Abstract:
:The aim of this study is to investigate the biomechanics for orthodontic tooth movement (OTM) subjected to concurrent single-tooth vibration (50Hz) with conventional orthodontic force application, via a clinical study and computational simulation. Thirteen patients were recruited in the clinical study, which involved distal retraction of maxillary canines with 1.5N (150g) force for 12weeks. In a split mouth study, vibration and non-vibration sides were randomly assigned to each subject. Vibration of 50Hz, of approximately 0.2N (20g) of magnitude, was applied on the buccal surface of maxillary canine for the vibration group. A mode-based steady-state dynamic finite element analysis (FEA) was conducted based on an anatomically detailed model, complying with the clinical protocol. Both the amounts of space closure and canine distalization of the vibration group were significantly higher than those of the control group, as measured intra-orally or on models (p<0.05). Therefore it is indicated that a 50Hz and 20g single-tooth vibration can accelerate maxillary canine retraction. The volume-average hydrostatic stress (VHS) in the periodontal ligament (PDL) was computationally calculated to be higher with vibration compared with the control group for maxillary teeth and for both linguo-buccal and mesial-distal directions. An increase in vibratory frequency further amplified the PDL response before reaching a local natural frequency. An amplification of PDL response was also shown to be induced by vibration based on computational simulation. The vibration-enhanced OTM can be described by mild, vigorous and diminishing zones among which the mild zone is considered to be clinically beneficial.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Liao Z,Elekdag-Turk S,Turk T,Grove J,Dalci O,Chen J,Zheng K,Ali Darendeliler M,Swain M,Li Qdoi
10.1016/j.jbiomech.2017.06.012subject
Has Abstractpub_date
2017-07-26 00:00:00pages
57-64eissn
0021-9290issn
1873-2380pii
S0021-9290(17)30309-3journal_volume
60pub_type
杂志文章,随机对照试验abstract::The slit arteriotomy for end-to-side arterial microanastomosis is a technique used to revascularize free flaps in reconstructive surgery. Does a slit open to a width sufficient for blood supply? How is the slit opening affected by factors, such as arterial wall thickness and material stiffness? To answer these questio...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.12.015
更新日期:2006-01-01 00:00:00
abstract::This paper deals with the impact force during foot-ground impact activities such as the running. A previously developed model is used for this study. The model is a lumped-parameter one consisting of four masses connected to each other via linear springs and viscous dampers. A shoe-specific nonlinear function is used ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2006.09.016
更新日期:2007-01-01 00:00:00
abstract::In this study we investigated the time course of length and velocity of muscle fascicles and tendinous tissues (TT) during isometric twitch contraction, and examined how their interaction relates to the time course of external torque and muscle fascicle force generation. From seven males, supra-maximal twitch contract...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.03.023
更新日期:2007-01-01 00:00:00
abstract::We recently demonstrated that a set of five functional muscle synergies were sufficient to characterize both hindlimb muscle activity and active forces during automatic postural responses in cats standing at multiple postural configurations. This characterization depended critically upon the assumption that the endpoi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.09.012
更新日期:2008-01-01 00:00:00
abstract::A non-invasive, in vivo method has been developed to predict the skin flap shrinkage (retraction) following a harvest. It involves the use of a novel custom-designed extensometer to measure the force-displacement behaviour of skin and subsequent data analysis to estimate the shrinkage. In validation experiments perfor...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.03.012
更新日期:2008-01-01 00:00:00
abstract::The effect of non-habitual physical activity on bone architecture in the rat humeral shaft was examined. Two groups of rats were trained to swim for 1 h a day, for 20 weeks, at two training levels. The control group consisted of sedentary rats. Parameters of cross-sectional bone morphology (cross-section areas, princi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(89)90068-7
更新日期:1989-01-01 00:00:00
abstract::Falls due to slipping are a serious concern, with slipping estimated to cause 40-50% of all fall-related injuries. Epidemiological data indicates that older and obese adults experience more falls than young, non-obese individuals. An increasingly heavier and older U.S. population and workforce may be exacerbating the ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.01.018
更新日期:2016-03-21 00:00:00
abstract::Human responses are critical to understanding injury biomechanics in blunt ballistic impacts, which are defined as 20-200 g projectiles impacting at 20-250 m/s. 13 human cadavers were exposed to three distinct ballistic impacts of the chest to determine force-time, deflection-time and force-deflection responses. Compa...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(03)00238-0
更新日期:2004-01-01 00:00:00
abstract::The neck can be moved in six degrees of freedom. Current 3D-optoelectronic motion-capture systems capable of measuring these movements are inappropriate for use in clinical practice because they are stationary, expensive and time-consuming. We therefore developed a less complex 3D-tracking technology based on Steam®VR...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.109340
更新日期:2019-11-11 00:00:00
abstract::In presence of aortic stenosis, a jet is produced downstream of the aortic valve annulus during systole. The vena contracta corresponds to the location where the cross-sectional area of the flow jet is minimal. The maximal transvalvular pressure gradient (TPG(max)) is the difference between the static pressure in the ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.10.013
更新日期:2006-01-01 00:00:00
abstract::A fast (0.1 mm steps within 2 ms), strong (40 N continuously) and accurate (resolution 0.002 N and 1.0 micron) muscle ergometer was developed to test dynamic and static properties of mammalian muscle. Both for twitches and for tetani isometric, isokinetic and isotonic contractions can be measured accurately. Force-vel...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(87)90312-5
更新日期:1987-01-01 00:00:00
abstract::Leakage of blood alongside the implant is a relatively frequent and life-limiting complication after transcatheter aortic valve implantation. The aim of this study is to develop and validate a workflow to simulate the implantation prior to the intervention. Based on the simulation outcome, the amount of leakage is est...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.06.024
更新日期:2016-09-06 00:00:00
abstract::Muscle fatigue and recovery are complex processes influencing muscle force generation capacity. While fatigue reduces this capacity, recovery acts to restore the unfatigued muscle state. Many factors can potentially affect muscle recovery, and among these may be a task dependency of recovery following an exercise. How...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.11.061
更新日期:2017-01-25 00:00:00
abstract::Fragility fractures are a result of alterations in bone quantity, tissue properties, applied loads, or a combination of these factors. The current study addresses the contribution of cortical bone tissue properties to skeletal fragility by characterizing the shear damage accumulation processes which occur during torsi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(98)00179-1
更新日期:1999-03-01 00:00:00
abstract::Osteoarthritis (OA) is typically diagnosed in humans in its final stage when joint movement becomes painful. Clinical information about the onset and the mechanisms triggering the degenerative responses are virtually non-existent. However, research on animal models of experimental OA shows that joint adaptations assoc...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(97)00119-x
更新日期:1998-03-01 00:00:00
abstract::Rabbits were immobilized for 3 weeks with the ankle in plantar flexion, midrange position or dorsal extension (n=15). The left leg was used as control. Sarcomere lengths were measured by laser diffraction in vivo in the tibialis anterior (TA) muscle. Legs immobilized in the midrange position showed coherent diffractio...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.03.006
更新日期:2008-01-01 00:00:00
abstract::Bilateral asymmetry in gallop stride limb contact patterns of four Quarter Horse fillies was documented by high-speed cinematography. Horses were filmed with rider by two cameras simultaneously while galloping along a straightaway. Even though signaled for each gallop lead an equivalent number of times, horses frequen...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(87)90285-5
更新日期:1987-01-01 00:00:00
abstract::The biomechanical environment of the optic nerve head (ONH), of interest in glaucoma, is strongly affected by the biomechanical properties of sclera. However, there is a paucity of information about the variation of scleral mechanical properties within eyes and between individuals. We thus used biaxial testing to meas...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.02.031
更新日期:2010-06-18 00:00:00
abstract::Implant fixation implies a strong and durable mechanical bond between the prosthetic component and host skeleton. Assuming the short-term impediments to implant fixation are successfully addressed and that longer-term issues such as late infection and mechanical failure of the components are avoided, the biological re...
journal_title:Journal of biomechanics
pub_type: 杂志文章,评审
doi:10.1016/j.jbiomech.2014.12.021
更新日期:2015-03-18 00:00:00
abstract::There are many diseases which cause detrimental changes in the trabecular structure of cancellous bone, leading to mechanical failure of the tissue. One approach to understanding the mechanisms of these diseases is to create idealized models that recreate the morphology of the tissue. This paper presents a partial dev...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(93)90057-l
更新日期:1993-08-01 00:00:00
abstract::The purpose of the current investigation was to use finite element analysis to quantify the complete strain field for the membranes of the Flexercell apparatus, a device extensively used to study the effects of mechanical loading on cultured cells. Four vacuum pressure simulations were run for the membrane for both th...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.02.022
更新日期:2004-12-01 00:00:00
abstract::Propulsive forces generated by swimmers hand/forearm, have been studied through experimental tests. However, there are serious doubts as to whether forces quantified in this way are accurate enough to be meaningful. In order to solve some experimental problems, some numerical techniques have been proposed using Comput...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.03.012
更新日期:2006-01-01 00:00:00
abstract::Quantification of baseball hitting mechanics under game conditions help players to become successful batters and prevent injuries. Inertial measurement units (IMUs) can measure motion without any spatial restriction and are thus becoming a popular tool to investigate sports biomechanics. Biomechanical analysis of hitt...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.02.001
更新日期:2019-04-18 00:00:00
abstract::Hamstring muscle strain injury is one of the most common injuries in sports involving sprinting and kicking. Studies examining hamstring kinematics and activations are rich for sprinting but lacking for kicking. The purpose of this study was to examine kinematics and activations of hamstring muscles in instep and cut-...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.109482
更新日期:2020-01-23 00:00:00
abstract::A squeeze-film lubrication model of the human ankle joint in standing that takes into account the fluid transport across the articular surface is presented. Articular cartilage is a biphasic mixture of the ideal interstitial fluid and an elastic permeable isotropic homogeneous intrinsically incompressible matrix. The ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(00)00109-3
更新日期:2000-11-01 00:00:00
abstract::Experimental evidence demonstrates that collagen cross-linking in bone tissue significantly influences its deformation and failure behavior yet difficulties exist in determining the independent biomechanical effects of collagen cross-linking using in vitro and in vivo experiments. The aim of this study is to use a nan...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.02.017
更新日期:2008-01-01 00:00:00
abstract::Active tension developed while cardiac muscle shortens has been studied extensively under afterloaded isotonic or isovelocity conditions. However, these are not true in vivo loading conditions. To obtain more physiological loading, we controlled sarcomere length to follow the time courses that we observed previously i...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(96)00122-4
更新日期:1997-02-01 00:00:00
abstract::The natural stress distribution in the femur is significantly altered after total hip arthroplasty (THA). When an implant is introduced, it will carry a portion of the load, causing a reduction of stress in some regions of the remaining bone. This phenomenon is commonly known as stress shielding. In response to the ch...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(00)00110-x
更新日期:2000-12-01 00:00:00
abstract::The tibia from six-week old chickens that develop idiopathic scoliosis were studied with stress relaxation experiments and torsional strength testing. Most parameters observed did not show any significant differences between tibias obtained from chickens with scoliosis and tibias from the control birds; however, the r...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(83)90046-5
更新日期:1983-01-01 00:00:00
abstract::The cerebral ischemia and reperfusion rat model was employed in this experiment to study the rheological properties (i.e. viscosity, hematocrit, red blood cell deformability and thixotropic properties) of whole blood. The results of this study show that a significant relation exists between the duration of cerebral is...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(00)00180-9
更新日期:2001-02-01 00:00:00