Estimation of gait kinematics and kinetics from inertial sensor data using optimal control of musculoskeletal models.

Abstract:

:Inertial sensing enables field studies of human movement and ambulant assessment of patients. However, the challenge is to obtain a comprehensive analysis from low-quality data and sparse measurements. In this paper, we present a method to estimate gait kinematics and kinetics directly from raw inertial sensor data performing a single dynamic optimization. We formulated an optimal control problem to track accelerometer and gyroscope data with a planar musculoskeletal model. In addition, we minimized muscular effort to ensure a unique solution and to prevent the model from tracking noisy measurements too closely. For evaluation, we recorded data of ten subjects walking and running at six different speeds using seven inertial measurement units (IMUs). Results were compared to a conventional analysis using optical motion capture and a force plate. High correlations were achieved for gait kinematics (ρ⩾0.93) and kinetics (ρ⩾0.90). In contrast to existing IMU processing methods, a dynamically consistent simulation was obtained and we were able to estimate running kinetics. Besides kinematics and kinetics, further metrics such as muscle activations and metabolic cost can be directly obtained from simulated model movements. In summary, the method is insensitive to sensor noise and drift and provides a detailed analysis solely based on inertial sensor data.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Dorschky E,Nitschke M,Seifer AK,van den Bogert AJ,Eskofier BM

doi

10.1016/j.jbiomech.2019.07.022

subject

Has Abstract

pub_date

2019-10-11 00:00:00

pages

109278

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(19)30484-1

journal_volume

95

pub_type

杂志文章
  • Improving the clinical efficiency of T2(*) mapping of ligament integrity.

    abstract::Current MR methods use T2(*) relaxation time as a surrogate measure of ligament strength. Currently, a multi-echo voxel-wise least squares fit is the gold standard to create T2(*) maps; however, the post-processing is time-intensive and serves as a stopgap for clinical use. The study objective was to determine if an a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.03.037

    authors: Biercevicz AM,Walsh EG,Murray MM,Akelman MR,Fleming BC

    更新日期:2014-07-18 00:00:00

  • The role of muscles in joint degeneration and osteoarthritis.

    abstract::The purpose of this work was to establish a controlled and reversible muscle weakness model for studying the effects of weakness on joint degeneration leading to osteoarthritis (OA). The knee extensor muscles of rabbits were injected with single or repeat doses of Botulinum type-A toxin (BTX-A) to partially inhibit ac...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.03.001

    authors: Herzog W,Longino D

    更新日期:2007-01-01 00:00:00

  • Dynamic stability of individuals with transtibial amputation walking in destabilizing environments.

    abstract::Lower limb amputation substantially disrupts motor and proprioceptive function. People with lower limb amputation experience considerable impairments in walking ability, including increased fall risk. Understanding the biomechanical aspects of the gait of these patients is crucial in improving their gait function and ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.02.033

    authors: Beurskens R,Wilken JM,Dingwell JB

    更新日期:2014-05-07 00:00:00

  • Modelling the mechanical effect of muscles with large attachment sites: application to the shoulder mechanism.

    abstract::A general theory is described for deriving the mechanical effect of muscles with large attachment sites. In a cadaver experiment the complete attachment sites and bundle distribution of 16 muscles of the shoulder mechanism were recorded. These data were used to calculate the mechanical effect, i.e. the resulting force...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90007-a

    authors: Van der Helm FC,Veenbaas R

    更新日期:1991-01-01 00:00:00

  • Kinetic analysis of the center of gravity of the human body in normal and pathological gaits.

    abstract::The kinetics of the body's center of gravity during level walking were analyzed in 50 normal subjects and 47 patients. The three-dimensional displacements of the center of gravity were computed by the integration of force plate data. The energy levels and the power requirements of the center of gravity were also calcu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90328-9

    authors: Iida H,Yamamuro T

    更新日期:1987-01-01 00:00:00

  • Surface roughness parameters as predictors of anchorage strength in bone: a critical analysis.

    abstract::The surface roughness of a bone implant was defined parametrically. The values of the parameters defining the surface were varied. Some traditionally used surface roughness parameters were calculated. By means of a theoretical model the bone-implant interfacial shear strength was estimated. No simple correlation betwe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00045-2

    authors: Hansson S

    更新日期:2000-10-01 00:00:00

  • Growth and surface folding of esophageal mucosa: a biomechanical model.

    abstract::Mucosal folding in such biological vessels as esophagus and airway is essential to their physiological functions and can be affected by some diseases, e.g., inflammation, edema, lymphoma, and asthma. A biomechanical model within the framework of finite deformation theory is proposed to address the mucosal folding indu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.09.007

    authors: Li B,Cao YP,Feng XQ

    更新日期:2011-01-04 00:00:00

  • A computational fluid-structure interaction analysis of a fiber-reinforced stentless aortic valve.

    abstract::The importance of the aortic root compliance in the aortic valve performance has most frequently been ignored in computational valve modeling, although it has a significant contribution to the functionality of the valve. Aortic root aneurysm or (calcific) stiffening severely affects the aortic valve behavior and, cons...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00448-7

    authors: De Hart J,Baaijens FP,Peters GW,Schreurs PJ

    更新日期:2003-05-01 00:00:00

  • Effects of damage in the articular surface on the cartilage response to injurious compression in vitro.

    abstract::Macroscopic structural damage to the cartilage articular surface can occur due to slicing in surgery, cracking in mechanical trauma, or fibrillation in early stage osteoarthrosis. These alterations may render cartilage matrix and chondrocytes susceptible to subsequent mechanical injury and contribute to progression of...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.01.026

    authors: Morel V,Berutto C,Quinn TM

    更新日期:2006-01-01 00:00:00

  • The ground reaction force thresholds for detecting postural stability in participants with and without flat foot.

    abstract::Foot mobility commonly contributes to injury via altered motion of the lower extremities. However, there is a lack of understanding of sensitive kinetic changes with flat foot. The purpose of this study was to investigate the threshold that best distinguishes between participants with and without flat foot. The kineti...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.11.004

    authors: Sung PS

    更新日期:2016-01-04 00:00:00

  • Internal strain gradients quantified in bone under load using high-energy X-ray scattering.

    abstract::High-energy synchrotron X-ray scattering (>60 keV) allows noninvasive quantification of internal strains within bone. In this proof-of-principle study, wide angle X-ray scattering maps internal strain vs position in cortical bone (murine tibia, bovine femur) under compression, specifically using the response of the mi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.10.015

    authors: Stock SR,Yuan F,Brinson LC,Almer JD

    更新日期:2011-01-11 00:00:00

  • Strain shielding in distal femur after patellofemoral arthroplasty under different activity conditions.

    abstract::Strain shielding, a mechanical effect occurring in structures combining stiff with more flexible materials, is considered to lead to a reduction of density in bone surrounding the implant. This effect can be related to the weakness of the implant fixation, which can promote implant loosening. Several studies describe ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.09.048

    authors: Meireles S,Completo A,António Simões J,Flores P

    更新日期:2010-02-10 00:00:00

  • Direct calculation of the surface-to-volume ratio for human cancellous bone.

    abstract::There are many diseases which cause detrimental changes in the trabecular structure of cancellous bone, leading to mechanical failure of the tissue. One approach to understanding the mechanisms of these diseases is to create idealized models that recreate the morphology of the tissue. This paper presents a partial dev...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90057-l

    authors: Fyhrie DP,Fazzalari NL,Goulet R,Goldstein SA

    更新日期:1993-08-01 00:00:00

  • Improved walking function in laboratory does not guarantee increased community walking in stroke survivors: Potential role of gait biomechanics.

    abstract::Reduced daily stepping in stroke survivors may contribute to decreased functional capacity and increased mortality. We investigated the relationships between clinical and biomechanical walking measures that may contribute to changes in daily stepping activity following physical interventions provided to participants w...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.05.011

    authors: Ardestani MM,Henderson CE,Hornby TG

    更新日期:2019-06-25 00:00:00

  • Validation of optimization models that estimate the forces exerted by synergistic muscles.

    abstract::The purpose of this study was to validate the mathematical predictions of individual muscle forces obtained using optimization models. Mathematical muscle force predictions were made using linear and nonlinear optimization models proposed in the literature. Actual muscle forces were measured experimentally from soleus...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90375-w

    authors: Herzog W,Leonard TR

    更新日期:1991-01-01 00:00:00

  • Computational fluid dynamics for the assessment of upper airway response to oral appliance treatment in obstructive sleep apnea.

    abstract::Mandibular advancement splints (MAS), which protrude the lower jaw during sleep, are recognized as an effective treatment for obstructive sleep apnea (OSA) through their action of enlarging the airway space and preventing upper airway collapse. However a clinical challenge remains in preselecting patients who will res...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.10.033

    authors: Zhao M,Barber T,Cistulli P,Sutherland K,Rosengarten G

    更新日期:2013-01-04 00:00:00

  • Evaluation of the superficial characteristics of articular cartilage using evanescent waves in the friction tests with intermittent sliding and loading.

    abstract::Articular cartilage plays an important role in the lubrication of synovial joints because of its peculiar characteristics. In this work, the frictional and superficial characteristics of articular cartilage were evaluated simultaneously during intermittent sliding and loading. The apparatus used for the analysis of th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.06.015

    authors: Naka MH,Hattori K,Ikeuchi K

    更新日期:2006-01-01 00:00:00

  • Compressive properties of cd-HA-gelatin modified intrasynovial tendon allograft in canine model in vivo.

    abstract::Although we sometimes use the intrasynovial tendon allograft as a donor, the gliding ability of allograft prepared by lyophilization is significantly decreased. The gliding ability of the grafted tendon after tendon reconstruction is very important because the high gliding resistance causes more adhesion and leads to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.12.030

    authors: Ikeda J,Zhao C,Chen Q,Thoreson AR,An KN,Amadio PC

    更新日期:2011-06-03 00:00:00

  • Estimation of stride length in level walking using an inertial measurement unit attached to the foot: a validation of the zero velocity assumption during stance.

    abstract::In a variety of applications, inertial sensors are used to estimate spatial parameters by double integrating over time their coordinate acceleration components. In human movement applications, the drift inherent to the accelerometer signals is often reduced by exploiting the cyclical nature of gait and under the hypot...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.04.035

    authors: Peruzzi A,Della Croce U,Cereatti A

    更新日期:2011-07-07 00:00:00

  • Combining muscle synergies and biomechanical analysis to assess gait in stroke patients.

    abstract::The understanding of biomechanical deficits and impaired neural control of gait after stroke is crucial to prescribe effective customized treatments aimed at improving walking function. Instrumented gait analysis has been increasingly integrated into the clinical practice to enhance precision and inter-rater reliabili...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.08.006

    authors: Barroso FO,Torricelli D,Molina-Rueda F,Alguacil-Diego IM,Cano-de-la-Cuerda R,Santos C,Moreno JC,Miangolarra-Page JC,Pons JL

    更新日期:2017-10-03 00:00:00

  • Multiple-step model-experiment matching allows precise definition of dynamical leg parameters in human running.

    abstract::The spring-loaded inverted pendulum (SLIP) model is a well established model for describing bouncy gaits like human running. The notion of spring-like leg behavior has led many researchers to compute the corresponding parameters, predominantly stiffness, in various experimental setups and in various ways. However, dif...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.06.030

    authors: Ludwig C,Grimmer S,Seyfarth A,Maus HM

    更新日期:2012-09-21 00:00:00

  • 3D printed clamps improve spine specimen fixation in biomechanical testing.

    abstract::This study presents an anatomically customizable fixation technique for biomechanical spine experiments using a 3D printed clamping system. The aim of this study is to evaluate the feasibility and compare the fixation rigidity of the novel technique to PMMA potting with and without screw augmentation. For this purpose...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109467

    authors: Cornaz F,Fasser MR,Spirig JM,Snedeker JG,Farshad M,Widmer J

    更新日期:2020-01-02 00:00:00

  • Impact responses of the cervical spine: A computational study of the effects of muscle activity, torso constraint, and pre-flexion.

    abstract::Cervical spine injuries continue to be a costly societal problem. Future advancements in injury prevention depend on improved physical and computational models, which are predicated on a better understanding of the neck response during dynamic loading. Previous studies have shown that the tolerance of the neck is depe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.01.006

    authors: Nightingale RW,Sganga J,Cutcliffe H,Bass CR

    更新日期:2016-02-29 00:00:00

  • Pulsatile flow of non-Newtonian fluids through arterial stenoses.

    abstract::The problem of blood flow through stenoses is solved using the incompressible generalized Newtonian model. The Herschel-Bulkley, Bingham and power-law fluids are incorporated. The geometry corresponds to a rigid circular tube with a partial occlusion. Calculations are performed by a Galerkin finite-element method. For...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00151-4

    authors: Tu C,Deville M

    更新日期:1996-07-01 00:00:00

  • Fracture toughness and work of fracture of hydrated, dehydrated, and ashed bovine bone.

    abstract::Bone, a tri-phase composite, consists of nano-sized apatite minerals, an organic component, and water. Heat-treated bovine cortical bone has been proposed as a candidate for void-filling bone substitute. However, the toughness of heat-treated bone is not yet fully studied. Fracture toughness (K(c)) and work of fractur...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.03.037

    authors: Yan J,Daga A,Kumar R,Mecholsky JJ

    更新日期:2008-01-01 00:00:00

  • Reproducibility analysis of upper limbs reachable workspace, and effects of acquisition protocol, sex and hand dominancy.

    abstract::None of the physical testing, nor the goniometers currently used to assess upper limb function have a high validity, sensitivity or reliability. The reachable workspace, i.e. the area covered by the farthest points a subject can reach by hand without moving his/her body, shows promise but has yet to be validated, part...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.12.010

    authors: Clément J,Raison M,Rouleau DM

    更新日期:2018-02-08 00:00:00

  • An anatomy-based coordinate system for the description of the kinematic displacements in the human knee.

    abstract::The effects and interaction of the anatomical displacements in the human knee are a prerequisite to an accurate assessment and communication of the kinematic data. For the kinematic information to be used to improve diagnosis and treatment, and for better prosthetic design and installation, there must be clear, concis...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90378-g

    authors: Pennock GR,Clark KJ

    更新日期:1990-01-01 00:00:00

  • Numerical modelling of mass transport in an arterial wall with anisotropic transport properties.

    abstract::Coronary artery disease results in blockages or narrowing of the artery lumen. Drug eluting stents (DES) were developed to replace bare metal stents in an effort to combat re-blocking of the diseased artery following treatment. The numerical models developed within this study focus on representing the changing trends ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.09.017

    authors: Denny WJ,Walsh MT

    更新日期:2014-01-03 00:00:00

  • Comparison of three methods to estimate the center of mass during balance assessment.

    abstract::Evaluation of postural control is generally based on the interpretation of the center of pressure (COP) and the center of mass (COM) time series. The purpose of this study is to compare three methods to estimate the COM which are based on different biomechanical considerations. These methods are: (1) the kinematic met...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/S0021-9290(03)00251-3

    authors: Lafond D,Duarte M,Prince F

    更新日期:2004-09-01 00:00:00

  • Principles of determination and verification of muscle forces in the human musculoskeletal system: Muscle forces to minimise bending stress.

    abstract::While there are a growing number of increasingly complex methodologies available to model geometry and material properties of bones, these models still cannot accurately describe physical behaviour of the skeletal system unless the boundary conditions, especially muscular loading, are correct. Available in vivo measur...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2009.09.049

    authors: Sverdlova NS,Witzel U

    更新日期:2010-02-10 00:00:00