Optimization of intravascular shear stress assessment in vivo.

Abstract:

:The advent of microelectromechanical systems (MEMS) sensors has enabled real-time wall shear stress (WSS) measurements with high spatial and temporal resolution in a 3-D bifurcation model. To optimize intravascular shear stress assessment, we evaluated the feasibility of catheter/coaxial wire-based MEMS sensors in the abdominal aorta of the New Zealand white (NZW) rabbits. Theoretical and computational fluid dynamics (CFD) analyses were performed. Fluoroscope and angiogram provided the geometry of aorta, and the Doppler ultrasound system provided the pulsatile flow velocity for the boundary conditions. The physical parameters governing the shear stress assessment in NZW rabbits included (1) the position and distance from which the MEMS sensors were mounted to the terminal end of coaxial wire or the entrance length, (L(e)), (2) diameter ratios of aorta to the coaxial wire (D(aorta) /D(coaxial wire)=1.5-9.5), and (3) the range of Reynolds numbers (116-1550). At an aortic diameter of 2.4mm and a maximum Reynolds number of 212 (a mean Reynolds number of 64.2), the time-averaged shear stress (tau(ave)) was computed to be 10.06 dyn cm(-2) with a systolic peak at 33.18 dyn cm(-2). In the presence of a coaxial wire (D(aorta)/D(coaxial wire)=6 and L(e)=1.18 cm), the tau(ave) value increased to 15.54 dyn cm(-2) with a systolic peak at 51.25 dyn cm(-2). Real-time intravascular shear stress assessment by the MEMS sensor revealed an tau(ave) value of 11.92 dyn cm(-2) with a systolic peak at 47.04 dyn cm(-2). The difference between CFD and experimental tau(ave) was 18.5%. These findings provided important insights into packaging the MEMS sensors to optimize in vivo shear stress assessment.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Ai L,Yu H,Takabe W,Paraboschi A,Yu F,Kim ES,Li R,Hsiai TK

doi

10.1016/j.jbiomech.2009.04.021

subject

Has Abstract

pub_date

2009-07-22 00:00:00

pages

1429-1437

issue

10

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(09)00193-6

journal_volume

42

pub_type

杂志文章
  • The effects of exterior boundary conditions on a internally heated tumor tissue with a thermoporoelastic model.

    abstract::Modeling flow field in tumor regions interstitial space is of primary importance, because of the importance of advection in macromolecule drug delivery. Its deformation has also to be taken into account because of the forces caused by the fluid; if the tumor region is not isothermal, this deformation can be also stron...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110122

    authors: Andreozzi A,Iasiello M,Netti PA

    更新日期:2020-12-02 00:00:00

  • Interlimb coordination in body-weight supported locomotion: A pilot study.

    abstract::Locomotion involves complex neural networks responsible for automatic and volitional actions. During locomotion, motor strategies can rapidly compensate for any obstruction or perturbation that could interfere with forward progression. In this pilot study, we examined the contribution of interlimb pathways for evoking...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.04.042

    authors: Seiterle S,Susko T,Artemiadis PK,Riener R,Igo Krebs H

    更新日期:2015-08-20 00:00:00

  • Computational and clinical investigation on the role of mechanical vibration on orthodontic tooth movement.

    abstract::The aim of this study is to investigate the biomechanics for orthodontic tooth movement (OTM) subjected to concurrent single-tooth vibration (50Hz) with conventional orthodontic force application, via a clinical study and computational simulation. Thirteen patients were recruited in the clinical study, which involved ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.jbiomech.2017.06.012

    authors: Liao Z,Elekdag-Turk S,Turk T,Grove J,Dalci O,Chen J,Zheng K,Ali Darendeliler M,Swain M,Li Q

    更新日期:2017-07-26 00:00:00

  • Moment-rotation behavior of intervertebral joints in flexion-extension, lateral bending, and axial rotation at all levels of the human spine: A structured review and meta-regression analysis.

    abstract::Spinal intervertebral joints are complex structures allowing motion in multiple directions, and many experimental studies have reported moment-rotation response. However, experimental methods, reporting of results, and levels of the spine tested vary widely, and a comprehensive assessment of moment-rotation response a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,meta分析,评审

    doi:10.1016/j.jbiomech.2019.109579

    authors: Zhang C,Mannen EM,Sis HL,Cadel ES,Wong BM,Wang W,Cheng B,Friis EA,Anderson DE

    更新日期:2020-02-13 00:00:00

  • A novel validation and calibration method for motion capture systems based on micro-triangulation.

    abstract::Motion capture systems are widely used to measure human kinematics. Nevertheless, users must consider system errors when evaluating their results. Most validation techniques for these systems are based on relative distance and displacement measurements. In contrast, our study aimed to analyse the absolute volume accur...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.04.009

    authors: Nagymáté G,Tuchband T,Kiss RM

    更新日期:2018-06-06 00:00:00

  • An ultrasound based non-invasive method for the measurement of intrinsic foot kinematics during gait.

    abstract::Soft tissue artefact (STA) and marker placement variability are sources of error when measuring the intrinsic kinematics of the foot. This study aims to demonstrate a non-invasive, combined ultrasound and motion capture (US/MC) technique to directly measure foot skeletal motion. The novel approach is compared to a sta...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.12.014

    authors: Telfer S,Woodburn J,Turner DE

    更新日期:2014-03-21 00:00:00

  • The use of a single inertial sensor to estimate 3-dimensional ground reaction force during accelerative running tasks.

    abstract::The purpose of this investigation was to determine the feasibility of using a single inertial measurement unit (IMU) placed on the sacrum to estimate 3-dimensional ground reaction force (F) during linear acceleration and change of direction tasks. Force plate measurements of F and estimates from the proposed IMU metho...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.07.035

    authors: Gurchiek RD,McGinnis RS,Needle AR,McBride JM,van Werkhoven H

    更新日期:2017-08-16 00:00:00

  • Index-matched measurements of the effect of cartilaginous rings on tracheobronchial flow.

    abstract::We present a comparison of the flow characteristics in an idealized smooth trachea model and a second model which has a roughness simulating cartilaginous rings. We use refractive index-matched particle image velocimetry (PIV) to measure the velocity field in a two-generation model of the trachea and main bronchi. The...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.043

    authors: Bocanegra Evans H,Castillo L

    更新日期:2016-06-14 00:00:00

  • Superficial aponeurosis of human gastrocnemius is elongated during contraction: implications for modeling muscle-tendon unit.

    abstract::Two questions were addressed in this study: (1) how much strain of the superficial aponeurosis of the human medial gastrocnemius muscle (MG) was obtained during voluntary isometric contractions in vivo, (2) whether there existed inhomogeneity of the strain along the superficial aponeurosis. Seven male subjects, whose ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00196-8

    authors: Muramatsu T,Muraoka T,Kawakami Y,Fukunaga T

    更新日期:2002-02-01 00:00:00

  • Biomechanical influences of pin placement and elbow angle on hinge alignment and joint distraction of bridged elbow-pin-fixator construct.

    abstract::Joint distraction and mobilization with a hinged external fixator preserves elbow stability and mobility. However, the alignment of both elbow and fixator hinges was the initial prerequisite of the arthrodiatasis technique. The main goal of this study was to numerically evaluate the kinematic influence of the device, ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.07.030

    authors: Shih KS,Lin SC,Chao CK,Lee WS,Lu TW,Hou SM

    更新日期:2010-03-03 00:00:00

  • A computational study of invariant I5 in a nearly incompressible transversely isotropic model for white matter.

    abstract::The aligned axonal fiber bundles in white matter make it suitable to be modeled as a transversely isotropic material. Recent experimental studies have shown that a minimal form, nearly incompressible transversely isotropic (MITI) material model, is capable of describing mechanical anisotropy of white matter. Here, we ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.03.025

    authors: Feng Y,Qiu S,Xia X,Ji S,Lee CH

    更新日期:2017-05-24 00:00:00

  • Compressive properties of cd-HA-gelatin modified intrasynovial tendon allograft in canine model in vivo.

    abstract::Although we sometimes use the intrasynovial tendon allograft as a donor, the gliding ability of allograft prepared by lyophilization is significantly decreased. The gliding ability of the grafted tendon after tendon reconstruction is very important because the high gliding resistance causes more adhesion and leads to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.12.030

    authors: Ikeda J,Zhao C,Chen Q,Thoreson AR,An KN,Amadio PC

    更新日期:2011-06-03 00:00:00

  • Numerical modelling of mass transport in an arterial wall with anisotropic transport properties.

    abstract::Coronary artery disease results in blockages or narrowing of the artery lumen. Drug eluting stents (DES) were developed to replace bare metal stents in an effort to combat re-blocking of the diseased artery following treatment. The numerical models developed within this study focus on representing the changing trends ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.09.017

    authors: Denny WJ,Walsh MT

    更新日期:2014-01-03 00:00:00

  • Force-sharing between cat soleus and gastrocnemius muscles during walking: explanations based on electrical activity, properties, and kinematics.

    abstract::Studying force sharing between synergistic muscles can be useful for understanding the functional significance of musculoskeletal redundancy and the mechanisms underlying the control of synergistic muscles. The purpose of this study was to quantify and explain force sharing between cat soleus (SO) and gastrocnemius (G...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90276-3

    authors: Prilutsky BI,Herzog W,Allinger TL

    更新日期:1994-10-01 00:00:00

  • The effect of tendon viscoelastic stiffness on the dynamic performance of isometric muscle.

    abstract::The effect of tendons viscoelastic stiffness on the dynamic response of the cat's tibialis anterior muscle under isometric conditions was determined. It was shown that the dynamic response model of the muscle derived under sinusoidal contraction-relaxation in the range of 20-80% of its maximal isometric tension was no...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90355-q

    authors: Baratta R,Solomonow M

    更新日期:1991-01-01 00:00:00

  • Sagittal plane rotation center of lower lumbar spine during a dynamic weight-lifting activity.

    abstract::This study investigated the center of rotation (COR) of the intervertebral segments of the lower lumbar spine (L4-L5 and L5-S1 segments) in sagittal plane during a weight-lifting (3.6 kg in each hand) extension activity performed with the pelvis constrained. Seven healthy subjects were studied using a dual fluoroscopi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.12.029

    authors: Liu Z,Tsai TY,Wang S,Wu M,Zhong W,Li JS,Cha T,Wood K,Li G

    更新日期:2016-02-08 00:00:00

  • Numerical analysis of pulsatile blood flow and vessel wall mechanics in different degrees of stenoses.

    abstract::Hemodynamics factors and biomechanical forces play key roles in atherogenesis, plaque development and final rupture. In this paper, we investigated the flow field and stress field for different degrees of stenoses under physiological conditions. Disease is modelled as axisymmetric cosine shape stenoses with varying di...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.06.023

    authors: Li MX,Beech-Brandt JJ,John LR,Hoskins PR,Easson WJ

    更新日期:2007-01-01 00:00:00

  • The region-dependent dynamic properties of porcine temporomandibular joint disc under unconfined compression.

    abstract::In this study, the dynamic compressive properties in five different regions of the porcine temporomandibular joint (TMJ) disc are investigated over a wide range of loading frequencies. The aim was, thus far, to evaluate the regional difference and the frequency-related effect of the applied load on these properties. E...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.11.035

    authors: Fernández P,Jesús Lamela M,Ramos A,Fernández-Canteli A,Tanaka E

    更新日期:2013-02-22 00:00:00

  • Loads on an internal spinal fixation device during sitting.

    abstract::Sitting is often assumed to involve high loads on the spine as well as on implants for stabilising the spine. Loads on internal spinal fixation devices were therefore measured in ten patients sitting on several types of seats, including a stool, a stool with a padded wedge, a chair, a physiotherapy ball, a knee-stool,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00073-2

    authors: Rohlmann A,Arntz U,Graichen F,Bergmann G

    更新日期:2001-08-01 00:00:00

  • Prediction of distal radius fracture in children, using a biomechanical impact model and case-control data on playground free falls.

    abstract:OBJECTIVES:To assess the ability of a biomechanical impact model to predict the likelihood of distal radius fracture in children using data gathered for a previous epidemiological case-control study of falls from playground equipment. METHODOLOGY:Factor of Risk (FR) values were generated for each of selected subjects ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.11.028

    authors: Davidson PL,Chalmers DJ,Stephenson SC

    更新日期:2006-01-01 00:00:00

  • The effect of shortening history on isometric and dynamic muscle function.

    abstract::Despite numerous reports on isometric force depression, few reports have quantified force depression during active muscle shortening (dynamic force depression). The purpose of this investigation was to determine the influence of shortening history on isometric force following active shortening, force during isokinetic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.041

    authors: McDaniel J,Elmer SJ,Martin JC

    更新日期:2010-03-03 00:00:00

  • Effects of damage in the articular surface on the cartilage response to injurious compression in vitro.

    abstract::Macroscopic structural damage to the cartilage articular surface can occur due to slicing in surgery, cracking in mechanical trauma, or fibrillation in early stage osteoarthrosis. These alterations may render cartilage matrix and chondrocytes susceptible to subsequent mechanical injury and contribute to progression of...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.01.026

    authors: Morel V,Berutto C,Quinn TM

    更新日期:2006-01-01 00:00:00

  • Effect of the "squat protective response" on impact velocity during backward falls.

    abstract::Risk for injury during a fall depends on the position and velocity of the body segments at the moment of impact. One technique for reducing impact velocity is to absorb energy in the lower extremity muscles during descent, as occurs during squatting or sitting. However, the protective value of this response may depend...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2003.12.015

    authors: Robinovitch SN,Brumer R,Maurer J

    更新日期:2004-09-01 00:00:00

  • Quantification of bladder wall biomechanics during urodynamics: A methodologic investigation using ultrasound.

    abstract::Overactive bladder is often characterized by biomechanical changes in the bladder wall, but there is no established method to measure these changes in vivo. The goal of this study was to develop a novel method to determine detrusor wall biomechanical parameters during urodynamics through the incorporation of transabdo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.07.028

    authors: Nagle AS,Klausner AP,Varghese J,Bernardo RJ,Colhoun AF,Barbee RW,Carucci LR,Speich JE

    更新日期:2017-08-16 00:00:00

  • Resonant frequencies of arms and legs identify different walking patterns.

    abstract::The present study is aimed at investigating changes in the coordination of arm and leg movements in young healthy subjects. It was hypothesized that with changes in walking velocity there is a change in frequency and phase coupling between the arms and the legs. In addition, it was hypothesized that the preferred freq...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00020-8

    authors: Wagenaar RC,van Emmerik RE

    更新日期:2000-07-01 00:00:00

  • Sensitivity of dynamic simulations of gait and dynamometer experiments to hill muscle model parameters of knee flexors and extensors.

    abstract::We assessed and compared sensitivities of dynamic simulations to musculotendon (MT) parameters for gait and dynamometer experiments. Our aim with this comparison was to investigate whether dynamometer experiments could provide information about MT-parameters that are important to reliably study MT-function during gait...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.03.022

    authors: De Groote F,Van Campen A,Jonkers I,De Schutter J

    更新日期:2010-07-20 00:00:00

  • A new method for the early diagnosis of brain edema/brain swelling. An experimental study in rabbits.

    abstract::The aim of the present work is to develop a non-destructive, non-invasive technique for the early diagnosis of an oncoming brain edema based on the variation of vibration characteristics of the head system (i.e. eigenfrequency spectrum and modal damping). Besides the theoretical model that supports the basic principle...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.11.001

    authors: Kostopoulos V,Douzinas EE,Kypriades EM,Pappas YZ

    更新日期:2006-01-01 00:00:00

  • Kinetic analysis of the center of gravity of the human body in normal and pathological gaits.

    abstract::The kinetics of the body's center of gravity during level walking were analyzed in 50 normal subjects and 47 patients. The three-dimensional displacements of the center of gravity were computed by the integration of force plate data. The energy levels and the power requirements of the center of gravity were also calcu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90328-9

    authors: Iida H,Yamamuro T

    更新日期:1987-01-01 00:00:00

  • Osteochondral graft fixation using a bioresorbable bone cement.

    abstract::Multiple osteochondral grafts can be used to resurface large joint defects in both humans and horses. In humans, immediate postoperative weight bearing can be prevented, however in the equine, it is unavoidable. Early weight bearing can create detrimental graft micromotion. The aim of this study was to investigate the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.10.007

    authors: Changoor A,Hurtig MB,John Runciman R

    更新日期:2006-01-01 00:00:00

  • Crushed bone grafts and a collagen membrane are not suitable for enhancing cartilage quality in the regeneration of osteochondral defects--an in vivo study in sheep.

    abstract::Hyaline joint cartilage has only a limited potential for self-repair. Some of the published techniques for osteochondral defect therapy try to improve that potential. In this study, it was hypothesised that one of those surgical techniques, the crushed transplanted bone graft together with a collagen membrane, acceler...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.02.021

    authors: Schell H,Lienau J,Kleemann RU,Schlichting K,Taylor WR,Weiler A,Duda GN

    更新日期:2007-01-01 00:00:00