Biomechanical comparison of the human cadaveric pelvis with a fourth generation composite model.

Abstract:

:The use of cadavers for orthopaedic biomechanics research is well established, but presents difficulties to researchers in terms of cost, biosafety, availability, and ease of use. High fidelity composite models of human bone have been developed for use in biomechanical studies. While several studies have utilized composite models of the human pelvis for testing orthopaedic reconstruction techniques, few biomechanical comparisons of the properties of cadaveric and composite pelves exist. The aim of this study was to compare the mechanical properties of cadaveric pelves to those of the 4th generation composite model. An Instron ElectroPuls E10000 mechanical testing machine was used to load specimens with orientation, boundary conditions and degrees of freedom that approximated those occurring during the single legged phase of walking, including hip abductor force. Each specimen was instrumented with strain gauge rosettes. Overall specimen stiffness and principal strains were calculated from the test data. Composite specimens showed significantly higher overall stiffness and slightly less overall variability between specimens (composite K=1448±54N/m, cadaver K=832±62N/m; p<0.0001). Strains measured at specific sites in the composite models and cadavers were similar (but did differ) only when the applied load was scaled to overall construct stiffness. This finding regarding strain distribution and the difference in overall stiffness must be accounted for when using these composite models for biomechanics research. Altering the cortical wall thickness or tuning the elastic moduli of the composite material may improve future generations of the composite model.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Girardi BL,Attia T,Backstein D,Safir O,Willett TL,Kuzyk PR

doi

10.1016/j.jbiomech.2015.12.050

subject

Has Abstract

pub_date

2016-02-29 00:00:00

pages

537-42

issue

4

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(16)00008-7

journal_volume

49

pub_type

杂志文章
  • Sensitivity analysis of muscle properties and impact parameters on head injury risk in American football.

    abstract::Head injuries frequently occur in American football and other contact sports. Uncertainty on the effects of cervical muscle properties on head injury risk may be due to the limitations of previous observational studies. This simulation study employs a musculoskeletal model of the head and neck to investigate the effec...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109411

    authors: Mortensen JD,Vasavada AN,Merryweather AS

    更新日期:2020-02-13 00:00:00

  • A computational study on the influence of catheter-delivered intravascular probes on blood flow in a coronary artery model.

    abstract::Catheter-delivered intravascular probes are widely used in clinical practice to measure coronary arterial velocity and pressure, but the artefactual effect of the probe on the variables being measured is not well characterised. A coronary artery was simulated with a 180 degrees curved tube 3mm in diameter and the effe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.11.004

    authors: Torii R,Wood NB,Hughes AD,Thom SA,Aguado-Sierra J,Davies JE,Francis DP,Parker KH,Xu XY

    更新日期:2007-01-01 00:00:00

  • Planar biaxial characterization of diseased human coronary and carotid arteries for computational modeling.

    abstract::Computational models have the potential to provide precise estimates of stresses and strains associated with sites of coronary plaque rupture. However, lack of adequate mathematical description of diseased human vessel wall mechanical properties is hindering computational accuracy. The goal of this study is to charact...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.11.019

    authors: Kural MH,Cai M,Tang D,Gwyther T,Zheng J,Billiar KL

    更新日期:2012-03-15 00:00:00

  • Multiple-step model-experiment matching allows precise definition of dynamical leg parameters in human running.

    abstract::The spring-loaded inverted pendulum (SLIP) model is a well established model for describing bouncy gaits like human running. The notion of spring-like leg behavior has led many researchers to compute the corresponding parameters, predominantly stiffness, in various experimental setups and in various ways. However, dif...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.06.030

    authors: Ludwig C,Grimmer S,Seyfarth A,Maus HM

    更新日期:2012-09-21 00:00:00

  • Flat medial-lateral conformity in total knee replacements does not minimize contact stresses.

    abstract::The potential for wear in UHMWPE components for total knee replacements can be reduced by decreasing the stresses and strains arising from tibial-femoral contact. The conformity of the articular surfaces has a large effect on the resultant stresses, and components that achieve flat medial-lateral contact have been ass...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00172-5

    authors: Rawlinson JJ,Bartel DL

    更新日期:2002-01-01 00:00:00

  • Musculo-articular modelling of the triceps brachii.

    abstract::With the aim of proposing modelling equations for the length, force and shortening velocity of the triceps brachii, an X-ray and biomechanical study was carried out on the elbow joint. Two series of three upper right limbs removed from cadavers were used. It allowed us to situate the articular rotational axis of the e...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00032-1

    authors: Gerbeaux M,Turpin E,Lensel-Corbeil G

    更新日期:1996-02-01 00:00:00

  • Gait dynamics on an inclined walkway.

    abstract:OBJECTIVE:This paper documents research that quantifies and describes the biomechanics of normal gait on inclined surfaces. DESIGN:Experimental, investigative. BACKGROUND:It is necessary to walk on inclined surfaces to negotiate the natural and built environments. Little research has been conducted on the biomechanic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.07.025

    authors: McIntosh AS,Beatty KT,Dwan LN,Vickers DR

    更新日期:2006-01-01 00:00:00

  • Biomedical microfluidic devices by using low-cost fabrication techniques: A review.

    abstract::One of the most popular methods to fabricate biomedical microfluidic devices is by using a soft-lithography technique. However, the fabrication of the moulds to produce microfluidic devices, such as SU-8 moulds, usually requires a cleanroom environment that can be quite costly. Therefore, many efforts have been made t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2015.11.031

    authors: Faustino V,Catarino SO,Lima R,Minas G

    更新日期:2016-07-26 00:00:00

  • Effects of different temperatures, velocities and loads on the gliding resistance of flexor digitorum profundus tendons in a human cadaver model.

    abstract::The purpose of this study was to investigate the effects of temperature, velocity and load on the gliding resistance (GR) of flexor digitorum profundus (FDP) tendons in a human cadaver model. A total of 40 FDP tendons from the index through small digits of ten human cadavers were tested to assess the effect of tempera...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.01.011

    authors: Moriya T,Chikenji T,Thoreson AR,Zhao C,An KN,Amadio PC

    更新日期:2011-04-29 00:00:00

  • Micro-CT and micro-FE analysis of pedicle screw fixation under different loading conditions.

    abstract::Anchorage of pedicle screw instrumentation in the elderly spine with poor bone quality remains challenging. In this study, micro finite element (µFE) models were used to assess the specific influence of screw design and the relative contribution of local bone density to fixation mechanics. These were created from micr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.12.023

    authors: Chevalier Y,Matsuura M,Krüger S,Fleege C,Rickert M,Rauschmann M,Schilling C

    更新日期:2018-03-21 00:00:00

  • Improving the clinical efficiency of T2(*) mapping of ligament integrity.

    abstract::Current MR methods use T2(*) relaxation time as a surrogate measure of ligament strength. Currently, a multi-echo voxel-wise least squares fit is the gold standard to create T2(*) maps; however, the post-processing is time-intensive and serves as a stopgap for clinical use. The study objective was to determine if an a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.03.037

    authors: Biercevicz AM,Walsh EG,Murray MM,Akelman MR,Fleming BC

    更新日期:2014-07-18 00:00:00

  • In vivo muscular force analysis during the isometric flexion on a monkey's elbow.

    abstract::An experimental method has been developed to analyse muscular forces and torques in vivo during isometric flexion of the elbow in small monkeys (Macaca fascicularis). A mini-transducer was built with a view to measure forces in situ, without cutting tendons. The positions of tendon insertions were measured on anatomic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90220-5

    authors: Landjerit B,Maton B,Peres G

    更新日期:1988-01-01 00:00:00

  • The consequences of dehydration-hydration on bone anisotropy and implications on the sublamellar organization of mineralized collagen fibrils.

    abstract::In this study, the effect of dehydration-hydration based sublamellar dimensional change on bone anisotropy was used as a tool to understand sublamellar organization of mineralized collagen fibrils. Bone consists of hydroxyapatite, Type I Collagen, mucopolysaccharides and bone fluid, which associates with bone constitu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109737

    authors: Utku FS

    更新日期:2020-05-07 00:00:00

  • Ex-vivo observation of calcification process in chick tibia slice: Augmented calcification along collagen fiber orientation in specimens subjected to static stretch.

    abstract::Bone formation through matrix synthesis and calcification in response to mechanical loading is an essential process of the maturation in immature animals, although how mechanical loading applied to the tissue increases the calcification and improves mechanical properties, and which directions the calcification progres...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.07.024

    authors: Maeda E,Ichikawa K,Murase K,Nagayama K,Matsumoto T

    更新日期:2018-09-10 00:00:00

  • Multichannel strain gauge telemetry for orthopaedic implants.

    abstract::In vivo measurements of the loads and deformations occurring in orthopaedic implants will allow future improvements to be made. This paper describes an extremely small telemetry for long term measurements with three strain gauges and methods for an absolutely safe implant design. Developed for measuring the load at hi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90009-7

    authors: Bergmann G,Graichen F,Siraky J,Jendrzynski H,Rohlmann A

    更新日期:1988-01-01 00:00:00

  • Comparison of different camera calibration approaches for underwater applications.

    abstract::The purpose of this study was to compare three camera calibration approaches applied to underwater applications: (1) static control points with nonlinear DLT; (2) moving wand with nonlinear camera model and bundle adjustment; (3) moving plate with nonlinear camera model. The DVideo kinematic analysis system was used f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.01.004

    authors: Silvatti AP,Dias FA,Cerveri P,Barros RM

    更新日期:2012-04-05 00:00:00

  • Changes in stationary upright standing and proprioceptive reflex control of foot muscles after fatiguing static foot inversion.

    abstract::We searched for the consequences of a maximal static foot inversion sustained until exhaustion on the post-exercise stationary upright standing and the proprioceptive control of the foot muscles. Twelve healthy subjects executed an unilateral maximal static foot inversion during which continuous power spectrum analyse...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.04.005

    authors: Vie B,Gomez N,Brerro-Saby C,Weber JP,Jammes Y

    更新日期:2013-06-21 00:00:00

  • A biomechanical analysis of venous tissue in its normal and post-phlebitic conditions.

    abstract::Although biomechanical studies of the normal rat vein wall have been reported (Weizsacker, 1988; Plante, 2002), there are no published studies that have investigated the mechanical effects of thrombus formation on murine venous tissue. In response to the lack of knowledge concerning the mechanical consequences of thro...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.07.012

    authors: McGilvray KC,Sarkar R,Nguyen K,Puttlitz CM

    更新日期:2010-11-16 00:00:00

  • Shear and pressure under the first ray in neuropathic diabetic patients: Implications for support of the longitudinal arch.

    abstract:OBJECTIVE:To assess dynamic arch support in diabetic patients at risk for Charcot neuroarthopathy whose arch index has not yet shown overt signs of foot collapse. METHODS:Two indirect measures of toe flexor activation (ratios: peak hallux pressure to peak metatarsal pressure - Ph/Pm; peak posterior hallux shear to pea...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.12.024

    authors: Davis B,Crow M,Berki V,Ciltea D

    更新日期:2017-02-08 00:00:00

  • Energy-conserving impact algorithm for the heel-strike phase of gait.

    abstract::Significant ground reaction forces exceeding body weight occur during the heel-strike phase of gait. The standard methods of analytical dynamics used to solve the impact problem do not accommodate well the heel-strike collision due to the persistent contact at the front foot and presence of contact at the back foot. T...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00006-3

    authors: Kaplan ML,Heegaard JH

    更新日期:2000-06-01 00:00:00

  • Hemodynamic effects of long-term morphological changes in the human carotid sinus.

    abstract::Previous investigations of morphology for human carotid artery bifurcation from infancy to young adulthood found substantial growth of the internal carotid artery with advancing age, and the development of the carotid sinus at the root of the internal carotid artery during teenage years. Although the reasons for the a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.009

    authors: Seong J,Jeong W,Smith N,Towner RA

    更新日期:2015-04-13 00:00:00

  • Combining muscle synergies and biomechanical analysis to assess gait in stroke patients.

    abstract::The understanding of biomechanical deficits and impaired neural control of gait after stroke is crucial to prescribe effective customized treatments aimed at improving walking function. Instrumented gait analysis has been increasingly integrated into the clinical practice to enhance precision and inter-rater reliabili...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.08.006

    authors: Barroso FO,Torricelli D,Molina-Rueda F,Alguacil-Diego IM,Cano-de-la-Cuerda R,Santos C,Moreno JC,Miangolarra-Page JC,Pons JL

    更新日期:2017-10-03 00:00:00

  • Loads on an internal spinal fixation device during sitting.

    abstract::Sitting is often assumed to involve high loads on the spine as well as on implants for stabilising the spine. Loads on internal spinal fixation devices were therefore measured in ten patients sitting on several types of seats, including a stool, a stool with a padded wedge, a chair, a physiotherapy ball, a knee-stool,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00073-2

    authors: Rohlmann A,Arntz U,Graichen F,Bergmann G

    更新日期:2001-08-01 00:00:00

  • A finite element musculoskeletal model of the shoulder mechanism.

    abstract::The finite element method described in this study provides an easy method to simulate the kinetics of multibody mechanisms. It is used in order to develop a musculoskeletal model of the shoulder mechanism. Each relevant morphological structure has been represented by an appropriate element. For the shoulder mechanism ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90065-5

    authors: van der Helm FC

    更新日期:1994-05-01 00:00:00

  • Effects of a sustained extension on arterial growth and remodeling: a theoretical study.

    abstract::Three recent studies reveal that the unloaded length of a carotid artery increases significantly and rapidly in response to sustained increases in axial extension. Moreover, such lengthening involves an "unprecedented" increase in the rate of turnover of cells and matrix. Although current data are not sufficient for d...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.06.017

    authors: Gleason RL,Humphrey JD

    更新日期:2005-06-01 00:00:00

  • Finite element models predict cancellous apparent modulus when tissue modulus is scaled from specimen CT-attenuation.

    abstract::High-resolution architecture-based finite element models are commonly used for characterizing the mechanical behavior of cancellous bone. The vast majority of studies use homogeneous material properties to model trabecular tissue. The objectives of this study were to demonstrate that inhomogeneous finite element model...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.10.002

    authors: Bourne BC,van der Meulen MC

    更新日期:2004-05-01 00:00:00

  • Vastus lateralis and vastus medialis produce distinct mediolateral forces on the patella but similar forces on the tibia in the rat.

    abstract::Improper activation of the quadriceps muscles vastus medialis (VM) and vastus lateralis (VL) has been implicated in the development of patellofemoral pain (PFP). This explanation of PFP assumes that VM and VL produce opposing mediolateral forces on the patella. Although studies have provided evidence for opposing acti...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.09.007

    authors: Sandercock TG,Wei Q,Dhaher YY,Pai DK,Tresch MC

    更新日期:2018-11-16 00:00:00

  • Cost-effective (gaming) motion and balance devices for functional assessment: Need or hype?

    abstract::In the last decade, technological advances in the gaming industry have allowed the marketing of hardware for motion and balance control that is based on technological concepts similar to scientific and clinical equipment. Such hardware is attractive to researchers and clinicians for specific applications. However, som...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.07.011

    authors: Bonnechère B,Jansen B,Van Sint Jan S

    更新日期:2016-09-06 00:00:00

  • Concurrent repeatability and reproducibility analyses of four marker placement protocols for the foot-ankle complex.

    abstract::Multi-segment models of the foot have been proposed in the past years to overcome limitations imposed by oversimplified traditional approaches used to describe foot kinematics, but they have been only partially validated and never compared. This paper presents a unique comparative assessment of the four most widely ad...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.07.041

    authors: Di Marco R,Rossi S,Racic V,Cappa P,Mazzà C

    更新日期:2016-10-03 00:00:00

  • A mechanical model for the human intervertebral disc.

    abstract::Stress relaxation experiments were performed on specimens from a human intervertebral disc. Specimens were made from the nucleus pulposus and from the external lamellae of the anulus fibrosus in two different orientations. Tests were run with varying moisture content so as to develop a relaxation master curve. A model...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90144-8

    authors: Panagiotacopulos ND,Pope MH,Krag MH,Bloch R

    更新日期:1987-01-01 00:00:00