanoindentation using probe tips of two length scales (nanosized and micron-sized). The properties of cells freshly isolated from cartilage...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.04.004

    authors: Ng L,Hung HH,Sprunt A,Chubinskaya S,Ortiz C,Grodzinsky A

    更新日期:2007-01-01 00:00:00

  • In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics.

    abstract::The objective of the current study was to use fluoroscopy to accurately determine the three-dimensional (3D), in vivo, weight-bearing kinematics of 10 normal and five anterior cruciate ligament deficient (ACLD) knees. Patient-specific bone models were derived from computed tomography (CT) data. 3D computer bone models...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2004.02.042

    authors: Dennis DA,Mahfouz MR,Komistek RD,Hoff W

    更新日期:2005-02-01 00:00:00

  • Influence of prosthetic humeral head size and medial offset on the mechanics of the shoulder with cuff tear arthropathy: a numerical study.

    abstract::This numerical study assesses the influence of an oversized humeral hemiprosthesis with a larger medial offset on the mechanics of the shoulder with cuff tear arthropathy (CTA). Shoulder elevation in the scapular plane is performed, and a Seebauer Type IIa CTA is simulated: a massive rotator cuff tear, a proximal and ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.11.021

    authors: Lemieux PO,Tétreault P,Hagemeister N,Nuño N

    更新日期:2013-02-22 00:00:00