Abstract:
:Multi-fragment fractures are still a challenge: current clinical practice relies on plates and screws. Treatment of fractures of the proximal humerus has the intra-operative risk of articular damage when inserting multiple screws. Distal-varus collapse of the head is a frequent complication in osteoporotic patients. The aim of this biomechanical study was to investigate if an Innovative-cement-technique (the screws are replaced by injection of cement) provides the same or better stability of the reconstructed head compared to the Standard-technique (locking screws). A four-fragment fracture was simulated in twelve pairs of humeri, with removal of part of the cancellous bone to simulate osteoporotic "eggshell" defect. One humerus of each pair was repaired either with a Standard-technique (locking plate, 2 cortical and 6 locking screws), or with the Innovative-cement-technique (injection of a partially-resorbable reinforced bone substitute consisting of PMMA additivated with 26% beta-TCP). Cement injection was performed both in the lab and under fluoroscopic monitoring. The reconstructed specimens were tested to failure with a cyclic force of increasing amplitude. The Innovative-cement-technique withstood a force 3.57 times larger than the contralateral Standard reconstructions before failure started. The maximum force before final collapse for the Innovative-cement-technique was 3.56 times larger than the contralateral Standard-technique. These differences were statistically significant. The Innovative-cement-technique, based on the reinforced bone substitute, demonstrated better biomechanical properties compared to the Standard-technique. These findings, along with the advantage of avoiding the possible complications associated with the locking screws, may help safer and more effective treatment in case of osteoporotic multi-fragment humeral fractures.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Cristofolini L,Ruspi ML,Marras D,Cavallo M,Guerra Edoi
10.1016/j.jbiomech.2020.110138subject
Has Abstractpub_date
2021-01-22 00:00:00pages
110138eissn
0021-9290issn
1873-2380pii
S0021-9290(20)30562-5journal_volume
115pub_type
杂志文章abstract::Data on articular cartilage thickness in the living are important for the design for computer models, aimed at preoperatively assessing the effect of surgical procedures on joint contact and load transmission, and for the calculation of cartilage material properties from its deformational behavior as determined during...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(97)81146-3
更新日期:1997-03-01 00:00:00
abstract::The effects and interaction of the anatomical displacements in the human knee are a prerequisite to an accurate assessment and communication of the kinematic data. For the kinematic information to be used to improve diagnosis and treatment, and for better prosthetic design and installation, there must be clear, concis...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(90)90378-g
更新日期:1990-01-01 00:00:00
abstract::Bone is a biological nanocomposite composed primarily of collagen and hydroxyapatite. The collagen molecules self-assemble to from a structure known as a fibril that comprises of about 85-95% of the total bone protein. In a fibril, the molecular level interactions at the interface between molecular collagen and hydrox...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.02.027
更新日期:2010-06-18 00:00:00
abstract::In the last decade, technological advances in the gaming industry have allowed the marketing of hardware for motion and balance control that is based on technological concepts similar to scientific and clinical equipment. Such hardware is attractive to researchers and clinicians for specific applications. However, som...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.07.011
更新日期:2016-09-06 00:00:00
abstract::During range of motion (max-ROM) tests performed on an isokinetic dynamometer, the mechanical delay between the button press (by the participant to signal their max-ROM) and the stopping of joint rotation resulting from system inertia induces errors in both max-ROM and maximum passive joint moment. The present study a...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.05.036
更新日期:2019-07-19 00:00:00
abstract::The nanomechanical properties of individual cartilage cells (chondrocytes) and their aggrecan and collagen-rich pericellular matrix (PCM) were measured via atomic force microscope nanoindentation using probe tips of two length scales (nanosized and micron-sized). The properties of cells freshly isolated from cartilage...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2006.04.004
更新日期:2007-01-01 00:00:00
abstract::Tendon elasticity is important for economical locomotion; however it is unknown whether tendon stiffness is appropriate to achieve an optimal efficiency in various muscles. Here we test the hypothesis that the Achilles tendon is of an appropriate stiffness to maximise medial gastrocnemius muscle efficiency during loco...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2006.07.025
更新日期:2007-01-01 00:00:00
abstract::In order to perform effective static stretching of the hip adductor muscles, it is necessary to clarify the position where the muscles are most stretched. However, the effective flexion angle in stretching for each adductor muscle remains unclear. The goal of this study was to investigate the effect of hip flexion ang...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109649
更新日期:2020-03-05 00:00:00
abstract::The main goal of this study was to evaluate the dynamics of sarcomeres during isometric activation of skeletal muscle myofibrils. Rabbit psoas myofibrils (n=14) were attached between a pair of cantilevers for force measurements at one side and a rigid glass needle at the other side, and their images were used for meas...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.08.011
更新日期:2009-12-11 00:00:00
abstract::Mechanical properties of abdominal and thoracic arteries of 2mm in diameter were determined from adults Wistar rats. A tensile testing instrument was used to obtain stress/strain curves with arteries immersed in physiological buffer at 37 degrees C. A displacement was applied on all arteries with various frequencies (...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.04.017
更新日期:2008-07-19 00:00:00
abstract::The considerable blood mixing in the bidirectional Glenn (BDG) physiology further limits the capacity of the single working ventricle to pump enough oxygenated blood to the circulatory system. This condition is exacerbated under severe conditions such as physical activity or high altitude. In this study, the effect of...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.03.021
更新日期:2014-06-03 00:00:00
abstract::Morphometrical and postural features of the cervical spine are supposed to significantly influence its biomechanical behaviour. However, the effects of these geometrical parameters are quite difficult to evaluate. An original numerical method is proposed in order to automatically generate parametric and subject-specif...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.04.007
更新日期:2009-07-22 00:00:00
abstract::This study reports for the first time an estimation of the internal net joint forces and torques on adults' lower limbs and pelvis when walking in shallow water, taking into account the drag forces generated by the movement of their bodies in the water and the equivalent data when they walk on land. A force plate and ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.01.017
更新日期:2011-04-07 00:00:00
abstract::Interstitial fluid flow has been shown to affect the organization and behavior of cells in 3D environments in vivo and in vitro, yet the forces driving such responses are not clear. Due to the complex architecture of the extracellular matrix (ECM) and the difficulty of measuring fluid flow near cells embedded in it, t...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2006.06.023
更新日期:2007-01-01 00:00:00
abstract::Gravity is a contributing force that is believed to influence strongly the control of limb movements since it affects sensory input and also contributes to task mechanics. By altering the relative contribution of gravitational force to the overall forces used to control pedaling at different body orientations, we test...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(96)00038-3
更新日期:1996-10-01 00:00:00
abstract::Twelve seated male subjects were exposed to 15 vibration conditions to investigate the nature and mechanisms of the non-linearity in biomechanical response. Subjects were exposed to three groups of stimuli: Group A comprised three repeats of random vertical vibration at 0.5, 1.0 and 1.5 ms(-2) r.m.s. with subjects sit...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.09.024
更新日期:2006-01-01 00:00:00
abstract::Many research groups have studied fall impact mechanics to understand how fall severity can be reduced to prevent hip fractures. Yet, direct impact force measurements with force plates are restricted to a very limited repertoire of experimental falls. The purpose of this study was to develop a generic model for estima...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.01.033
更新日期:2017-03-21 00:00:00
abstract:OBJECTIVE:To test if the caudal acetabulum of the cat is unloaded at mid-stance as has been asserted. MATERIALS AND METHODS:A kinematic study of five healthy cats was performed to ascertain the mid-stance angle of the hip joint, and the orientation of the pelvis and femur. Femora and pelves from 10 feline cadavers wer...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.04.035
更新日期:2005-03-01 00:00:00
abstract::Patello-femoral disorders are often caused by changes of patello-femoral and/or tibio-femoral kinematics. However, until now there has been no quantitative in vivo technique, that is able to obtain 3D kinematics and contact areas of all knee compartments simultaneously on a non-invasive basis. The aim of this study wa...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2003.09.034
更新日期:2004-06-01 00:00:00
abstract::Implant fixation implies a strong and durable mechanical bond between the prosthetic component and host skeleton. Assuming the short-term impediments to implant fixation are successfully addressed and that longer-term issues such as late infection and mechanical failure of the components are avoided, the biological re...
journal_title:Journal of biomechanics
pub_type: 杂志文章,评审
doi:10.1016/j.jbiomech.2014.12.021
更新日期:2015-03-18 00:00:00
abstract::The purpose of this project was to study a noninvasive method of evaluating limbs at risk of compartment syndrome. Untreated limb compartment syndrome may lead to irreversible dysfunction, chronic pain and contracture. An improved means of obtaining quantitative hardness measurements is reported. The handheld noninvas...
journal_title:Journal of biomechanics
pub_type: 临床试验,杂志文章
doi:10.1016/j.jbiomech.2004.07.030
更新日期:2005-08-01 00:00:00
abstract::Computational models have the potential to provide precise estimates of stresses and strains associated with sites of coronary plaque rupture. However, lack of adequate mathematical description of diseased human vessel wall mechanical properties is hindering computational accuracy. The goal of this study is to charact...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.11.019
更新日期:2012-03-15 00:00:00
abstract::We evaluated whether the use of cartilage thickness measurement would improve the ability of the arthroscopic indentation technique to estimate the intrinsic stiffness of articular cartilage. First, cartilage thickness and ultrasound reflection from the surface of bovine humeral head were registered in situ using a hi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(00)00189-5
更新日期:2001-02-01 00:00:00
abstract::A model is developed in which osteoblasts can sense the strains applied to a small region of bone through electrical coupling between adjacent cells. The stress-generated potentials within bone are assumed to occur through streaming potentials, and the coupled network of osteocytes is assumed to act in a manner simila...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(93)90048-j
更新日期:1993-02-01 00:00:00
abstract::To improve the treatments for low back pain, new designs of total disk replacement have been proposed. The question is how well these designs can act as a functional replacement of the intervertebral disk. Four finite element models were made, for four different design concepts, to determine how well they can mimic th...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.09.017
更新日期:2012-01-03 00:00:00
abstract::A general theory is described for deriving the mechanical effect of muscles with large attachment sites. In a cadaver experiment the complete attachment sites and bundle distribution of 16 muscles of the shoulder mechanism were recorded. These data were used to calculate the mechanical effect, i.e. the resulting force...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(91)90007-a
更新日期:1991-01-01 00:00:00
abstract::Continuous dynamic multi-segmental studies of lumbar motion have added depth to our understanding of the biomechanics of back pain, but few have attempted to continuously measure the proportions of motion accepted by individual levels. This study attempted to compare the motion contributions of adjacent lumbar levels ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109603
更新日期:2020-03-26 00:00:00
abstract::We compare the predictions of the differential equation form of a class of bone-density stress adaptation models with their associated discrete-time computational algorithms. Although our considerations apply to the class of adaptation models based on bulk or apparent bone-density remodeling, we focus attention on a p...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(05)80007-7
更新日期:1993-09-01 00:00:00
abstract::Current motion capture techniques all have shortcomings when applied to the 3D quantitative evaluation of thumb base motion. Dynamic CT might overcome these shortcomings but, so far, robustness of this technique in more than one specimen has not yet been demonstrated. The aim of the current study is to further evaluat...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.05.008
更新日期:2016-06-14 00:00:00
abstract::The swimming process by which mammal spermatozoa progress towards an egg within the reproductive organs is important in achieving successful internal fertilization. The viscosity of oviductal mucus is more than two orders of magnitude greater than that of water, and oviductal mucus also has non-Newtonian properties. I...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.08.005
更新日期:2015-09-18 00:00:00